981 resultados para laser induced fluorescence detection


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the severity of renal ischemia/reperfusion injury as determined by histology and by laser-induced fluorescence (LIF) with excitation wavelengths of 442 nm and 532 nm. Wistar rats (four groups of six animals) were subjected to left renal warm ischemia for 20, 40, 60 and 80 min followed by 10 min of reperfusion. Autofluorescence was determined before ischemia (control) and then every 5-10 min thereafter. Tissue samples for histology were harvested from the right kidney (control) and from the left kidney after reperfusion. LIF and ischemia time showed a significant correlation (p < 0.0001 and r (2)=0.47, and p=0.006 and r (2)=0.25, respectively, for the excitation wavelengths of 442 nm and 532 nm). Histological scores showed a good correlation with ischemia time (p < 0.0001). The correlations between optical spectroscopy values and histological damage were: LIF at 442 nm p < 0.0001, LIF at 532 nm p=0.001; IFF (peak of back scattered light/LIF) at 442 nm p > 0.05, and IFF at 532 nm p > 0.05. After reperfusion LIF tended to return to preischemic basal levels which occurred in the presence of histological damage. This suggests that factors other than morphological alterations may have a more relevant effect on changes observed in LIF. In conclusion, renal ischemia/reperfusion changed tissue fluorescence induced by laser. The excitation light of 442 nm showed a better correlation with the ischemia time and with the severity of tissue injury.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Steatosis is diagnosed on the basis of the macroscopic aspect of the liver evaluated by the surgeon at the time of organ extraction or by means of a frozen biopsy. In the present study, the applicability of laser-induced fluorescence (LIF) spectroscopy was investigated as a method for the diagnosis of different degrees of steatosis experimentally induced in rats. Rats received a high-lipid diet for different periods of time. The animals were divided into groups according to the degree of induced steatosis diagnosis by histology. The concentration of fat in the liver was correlated with LIF by means of the steatosis fluorescence factor (SFF). The histology classification, according to liver fat concentration was, Severe Steatosis, Moderate Steatosis, Mild Steatosis and Control (no liver steatosis). Fluorescence intensity could be directly correlated with fat content. It was possible to estimate an average of fluorescence intensity variable by means of different confidence intervals (P=95%) for each steatosis group. SFF was significantly higher in the Severe Steatosis group (P < 0.001) compared with the Moderate Steatosis, Mild Steatosis and Control groups. The various degrees of steatosis could be directly correlated with SFF. LIF spectroscopy proved to be a method capable of identifying the degree of hepatic steatosis in this animal model, and has the potential of clinical application for non-invasive evaluation of the degree of steatosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work demonstrates the successful application of automated biocompatible in-tube solid-phase microextraction coupled with liquid chromatography (in-tube SPME/LC) for determination of interferon alpha(2a) (IFN alpha(2a)) in plasma samples for therapeutic drug monitoring. A restricted access material (RAM, protein-coated silica) was employed for preparation of a lab-made biocompatible in-tube SPME capillary that enables the direct injection of biological fluids as well as the simultaneous exclusion of macromolecules by chemical diffusion barrier and drug pre-concentration. The in-tube SPME variables, such as sample volume, draw/eject volume, number of draw-eject cycles, and desorption mode were optimized, to improve the sensitivity of the proposed method. The IFN alpha(2a) analyses in plasma sample were carried out within 25 min (sample preparation and LC analyses). The response of the proposed method was linear over a dynamic range, from 0.06 to 3.0 MIU mL(-1), with correlation coefficient equal to 0.998. The interday precision of the method presented coefficient of variation lower than 8%. The proposed automated method has adequate analytical sensitivity and selectivity for determination of IFN alpha(2a) in plasma samples for therapeutic drug monitoring. