988 resultados para multimode-interference-type device


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although fiber Bragg gratings (FBGs) have been widely used as advanced optical sensors, the cross-sensitivity between temperature and strain has complicated independent measurement procedures for these two measurands. We report here, for the first time to our knowledge, the results of a systematic investigation of the dependence of both temperature and strain sensitivities on the grating type, including the well-known Type I, Type IIA, and a new type which we have designated Type IA, using both hydrogen-free and hydrogenated B/Ge codoped fibers. We have identified distinct sensitivity characteristics for each grating type, and we have utilised them to implement a novel dual-grating, dual-parameter sensor device with performance superior to that of previously reported grating-based structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We introduce a robot-safety device system attended by two different repairmen. The twin system is characterized by the natural feature of cold standby and by an admissible “risky” state. In order to analyse the random behaviour of the entire system (robot, safety device, repair facility) we employ a stochastic process endowed with probability measures satisfying general Hokstad-type differential equations. The solution procedure is based on the theory of sectionally holomorphic functions, characterized by a Cauchy-type integral defined as a Cauchy principal value in double sense. An application of the Sokhotski-Plemelj formulae determines the long-run availability of the robot-safety device. Finally, we consider the particular but important case of deterministic repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A multimode microfiber (MMMF)-based dual Mach-Zehnder interferometer (MZI) is proposed and demonstrated for simultaneous measurement of refractive index (RI) and temperature. By inserting a section of MMMFsupporting a few modes in the sensing arm of the MZI setup, an inline interference between the fundamental mode and the high-order mode of MMMF, as well as the interference between the high-order mode of MMMF and the reference arm, i.e., the dual MZI, is realized. Due to different interference mechanisms, the former interferometer achieves RI sensitivity of 2576.584 nm/RIU and temperature sensitivity of 0.193 nm/°C, while the latter one achieves RI sensitivity of 1001.864 nm/RIU and temperature sensitivity of 0.239 nm/°C, demonstrating the ability to attain highly accurate multiparameter measurements. © 2014 Optical Society of America.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The focusing of multimode laser diode beams is probably the most significant problem that hinders the expansion of the high-power semiconductor lasers in many spatially-demanding applications. Generally, the 'quality' of laser beams is characterized by so-called 'beam propagation parameter' M2, which is defined as the ratio of the divergence of the laser beam to that of a diffraction-limited counterpart. Therefore, M2 determines the ratio of the beam focal-spot size to that of the 'ideal' Gaussian beam focused by the same optical system. Typically, M2 takes the value of 20-50 for high-power broad-stripe laser diodes thus making the focal-spot 1-2 orders of magnitude larger than the diffraction limit. The idea of 'superfocusing' for high-M2 beams relies on a technique developed for the generation of Bessel beams from laser diodes using a cone-shaped lens (axicon). With traditional focusing of multimode radiation, different curvatures of the wavefronts of the various constituent modes lead to a shift of their focal points along the optical axis that in turn implies larger focal-spot sizes with correspondingly increased values of M2. In contrast, the generation of a Bessel-type beam with an axicon relies on 'self-interference' of each mode thus eliminating the underlying reason for an increase in the focal-spot size. For an experimental demonstration of the proposed technique, we used a fiber-coupled laser diode with M2 below 20 and an emission wavelength in ~1μm range. Utilization of the axicons with apex angle of 140deg, made by direct laser writing on a fiber tip, enabled the demonstration of an order of magnitude decrease of the focal-spot size compared to that achievable using an 'ideal' lens of unity numerical aperture. © 2014 SPIE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les patients diabétiques de type 1 (DT1) ont avantage à avoir un bon contrôle glycémique pour réduire les effets négatifs à court et long terme d’un mauvais contrôle glycémique sur leur santé. Pour contrôler leur glycémie, ils doivent prendre de l’insuline, mais il est aussi recommandé qu’ils aient de bonnes habitudes de vie comme une nutrition appropriée et une pratique adéquate d’activité physique. Par contre, les patients DT1 ne suivent généralement pas les recommandations en activité physique et une partie du problème vient de leurs barrières personnelles à un style de vie actif, telle la peur des hypoglycémies. L’utilisation de la pompe comme traitement à l’insuline aide à mieux contrôler la glycémie, plus précisément l’hémoglobine glyquée, que les injections d’insuline, et le dispositif est de plus en plus prescrit chez les enfants et adolescents. Par