953 resultados para operating room nurse


Relevância:

80.00% 80.00%

Publicador:

Resumo:

© 2014, Canadian Anesthesiologists' Society.Optimal perioperative fluid management is an important component of Enhanced Recovery After Surgery (ERAS) pathways. Fluid management within ERAS should be viewed as a continuum through the preoperative, intraoperative, and postoperative phases. Each phase is important for improving patient outcomes, and suboptimal care in one phase can undermine best practice within the rest of the ERAS pathway. The goal of preoperative fluid management is for the patient to arrive in the operating room in a hydrated and euvolemic state. To achieve this, prolonged fasting is not recommended, and routine mechanical bowel preparation should be avoided. Patients should be encouraged to ingest a clear carbohydrate drink two to three hours before surgery. The goals of intraoperative fluid management are to maintain central euvolemia and to avoid excess salt and water. To achieve this, patients undergoing surgery within an enhanced recovery protocol should have an individualized fluid management plan. As part of this plan, excess crystalloid should be avoided in all patients. For low-risk patients undergoing low-risk surgery, a “zero-balance” approach might be sufficient. In addition, for most patients undergoing major surgery, individualized goal-directed fluid therapy (GDFT) is recommended. Ultimately, however, the additional benefit of GDFT should be determined based on surgical and patient risk factors. Postoperatively, once fluid intake is established, intravenous fluid administration can be discontinued and restarted only if clinically indicated. In the absence of other concerns, detrimental postoperative fluid overload is not justified and “permissive oliguria” could be tolerated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Sjuksköterskor som arbetar på akutmottagningar utsätts regelbundet för stress. Det medför psykiska och fysiska besvär för sjuksköterskor och försämrad omvårdnad för patienten. Studien avser att utifrån vetenskaplig litteratur sammanställa de faktorer som leder till stress för sjuksköterskor som arbetar på akutmottagningar och hur vården påverkas av stressade sjuksköteskor. Syfte Syftet med litteraturstudien var att beskriva vilka faktorer på akutmottagningen som upplevdes bidra till stress för sjuksköterskor som arbetar på en akutmottagning och hur stressen påverkar sjuksköterskors möjligheter att erbjuda en god vård för patienter på akutmottagningen. Metod Studien har genomförts som en litteraturstudie. I studien användes 15 artiklar som bestod av både kvalitativ och kvantitativ ansats. Materialet hämtades i databaserna CINAHL och PubMed. Resultat Resultatet visar att det finns flera olika faktorer som bidrar till stress för sjuksköterskor på akutmottagningen. Stressande faktorer visade sig utifrån studierna i resultatet vara; hög arbetsbelastning och låg bemanning, avsaknad av tid för reflektion för sjuksköterskan, att vårda barn i stressade situationer, hot och våld på akutmottagningen, kommunikation samt smärta och lidande. Hur vården påverkas av sjuksköterskors stress på akutmottagningen var utifrån studierna att patientsäkerheten blev försämrad och att vårdrelationen påverkades. Slutsats Författarna drar slutsatsen att stress påverkar sjuksköteskors arbetsuppgifter på akutmottagningen. Patienters möjlighet till patientsäker och god vård på akutmottagningen påverkas negativt av stressade sjuksköterskor. För att komma till rätta med sjuksköterskebristen på akutmottagningar så är det av betydelse för sjukhusledningen att arbeta preventivt mot stressade sjuksköterskor.