976 resultados para ecliptic curve based chameleon hashing


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In developing a biosensor, the utmost important aspects that need to be emphasized are the specificity and selectivity of the transducer. These two vital prerequisites are of paramount in ensuring a robust and reliable biosensor. Improvements in electrochemical sensors can be achieved by using microelectrodes and to modify the electrode surface (using chemical or biological recognition layers to improve the sensitivity and selectivity). The fabrication and characterisations of silicon-based and glass-based gold microelectrode arrays with various geometries (band and disc) and dimension (ranging from 10 μm-100 nm) were reported. It was found that silicon-based transducers of 10 μm gold microelectrode array exhibited the most stable and reproducible electrochemical measurements hence this dimension was selected for further study. Chemical electrodeposition on both 10 μm microband and microdisc were found viable by electro-assisted self-assembled sol-gel silica film and nanoporous-gold electrodeposition respectively. The fabrication and characterisations of on-chip electrochemical cell was also reported with a fixed diameter/width dimension and interspacing variation. With this regard, the 10 μm microelectrode array with interspacing distance of 100 μm exhibited the best electrochemical response. Surface functionalisations on single chip of planar gold macroelectrodes were also studied for the immobilisation of histidine-tagged protein and antibody. Imaging techniques such as atomic force microscopy, fluorescent microscopy or scanning electron microscope were employed to complement the electrochemical characterisations. The long-chain thiol of self-assembled monolayer with NTA-metal ligand coordination was selected for the histidine-tagged protein while silanisation technique was selected for the antibody immobilisation. The final part of the thesis described the development of a T-2 labelless immunosensor using impedimetric approach. Good antibody calibration curve was obtained for both 10 μm microband and 10 μm microdisc array. For the establishment of the T-2/HT-2 toxin calibration curve, it was found that larger microdisc array dimension was required to produce better calibration curve. The calibration curves established in buffer solution show that the microelectrode arrays were sensitive and able to detect levels of T-2/HT-2 toxin as low as 25 ppb (25 μg kg-1) with a limit of quantitation of 4.89 ppb for a 10 μm microband array and 1.53 ppb for the 40 μm microdisc array.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To examine the associations between attention-deficit/hyperactivity disorder (ADHD) symptoms, obesity and hypertension in young adults in a large population-based cohort. DESIGN, SETTING AND PARTICIPANTS: The study population consisted of 15,197 respondents from the National Longitudinal Study of Adolescent Health, a nationally representative sample of adolescents followed from 1995 to 2009 in the United States. Multinomial logistic and logistic models examined the odds of overweight, obesity and hypertension in adulthood in relation to retrospectively reported ADHD symptoms. Latent curve modeling was used to assess the association between symptoms and naturally occurring changes in body mass index (BMI) from adolescence to adulthood. RESULTS: Linear association was identified between the number of inattentive (IN) and hyperactive/impulsive (HI) symptoms and waist circumference, BMI, diastolic blood pressure and systolic blood pressure (all P-values for trend <0.05). Controlling for demographic variables, physical activity, alcohol use, smoking and depressive symptoms, those with three or more HI or IN symptoms had the highest odds of obesity (HI 3+, odds ratio (OR)=1.50, 95% confidence interval (CI) = 1.22-2.83; IN 3+, OR = 1.21, 95% CI = 1.02-1.44) compared with those with no HI or IN symptoms. HI symptoms at the 3+ level were significantly associated with a higher OR of hypertension (HI 3+, OR = 1.24, 95% CI = 1.01-1.51; HI continuous, OR = 1.04, 95% CI = 1.00-1.09), but associations were nonsignificant when models were adjusted for BMI. Latent growth modeling results indicated that compared with those reporting no HI or IN symptoms, those reporting 3 or more symptoms had higher initial levels of BMI during adolescence. Only HI symptoms were associated with change in BMI. CONCLUSION: Self-reported ADHD symptoms were associated with adult BMI and change in BMI from adolescence to adulthood, providing further evidence of a link between ADHD symptoms and obesity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The stencil printing process is an important process in the assembly of Surface Mount Technology (SMT)devices. There is a wide agreement in the industry that the paste printing process accounts for the majority of assembly defects. Experience with this process has shown that typically over 60% of all soldering defects are due to problems associated with the flow properties of solder pastes. Therefore, the rheological measurements can be used as a tool to study the deformation or flow experienced by the pastes during the stencil printing process. This paper presents results on the thixotropic behaviour of three pastes; lead-based solder paste, lead-free solder paste and isotropic conductive adhesive (ICA). These materials are widely used as interconnect medium in the electronics industry. Solder paste are metal alloys suspended in a flux medium while the ICAs consist of silver flakes dispersed in an epoxy resin. The thixotropy behaviour was investigated through two rheological test; (i) hysteresis loop test and (ii) steady shear rate test. In the hysteresis