776 resultados para high strength concrete


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The loss of prestressing force over time influences the long-term deflection of the prestressed concrete element. Prestress losses are inherently complex due to the interaction of concrete creep, concrete shrinkage, and steel relaxation. Implementing advanced materials such as ultra-high performance concrete (UHPC) further complicates the estimation of prestress losses because of the changes in material models dependent on curing regime. Past research shows compressive creep is "locked in" when UHPC cylinders are subjected to thermal treatment before being loaded in compression. However, the current precasting manufacturing process would typically load the element (through prestressing strand release from the prestressing bed) before the element would be taken to the curing facility. Members of many ages are stored until curing could be applied to all of them at once. This research was conducted to determine the impact of variable curing times for UHPC on the prestress losses, and hence deflections. Three UHPC beams, a rectangular section, a modified bulb tee section, and a pi-girder, were assessed for losses and deflections using an incremental time step approach and material models specific to UHPC based on compressive creep and shrinkage testing. Results show that although it is important for prestressed UHPC beams to be thermally treated, to "lock in" material properties, the timing of thermal treatment leads to negligible differences in long-term deflections. Results also show that for UHPC elements that are thermally treated, changes in deflection are caused only by external loads because prestress losses are "locked-in" following thermal treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concrete substructures are often subjected to environmental deterioration, such as sulfate and acid attack, which leads to severe damage and causes structure degradation or even failure. In order to improve the durability of concrete, the High Performance Concrete (HPC) has become widely used by partially replacing cement with pozzolanic materials. However, HPC degradation mechanisms in sulfate and acidic environments are not completely understood. It is therefore important to evaluate the performance of the HPC in such conditions and predict concrete service life by establishing degradation models. This study began with a review of available environmental data in the State of Florida. A total of seven bridges have been inspected. Concrete cores were taken from these bridge piles and were subjected for microstructural analysis using Scanning Electron Microscope (SEM). Ettringite is found to be the products of sulfate attack in sulfate and acidic condition. In order to quantitatively analyze concrete deterioration level, an image processing program is designed using Matlab to obtain quantitative data. Crack percentage (Acrack/Asurface) is used to evaluate concrete deterioration. Thereafter, correlation analysis was performed to find the correlation between five related variables and concrete deterioration. Environmental sulfate concentration and bridge age were found to be positively correlated, while environmental pH level was found to be negatively correlated. Besides environmental conditions, concrete property factor was also included in the equation. It was derived from laboratory testing data. Experimental tests were carried out implementing accelerated expansion test under controlled environment. Specimens of eight different mix designs were prepared. The effect of pozzolanic replacement rate was taken into consideration in the empirical equation. And the empirical equation was validated with existing bridges. Results show that the proposed equations compared well with field test results with a maximum deviation of ± 20%. Two examples showing how to use the proposed equations are provided to guide the practical implementation. In conclusion, the proposed approach of relating microcracks to deterioration is a better method than existing diffusion and sorption models since sulfate attack cause cracking in concrete. Imaging technique provided in this study can also be used to quantitatively analyze concrete samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a shortage of experimentally determined strains during sheet metal shearing. These kinds of data are a requisite to validate shearing models and to simulate the shearing process. In this work, strain fields were continuously measured during shearing of a medium and a high strength steel sheet, using digital image correlation. Preliminary studies based on finite element simulations, suggested that the effective surface strains are a good approximation of the bulk strains below the surface. The experiments were performed in a symmetric set-up with large stiffness and stable tool clearances, using various combinations of tool clearance and clamping configuration. Due to large deformations, strains were