contre, son impact sur la pratique des activités sédentaire et physique n’est pas encore bien connu. L’objectif de la présente étude est donc de révéler le profil d’activité physique complet, incluant les barrières à l’exercice et les habitudes de vie des parents, des enfants et adolescents DT1, selon leur type de traitement à l’insuline (pompe ou injections). L’étude a été conduite à la clinique d’endocrinologie du Centre hospitalier universitaire de Sainte-Justine (Montréal, Canada). Un questionnaire auto-administré a été complété par 188 patients DT1 âgés de 6 à 17 ans et un de leurs parents. Soixante pourcent des patients étaient des utilisateurs de la pompe à insuline. Il n’y avait pas de différence significative pour aucune des composantes du profil d’activité physique, des habitudes sédentaires et des barrières à l’exercice entre les patients DT1 utilisant les injections et ceux utilisant la pompe. La peur de faire des hypoglycémies était la barrière à l’activité physique principale pour les deux groupes de traitement. Les adolescents dont les parents pratiquaient une plus grande variété d’activités physiques faisaient plus d’activité physique d’intensité moyenne à élevée et passaient moins de temps devant les écrans. En conclusion, le type de traitement n’était pas associé à un style de vie plus sain chez les patients pédiatriques DT1, mais un profil d’activité physique parental varié était le facteur principal d’intérêt pour des habitudes de vie plus saines chez les adolescents DT1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A compact and low cost fiber sensor based on single multimode microfiber with Fresnel reflection is proposed and demonstrated for simultaneous measurement of refractive index and temperature. The sensor is fabricated with two simple steps including fiber tapering and then fiber endface cleaving. The reflection spectrum is an intensity modulated interference spectrum, as the tapered fiber generates interference pattern and the cleaved endface provides intensity modulation. By demodulating the fringe power and free spectrum range (FSR) of the spectrum, RI sensitivities of -72.247dB/RIU and 68.122nm/RIU, as well as temperature sensitivities of 0.0283dB/degrees C and -17pm/degrees C are obtained. Further, the sensing scheme could also provide the feasibility to construct a more compact sensing probe for dual-paramters measurement, which has great potential in bio/chemical detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aurivillius phase Bi 5Ti 3Fe 0.7Co 0.3O 15 (BTF7C3O) thin films on α-quartz substrates were fabricated by a chemical solution deposition method and the room temperature ferroelectric and magnetic properties of this candidate multiferroic were compared with those of thin films of Mn 3 substituted, Bi 5Ti 3Fe 0.7Mn 0.3O 15 (BTF7M3O). Vertical and lateral piezoresponse force microscopy (PFM) measurements of the films conclusively demonstrate that BTF7C3O and BTF7M3O thin films are piezoelectric and ferroelectric at room temperature, with the major polarization vector in the lateral plane of the films. No net magnetization was observed for the in-plane superconducting quantum interference device (SQUID) magnetometry measurements of BTF7M3O thin films. In contrast, SQUID measurements of the BTF7C3O films clearly demonstrated ferromagnetic behavior, with a remanent magnetization, B r, of 6.37 emu/cm 3 (or 804 memu/g), remanent moment 4.99 × 10 -5 emu. The BTF7C3O films were scrutinized by x-ray diffraction, high resolution transmission electron microscopy, scanning transmission electron microscopy, and energy dispersive x-ray analysis mapping to assess the prospect of the observed multiferroic properties being intrinsic to the main phase. The results of extensive micro-structural phase analysis demonstrated that the BTF7C3O films comprised of a 3.95 Fe/Co-rich spinel phase, likely CoFe 2 - xTi xO 4, which would account for the observed magnetic moment in the films. Additionally, x-ray magnetic circular dichroism photoemission electron microscopy (XMCD-PEEM) imaging confirmed that the majority of magnetic response arises from the Fe sites of Fe/Co-rich spinel phase inclusions. While the magnetic contribution from the main phase could not be determined by the XMCD-PEEM images, these data however imply that the Bi 5Ti 3Fe 0.7Co 0.3O 15 thin films are likely not single phase multiferroics at room temperature. The PFM results presented demonstrate that the naturally 2D nanostructured Bi 5Ti 3Fe 0.7Co 0.3O 15 phase is a novel ferroelectric and has potential commercial applications in high temperature piezoelectric and ferroelectric memory technologies. The implications for the conclusive demonstration of ferroelectric and ferromagnetic properties in single-phase materials of this type are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis demonstrates a new way to achieve sparse biological sample detection, which uses magnetic bead manipulation on a digital microfluidic device. Sparse sample detection was made possible through two steps: sparse sample capture and fluorescent signal detection. For the first step, the immunological reaction between antibody and antigen enables the binding between target cells and antibody-­‐‑ coated magnetic beads, hence achieving sample capture. For the second step, fluorescent detection is achieved via