904 resultados para 13627-022
Resumo:
This series of research vignettes is aimed at sharing current and interesting research findings from our team of international Entrepreneurship researchers. In this vignette, Dr. Mervyn Morris considers the impact on family business operations due to the sudden and unexpected death of a key family member.
Resumo:
1962-1972 / La Dirección -- La Teología al servicio de la Palabra de Dios / Carmelo Giaquinta -- El “Padre Nuestro” en el Evangelio según san Mateo / Luis H. Rivas -- La liberación. Aspectos bíblicos: evaluación crítica / José Mejía -- Matrimonio y sacerdocio: sacramento, fidelidad, castidad / Eduardo Briancesco -- Palabras y gestos en la Reconciliación sacramental / Luis Alessio -- El matrimonio en los Sínodos del Obispo Trejo / José M. Arancibia -- Propiedad de los medios de producción y pensamiento social de la Iglesia / Carmelo Giaquinta -- Reflexiones acerca de la pastoral popular desde el interior de un santuario / Guillermo Rodríguez Melgarejo -- Algunos principios para una teología de la pastoral popular / Ernesto Mai -- Nota bibliográficas -- Libros recibidos -- Crónica de la Facultad -- Índice del Tomo X
Resumo:
A Comissão de Sistematização da Assembleia Nacional Constituinte (ANC), responsável por redigir o texto da Carta Constitucional, realizou a Primeira Reunião Ordinária com o objetivo de definir o programa de trabalho. A Comissão tem como presidente o Senador Afonso Arinos (PFL-RJ), como relator o Deputado Bernardo Cabral (PMDB-AM) e outros 47 constituintes titulares. As oito comissões devem entregar, até o dia 15 de julho de 1988, o texto com a conclusão dos seus trabalhos à Comissão de Sistematização para que seja elaborado o texto definitivo. O Deputado Milton Reis (PMDB-MG) observa a importância do consenso, entre temas divergentes, no texto final da Constituição. Na Subcomissão de Tributos, Participação e Distribuição das Receitas, Geraldo Ataliba, professor de direito tributário da USP, explica a importância de uma revisão em todos os impostos e taxas. O Deputado Fernando Bezerra (PMDB-PE) defende a redistribuição do sistema tributário brasileiro. Na Subcomissão dos Direitos e Garantias Individuais, José Calixto Ramos, presidente da CTI, defende a autonomia sindical. A Subcomissão dos Direitos e Garantias Individuais, o professor Cândido Mendes pede aos constituintes a criação de mecanismos de autodefesa da sociedade: a ação popular e a defensoria pública.
Resumo:
El proyecto se inició en mayo de 1978 y se terminó en diciembre de 1981. Sus objetivos principales con establecer las bases científicas para la administración racional de las pesquerías peruanas de aguas continentales y para su óptima utilización.
Resumo:
Servicios registrales
Resumo:
La Cámara de Comercio de Bogotá inscribió el acta No. 005 de la asamblea general de la entidad sin ánimo de lucro FUNDACIÓN HORIZONTES DEL FUTURO en la cual se reemplazaban algunos miembros de la junta directiva. Dos (2) asociados y miembros de la junta directiva de la fundación, interpusieron recurso de reposición y solicitaron la nulidad del acto administrativo señalado.
Resumo:
The knowledge of the mechanical properties of nickel-titanium (NiTi) termoactives of the more accessible of the domestic market is still limited. Given this, the objective of this study was to evaluate and compare through deflection tests in brackets NiTi wires 03 term rectangular gauge 0.014 '' enabled x 0.025 '' and 0.016 '' x 0.022 '' of different brands (MORELLI (R), ORMCO (R) ORTHOSOURCE (R), ORTHOMETRIC (R), EURODONTO (R) and ADITEK (R)). All tests were carried out on universal testing machine EMIC DL 2000 under identical conditions and controlled at a temperature of 36 degrees C +/- 0.5 degrees C. Five measurements (N= 5) were performed for each thickness/wire tag that was deflected up to a limit of 4.0mm at a speed of 1.0mm/min. Each 0.2mm (round trip) of corresponding strength measured deflection for the construction of the graph of force x deflection at Tesc program version 3.04. Each graphic was evaluated according to the following variables: beginning of the Martensitic transformation (cN and mm), maximum strength (cN), the beginning and end of the plateau of deactivation (cN and mm) and length (mm) plateau. The average and standard deviation were calculated for all variables and statistical analysis was made by ANOVA tests 2 criteria and Turkey or Kruskal-Wallis and Dunn, a 5% level of significance. The results showed that the tests of 0.014 '' x0.025 '' ORTHOMETRIC (R) brands and ORMCO (R) showed the best results, as well as the wires of the MORELLI (R) and ORTHOSOURCE (R) to wires 0.016 '' x0.022 ''. In General, the gauge wires 0.014 '' x0.025 '' showed strength levels on the plateau of deactivation to 6 x smaller than 0.016 '' x0.022 '' caliber.