measured from images captured in a series of steps from shearing start to final fracture. Both the Cauchy and Hencky strain measures were considered, but the difference between these were found negligible with the number of increments used (about 20 to 50). Force-displacement curves were also determined for the various experimental conditions. The measured strain fields displayed a thin band of large strain between the tool edges. Shearing with two clamps resulted in a symmetric strain band whereas there was an extended area with large strains around the tool at the unclamped side when shearing with one clamp. Furthermore, one or two cracks were visible on most of the samples close to the tool edges well before final fracture. The fracture strain was larger for the medium strength material compared with the high-strength material and increased with increasing clearance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An innovative cement-based soft-hard-soft (SHS) multi-layer composite has been developed for protective infrastructures. Such composite consists of three layers including asphalt concrete (AC), high strength concrete (HSC), and engineered cementitious composites (ECC). A three dimensional benchmark numerical model for this SHS composite as pavement under blast load was established using LSDYNA and validated by field blast test. Parametric studies were carried out to investigate the influence of a few key parameters including thickness and strength of HSC and ECC layers, interface properties, soil conditions on the blast resistance of the composite. The outcomes of this study also enabled the establishment of a damage pattern chart for protective pavement design and rapid repair after blast load. Efficient methods to further improve the blast resistance of the SHS multi-layer pavement system were also recommended.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a combined experimental and numerical study on the damage and performance of a soft-hard-soft (SHS) multi-layer cement based composite subjected to blast loading which can be used for protective structures and infrastructures to resist extreme loadings, and the composite consists of three layers of construction materials including asphalt concrete (AC) on the top, high strength concrete (HSC) in the middle, and engineered cementitious composites (ECC) at the bottom. To better characterize the material properties under dynamic loading, interface properties of the composite were investigated through direct shear test and also used to validate the interface model. Strain rate effects of the asphalt concrete were also studied and both compressive and tensile dynamic increase factor (DIF) curves were improved based on split Hopkinson pressure bar (SHPB) test. A full-scale field blast test investigated the blast behavior of the composite materials. The numerical model was established by taking into account the strain rate effect of all concrete materials. Furthermore, the interface properties were also considered into the model. The numerical simulation using nonlinear finite element software LS-DYNA agrees closely with the experimental data. Both the numerical and field blast test indicated that the SHS composite exhibited high resistance against blast loading.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An attempt has been made experimentally to investigate the acoustic emission (AE) energy release in high-strength concrete (HSC) beams subjected to monotonically increasing load. Acoustic emission energy release during the fracture process of the HSC beams is measured. Stress waves released during the fracture process in materials cause acoustic emissions. AE energy released during the fracture of a notched three-point bend plain concrete beam specimens having 28-day compressive strengths of 50.0 MPa, 69.0 MPa and 78.0 MPa and mortar (cement: sand (1: 4) by weight) specimens are studied. Mortar consists of one part cement and four parts sand by weight. The specimens were tested by a material testing system of 1200 kN capacity employing crack mouth opening displacement control at the rate of 0.0004 mm/s. The fracture energy and the AE energy released during the fracture process of all the tested TPB and mortar specimens are compared and discussed. The observations made in the present experimental study have some applications for monitoring the integrity of structures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses the beneficial influence of compressive membrane action in fibre reinforced polymer (FRP)reinforced in-plane restrained slabs in bridge deck slabs and the improved service performance when archingaction occurs. Bridge deck slabs that are exposed to extreme environmental conditions can experience severecorrosion damage. Expansive corrosion in steel reinforcement significantly reduces the design life and durabilityof concrete structures; for example, on one short section of the M1 in Northern Ireland, nearly £1 million was spent last year on the maintenance and