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sewage sludge from wastewater treatment contains organic matter and plant nutrients that can play an important role in agricultural production and the maintenance of soil fertility, The present study has aimed to evaluate the degree of humification following sewage sludge application of soil organic matter by laser-induced fluorescence and humic acids using ultraviolet-visible fluorescence, and including comparison with Fourier-transform infrared spectroscopy and elemental analysis. Sewage sludge applications to the soil caused a decrease in the degree of humification of the soil organic matter and humic acids for both a Typic Eutrorthox (clayey) soil and a Typic Haplorthox (sandy) soil of around 14 and 27%, respectively. This effect is probably clue to incorporation of newly formed humic substances from the sewage sludge into the characteristics of less humified material, and to the indigenous soil humic substances. The minor alterations observed in the clay soil probably occurred due to both the greater mineral association, which better stabilized the indigenous soil organic matter, and the higher microbial activity in this soil, which accelerated sewage sludge mineralization. Sewage sludge applications increased the C content for the clay and sandy soils by 7.4 and 15.4 g kg(-1), respectively, suggesting a positive effect on these two soils.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In order to investigate optically excited electronic transport in Er-doped SnO2, thin films are excited with the fourth harmonic of an Nd:YAG laser (266nm) at low temperature, yielding conductivity decay when the illumination is removed. Inspection of these electrical characteristics aims knowledge for electroluminescent devices operation. Based on a proposed model where trapping defects present thermally activated cross section, the capture barrier is evaluated as 140, 108, 100 and 148 meV for doped SnO2, thin films with 0.0, 0.05, 0. 10 and 4.0 at% of Er, respectively. The undoped film has vacancy levels as dominating, whereas for doped films. there are two distinct trapping centers: Er3+ substitutional at Sn lattice sites and Er3+ located at grain boundary. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pulse repetition rates and the number of laser pulses are among the most important parameters that do affect the analysis of solid materials by laser induced breakdown spectroscopy, and the knowledge of their effects is of fundamental importance for suggesting analytical strategies when dealing with laser ablation processes of polymers. In this contribution, the influence of these parameters in the ablated mass and in the features of craters was evaluated in polypropylene and high density polyethylene plates containing pigment-based PbCrO4. Surface characterization and craters profile were carried out by perfilometry and scanning electron microscopy. Area, volume and profile of craters were obtained using Taylor Map software. A laser induced breakdown spectroscopy system consisted of a Q-Switched Nd:YAG laser (1064 nm, 5 ns) and an Echelle spectrometer equipped with ICCD detector were used. The evaluated operating conditions consisted of 10, 25 and 50 laser pulses at 1, 5 and 10 Hz, 250 mJ/pulse (85 J cm(-2)), 2 mu s delay time and 6 mu s integration time gate. Differences in the topographical features among craters of both polymers were observed. The decrease in the repetition rate resulted in irregular craters and formation of edges, especially in polypropylene sample. The differences in the topographical features and ablated masses were attributed to the influence of the degree of crystallinity, crystalline melting temperature and glass transition temperature in the ablation process of the high density polyethylene and polypropylene. It was also observed that the intensities of chromium and lead emission signals obtained at 10 Hz were two times higher than at 5 Hz by keeping the number of laser pulses constant. (C) 2011 Elsevier B. V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the synthesis of Au nanoparticles by 30-fs pulses irradiation of a sample containing HAuCl4 and chitosan, a biopolymer used as reducing agent and stabilizer. We observed that it is a multi-photon induced process, with a threshold irradiance of 3.8 x 10(11) W/cm(2) at 790 nm. By transmission electron microscopy we observed nanoparticles from 8 to 50 nm with distinct shapes. Infrared spectroscopy indicated that the reduction of gold and consequent production of nanoparticles is related to the fs-pulse induced oxidation of hydroxyl to carbonyl groups in chitosan. (C) 2011 Optical Society of America