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Questa tesi riguarda il problema della schedulazione degli interventi nel blocco operatorio di un presidio ospedaliero, noto anche come Operating Theatre Planning & Scheduling. Il blocco operatorio è la struttura che eroga servizi a più alto impatto sui costi di un presidio ospedaliero ed è legato ad attività ad alto rischio. E' quindi fondamentale gestire in modo ottimale questa risorsa. In questa tesi, si considera come caso studio l'applicazione reale di un presidio ospedaliero dell'Emilia Romagna con un orizzonte temporale di una settimana, ovvero la cosiddetta programmazione operativa. L'obiettivo è quello di ottenere un utilizzo efficiente del blocco operatorio, garantendo al contempo la priorità agli interventi più urgenti. Data la complessità del problema, vengono proposti algoritmi euristici che permettano di ottenere buone soluzioni in tempi di calcolo ridotti. Studi precedenti hanno infatti evidenziato la difficoltà di trovare soluzioni ottime al problema, mediante l'utilizzo di solver commerciali per modelli di Programmazione Lineare Intera, senza introdurre ipotesi semplificative. Sono stati elaborati tre algoritmi euristici costruttivi di tipo multi-start che permettono di generare soluzioni ammissibili con diverse caratteristiche. Gli algoritmi si differenziano principalmente per le modalità con cui collocano gli interventi nel tempo disponibile delle risorse (induction room, operating room, recovery room), cercando di migliorarne l’utilizzazione e dando priorità ai pazienti più urgenti. Gli algoritmi sono stati implementati utilizzando il linguaggio JAVA e sono stati testati su istanze realistiche fornite dal presidio ospedaliero. I risultati hanno evidenziato un alto grado di utilizzazione delle sale operatorie, un fattore molto rilevante per una ottimale gestione del blocco operatorio. E' stata, infine, svolta un'analisi di sensitività alla variabilità delle durate.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Type 1 neurofibromatosis is a relatively common inherited disease of the nervous system, with a frequency of almost 1 in 3000. It is associated with neurofibromas of various sites. Our case report is about the surgical management of a giant neurofibroma of the right gluteal fold in a 46-year-old male with NF1. The patient presented with increasing edema and accelerated growth of the mass; he underwent percutaneous embolization of lesion vessels that induced necrosis of the neurofibroma. The patient was taken to the operating room, where surgical resection of the bulk of the lesion was undertaken. The postoperative course was complicated by delayed wound closure managed with antibiotics and vacuum-assisted wound closure. Giant neurofibromas similar to this tumor require complex preoperative, intraoperative and postoperative management strategies. Surgical debulk is best managed with preoperative percutaneous embolization that help to avoid surgical bleeding. Postoperative delayed wound closure was managed with the application of negative pressure in a closed environment that triggers granulation and tissue formation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Single electron transistors are fabricated on single Si nanochains, synthesised by thermal evaporation of SiO solid sources. The nanochains consist of one-dimensional arrays of ~10nm Si nanocrystals, separated by SiO 2 regions. At 300 K, strong Coulomb staircases are seen in the drain-source current-voltage (I ds-V ds) characteristics, and single-electron oscillations are seen in the drain-source current-gate voltage (I ds-V ds) characteristics. From 300-20 K, a large increase in the Coulomb blockade region is observed. The characteristics are explained using singleelectron Monte Carlo simulation, where an inhomogeneous multiple tunnel junction represents a nanochain. Any reduction in capacitance at a nanocrystal well within the nanochain creates a conduction " bottleneck", suppressing current at low voltage and improving the Coulomb staircase. The single-electron charging energy at such an island can be very high, ~20k BT at 300 K. © 2012 The Japan Society of Applied Physics.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We report on the material growth and device performance characterization of a strain-compensated In0.54Ga0.46As/In0.51Al0.49As quantum cascade laser at lambda similar to 8 mu m. For 2 mu s pulse at a 5 kHz repetition rate, laser action is achieved up to room temperature (30 degrees C). The tuning coefficient d lambda/dT is 1.37 nm K-1 between 83 K and 163 K and 0.60 nm K-1 in the range from 183 K to 303 K. The peak output power is reported to be similar to 11.3 mW per facet at 293 K and the corresponding threshold current density is 5.69 kA cm(-2).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

