A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters
Data(s) |
2014
|
---|---|
Resumo |
We present a method to reach electric field intensity as high as 400 kV/cm in liquid argon for cathode-ground distances of several millimeters. This can be achieved by suppressing field emission from the cathode, overcoming limitations that we reported earlier. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/68750/1/1748-0221_9_07_P07023.pdf Auger, Martin; Ereditato, Antonio; Göldi, Damian; Janos, Stefan; Kreslo, Igor; Lüthi, Matthias; Rudolf von Rohr, Christoph; Strauss, Thomas; Tolba, Tamer; Weber, Michael (2014). A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters. Journal of instrumentation, 9(07), P07023-P07023. Institute of Physics Publishing IOP 10.1088/1748-0221/9/07/P07023 <http://dx.doi.org/10.1088/1748-0221/9/07/P07023> doi:10.7892/boris.68750 info:doi:10.1088/1748-0221/9/07/P07023 urn:issn:1748-0221 |
Idioma(s) |
eng |
Publicador |
Institute of Physics Publishing IOP |
Relação |
http://boris.unibe.ch/68750/ |
Direitos |
info:eu-repo/semantics/openAccess |
Fonte |
Auger, Martin; Ereditato, Antonio; Göldi, Damian; Janos, Stefan; Kreslo, Igor; Lüthi, Matthias; Rudolf von Rohr, Christoph; Strauss, Thomas; Tolba, Tamer; Weber, Michael (2014). A method to suppress dielectric breakdowns in liquid argon ionization detectors for cathode to ground distances of several millimeters. Journal of instrumentation, 9(07), P07023-P07023. Institute of Physics Publishing IOP 10.1088/1748-0221/9/07/P07023 <http://dx.doi.org/10.1088/1748-0221/9/07/P07023> |
Palavras-Chave | #530 Physics |
Tipo |