repair of bridges due to corrosion. Corrosion-resistant compositereinforcement such as basalt fibre reinforced polymer (BFRP) and glass fibre reinforced polymer (GFRP) provides adurable alternative to reinforcing steel. In this research, two BFRP reinforced slabs and two GFRP reinforced slabswere constructed using high-strength concrete with a target cube compressive strength of 65 N/mm2. The slabsrepresented typical full-scale dimensions of a real bridge deck slab 475 mm wide by 1425 mm long and 150 mmdeep. The service and ultimate behaviour of the slabs are discussed and the results are compared with the relevantdesign guidelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The reinforced concrete structures are largely used in buildings worldwide. Upon the occurrence of fire in buildings, there is a consensus among researchers that the concrete has a high resistance to fire, due mainly to its low thermal conductivity. However, this does not mean that this material is not affected by exposure to high temperatures. Reduction of the compressive strength, modulus of elasticity, discoloration and cracking, are some of the effects caused by thermal exposure. In the case of concretes with higher resistance occurs even desplacamentos explosives, exposing the reinforcement to fire and contributing to reducing the support capacity of the structural element. Considering the above, this study aims to examine how the compressive strength and porosity of concrete are affected when subjected to high temperatures. Were evaluated concrete of different resistances, and even was the verified if addition fibers of polyethylene terephthalate (PET) in concrete can be used as an alternative to preventing spalling. The results indicated that explosive spalling affect not only high strength concrete whose values of this study ranged from 70 to 88 MPa, as well as conventional concrete of medium strength (52 MPa) and the temperature range to which the concrete begins to suffer significant changes in their resistance is between 400 º C and 600 º C, showing to 600 º C a porosity up to 188% greater than the room temperature

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The need to build durable structures and resistant to harsh environments enabled the development of high strength concrete, these activities generate a high cement consumption, which implies factor in CO2 emissions. Often the desired strength is not achieved using only the cement composition. This study aims to evaluate the influence of pozzolans with the addition of metakaolin on the physical mechanics of high strength concrete comparing them with the standard formulation. Assays were performed to characterize the aggregates according to NBR 7211, evaluation of cement and coarse aggregate through the trials of petrography (NBR 15577-3/08) and alkali-aggregate reaction (NBR 15577-05/08). Specimens were fabricated according to NBR 5738-1/04 with additions of 0%, 4%, 6%, 8% and 10% of metakaolin for cement mortars CP V in the formulations. For evaluation of the concrete hardened in fresh state and scattering assays were performed and compressive strength in accordance with the NBR 7223/1992 and NBR 5739-8/94 respectively. The results of the characterization of aggregates showed good characteristics regarding size analysis and petrography, as well as potentially innocuous as the alkali-aggregate reaction. As to the test of resistance to compression, all the formulations with the addition of metakaolin showed higher value at 28 days of disruption compared with the standard formulation. These results present an alternative to reduce CO2 emissions, and improvements in the quality and durability of concrete, because the fine particle size of metakaolin provides an optimal compression of the mass directly influencing the strength and rheology of the dough

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Foram analisadas experimentalmente 10 (dez) lajes lisas de concreto dosado com metacaulim e concreto de alta resistência (fcc =60 MPa). submetidas a carregamento simétrico. objetivando analisar a influência da variação do índice de retangularidade dos pilares (CIII;{. mm = 1. 3 e 5) e de armaduras de cisa1harnento na resistência ao puncionamento das mesmas. As armaduras de cisalhamento foram constituídas por estribos abertos inclinados. As lajes tinham dimensões de (1.800 x 1.800 x 110) mm e as principais variáveis foram à variação do índice de retangularidade dos pilares e distribuição dos estribos inclinados em tomo dos mesmos. Analisou-se os resultados de cargas de ruptura. flechas. mapa de fissuração. ductilidade. deformações no concreto e nas armaduras de ftexão e cisalhamento, e os modos de ruptura atingidos. Os resultados experimentais foram comparados com os resultados estimados por diversas normas. São também apresentados os resultados obridos numericamente para as lajes ensaiadas e comparados com os resultados experimentais. Os resultados experimentais mostraram que o aumento do índice de retangularidade faz com que as forças cortantes se concentrem nas extremidades do pilar, o que sugere que nessa região as armaduras de combate ao pmtcionamento são mais solicitadas. Os estribos inclinados foram eficientes no aumento das cargas de ruptura e alteraram inclusive o modo de ruptura de algumas lajes. Observou-se ganhos de até 32% quando os estribos foram distribuídos em tomo das extremidades dos pilares. A baixa capacidade resistente à flexão limitou a resistência última.