989 resultados para high-performance liquid chromatography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In-silico optimised two-dimensional high performance liquid chromatographic (2D-HPLC) separations of a model methamphetamine seizure sample are described, where an excellent match between simulated and real separations was observed. Targeted separation of model compounds was completed with significantly reduced method development time. This separation was completed in the heart-cutting mode of 2D-HPLC where C18 columns were used in both dimensions taking advantage of the selectivity difference of methanol and acetonitrile as the mobile phases. This method development protocol is most significant when optimising the separation of chemically similar chemical compounds as it eliminates potentially hours of trial and error injections to identify the optimised experimental conditions. After only four screening injections the gradient profile for both 2D-HPLC dimensions could be optimised via simulations, ensuring the baseline resolution of diastereomers (ephedrine and pseudoephedrine) in 9.7 min. Depending on which diastereomer is present the potential synthetic pathway can be categorized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The selection of two high performance liquid chromatography (HPLC) columns with vastly different retention mechanisms is vital for performing effective two-dimensional (2D-) HPLC. This paper reports on a systematic method to select a pair of HPLC columns that provide the most different separations for a given sample. This was completed with the aid of a HPLC simulator that predicted retention profiles on the basis of real experimental data, which is difficult when the contents of sample matrices are largely-or completely-unknown. Peaks from the same compounds must first be matched between chromatograms to compare the retention profiles and optimised 2D-HPLC column selection. In this work, two methods of matching peaks between chromatograms were explored and an optimal pair of chromatography columns was selected for 2D-HPLC. First, a series of 17 antioxidants were selected as an analogue for a coffee extract. The predicted orthogonality of the standards was 39%, according to the fractional surface coverage 'bins' method, which was close to the actual space utilisation of the standard mixture, 44%. Moreover, the orthogonality for the 2D-HPLC of coffee matched the predicted value of 38%. The second method employed a complex sample matrix of urine to optimise the column selections. Seven peaks were confidently matched between chromatograms by comparing relative peak areas of two detection strategies: UV absorbance and potassium permanganate chemiluminescence. It was found that the optimal combinations had an orthogonality of 35% while the actual value was closer to 30%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper explores the analytical figures of merit of two-dimensional high-performance liquid chromatography for the separation of antioxidant standards. The cumulative two-dimensional high-performance liquid chromatography peak area was calculated for 11 antioxidants by two different methods--the areas reported by the control software and by fitting the data with a Gaussian model; these methods were evaluated for precision and sensitivity. Both methods demonstrated excellent precision in regards to retention time in the second dimension (%RSD below 1.16%) and cumulative second dimension peak area (%RSD below 3.73% from the instrument software and 5.87% for the Gaussian method). Combining areas reported by the high-performance liquid chromatographic control software displayed superior limits of detection, in the order of 1 × 10(-6) M, almost an order of magnitude lower than the Gaussian method for some analytes. The introduction of the countergradient eliminated the strong solvent mismatch between dimensions, leading to a much improved peak shape and better detection limits for quantification.