965 resultados para simplified CDD
Resumo:
The World Health Organisation suggests that simplification of the medical abortion regime will contribute to an increased acceptability of medical abortion, among women as well as providers. It is expected that a home-based follow-up after a medical abortion will increase the willingness to opt for medical abortion as well as decrease the workload and service costs in the clinic. Trial design The study is a randomised, controlled, non-superiority trial . Methods Women screened to participate in the study are those with unwanted pregnancies and gestational ages equal to or less than nine weeks. Eligible women randomised to the home-based assessment group will use a low-sensitivity pregnancy test and a pictorial instruction sheet at home, while the women in the clinic follow-up group will return to the clinic for routine follow-up carried out by a doctor. The primary objective of the study is to evaluate the effectiveness of home-based assessment using a low-sensitivity pregnancy test and a pictorial instruction sheet 10-14 days after an early medical abortion. Providers or research assistants will not be blinded during outcome assessment. To ensure feasibility of the self-assessment intervention an adaption phase took place at the selected study sites before study initiation. This was to optimise and tailor-make the intervention and the study procedures and resulted in the development of the pictorial instruction sheet for how to use the low-sensitivity pregnancy test and the danger signs after a medical abortion. Discussion In this paper, we will describe the study protocol for a randomised control trial investigating the efficacy of simplified follow-up in terms of home-based assessment, 10-14 days after a medical abortion. Moreover, a description of the adaptation phase is included for a better understanding of the implementation of the intervention in a setting where literacy is low and the road-connections are poor. Trial registration: Clinicaltrials.gov NCT01827995. Registered 04 May 2013
Resumo:
Solar plus heat pump systems are often very complex in design, with sometimes special heat pump arrangements and control. Therefore detailed heat pump models can give very slow system simulations and still not so accurate results compared to real heat pump performance in a system. The idea here is to start from a standard measured performance map of test points for a heat pump according to EN 14825 and then determine characteristic parameters for a simplified correlation based model of the heat pump. By plotting heat pump test data in different ways including power input and output form and not only as COP, a simplified relation could be seen. By using the same methodology as in the EN 12975 QDT part in the collector test standard it could be shown that a very simple model could describe the heat pump test data very accurately, by identifying 4 parameters in the correlation equation found. © 2012 The Authors.
Resumo:
The clausal resolution method for propositional linear-time temporal logic is well known and provides the basis for a number of temporal provers. The method is based on an intuitive clausal form, called SNF, comprising three main clause types and a small number of resolution rules. In this paper, we show how the normal form can be radically simplified, and consequently, how a simplified clausal resolutioin method can be defined for this impoprtant variety of logics.
Resumo:
This study investigates the utilisation of a simplified model in the transient analysis of a thermal cooling process. In such process the external thermal resistance between the surface and the surroundings is high compared to the system internal thermal resistance, so that the first controls the heat transfer process. In this case the Biot number is lower than 0.1. Aluminium reels were utilised, which, with proper internal instrumentation, furnished experimental results for the thermal cooling process. Based on experimental data, a simplified model for the determination of the process film coefficient was used. Subsequently, experimental and theoretical results were compared. The change of the airflow direction was also investigated for the cooling process, aiming at process time optimisation. (C) 2001 Elsevier B.V. Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
This clinical report describes a method to reduce the number of clinical sessions for the rehabilitation of implant-supported fixed dentures through a simplified and versatile procedure indicated mainly for immediate loading. According to this method, the immediate implant-supported fixed dentures for edentulous patients can be safely fabricated within 2 days. In this technique, the teeth in the wax are prepared on a base of light-polymerized resin, and both wax teeth and metallic superstructure trials are accomplished at the same session.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this paper, we investigate potential symmetries of a simplified model for reacting mixtures. We find new similarity reductions and wider class of solutions through this approach. Further, we explore an invertible mapping which linearizes the reacting mixture model.
Resumo:
A simplified version of a time-dependent annular billiard is studied. The dynamics is described using nonlinear maps and we consider two different configurations for the billiard, namely (i) concentric and (ii) eccentric cases. For the concentric case and for a null angular momentum, we confirm that the results for the Fermi-Ulam model are recovered and the particle does not experience the phenomenon of Fermi acceleration. However, on the eccentric case the particle demonstrates unlimited energy gain and Fermi acceleration is therefore observed.
Resumo:
This work presents the design of a fuzzy controller with simplified architecture that use an artificial neural network working as the aggregation operator for several active fuzzy rules. The simplified architecture of the fuzzy controller is used to minimize the time processing used in the closed loop system operation, the basic procedures of fuzzification are simplified to maximum while all the inference procedures are computed in a private way. As consequence, this simplified architecture allows a fast and easy configuration of the simplified fuzzy controller. The structuring of the fuzzy rules that define the control actions is previously computed using an artificial neural network based on CMAC Cerebellar Model Articulation Controller. The operational limits are standardized and all the control actions are previously calculated and stored in memory. For applications, results and conclusions several configurations of this fuzzy controller are considered.
Resumo:
A simple and rapid method for the determination of 13 organophosphorus insecticides and their metabolites in olive oil by GC is described. The pesticide was extracted from oil with acetonitrile and no cleanup was needed. GC-nitrogen-phosphorus detection response factors of pesticides were affected by solvents and coextractive substances. Pesticides in hexane showed on average higher response factors. Standards were prepared in the residue-free oil extract solubilized in hexane to handle effects of matrix and solvent. The low amount of coextractive substances does not decrease the column efficiency, even after a few hundred analyses. Recovery at three fortification levels (ca. 0.1, 1.0 and 3.0 mg/kg) ranged from 74 to 118%, With coefficients of variation ranging from 1 to 16.
Resumo:
This work presents a simplified architecture of a neurofuzzy controller for general purpose applications that tries to minimize the processing used in the several stages of hazy modeling of systems. The basic procedures of fuzzification and defuzzification are simplified to the maximum while the inference procedures are computed in a private way. The simplified architecture allows a fast and easy configuration of the neurofuzzy controller and the structuring rules that define the control actions is automatic. Th controller's Limits and performance are standardized and the control actions are previously calculated. For application, the industrial systems of fluid flow control will be considered.
Resumo:
A simple and efficient method is described for the determination of fenpropathrin in oranges, pears, apples and strawberries. The procedure: is based on the extraction of each homogenized fruit sample with hexane:acetone (1:1, v/v) mixture, followed, by a cleanup technique on a column packed with florisil, using a hexane:ethyl ether (7:3, v/v) mixture, and gas chromatographic, analysis with electron capture detection (ECD). The fortification levels (0.5; 1.0; 2.0 mg kg(-1)) were selected according to the maximum residue limits (MRLs) established for fenpropathrin by Brazilian legislation. Mean recoveries from five replicates of fortified fruit samples ranged from 83 % to 98 %, with:coefficients of variation from 1.4 to 13.5 and detection limits varying from 0.1 to 0.2 mg kg(-1).