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of laser focusing and fluence on LIBS analysis of pellets of plant leaves was evaluated. A Q-switched Nd:YAG laser (5ns, 10Hz, 1064nm) was used and the emission signals were collected by lenses into an optical fiber coupled to a spectrometer with Echelle optics and ICCD. Data were acquired from the accumulation of 20 laser pulses at 2.0 mu s delay and 5.0 mu s integration time gate. The emission signal intensities increased with both laser fluence and spot size. Higher sensitivities for Ca, K, Mg, P, Al, B, Cu, Fe, Mn, and Zn determinations were observed for fluences in the range from 25 to 60Jcm(-2). Coefficients of variation of site-to-site measurements were generally lower than 10% (n=30 sites, 20 laser pulses/site) for a fluence of 50Jcm(-2) and 750 mu m spot size. For most elements, there is an indication that accuracy is improved with higher fluences. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the control of Au nanoparticle (NP) formation by using shaped 30 fs pulses, in a solution containing HAuCl4 and chitosan. By using a sinusoidal spectral phase, a periodic train of pulses is generated. When the period of the pulse train matches certain Raman resonances of chitosan, the reducing agent of the process, an enhancement of the Au NP formation is observed. Theoretical quantum chemical calculations indicate that the outer groups of the chitosan are mostly influenced by low Raman frequencies, which is in reasonably agreement with the experimental data and indicates an enhancement in the Au NP formation as the pulse train period increases (low frequency).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During recent years a consistent number of central nervous system (CNS) drugs have been approved and introduced on the market for the treatment of many psychiatric and neurological disorders, including psychosis, depression, Parkinson disease and epilepsy. Despite the great advancements obtained in the treatment of CNS diseases/disorders, partial response to therapy or treatment failure are frequent, at least in part due to poor compliance, but also genetic variability in the metabolism of psychotropic agents or polypharmacy, which may lead to sub-therapeutic or toxic plasma levels of the drugs, and finally inefficacy of the treatment or adverse/toxic effects. With the aim of improving the treatment, reducing toxic/side effects and patient hospitalisation, Therapeutic Drug Monitoring (TDM) is certainly useful, allowing for a personalisation of the therapy. Reliable analytical methods are required to determine the plasma levels of psychotropic drugs, which are often present at low concentrations (tens or hundreds of nanograms per millilitre). The present PhD Thesis has focused on the development of analytical methods for the determination of CNS drugs in biological fluids, including antidepressants (sertraline and duloxetine), antipsychotics (aripiprazole), antiepileptics (vigabatrin and topiramate) and antiparkinsons (pramipexole). Innovative methods based on liquid chromatography or capillary electrophoresis coupled to diode-array or laser-induced fluorescence detectors have been developed, together with the suitable sample pre-treatment for interference removal and fluorescent labelling in case of LIF detection. All methods have been validated according to official guidelines and applied to the analysis of real samples obtained from patients, resulting suitable for the TDM of psychotropic drugs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Advances in metastability exchange optical pumping (MEOP) of 3He at high laser powers, with its various applications, but also at high gas pressures p3 and high magnetic field strengths B, have provided strong motivation for revisiting the understanding and for investigating the limitations of this powerful technique. For this purpose, we present systematic experimental and theoretical studies of efficiency and of relaxation mechanisms in B≤30 mT and p3=0.63−2.45 mbar. 3He nuclear polarisation is measured by light absorption in longitudinal configuration where weak light beams at 1083 nm parallel to magnetic field and cell axis with opposite circular polarisations are used to probe the distribution of populations in the metastable state. This method is systematically tested to evaluate potential systematic biases and is shown to be reliable for the study of OP dynamics despite the redistribution of populations by OP light. Nuclear