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This manuscript describes the development and validation of an ultra-fast, efficient, and high throughput analytical method based on ultra-high performance liquid chromatography (UHPLC) equipped with a photodiode array (PDA) detection system, for the simultaneous analysis of fifteen bioactive metabolites: gallic acid, protocatechuic acid, (−)-catechin, gentisic acid, (−)-epicatechin, syringic acid, p-coumaric acid, ferulic acid, m-coumaric acid, rutin, trans-resveratrol, myricetin, quercetin, cinnamic acid and kaempferol, in wines. A 50-mm column packed with 1.7-μm particles operating at elevated pressure (UHPLC strategy) was selected to attain ultra-fast analysis and highly efficient separations. In order to reduce the complexity of wine extract and improve the recovery efficiency, a reverse-phase solid-phase extraction (SPE) procedure using as sorbent a new macroporous copolymer made from a balanced ratio of two monomers, the lipophilic divinylbenzene and the hydrophilic N-vinylpyrrolidone (Oasis™ HLB), was performed prior to UHPLC–PDA analysis. The calibration curves of bioactive metabolites showed good linearity within the established range. Limits of detection (LOD) and quantification (LOQ) ranged from 0.006 μg mL−1 to 0.58 μg mL−1, and from 0.019 μg mL−1 to 1.94 μg mL−1, for gallic and gentisic acids, respectively. The average recoveries ± SD for the three levels of concentration tested (n = 9) in red and white wines were, respectively, 89 ± 3% and 90 ± 2%. The repeatability expressed as relative standard deviation (RSD) was below 10% for all the metabolites assayed. The validated method was then applied to red and white wines from different geographical origins (Azores, Canary and Madeira Islands). The most abundant component in the analysed red wines was (−)-epicatechin followed by (−)-catechin and rutin, whereas in white wines syringic and p-coumaric acids were found the major phenolic metabolites. The method was completely validated, providing a sensitive analysis for bioactive phenolic metabolites detection and showing satisfactory data for all the parameters tested. Moreover, was revealed as an ultra-fast approach allowing the separation of the fifteen bioactive metabolites investigated with high resolution power within 5 min.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A sensitive, precise, and specific high-performance liquid chromatographic (HPLC) method was developed for the assay of gatifloxacin (GATX) in raw material and tablets. The method validation parameters yielded good results and included the range, linearity, precision, accuracy, specificity, and recovery. It was also found that the excipients in the commercial tablet preparation did not interfere with the assay. The HPLC separation was carried out by reversed-phase chromatography on a C18 absorbosphere column (250 x 4.6 mm id, 5 pm particle size) with a mobile phase composed of acetic acid 50/o--acetonitrile-methanol (70 + 15 + 15, v/v/v) pumped isocratically at a flow rate of 1.0 mL/min. The effluent was monitored at 287 nm. The calibration graph for GATX was linear from 4.0 to 14.0 mu g/mL. The interday and intraday precisions (relative standard deviation) were less than 1.05%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two high-performance liquid chromatographic methods for determination of residual monomer in dental acrylic resins are described. Monomers were detected by their UV absorbance at 230 nm, on a Nucleosil((R)) C-18 (5 mu m particle size, 100 angstrom pore size, 15 x 0.46 cm i.d.) column. The separation was performed using acetonitrile-water (55:45 v/v) containing 0.01% triethylamine (TEA) for methyl methacrylate and butyl methacrylate, and acetonitrile-water (60:40 v/v) containing 0.01% TEA for isobutyl methacrylate and 1,6-hexanediol dimethacrylate as mobile phases, at a flow rate of 0.8 mL/min. Good linear relationships were obtained in the concentration range 5.0-80.0 mu g/mL for methyl methacrylate, 10.0-160.0 mu g/mL for butyl methacrylate, 50.0-500.0 mu g/mL for isobutyl methacrylate and 2.5-180.0 mu g/mL for 1,6-hexanediol dimethacrylate. Adequate assay for intra- and inter-day precision and accuracy was observed during the validation process. An extraction procedure to remove residual monomer from the acrylic resins was also established. Residual monomer was obtained from broken specimens of acrylic disks using methanol as extraction solvent for 2 h in an ice-bath. The developed methods and the extraction procedure were applied to dental acrylic resins, tested with or without post-polymerization treatments, and proved to be accurate and precise for the determination of residual monomer content of the materials evaluated. Copyright (c) 2005 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The high performance liquid chromatography (HPLC) technique was applied to measure phenylalanine ammonia-lyase (PAL, EC 4.3.1.5) activity in soybean (Glycine max L. Merril cv. BR16) roots. t-Cinnamate, the catalytic product of the PAL reaction was quantified at 275 nm by isocratic elution with methanol:water through an ODS(M) column. Comparative experiments were carried out with 1.0 mM ferulic acid, an inducer of PAL activity. The results suggest that liquid chromatography is a rapid and sensitive method to analyze PAL activity in non-purified extract.