loop test, the shear rate were increased from 0.001 to 100s-1 and then decreased from 100 to 0.001s-1. Meanwhile, in the steady shear rate test, the materials were subjected to a constant shear rate of 0.100, 100 and 0.001s-1 for a period of 240 seconds. All the pastes showed a high degree of shear thinning behaviour with time. This might be due to the agglomeration of particles in the flux or epoxy resin that prohibits pastes flow under low shear rate. The action of high shear rate would break the agglomerates into smaller pieces which facilitates the flow of pastes, thus viscosity is reduced at high shear rate. The solder pastes exhibited a higher degree of structural breakdown compared to the ICAs. The area between the up curve and down curve in the hysteresis curve is an indication of the thixotropic behavior of the pastes. Among the three pastes, lead-free solder paste showed the largest area between the down curve and up curve, which indicating a larger structural breakdown in the pastes, followed by lead-based solder paste and ICA. In a steady shear rate test, viscosity of ICA showed the best recovery with the steeper curve to its original viscosity after the removal of shear, which indicating that the dispersion quality in ICA is good because the high shear has little effect on the microstructure of ICA. In contrast, lead-based paste showed the poorest recovery which means this paste undergo larger structural breakdown and dispersion quality in this paste is poor because the microstructure of the paste is easily disrupted by high shear. The structural breakdown during the application of shear and the recovery after removal of shear is an important characteristic in the paste printing process. If the paste’s viscosity can drop low enough, it may contribute to the aperture filling and quick recovery may prevent slumping.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present an occultation of the newly discovered hot Jupiter system WASP-19, observed with the High Acuity Wide-field K-band Imager instrument on the VLT, in order to measure thermal emission from the planet's dayside at ~2µm. The light curve was analysed using a Markov Chain Monte Carlo method to find the eclipse depth and the central transit time. The transit depth was found to be 0.366 +/- 0.072 per cent, corresponding to a brightness temperature of 2540 +/- 180 K. This is significantly higher than the calculated (zero-albedo) equilibrium temperature and indicates that the planet shows poor redistribution of heat to the night side, consistent with models of highly irradiated planets. Further observations are needed to confirm the existence of a temperature inversion and possibly molecular emission lines. The central eclipse time was found to be consistent with a circular orbit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computing has recently reached an inflection point with the introduction of multicore processors. On-chip thread-level parallelism is doubling approximately every other year. Concurrency lends itself naturally to allowing a program to trade performance for power savings by regulating the number of active cores; however, in several domains, users are unwilling to sacrifice performance to save power. We present a prediction model for identifying energy-efficient operating points of concurrency in well-tuned multithreaded scientific applications and a runtime system that uses live program analysis to optimize applications dynamically. We describe a dynamic phase-aware performance prediction model that combines multivariate regression techniques with runtime analysis of data collected from hardware event counters to locate optimal operating points of concurrency. Using our model, we develop a prediction-driven phase-aware runtime optimization scheme that throttles concurrency so that power consumption can be reduced and performance can be set at the knee of the scalability curve of each program phase. The use of prediction reduces the overhead of searching the optimization space while achieving near-optimal performance and power savings. A thorough evaluation of our approach shows a reduction in power consumption of 10.8 percent, simultaneous with an improvement in performance of 17.9 percent, resulting in energy savings of 26.7 percent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A UV indicator/dosimeter based on benzyl viologen (BV2+) encapsulated in polyvinyl alcohol (PVA) is described. Upon exposure to UV light, the BV2+/PVA film turns a striking purple colour due to the formation of the cation radical, BV center dot+. The usual oxygen sensitivity of BV center dot+ is significantly reduced due to the very low oxygen permeability of the encapsulating polymer, PVA. Exposure of a typical BV2+/PVA film, for a set amount of time, to UVB light with different UV indices produces different levels of BV center dot+, as measured by the absorbance of the film at 550 nm. A plot of the change in absorbance at this wavelength, Delta Abs(550), as a function of UV index, UVI, produces a linear calibration curve which allows the film to be used as a UVB indicator, and a similar procedure could be employed to allow it to be used as a solar UVI indicator. A typical BV2+/PVA film generates a significant, semi-permanent (stable for > 24 h) saturated purple colour (absorbance similar to 0.8-0.9) upon exposure to sunlight equivalent to a minimal erythemal dose associated with Caucasian skin, i.e. skin type II. The current drawbacks of the film and the possible future use of the BV2+/PVA film as a personal solar UV dosimeter for all skin types are briefly discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A novel hardware architecture for elliptic curve cryptography (ECC) over GF(p) is introduced. This can perform