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reinforced concrete columns might fail because of buckling of the longitudinal reinforcing bar when exposed to earthquake motions. Depending on the hoop stiffness and the length-over-diameter ratio, the instability can be local (in between two subsequent hoops) or global (the buckling length comprises several hoop spacings). To get insight into the topic, an extensive literary research of 19 existing models has been carried out including different approaches and assumptions which yield different results. Finite element fiberanalysis was carried out to study the local buckling behavior with varying length-over-diameter and initial imperfection-over-diameter ratios. The comparison of the analytical results with some experimental results shows good agreement before the post buckling behavior undergoes large deformation. Furthermore, different global buckling analysis cases were run considering the influence of different parameters; for certain hoop stiffnesses and length-over-diameter ratios local buckling was encountered. A parametric study yields an adimensional critical stress in function of a stiffness ratio characterized by the reinforcement configuration. Colonne in cemento armato possono collassare per via dell’instabilità dell’armatura longitudinale se sottoposte all’azione di un sisma. In funzione della rigidezza dei ferri trasversali e del rapporto lunghezza d’inflessione-diametro, l’instabilità può essere locale (fra due staffe adiacenti) o globale (la lunghezza d’instabilità comprende alcune staffe). Per introdurre alla materia, è proposta un’esauriente ricerca bibliografica di 19 modelli esistenti che include approcci e ipotesi differenti che portano a risultati distinti. Tramite un’analisi a fibre e elementi finiti si è studiata l’instabilità locale con vari rapporti lunghezza d’inflessione-diametro e imperfezione iniziale-diametro. Il confronto dei risultati analitici con quelli sperimentali mostra una buona coincidenza fino al raggiungimento di grandi spostamenti. Inoltre, il caso d’instabilità globale è stato simulato valutando l’influenza di vari parametri; per certe configurazioni di rigidezza delle staffe e lunghezza d’inflessione-diametro si hanno ottenuto casi di instabilità locale. Uno studio parametrico ha permesso di ottenere un carico critico adimensionale in funzione del rapporto di rigidezza dato dalle caratteristiche dell’armatura.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

En la presente investigación se buscó estudiar el efecto de la adición de fibras metálicas como refuerzo en hormigones de alta resistencia, y en especial su comportamiento frente al impacto de proyectiles. Se efectuó el estudio sobre un hormigón de alta resistencia (HAR), analizando los aspectos mecánicos, durabilidad y trabajabilidad para su colocación en obra. Las pruebas de laboratorio se llevaron a cabo en el Laboratorio de Materiales de Construcción de la Escuela Técnica Superior de Caminos Canales y Puertos de la UPM y los ensayos balísticos en la galería de tiro cubierta del Polígono de Experiencia de Carabanchel, adscrito a la Dirección General de Infraestructura del Ministerio de la Defensa. La caracterización del HAR empleado en el estudio se centró en los aspectos de resistencias mecánicas a compresión, tracción, flexotracción, tenacidad a flexotracción, punzonamiento, retracción, fluencia, temperatura interna y resistencia al impacto de proyectiles, siempre buscando de manera primordial analizar el efecto de la adición de fibras en el hormigón de alta resistencia. El programa de ensayos balísticos comprendió la fabricación de 47 placas de hormigón de diferentes espesores, desde 5 a 40 cm., 26 de dichas placas eran de HAR con una adición de fibras metálicas de 80 kg/m3, 11 de ellas eran de HAR sin fibras y 10 de un hormigón de resistencia convencional con y sin fibras; sobre dichas placas se efectuaron diversos impactos con proyectiles de los cuatro calibres siguientes: 7.62 AP, 12.70 M8, 20 mm APDS y 25 mm APDS. Las pruebas mostraron que el HAR presenta una mayor resistencia a los impactos de proyectiles, aunque sin la adición de fibras su fragilidad es un serio inconveniente para su utilización como barrera protectora, la adición de fibras reduce considerablemente la fragmentación en la cara posterior “scabbing” y en menor medida en la cara anterior “spalling”. También se incrementa la capacidad del hormigón a la resistencia de múltiples impactos. Se efectuó un estudio de las diferentes formulas y modelos, en especial