998 resultados para 650202 Coal


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The moisture content of the coarse coking coal product from the centrifuges of preparation plants was investigated to evaluate the contribution of three types of water: that held internally in pores, that in fillets at points of contacts between the particles, and the moisture covering the surface. A standardised laboratory centrifuge test was used to measure the total non-centrifugable moisture (NCM) content and also the quantity held in internal pores, called NCMi. The fillet moisture NCMf was estimated by means of a formulation which relies on experimentally measured holdup volumes, supplemented by a physical model. The surface moisture NCMs could then be derived by difference. The NCMf, which depends on the body force, the particle size and the surface tension and contact angle of the liquid, ranges from effectively zero for large particles to 10% for fines. The surface moisture NCMs is of the order of 0.5% for high rank coals and increases to 4.5% for lower rank coals. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Borecore samples from the Trap Gully pit at Callide have been assessed using the R-70 self-heating test. The highest R-70 self-heating rate value was 16.22 degrees C/h, which is consistent with the subbituminous rank of the coal. R-70 decreases significantly with increasing mineral matter content, as defined by the ash content of the coal. This effect is due to the mineral matter in the coal acting as a heat sink. A trendline equation has been fitted to the borecore data from the Trap Gully pit: R-70 = 0.0029 x ash(2) - 0.4889 x ash + 20.644, where all parameters are on a dry-basis. This relationship can be used to model the self-heating hazard of the pit, both vertically and laterally. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Strip samples from the Boundary Hill pit at Callide have been tested in an adiabatic oven to assess the effect of moisture on the R-70 self-heating rate of coal. The two strip samples tested had R-70 self-heating rate values of 10.23 and 8.61 degrees C/h. As the moisture content of the coal was progressively increased, from the dry state of the test, the R-70 value decreased dramatically. At approximately 40-50% of the moisture holding capacity of the coal, the self-heating rate becomes measurable. Above this critical level of moisture content, the heat produced by oxidation is dissipated by moisture evaporation and coal self-heating is significantly delayed. (c) 2005 Elsevier B.V All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Relevância:

70.00% 70.00%

Publicador:

Resumo:

There are many physical factors that can affect the self-heating rate of coal. The presence of seam gas has often been referred to as inhibiting coal self-heating due to the limited access of oxidation sites created by the presence of the gas adsorbed on the coal pores. Similarly, the presence of bed moisture in the coal also acts as an inhibitor of oxidation by blocking access of air into the pores. Gas drainage of a coal seam prior to mining removes both gas and moisture from the seam. Bulk coal self-heating tests in a two-metre column on both gassy, as-mined and gas-drained, dried high volatile bituminous coal show that removal of gas and moisture from the coal accelerates the rate of self-heating to thermal runaway from 8.5 days to 4.25 days, from a start temperature of 30°C, with an airflow of 0.25 L/min. The corresponding gas evolution pattern for each of these situations is different. Therefore, it is necessary to take this change in coal condition into consideration when developing a spontaneous combustion management plan.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The processes that take place during the development of a heating are difficult to visualise. Bulk coal self-heating tests at The University of Queensland (UQ) using a two-metre column are providing graphic evidence of the stages that occur during a heating. Data obtained from these tests, both temperature and corresponding off-gas evolution can be transformed into what is effectively a video-replay of the heating event. This is achieved by loading both sets of data into a newly developed animation package called Hotspot. The resulting animation is ideal for spontaneous combustion training purposes as the viewer can readily identify the different hot spot stages and corresponding off-gas signatures. Colour coding of the coal temperature, as the hot spot forms, highlights its location in the coal pile and shows its ability to migrate upwind. An added benefit of the package is that once a mine has been tested in the UQ two-metre column, there is a permanent record of that particular coals performance for mine personnel to view.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Numerical modelling has been used to examine the relationship between the results of two commonly used methods of assessing the propensity of coal to spontaneous combustion, the R70 and Relative Ignition Temperature tests, and the likely behaviour in situ. The criticality of various parameters has been examined and a method of utilising critical self-heating parameters has been developed. This study shows that on their own, the laboratory test results do not provide a reliable guide to in situ behaviour but can be used in combination to considerably increase the ability to predict spontaneous combustion behaviour.