the main prime field arithmetic functions needed in these cryptosystems including modular inversion and multiplication. This is based on a new unified modular inversion algorithm that offers considerable improvement over previous ECC techniques that use Fermat's Little Theorem for this operation. The processor described uses a full-word multiplier which requires much fewer clock cycles than previous methods, while still maintaining a competitive critical path delay. The benefits of the approach have been demonstrated by utilizing these techniques to create a field-programmable gate array (FPGA) design. This can perform a 256-bit prime field scalar point multiplication in 3.86 ms, the fastest FPGA time reported to date. The ECC architecture described can also perform four different types of modular inversion, making it suitable for use in many different ECC applications. © 2006 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A surface plasmon resonance (SPR)-based inhibition assay method using a polyclonal anti-mouse IgM arrayed Cryptosporidium sensor chip was developed for the real-time detection of Cryptosporidium parvum oocysts. The Cryptosporidium sensor chip was fabricated by subsequent immobilization of streptavidin and polyclonal anti-mouse IgM (secondary antibody) onto heterogeneous self-assembled monolayers (SAMs). The assay consisted of the immunoreaction step between monoclonal anti-C. parvum oocyst (primary antibody) and oocysts, followed by the binding step of the unbound primary antibody onto the secondary antibody surface. It enhanced not only the immunoreaction yield of the oocysts by batch reaction but also the accessibility of analytes to the chip surface by antibody–antibody interaction. Furthermore, the use of optimum concentration of the primary antibody maximized its binding response on the chip. An inversely linear calibration curve for the oocyst concentration versus SPR signal was obtained in the range of 1×106–1×102 oocysts ml-1. The oocyst detection was also successfully achieved in natural water systems. These results indicate that the SPR-based inhibition assay using the Cryptosporidium sensor chip has high application potential for the real-time analysis of C. parvum oocyst in laboratory and field water monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fiber-reinforced polymer (FRP) hollow tubes are used in structural applications, such as utility poles and pipelines. Concrete-filled FRP tubes (CFFTs) are also used as piles and bridge piers. Applications such as poles and marine piles are typically governed by cyclic bending. In this paper, the fatigue behavior of glass-FRP filament-wound tubes is studied using coupons cut from the tubes. Several coupon configurations were first examined in 24 tension and five compression monotonic loading tests. Fatigue tests were then conducted on 81 coupons to examine several parameters; namely, loading frequency as well as maximum-to-ultimate (max ult) and minimum-to-maximum (min max) stress ratios, including tension tension and tension compression, to simulate reversed bending. The study demonstrated the sensitivity of test results and failure mode to coupon configuration. The presence of compression loads reduced fatigue life, while increasing load frequency increased fatigue life. Stiffness degradation behavior was also established. To achieve at least one million cycles, it is recommended to limit (max ult) to 0.25. Models were used to simulate stiffness degradation and fatigue life curve of the tube. Fatigue life predictions of large CFFT beams showed good correlation with experimental results. © 2008 ASCE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the difficulties with using molecularly imprinted polymers (MIPs) and other electrically insulating materials as the recognition element in electrochemical sensors is the lack of a direct path for the conduction of electrons from the active sites to the electrode. We have sought to address this problem through the preparation and characterization of novel hybrid materials combining a catalytic MIP, capable of oxidizing the template, catechol, with an electrically conducting polymer. In this way a network of "molecular wires" assists in the conduction of electrons from the active sites within the MIP to the electrode surface. This was made possible by the design of a new monomer that combines orthogonal polymerizable functionality; comprising an aniline group and a methacrylamide. Conducting films were prepared on the surface of electrodes (Au on glass) by electropolymerization of the aniline moiety. A layer of MIP was photochemically grafted over the polyaniline, via N,N'-diethyldithiocarbamic acid benzyl ester (iniferter) activation of the methacrylamide groups. Detection of catechol by the hybrid-MIP sensor was found to be specific, and catechol oxidation was detected by cyclic voltammetry at the optimized operating conditions: potential range -0.6 V to +0.8 V (vs Ag/AgCl), scan rate 50 mV/s, PBS pH 7.4. The calibration curve for catechol was found to be linear to 144 µM, with a limit of detection of 228 nM. Catechol and dopamine were detected by the sensor, whereas analogues and potentially interfering compounds, including phenol, resorcinol, hydroquinone, serotonin, and ascorbic acid, had minimal effect (=3%) on the detection of either analyte. Nonimprinted hybrid electrodes and bare gold electrodes failed to give any response to catechol at concentrations below 0.5 mM. Finally, the catalytic properties of the sensor were characterized by chronoamperometry and were found to be consistent with Michaelis-Menten kinetics. © 2009 American Chemical Society.