el modelo desarrollado por Moreno [60], que se vienen utilizando para el diseño de barreras protectoras de hormigón contra impacto de proyectiles, analizando su viabilidad en el caso del hormigón de alta resistencia, hormigón para el cual no fueron desarrolladas y para el que no existen bases de cálculo específicas. In this research we have tried to study the effect of adding metallic fibres as a means of reinforcing high strength concrete, and especially its behaviour when impacted upon by projectiles. The study was carried out using high strength concrete (HSC), analysing its mechanical facets, durability and malleability when used in construction. The laboratory tests took place in the Laboratorio de Materiales de Construcción of the Escuela Técnica Superior de Caminos Canales y Puertos of the Universidad Politécnica de Madrid, and the ballistic tests were carried out in the covered shooting gallery of the Polígono de Experiencias in Carabanchel (Madrid), belongs to the Departamento de Infraestructura of the Ministerio de Defensa. The aspects of the HSC studied are its mechanical strength to compression, traction, flexotraction, resilience to flexo-traction, shear strength, creep, shrinkage, internal temperature and strength to the impact of projectiles, always looking to analyse the effect of adding fibres to HSC. The ballistic testing process required the construction of 47 concrete plates of different thicknesses, from 5 to 40 cm, 26 made which HSC containing of 80 kg/m3 metallic fibres of, 11 made of HSC without fibres, and 10 made with concrete of normal strength with and without fibres. These plates were subjected to a variety of impacts by four projectile, 7.62 AP, 12.70 M8, 20 mm APDS and 25 mm APDS. The results showed that HSC has a greater resistance to the impact of projectiles, although without the addition of fibres, its fragility makes it much less suitable for use as a protective barrier. The addition of fibres reduces considerably frontal fragmentation, known as “scabbing”, and to a lesser extent causes fragmentation of the reverse side, known as “spalling”. In addition, the concrete’s capacity to resist multiple impacts is improved by its letter ductility. A study was carried out on the various formulae and models used to design protective concrete barriers impacted on by projectiles, analysing their viability in the case of HSC for which they were not developed and for which no specific calculations exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El presente Trabajo Fin de Máster consistió en determinar la influencia que pueden poseer las nano-adiciones de Sílice y Alúmina y fibras de acero en un Hormigón de Alta Resistencia. Partiendo de una dosificación de Hormigón de Alta Resistencia conocida, que contenía humo de Sílice (10%) y fibras de poliolefina (3kg/m3), se les procedió a sustituir por la incorporación de nano-adiciones de Sílice y Alúmina (7% y 3% respectivamente) y añadiendo fibras de acero en lugar de poliolefina. En el presente trabajo se realizó una campaña experimental de laboratorio, en donde se realizaron tres (3) amasadas de Hormigón de Alta Resistencia con nueve (9) probetas cada una, donde el contenido de nano-adiciones no varió, mientras que el contenido de fibras fue de 20 y 40 kg/m3. Posterior a su realización, se procedió a someter las probetas a ensayos de resistencia a compresión, resistencia a tracción indirecta, resistencia a flexotracción, permeabilidad, módulo de elasticidad y coeficiente de Poisson con el fin de conocer el comportamiento de las amasadas una vez añadidas las nano-adiciones y fibras de acero. Luego de ejecutados los ensayos, se procedió a comparar los resultados entre amasadas y con las del hormigón de referencia. Los resultados muestran que la incorporación de las fibras de acero mejoran las propiedades del Hormigón de Alta Resistencia, sin negatividad. This Master’s Degree Thesis was to determine the influence that steel fibers and nano-additions of Silica and Alumina may possess in a High Strength Concrete mix. Based on a known dosage of High Strength Concrete, which contained Silica fume (10%) and polyolefin fibers (3 kg/m3), they were proceeded to be substituted for the incorporation of nano-additions of Silica and Alumina (7% and 3%, respectively) and by adding steel fibers rather than polyolefin fibers. This thesis carried out an experimental laboratory campaign, in which three (3) mixes of High Strength Concrete had nine (9) specimens each, where the content of nano-additions did not change, while the steel fiber content was 20 and 40 kg/m3. Subsequent to its completion, the specimens were subjected to different tests to determine the compressive strength, tensile strength, flexural strength, permeability, modulus of elasticity and Poisson's ratio in order to know the behavior of the mixes once the nano-additions and steel fibers were added. The results indicate that the steel fibers improve the properties of the High Strength Concrete rather to affect in a negative way