fluorescent signal measurement and magnetic bead manipulation. In those two steps, a total of three functions need to work together, namely magnetic beads manipulation, fluorescent signal measurement and immunological binding. The first function is magnetic bead manipulation, and it uses the structure of current-­‐‑carrying wires embedded in the actuation electrode of an electrowetting-­‐‑on-­‐‑dielectric (EWD) device. The current wire structure serves as a microelectromagnet, which is capable of segregating and separating magnetic beads. The device can achieve high segregation efficiency when the wire spacing is 50µμm, and it is also capable of separating two kinds of magnetic beads within a 65µμm distance. The device ensures that the magnetic bead manipulation and the EWD function can be operated simultaneously without introducing additional steps in the fabrication process. Half circle shaped current wires were designed in later devices to concentrate magnetic beads in order to increase the SNR of sample detection. The second function is immunological binding. Immunological reaction kits were selected in order to ensure the compatibility of target cells, magnetic bead function and EWD function. The magnetic bead choice ensures the binding efficiency and survivability of target cells. The magnetic bead selection and binding mechanism used in this work can be applied to a wide variety of samples with a simple switch of the type of antibody. The last function is fluorescent measurement. Fluorescent measurement of sparse samples is made possible of using fluorescent stains and a method to increase SNR. The improved SNR is achieved by target cell concentration and reduced sensing area. Theoretical limitations of the entire sparse sample detection system is as low as 1 Colony Forming Unit/mL (CFU/mL).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les patients diabétiques de type 1 (DT1) ont avantage à avoir un bon contrôle glycémique pour réduire les effets négatifs à court et long terme d’un mauvais contrôle glycémique sur leur santé. Pour contrôler leur glycémie, ils doivent prendre de l’insuline, mais il est aussi recommandé qu’ils aient de bonnes habitudes de vie comme une nutrition appropriée et une pratique adéquate d’activité physique. Par contre, les patients DT1 ne suivent généralement pas les recommandations en activité physique et une partie du problème vient de leurs barrières personnelles à un style de vie actif, telle la peur des hypoglycémies. L’utilisation de la pompe comme traitement à l’insuline aide à mieux contrôler la glycémie, plus précisément l’hémoglobine glyquée, que les injections d’insuline, et le dispositif est de plus en plus prescrit chez les enfants et adolescents. Par contre, son impact sur la pratique des activités sédentaire et physique n’est pas encore bien connu. L’objectif de la présente étude est donc de révéler le profil d’activité physique complet, incluant les barrières à l’exercice et les habitudes de vie des parents, des enfants et adolescents DT1, selon leur type de traitement à l’insuline (pompe ou injections). L’étude a été conduite à la clinique d’endocrinologie du Centre hospitalier universitaire de Sainte-Justine (Montréal, Canada). Un questionnaire auto-administré a été complété par 188 patients DT1 âgés de 6 à 17 ans et un de leurs parents. Soixante pourcent des patients étaient des utilisateurs de la pompe à insuline. Il n’y avait pas de différence significative pour aucune des composantes du profil d’activité physique, des habitudes sédentaires et des barrières à l’exercice entre les patients DT1 utilisant les injections et ceux utilisant la pompe. La peur de faire des hypoglycémies était la barrière à l’activité physique principale pour les deux groupes de traitement. Les adolescents dont les parents pratiquaient une plus grande variété d’activités physiques faisaient plus d’activité physique d’intensité moyenne à élevée et passaient moins de temps devant les écrans. En conclusion, le type de traitement n’était pas associé à un style de vie plus sain chez les patients pédiatriques DT1, mais un profil d’activité physique parental varié était le facteur principal d’intérêt pour des habitudes de vie plus saines chez les adolescents DT1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an analytical performance investigation of both beamforming (BF) and interference cancellation (IC) strategies for a device-to-device (D2D) communication system underlaying a cellular network with an M-antenna base station (BS). We first derive new closed-form expressions for the ergodic achievable rate for BF and IC precoding strategies with quantized channel state information (CSI), as well as, perfect CSI. Then, novel lower and upper bounds are derived which apply for an arbitrary number of antennas and are shown to be sufficiently tight to the Monte-Carlo results. Based on these results, we examine in detail three important special cases including: high signal-to-noise ratio (SNR), weak interference between cellular link and D2D link, and BS equipped with a large number of antennas. We also derive asymptotic expressions for the ergodic achievable rate for these scenarios. Based on these results, we obtain valuable insights into the impact of the system parameters, such as the number of antennas, SNR and the interference for each link. In