1000 resultados para infiltration test


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current visceral leishmaniasis (VL) control programs in Brazil include the infected dog elimination but, despite this strategy, the incidence of human VL is still increasing. One of the reasons is the long delay between sample collection, analysis, control implementation and the low sensitivity of diagnostic tests. Due to the high prevalence of asymptomatic dogs, the diagnosis of these animals is important considering their vector infection capacity. Hence, a rapid and accurate diagnosis of canine visceral leishmaniasis is essential for an efficient surveillance program. In this study we evaluated the performance of rK39 antigen in an immunochromatographic format to detect symptomatic and asymptomatic Leishmania chagasi infection in dogs and compared the results with those using a crude antigen ELISA. The sensitivity of rK39 dipstick and ELISA were 83% vs. 95%, respectively, while the specificity was both 100%. Our results also demonstrated that the dipstick test was able to detect infected dogs presenting different clinical forms. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The objective of this study was to verify the influence of test environment on the flexural strength of dental porcelains with distinct microstructures. Material and Methods: Disk-shaped specimens from three dental porcelains with distinct leucite content (VM: zero; CE: 12; NS: 22 vol%) were manufactured and tested for biaxial flexural strength in air and immersed in artificial saliva. The results were analyzed by means of two-way ANOVA and Tukey`s test (alpha = 0.05). Results: The flexural strength (MPa) obtained for ambient air and artificial saliva environments, respectively, were: 110.0 +/- 16.0 and 81.5 +/- 10.8 for VM; 51.9 +/- 4.0 and 42.0 +/- 4.7 for CE; 72.0 +/- 11.5 and 63.6 +/- 5.8 for NS. A numerical decrease in the mean flexural strength was observed for all groups when specimens were tested under artificial saliva; however, the difference was only statistically significant for VM. Conclusions: The results indicate that the effect of water immersion on the flexural strength of dental porcelains varies according to their leucite content, as only the material without leucite in its microstructure (VM) showed significant strength degradation when tested under water.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here the existence of a novel subset of langerin (CD207)-positive, immature dendritic cells (DCs) (CD83(neg)) abundantly infiltrating Epstein Barr virus (EBV)-infected areas in tonsil, Hodgkin lymphoma and nasopharyngeal carcinoma. These CD207(+) DCs differ from conventional epidermal Langerhans cells in their lack of CD1a and CCR6 and their unusual tissue localization. CD207(+) DC infiltration strongly correlates with EBV infection because it was neither detected in EBV negative specimens nor in tissues infected with other human viruses. These immature DCs might represent good candidates for induction of the EBV-specific immune response.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the influence of two surface sealants (BisCover/Single Bond) and three application techniques (unsealed/conventional/co-polymerization) on the roughness of two composites (Filtek Z250/Z350) after the toothbrushing test. Methods: Seventy-two rectangular specimens (5 mm x 10 mm x 3 mm) were fabricated and assigned into 12 groups (n = 6). Each sample was subjected to three random roughness readings at baseline, after 100,000 (intermediate), and 200,000 (final) toothbrushing strokes. Roughness (R) at each stage was obtained by the arithmetic mean of the reading of each specimen. Sealant removal was qualitatively examined (optical microscope) and classified into scores (0-3). Data were analyzed by Student`s paired t-test, two-way ANOVA/Tukey`s test, and by Wilcoxon, Kruskal-Wallis and Miller`s test (alpha = 0.05). Results: Z250 groups at baseline did not differ statistically from each other. Unsealed Z350 at baseline had lower R values. All the unsealed groups presented gradual decrease in R from baseline to final brushing. From baseline to the inter-mediate stage, Z250 co-polymerized groups presented a significant reduction in R (score 3). Conventionally sealed groups had no significant changes in R (scores 2-0.8). From baseline to the intermediate stage, the conventionally sealed Z350 Single Bond group had an increase in R (score 1.5). In the final stage, all the conventionally sealed groups presented a reduction in R (scores 0.7-0). Co-polymerized Single Bond groups had a significant reduction in R (scores 2.5-2.7), and co-polymerized BisCover groups an increase in R (scores 2.8-3). Conclusions: At any brushing stage, sealed composites presented superior performance when compared with unsealed composites. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The temperature of different refrigerant sprays (Endo-Ice, Endo-Frost, Coolermatic and Sprayon Contact and Tuner Cleaner) used as pulpal tests were evaluated in vitro. A thermocouple placed inside the pulp chamber of a maxillary central incisor was used to register the temperature changes when the refrigerant sprays were applied with a cotton swab, for 10 s. Results indicate that Endo-Ice and Endo-Frost presented the lowest temperatures among the refrigerant sprays tested. Temperatures measured inside the pulp chamber, however, were statistically similar in all groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sediment mobility measurements with a horizontal sand bed under non-breaking waves are reported. Conditions include no seepage and steady downward seepage corresponding to head gradients up to 2.5. The results indicate that infiltration tends to inhibit sediment mobility for a horizontal bcd of 0.2 mm quartz sand exposed to moderated wave induced bed shear stresses. The effect is weak for the parameter range of the present study. The two opposing effects of shear stress increase due to boundary layer thinning and the stabilizing downward drag are successfully accounted for through the modified Shields parameter of Nielsen [Nielsen, P., 1997. Coastal groundwater dynamics. Proc. Coastal Dynamics '97, Plymouth, ASCE, Dp, 546-555] using coefficients derived from independent studies. That is, from the shear stress experiments of Conley [Conley, D.C., 1993. Ventilated oscillatory boundary layers. PhD Thesis, University of California, San Diego, 74 pp.] and the slope stability experiments of Martin and Aral [Martin, C.S. and M.M. Aral, 1971. Seepage force on interfacial bed particles. J. Hydraulics Div., proc. ASCE, Vol. 97, No. Hy7, pp. 1081-1100]. (C) 2001 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. We compared the anesthetic efficacy of inferior alveolar nerve block (IANB) plus buccal infiltration (BI) and IANB plus periodontal ligament (PDL) articaine injections in patients with irreversible pulpitis in the mandibular first molar. Study design. Fifty-seven volunteers, patients with irreversible pulpitis in the mandibular first molar admitted to the Department of Stomatology, Second Affiliated Hospital, Sun Yat-Sen University, randomly received conventional IANB, containing 1.7 mL 4% articaine/HCl with 1:100,000 epinephrine, plus either BI or PDL injections containing 0.4 mL articaine/HCl with 1: 100,000 epinephrine. The patients recorded the pain of the injections and endodontic access on a Heft-Parker visual analog scale (VAS). Results. According to the VAS scores, all patients experienced no or mild pain with BI and PDL injections after the application of IANB. Anesthetic success occurred in 81.48% for IANB plus BI (IANB/BI) compared with 83.33% for IANB plus PDL injection (IANB/PDL injection). None of the observed differences between the 2 groups was significant (P > .05). Conclusion. Both injection combinations resulted in high anesthetic success in patients with irreversible pulpitis in the mandibular first molar. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009;108:e89-e93)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated if tumor-associated tissue eosinophilia (TATE) could be associated with the process of tissue invasion in oral squamous cell carcinomas (OSCCs) and its influence on patient`s prognosis. Forty-three patients treated for OSCCs with or without lymph nodes involvement, at A. C. Camargo Cancer Hospital, Brazil, were selected for TATE analysis. Two degrees of tissue eosinophilia were established in OSCC: absent/mild and intense. The TATE was evaluated in relation to the clinicopathological features and prognostic value using chi(2) test and the Kaplan-Meier method. Most of the patients with OSCC in advanced clinical stage presented Muscular infiltration and significantly intense TATE whereas those with tumors in early stage frequently showed absent/mild eosinophilia (P = .009). The TATE showed no prognostic value for 5-year and 10-year survival rates of the OSCC. These findings suggest that intense TATE seems to reflect the stromal invasion of the OSCCs that occur in advanced clinical stage.