955 resultados para lightning detectors


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Otto geometry of attenuated total reflection (prism-air gap-sample), front illuminated PtSi/Si Schottky barrier detectors are shown to exhibit enhanced photocurrent at surface plasmon resonance in the near infrared region. Correlation of the measured photocurrent with the calculated transmittance of light into the Si substate is demonstrated. The transmittance, which is due to surface plasmon re-radiation, is the optical parameter of principal importance in photosignal generation since the photon energies used here are greater than the silicon intrinsic bandgap. The results presented here indicate clearly the important features in optimizing surface plasmon enhancement in photodetection both above and below the silicon absorption edge.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Calibration of three scintillators (EJ232Q, BC422Q, and EJ410) in a time-of-flight arrangement using a laser drive-neutron source is presented. The three plastic scintillator detectors were calibrated with gamma insensitive bubble detector spectrometers, which were absolutely calibrated over a wide range of neutron energies ranging from sub-MeV to 20 MeV. A typical set of data obtained simultaneously by the detectors is shown, measuring the neutron spectrum emitted from a petawatt laser irradiated thin foil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Micro-Hole & Strip Plate (MHSP) é uma microestrutura desenvolvida recentemente em instituições universitárias portuguesas. Neste trabalho, o seu desempenho como detector para imagiologia é explorado, tendo como objectivo a imagiologia não só de neutrões, mas também de raios X. A aplicação do método da divisão resistiva de carga é aplicada a uma MHSP especialmente desenhada para sensibilidade em posição. Várias abordagens em termos da electrónica de aquisição de sinal são testadas, sem perder de vista a relação desempenho-preço. Resoluções espaciais abaixo de 1 mm foram obtidas com a MHSP a operar em xénon e tetrafluorometano, com um sistema de detecção a um preço modesto quando comparado com as alternativas, e apropriado para inúmeras aplicações em imagiologia de neutrões e de raios X.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents the results on the development of a high pressure Xe gaseous detector envisaging medical imaging. The detector uses two VUV photosensors operating face-to-face, based on the CsI-MHSP with position discrimination capability. The known effect of the charge gain decrease with the gas pressure is compensated with a light gain using the electroluminescence process. Studies of signal amplitude, energy and position resolution are presented. On the second part, gaseous detectors based on THGEM where studied in order to fulfill the requirements of present and future high energy physics experiments. The work is focused on the application of THGEM in RICH detectors elements: a triple THGEM detector using CsI photocathodes in Ne mixtures was suggested. The ion backflow to the photocathode remains a concern and a limitation; to minimize it, the application of a new hole-structure, THCOBRA, was suggested. Preliminary results foresee good perspectives for the successful application of THCOBRA in ion back-flow suppression. This work contains several methods and measurements of the CsI photocathodes behaviour in radiation gaseous detectors. A long discussion on its issues and possible solutions are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As wind power generation undergoes rapid growth, lightning and overvoltage incidents involving wind power plants have come to be regarded as a serious problem. Firstly, lightning location systems are discussed, as well as important parameters regarding lightning protection. Also, this paper presents a case study, based on a wind turbine with an interconnecting transformer, for the study of adequate lightning and overvoltage protection measures. The electromagnetic transients circuit under study is described, and computational results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is concerned with the protection of wind energy systems against the indirect effects of lightning. As wind energy is gaining increasing importance throughout the world, lightning damages involving wind energy systems have come to be regarded with more attention. Nevertheless, there are still very few studies in Portugal regarding lightning protection of wind energy systems using models of the Electro-Magnetic Transients Program (EMTP). Hence, a new case study is presented in this paper, based on a wind turbine with an interconnecting transformer, considering that lightning strikes the soil near the tower at a distance such that galvanic coupling occurs through the grounding electrode. Computer simulations obtained by using EMTP-RV are presented and conclusions are duly drawn. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is concerned with direct or indirect lightning strokes on wind turbines, studying overvoltages and electromagnetic transients. As wind power generation undergoes rapid growth, lightning damages involving wind turbines have come to be regarded with more attention. With the aim of providing further insights into the lightning protection of wind turbines, describing the transient behavior in an accurate way, the restructured version (RV) of the electromagnetic transients program (EMTP) is used in this paper. A new case study is presented with two interconnected wind turbines, considering a direct lightning stroke to the blade or considering that lightning strikes the soil near a tower. Comprehensive computer simulations with EMTP-RV are presented and conclusions are duly drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lightning Fastener Co. Ltd. was a zipper manufacturer located on Niagara Street in St. Catharines. It was founded by Gideon Sundback, the inventor of the modern fastener. Sundback was born in Sweden, but settled in the United States in 1905. It was here that he designed and patented a “separable fastener” in 1913. Although he lived in Hoboken, New Jersey, he decided to establish a manufacturing facility for his invention in Canada, choosing St. Catharines over other locations such as Fort Erie and Hamilton. At the height of its success, the company employed more than 500 people and produced more than 50 million zippers annually. Over time, the company had difficulty remaining competitive and was forced to close in 1981.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En opération depuis 2008, l’expérience ATLAS est la plus grande de toutes les expériences au LHC. Les détecteurs ATLAS- MPX (MPX) installés dans ATLAS sont basés sur le détecteur au silicium à pixels Medipix2 qui a été développé par la collaboration Medipix au CERN pour faire de l’imagerie en temps réel. Les détecteurs MPX peuvent être utilisés pour mesurer la luminosité. Ils ont été installés à seize différents endroits dans les zones expérimentale et technique d’ATLAS en 2008. Le réseau MPX a recueilli avec succès des données indépendamment de la chaîne d’enregistrement des données ATLAS de 2008 à 2013. Chaque détecteur MPX fournit des mesures de la luminosité intégrée du LHC. Ce mémoire décrit la méthode d’étalonnage de la luminosité absolue mesurée avec les détectors MPX et la performance des détecteurs MPX pour les données de luminosité en 2012. Une constante d’étalonnage de la luminosité a été déterminée. L’étalonnage est basé sur technique de van der Meer (vdM). Cette technique permet la mesure de la taille des deux faisceaux en recouvrement dans le plan vertical et horizontal au point d’interaction d’ATLAS (IP1). La détermination de la luminosité absolue nécessite la connaissance précise de l’intensité des faisceaux et du nombre de trains de particules. Les trois balayages d’étalonnage ont été analysés et les résultats obtenus par les détecteurs MPX ont été comparés aux autres détecteurs d’ATLAS dédiés spécifiquement à la mesure de la luminosité. La luminosité obtenue à partir des balayages vdM a été comparée à la luminosité des collisions proton- proton avant et après les balayages vdM. Le réseau des détecteurs MPX donne des informations fiables pour la détermination de la luminosité de l’expérience ATLAS sur un large intervalle (luminosité de 5 × 10^29 cm−2 s−1 jusqu’à 7 × 10^33 cm−2 s−1 .

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within a drift-diffusion model we investigate the role of the self-consistent electric field in determining the impedance field of a macroscopic Ohmic (linear) resistor made by a compensated semi-insulating semiconductor at arbitrary values of the applied voltage. The presence of long-range Coulomb correlations is found to be responsible for a reshaping of the spatial profile of the impedance field. This reshaping gives a null contribution to the macroscopic impedance but modifies essentially the transition from thermal to shot noise of a macroscopic linear resistor. Theoretical calculations explain a set of noise experiments carried out in semi-insulating CdZnTe detectors.