particular, we show that an irreducible saturation point exists in the high SNR regime, while the ergodic rate under IC strategy is verified to be always better than that under BF strategy. We also reveal that the ergodic achievable rate under perfect CSI scales as log2M, whilst it reaches a ceiling with quantized CSI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We investigate device-to-device (D2D) communication underlaying cellular networks with M-antenna base stations. We consider both beamforming (BF) and interference cancellation (IC) strategies under quantized channel state information (CSI), as well as, perfect CSI. We derive tight closed-form approximations of the ergodic achievable rate which hold for arbitrary transmit power, location of users and number of antennas. Based on these approximations, we derive insightful asymptotic expressions for three special cases namely high signal-to-noise (SNR), weak interference, and large M. In particular, we show that in the high SNR regime a ceiling effect exists which depends on the received signal-to-interference ratio and the number of antennas. Moreover, the achievable rate scales logarithmically with M. The ergodic achievable rate is shown to scale logarithmically with SNR and the antenna number in the weak interference case. When the BS is equipped with large number of antennas, we find that the ergodic achievable rate under quantized CSI reaches a saturated value, whilst it scales as log2M under perfect CSI.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

End users urgently request using mobile devices at their workplace. They know these devices from their private life and appreciate functionality and usability, and want to benefit from these advantages at work as well. Limitations and restrictions would not be accepted by them. On the contrary, companies are obliged to employ substantial organizational and technical measures to ensure data security and compliance when allowing to use mobile devices at the workplace. So far, only individual arrangements have been presented addressing single issues in ensuring data security and compliance. However, companies need to follow a comprehensive set of measures addressing all relevant aspects of data security and compliance in order to play it safe. Thus, in this paper at first technical architectures for using mobile devices in enterprise IT are reviewed. Thereafter a set of compliance rules is presented and, as major contribution, technical measures are explained that enable a company to integrate mobile devices into enterprise IT while still complying with these rules comprehensively. Depending on the company context, one or more of the technical architectures have to be chosen impacting the specific technical measures for compliance as elaborated in this paper. Altogether this paper, for the first time, correlates technical architectures for using mobile devices at the workplace with technical measures to assure data security and compliance according to a comprehensive set of rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Using modern devices like smartphones and tablets offers a wide variety of advantages; this has made them very popular as consumer devices in private life. Using them in the workplace is also popular. However, who wants to carry around and handle two devices; one for personal use, and one for work-related tasks? That is why “dual use”, using one single device for private and business applications, may represent a proper solution. The result is “Bring Your Own Device,” or BYOD, which describes the circumstance in which users make their own personal devices available for company use. For companies, this brings some opportunities and risks. We describe and discuss organizational issues, technical approaches, and solutions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Numerous applications within the mid- and long-wavelength infrared are driving the search for efficient and cost effective detection technologies in this regime. Theoretical calculations have predicted high performance for InAs/GaSb type-II superlattice structures, which rely on mature growth of III-V semiconductors and offer many levels of freedom in design due to band structure engineering. This work focuses on the fabrication and characterization of type-II superlattice infrared detectors. Standard UV-based photolithography was used combined with chemical wet or dry etching techniques in order to fabricate antinomy-based type-II superlattice infrared detectors. Subsequently, Fourier transform infrared spectroscopy and radiometric techniques were applied for optical characterization in order to obtain a detector's spectrum and response, as well as the overall detectivity in combination with electrical characterization. Temperature dependent electrical characterization was used to extract information about the limiting dark current processes. This work resulted in the first demonstration of an InAs/GaSb type-II superlattice infrared photodetector grown by metalorganic chemical vapor deposition. A peak detectivity of 1.6x10^9 Jones at 78 K was achieved for this device with a 11 micrometer zero cutoff wavelength. Furthermore the interband tunneling detector designed for the mid-wavelength infrared regime was studied. Similar results to those previously published were obtained.