X-ray diffraction, as an effective probe and simple method, is used to ascertain the precise control of the epilayer thickness and composition. Intersubband absorption from the whole structure of the QC laser is used to monitor the wavelength of the QC laser and the material quality. Path for growth of high-quality InP-based InGaAs/InAlAs quantum cascade laser material is realized. The absorption between two quantized energy levels is achieved at similar to4.7 mum. Room temperature laser action is achieved at lambda approximate to 5.1 - 5.2 mum. For some devices, if the peak output power is kept at 2 mW, quasi-continuous wave operation at room temperature can persist for more than I It. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Quantum cascade (QC) lasers based on strain-compensated InxGa(1-x)As/InyAl(1-y)As grown on InP substrate using molecular beam epitaxy is reported. The epitaxial quality is demonstrated by the abundant narrow satellite peaks of double-crystal X-ray diffraction and cross-section transmission electron microscopy of the QC laser wafer. Laser action in quasi-continuous wave operation is achieved at lambda approximate to 3.6-3.7 mum at room temperature (34 degreesC) for 20 mum x 1.6 mm devices, with peak output powers of similar to 10.6mW and threshold current density of 2.7kA/cm(2) at this temperature. (C) 2000 Published by Elsevier Science B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a strain-compensated InP-based InGaAs/InAlAs photovoltaic quantum cascade detector grown by solid source molecular beam epitaxy. The detector is based on a vertical intersubband transition and electron transfer on a cascade of quantum levels which is designed to provide longitudinal optical phonon extraction stairs. By careful structure design and growth, the whole epilayer has a residual strain toward InP substrate of only -2.8 x 10(-4). A clear narrow band detection spectrum centered at 4.5 mu m has been observed above room temperature for a device with 200 x 200 mu m(2) square mesa.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The single electron transistor (SET) is a Coulomb blockade device, whose operation is based on the controlled manipulation of individual electrons. Single electron transistors show immense potential to be used in future ultra lowpower devices, high density memory and also in high precision electrometry. Most SET devices operate at cryogenic temperatures, because the charging energy is much smaller than the thermal oscillations. The room temperature operation of these devices is possible with sub- 10nm nano-islands due to the inverse dependance of charging energy on the radius of the conducting nano-island. The fabrication of sub-10nm features with existing lithographic techniques is a technological challenge. Here we present the results for the first room temperature operating SET device fabricated using Focused Ion Beam deposition technology. The SET device, incorporates an array of tungsten nano-islands with an average diameter of 8nm. The SET devices shows clear Coulomb blockade for different gate voltages at room temperature. The charging energy of the device was calculated to be 160.0 meV; the capacitance per junction was found to be 0.94 atto F; and the tunnel resistance per junction was calculated to be 1.26 G Ω. The tunnel resistance is five orders of magnitude larger than the quantum of resistance (26 k Ω) and allows for the localization of electrons on the tungsten nano-island. The lower capacitance of the device combined with the high tunnel resistance, allows for the Coulomb blockade effects observed at room temperature. Different device configurations, minimizing the total capacitance of the device have been explored. The effect of the geometry of the nano electrodes on the device characteristics has been presented. Simulated device characteristics, based on the soliton model have been discussed. The first application of SET device as a gas sensor has been demonstrated.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The single-electron transistor (SET) is one of the best candidates for future nano electronic circuits because of its ultralow power consumption, small size and unique functionality. SET devices operate on the principle of Coulomb blockade, which is more prominent at dimensions of a few nano meters. Typically, the SET device consists of two capacitively coupled ultra-small tunnel junctions with a nano island between them. In order to observe the Coulomb blockade effects in a SET device the charging energy of the device has to be greater that the thermal energy. This condition limits the operation of most of the existing SET devices to cryogenic temperatures. Room temperature operation of SET devices requires sub-10nm nano-islands due to the inverse dependence of charging energy on the radius of the conducting nano-island. Fabrication of sub-10nm structures using lithography processes is still a technological challenge. In the present investigation, Focused Ion Beam based etch and deposition technology is used to fabricate single electron transistors devices operating at room temperature. The SET device incorporates an array of tungsten nano-islands with an average diameter of 8nm. The fabricated devices are characterized at room temperature and clear Coulomb blockade and Coulomb oscillations are observed. An improvement in the resolution limitation of the FIB etching process is demonstrated by optimizing the thickness of the active layer. SET devices with structural and topological variation are developed to explore their impact on the behavior of the device. The threshold voltage of the device was minimized to ~500mV by minimizing the source-drain gap of the device to 17nm. Vertical source and drain terminals are fabricated to realize single-dot based SET device. A unique process flow is developed to fabricate Si dot based SET devices for better gate controllability in the device characteristic. The device vi parameters of the fabricated devices are extracted by using a conductance model. Finally, characteristic of these devices are validated with the simulated data from theoretical modeling.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Increased pressure to control costs and increased competition has prompted health care managers to look for tools to effectively operate their institutions. This research sought a framework for the development of a Simulation-Based Decision Support System (SB-DSS) to evaluate operating policies. A prototype of this SB-DSS was developed. It incorporates a simulation model that uses real or simulated data. ER decisions have been categorized and, for each one, an implementation plan has been devised. Several issues of integrating heterogeneous tools have been addressed. The prototype revealed that simulation can truly be used in this environment in a timely fashion because the simulation model has been complemented with a series of decision-making routines. These routines use a hierarchical approach to organize the various scenarios under which the model may run and to partially reconfigure the ARENA model at run time. Hence, the SB-DSS tailors its responses to each node in the hierarchy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aim To provide an overview of key governance matters relating to medical device trials and practical advice for nurses wishing to initiate or lead them. Background Medical device trials, which are formal research studies that examine the benefits and risks of therapeutic, non-drug treatment medical devices, have traditionally been the purview of physicians and scientists. The role of nurses in medical device trials historically has been as data collectors or co-ordinators rather than as principal investigators. Nurses more recently play an increasing role in initiating and leading medical device trials. Review Methods A review article of nurse-led trials of medical devices. Discussion Central to the quality and safety of all clinical trials is adherence to the International Conference on Harmonization Guidelines for Good Clinical Practice, which is the internationally-agreed standard for the ethically- and scientifically-sound design, conduct and monitoring of a medical device trial, as well as the analysis, reporting and verification of the data derived from that trial. Key considerations include the class of the medical device, type of medical device trial, regulatory status of the device, implementation of standard operating procedures, obligations of the trial sponsor, indemnity of relevant parties, scrutiny of the trial conduct, trial registration, and reporting and publication of the results. Conclusion Nurse-led trials of medical devices are demanding but rewarding research enterprises. As nursing practice and research increasingly embrace technical interventions, it is vital that nurse researchers contemplating such trials understand and implement the principles of Good Clinical Practice to protect both study participants and the research team.