Resumo:
The aim of this study was to assess the effect of the moments generated with low- and high-torque brackets. Four different bracket prescription-slot combinations of the same bracket type (Mini Diamond® Twin) were evaluated: high-torque 0.018 and 0.022 inch and low-torque 0.018 and 0.022 inch. These brackets were bonded on identical maxillary acrylic resin models with levelled and aligned teeth and each model was mounted on the orthodontic measurement and simulation system (OMSS). Ten specimens of 0.017 × 0.025 inch and ten 0.019 × 0.025 inch stainless steel archwires (ORMCO) were evaluated in the low- and high-torque 0.018 inch and 0.022 inch brackets, respectively. The wires were ligated with elastomerics into the brackets and each measurement was repeated once after religation. Two-way analysis of variance and t-test were conducted to compare the generated moments between wires at low- and high-torque brackets separately. The maximum moment generated by the 0.017 × 0.025 inch stainless steel archwire in the 0.018 inch brackets at +15 degrees ranged from 14.33 and 12.95 Nmm for the high- and low-torque brackets, respectively. The measured torque in the 0.022 inch brackets with the 0.019 × 0.025 inch stainless steel archwire was 9.32 and 6.48 Nmm, respectively. The recorded differences of maximum moments between the high- and low-torque series were statistically significant. High-torque brackets produced higher moments compared with low-torque brackets. Additionally, in both high- and low-torque configurations, the thicker 0.019 × 0.025 inch steel archwire in the 0.022 inch slot system generated lower moments in comparison with the 0.017 × 0.025 inch steel archwire in the 0.018 inch slot system.
Resumo:
OBJECTIVE To compare the archwires inserted during the final stages of the orthodontic treatment with the generated moments at 0.018- and 0.022-inch brackets. MATERIALS AND METHODS The same bracket type, in terms of prescription, was evaluated in both slot dimensions. The brackets were bonded on two identical maxillary acrylic resin models, and each model was mounted on the orthodontic measurement and simulation system. Ten 0.017 × 0.025-inch TMA and ten 0.017 × 0.025-inch stainless steel archwires were evaluated in the 0.018-inch brackets. In the 0.022-inch brackets, ten 0.019 × 0.025-inch TMA and ten 0.019 × 0.025-inch stainless steel archwires were measured. A 15° buccal root torque (+15°) and then a 15° palatal root torque (-15°) were gradually applied to the right central incisor bracket, and the moments were recorded at these positions. A t-test was conducted to compare the generated moments between wires within the 0.018- and 0.022-inch bracket groups separately. RESULTS The 0.017 × 0.025-inch archwire in the 0.018-inch brackets generated mean moments of 9.25 Nmm and 14.2 Nmm for the TMA and stainless steel archwires, respectively. The measured moments in the 0.022-inch brackets with the 0.019 × 0.025-inch TMA and stainless steel archwires were 6.6 Nmm and 9.3 Nmm, respectively. CONCLUSION The 0.017 × 0.025-inch stainless steel and β-Ti archwires in the 0.018-inch slot generated higher moments than the 0.019 × 0.025-inch archwires because of lower torque play. This difference is exaggerated in steel archwires, in comparison with the β-Ti, because of differences in stiffness. The differences of maximum moments between the archwires of the same cross-section but different alloys were statistically significant at both slot dimensions.