polarisation loss associated to the emission of polarised light by the plasma discharge used for MEOP is found to decrease above 10 mT, as expected, due to hyperfine decoupling in highly excited states. However, this does not lead to improved MEOP efficiency at high laser power. We find clear evidence of additional laser-induced relaxation instead. The strong OP-enhanced polarisation losses, currently limiting MEOP performances, are quantitatively investigated using an angular momentum budget approach and a recently developed comprehensive model that describes the combined effects of OP, ME and relaxation, validated by comparison to experimental results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Das Hydroxyl Radikal ist, auf globalem Maßstab, das bedeutendste Oxidant in der Atmosphäre. Es initiiert den Abbauprozess vieler, teilweise schädlicher, Spurengase und insbesondere den von flüchtigen Kohlenwasserstoffen (VOC). Die OH Konzentration ist somit ein gutes Maß für die augenblickliche Selbstreinigungskapazität der Atmosphäre. Messungen zu nächtlicher Zeit mit LIF-FAGE-Instrumenten (engl.: laser-induced fluorescence - fluorescence assay by gas expansion) haben Konzentrationen des Hydroxylradikals (OH) ergeben, die signifikant höher waren, als sich mit der bekannten Chemie erklären ließ. Um herauszufinden, ob ein solches Signal wirklich atmosphärisches OH ist oder von einer störenden Spezies stammt, die im Messinstrument OH produziert, wurde das LIF-FAGE-Instrument des Max-Planck-Instituts für Chemie (MPIC) im Rahmen dieser Doktorarbeit modifiziert und getestet. Dazu wurde ein so genannter Inlet Pre-Injector (IPI) entwickelt, mit dem in regelmäßigen Abständen ein OH-Fänger in die Umgebungsluft abgegeben werden kann, bevor das OH vom Instrument erfasst wird. Mit dieser Technik ist es möglich, ein Hintergrund-OH (OHbg), d. h. ein im Instrument erzeugtes OH-Signal, vom gemessenen OH-Gesamtsignal (OHtot) zu trennen. Die Differenz zwischen OHtot und OHbg ist die atmosphärische OH-Konzentration (OHatm). Vergleichsmessungen mit der hier entwickelten Technik, dem IPI, in zwei verschiedenen Umgebungen mit Instrumenten basierend auf Massenspektrometrie mit chemischer Ionisation (CIMS, engl.: chemical ionization mass spectrometry) als alternativer Methode des OH-Nachweises, zeigten eine weitgehende Übereinstimmung. Eine umfassende Beschreibung des Systems zur Ermittlung der Ursache des OHbg hat ergeben, dass es weder von einem Artefakt des Instruments noch von hinlänglich bekannten und beschriebenen LIF-FAGE-Interferenzen stammt. Zur Bestimmung der Spezies, die das OHbg-Signal verursacht, wurden verschiedene Laborstudien durchgeführt. Die Arbeit im Rahmen dieser Doktorarbeit hat ergeben, dass das LIF-FAGE-Instrument leicht auf OH reagiert, das beim monomolekularen Zerfall stabilisierter Criegee-Intermediate (SCI) im Niederdruckbereich des Instruments gebildet wird. Criegee-Intermediate oder Carbonyloxide entstehen bei der Ozonolyse ungesättigter flüchtiger Kohlenwasserstoffverbindungen (VOC, engl.: volatile organic compounds) und können daher in der Umgebungsluft vorkommen. Anhand von Tests mit verschiedenen Verweilzeiten der SCI im Niederdruckbereich des Instruments in Verbindung mit einem detaillierten Modell mit der neuesten SCI-Chemie wurde die monomolekulare Zerfallsgeschwindigkeit von 20  10 s-1 für den syn-Acetaldehyd-Oxykonformer bestimmt. Der in Feldkampagnen gemessene OHbg-Wert wurde dahingehend untersucht, ob SCI die Quelle des beobachteten Hintergrund-OH im Feld sein könnten. Das Budget für die SCI-Konzentration, das für die Kampagnen HUMPPA-COPEC 2010 und HOPE 2012 berechnet wurde, ergab eine SCI-Konzentration zwischen ca. 103 und 106 Molekülen pro cm3. In der Kampagne HUMPPA-COPEC 2010 ergab die Schwefelsäurekonzentration, dass die OH-Oxidation von SO2 allein die gemessene H2SO4-Konzentration nicht erklären konnte. In dieser Arbeit konnte gezeigt werden, dass das Hintergrund-OH mit dieser ungeklärten Produktionsrate von H2SO4 korreliert und somit die Oxidation von SO2 durch SCI als mögliche Erklärung in Frage kommt. Ferner korreliert das Hintergrund-OH in der Kampagne HOPE 2012 mit dem Produkt aus Ozon und VOC und konnte mit SO2 als SCI Fänger entfernt werden. Qualitativ zeigen wir somit, dass das in der Umgebungsluft gemessene Hintergrund-OH wahrscheinlich durch den monomolekularen Zerfall von SCI verursacht wird, doch sind weitere Studien notwendig, um die quantitativen Beziehung für diese Spezies und dem Hintergrund-OH in unserem Instrument zu bestimmen.