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two simple methods were developed to determine, 11 pesticides in coconut water, a natural isotonic drink rich in salts, sugars and vitamins consumed by the people and athletes. The first procedure involves solid-phase extraction using Sep-Pak Vac C-18 disposable cartridges with methanol for elution. Isocratic analysis was carried out by means of high-performance liquid chromatography with ultraviolet detection at 254 nm to analyse captan, chlorothalonil, carbendazim, lufenuron and diafenthiuron. The other procedure is based on liquid-liquid extraction with hexane-dichloromethane (1:1, v/v), followed by gas chromatographic analysis with effluent splitting to electron-capture detection for determination of endosulfan, captan, tetradifon and trichlorfon and thermionic specific detection for determination of malathion, parathion-methyl and monocrotophos. The methods were validated with fortified samples at different concentration levels (0.01-12.0 mg/kg). Average recoveries ranged from 75 to 104% with relative standard deviations between 1.4 and 11.5%. Each recovery analysis was repeated at least five times. Limits of detection ranged from 0.002 to 2.0 mg/kg. The analytical procedures were applied to 15 samples and no detectable amounts of the pesticides were found in any samples under the conditions described. (C) 2002 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rapid, sensitive and reliable reverse-phase HPLC method was used for the quantitative determination of the anti-fungal and insecticide amides, dihydropiplartine (1), piplartine (2), Delta(alpha,beta)-dihydropiperine (3) and pellitorine (4) in plants in natura, in plantlets in vitro and ex vitro, and in callus of Piper tuberculatum. Well-resolved peaks were obtained with good detection response and linearity in the range of 15.0-3000 mug/mL. The plants in natura contained compounds 1-4, the plantlets ex vitro and in vitro accumulated compounds 1-2 and 1-4, respectively, while only amide 4 was found in callus. Copyright (C) 2003 John Wiley Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Explants of Maytenus aquifolium were induced to form callus and, subsequently, suspension cultures. The isolation of natural products from callus led to the identification of the cytotoxic triterpene quinonemethides, maitenin (1) and 22 beta-hydroxymaitenin (2), A rapid, sensitive and reliable reversed-phase high-performance liquid chromatography method was developed using a Cls column and isocratic elution for the determination of 1 and 2, the elaborated method gave well-resolved peaks for these compounds with good detection response and linearity in the range of 0.08-72.0 mu g. The quantification of 1 and 2 was performed by an external standard method. (C) 1998 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of studies was conducted to establish a methodology for the accurate and efficient determination of betaine in different feed ingredients. The final methodology involves an extraction step in which the feed sample is heated for 3h in a methanolic KOH solution using a Goldfisch apparatus. Impurities are removed by the addition of activated charcoal and concentrated (36%) HCl. After centrifugation the extractant is passed through a strong cation exchange resin (Dowex 50W-X12, H+). The betaine retained in the column is eluted with 1.5 N HCl. A 2 nil aliquot of the elute is air dried and reconstituted with 1 ml of deionised water. HPLC separation with a cation exchange column (Partisil SCX-10) is used for the separation of betaine from other compounds. The mobile phase is kept constant at 50mm KH2PO4 in water, and eluted compounds are detected by UV absorbance (200nm). The flow rate is maintained at 1.5ml min(-1). This assay is very accurate over the range of betaine concentrations from 15 to 650 mug ml(-1), with a lower detection limit in feeds of approximately 500 mug g(-1) when 4g of sample is extracted. Recovery assays done with standard betaine hydrochloride and hard red wheat resulted in a consistent recovery of 80%. Betaine content was quantified in several feed ingredients, including alfalfa (1.77 mg kg(-1)), wheat (3.96 mg kg(-1)), wheat middlings (4.98 mg kg(-1)) and poultry meal (0.77 mg kg(-1)). Betaine in corn and soybean meal was not detectable by this method, even when 16g of sample was used (<125 mg kg(-1)). Betaine present in several feed ingredients should influence choline supplementation to animal feeds and may have implications for human health. (C) 2002 Society of Chemical Industry.