Time reduction in a forced-convection thermal process using simplified transient analysis


Autoria(s): Sobrinho, P. M.; Magalhaes, P.; Carvalho, J. A.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/08/2001

Resumo

This study investigates the utilisation of a simplified model in the transient analysis of a thermal cooling process. In such process the external thermal resistance between the surface and the surroundings is high compared to the system internal thermal resistance, so that the first controls the heat transfer process. In this case the Biot number is lower than 0.1. Aluminium reels were utilised, which, with proper internal instrumentation, furnished experimental results for the thermal cooling process. Based on experimental data, a simplified model for the determination of the process film coefficient was used. Subsequently, experimental and theoretical results were compared. The change of the airflow direction was also investigated for the cooling process, aiming at process time optimisation. (C) 2001 Elsevier B.V. Ltd.

Formato

867-876

Identificador

http://dx.doi.org/10.1016/S0735-1933(01)00290-1

International Communications In Heat and Mass Transfer. Oxford: Pergamon-Elsevier B.V., v. 28, n. 6, p. 867-876, 2001.

0735-1933

http://hdl.handle.net/11449/9027

10.1016/S0735-1933(01)00290-1

WOS:000170850100014

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

International Communications In Heat and Mass Transfer

Direitos

closedAccess

Tipo

info:eu-repo/semantics/article