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A significant cold event, deduced from the Greenland ice cores, took place between 8200 and 8000 cal. BP. Modeling of the event suggests that higher northern latitudes would have also experienced considerable decreases in precipitation and that Ireland would have witnessed one of the greatest depressions. However, no well-dated proxy record exists from the British Isles to test the model results. Here we present independent evidence for a phase of major pine recruitment on Irish bogs at around 8150 cal. BP. Dendrochronological dating of subfossil trees from three sites reveal synchronicity in germination across the region, indicative of a regional forcing, and allows for high-precision radiocarbon based dating. The inner-rings of 40% of all samples from the north of Ireland dating to the period 8500-7500 cal. BP fall within a 25-yr window. The concurrent colonization of pine on peatland is interpreted as drier conditions in the region and provides the first substantive proxy data in support of a significant hydrological change in the north of Ireland accompanying the 8.2 ka event. The dating uncertainties associated with the Irish pine record and the Greenland Ice Core Chronology 2005 (GICC05) do not allow for any overlap between the two. Our results indicate that the discrepancy could be an artifact of dating inaccuracy, and support a similar claim by Lohne et al. (2013) for the Younger Dryas boundaries. If real, this asynchrony will most likely have affected interpretations of previous proxy alignments.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The current theory of catalyst activity in heterogeneous catalysis is mainly obtained from the study of catalysts with mono-phases, while most catalysts in real systems consist of multi-phases, the understanding of which is far short of chemists' expectation. Density functional theory (DFT) and micro-kinetics simulations are used to investigate the activities of six mono-phase and nine bi-phase catalysts, using CO hydrogenation that is arguably the most typical reaction in heterogeneous catalysis. Excellent activities that are beyond the activity peak of traditional mono-phase volcano curves are found on some bi-phase surfaces. By analyzing these results, a new framework to understand the unexpected activities of bi-phase surfaces is proposed. Based on the framework, several principles for the design of multi-phase catalysts are suggested. The theoretical framework extends the traditional catalysis theory to understand more complex systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a method for the design of gear tooth profiles using parabolic curve as its line of action. A mathematical model, including the equation of the line of action, the equation of the tooth profile, and the equation of the conjugate tooth profile, is developed based on the meshing theory. The equation of undercutting condition is derived from the model. The influences of the two design parameters, that present the size (or shape) of the parabolic curve relative to the gear size, on the shape of tooth profiles and on the contact ratio are also studied through the design of an example drive. The strength, including the contact and the bending stresses, of the gear drive designed by using the proposed method is analyzed by an FEA simulation. A comparison of the above characteristics of the gear drive designed with the involute gear drive is also carried out in this work. The results confirm that the proposed design method is more flexible to control the shape of the tooth profile by changing the parameters of the parabola.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective Public health organizations recommend that preschool-aged children accumulate at least 3 h of physical activity (PA) daily. Objective monitoring using pedometers offers an opportunity to measure preschooler's PA and assess compliance with this recommendation. The purpose of this study was to derive step-based recommendations consistent with the 3 h PA recommendation for preschool-aged children. Method The study sample comprised 916 preschool-aged children, aged 3 to 6 years (mean age = 5.0 ± 0.8 years). Children were recruited from kindergartens located in Portugal, between 2009 and 2013. Children wore an ActiGraph GT1M accelerometer that measured PA intensity and steps per day simultaneously over a 7-day monitoring period. Receiver operating characteristic (ROC) curve analysis was used to identify the daily step count threshold associated with meeting the daily 3 hour PA recommendation. Results A significant correlation was observed between minutes of total PA and steps per day (r = 0.76, p < 0.001). The optimal step count for ≥ 3 h of total PA was 9099 steps per day (sensitivity (90%) and specificity (66%)) with area under the ROC curve = 0.86 (95% CI: 0.84 to 0.88). Conclusion Preschool-aged children who accumulate less than 9000 steps per day may be considered Insufficiently Active.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For the past 20 years, researchers have applied the Kalman filter to the modeling and forecasting the term structure of interest rates. Despite its impressive performance in in-sample fitting yield curves, little research has focused on the out-of-sample forecast of yield curves using the Kalman filter. The goal of this thesis is to develop a unified dynamic model based on Diebold and Li (2006) and Nelson and Siegel’s (1987) three-factor model, and estimate this dynamic model using the Kalman filter. We compare both in-sample and out-of-sample performance of our dynamic methods with various other models in the literature. We find that our dynamic model dominates existing models in medium- and long-horizon yield curve predictions. However, the dynamic model should be used with caution when forecasting short maturity yields