978 resultados para certified reference values


Relevância:

90.00% 90.00%

Publicador:

Resumo:

A novel approach is presented to determine mercury in urine samples, employing vortex-assisted ionic liquid dispersive liquid–liquid microextraction and microvolume back-extraction to prepare samples, and screen-printed electrodes modified with gold nanoparticles for voltammetric analysis. Mercury was extracted directly from non-digested urine samples in a water-immiscible ionic liquid, being back-extracted into an acidic aqueous solution. Subsequently, it was determined using gold nanoparticle-modified screen-printed electrodes. Under optimized microextraction conditions, standard addition calibration was applied to urine samples containing 5, 10 and 15 μg L−1 of mercury. Standard addition calibration curves using standards between 0 and 20 μg L−1 gave a high level of linearity with correlation coefficients ranging from 0.990 to 0.999 (N = 5). The limit of detection was empirical and statistically evaluated, obtaining values that ranged from 0.5 to 1.5 μg L−1, and from 1.1 to 1.3 μg L−1, respectively, which are significantly lower than the threshold level established by the World Health Organization for normal mercury content in urine (i.e., 10–20 μg L−1). A certified reference material (REC-8848/Level II) was analyzed to assess method accuracy finding 87% and 3 μg L−1 as the recovery (trueness) and standard deviation values, respectively. Finally, the method was used to analyze spiked urine samples, obtaining good agreement between spiked and found concentrations (recovery ranged from 97 to 100%).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective To measure haematological values of clinical significance for rusa deer and provide reference data for farmed animals. Design Blood samples were collected regularly from eight male rusa deer from 14 days to 27 months old. Procedure Blood samples, collected by venipuncture, were analysed within 6 hours of collection for red cell count, haemoglobin, packed cell volume, plasma glucose, white cell count and differentials. Results Haemoglobin concentrations appeared to increase with age and ranged from 6.0 to 20.9 g/dL. Packed cell volume and plasma glucose concentration did not appear to vary with age. White cell counts ranged from 6.3 to 7.0 x 10(9)/L and differential counts indicated neutrophils > lymphocytes > monocytes > eosinophils > basophils. In general, the values for packed cell volume, red cell count, mean cell volumes and mean cell haemoglobin concentrations were within ranges previously reported for captive or sedated rusa deer. Conclusions Physical restraint and resultant stress was sufficient to generate some of the effects previously reported for physically immobilised or agitated deer. The values reported here do not differ greatly from those previously reported for rusa deer and can be used as reference values for clinically healthy young farmed male rusa deer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Neste trabalho é proposto pela primeira vez, o desenvolvimento e validação de um método analítico baseado no emprego da dispersão da matriz em fase sólida (MSPD) modificada, para extração das espécies CH3Hg+ e Hg2+ em amostras de peixe e determinação por cromatografia em fase gasosa acoplada à espectrometria de massas (GC-MS). O método de extração utilizando a MSPD combina o rompimento da estrutura física da amostra, através da maceração e do uso de SiO2 como suporte sólido, com o método da extração ácida, utilizando uma solução de HCl 4,2 mol L-1 e NaCl 0,5 mol L-1. Para otimização da MSPD, foram avaliados parâmetros como massa de amostra, massa de suporte sólido, concentração de HCl, concentração de NaCl, tipo de suporte sólido e o tempo de agitação, com auxílio da metodologia de superfície de resposta. Além disso, a etapa de derivatização e a separação cromatográfica também foram otimizadas na determinação de CH3Hg+ e Hg2+ por GC-MS. O método mostrouse adequado para extração e determinação de espécies de mercúrio através da aplicação em materiais de referência certificados de fígado de peixe (DOLT-3) e músculo de peixe (DORM-2), apresentando boas concordâncias com os valores certificados e desvio padrão relativo inferior a 9,5%. Os limites de detecção foram de 0,06 e 0,12 µg g-1 para CH3Hg+ e Hg2+, respectivamente. Além disso, foi observado um significativo efeito de matriz e, por isso, a calibração foi feita com curvas preparadas com o extrato da MSPD. O método mostrou boa concordância na comparação entre a soma da concentração das espécies e a concentração de mercúrio total determinada por espectrometria de massas com plasma indutivamente acoplado com geração de vapor frio (CVG-ICP-MS), após digestão assistida por micro-ondas (MAD) em peixes do tipo atum (Thunnus thynnus), cação anjo (Squatina squatina) e cação viola (Rhinobatos blochii.).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

El propósito del presente estudio era generar los valores normativos de salto largo para niños de 9-17.9 años, e investigar las diferencias de sexo y grupo de edad

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purpose of this study was to compare the behavior of full-term small-for-gestational age (SGA) with full-term appropriate-for gestational age (AGA) infants in the first year of life. We prospectively evaluated 68 infants in the 2nd month, 67 in the 6th month and 69 in the 12th month. The Bayley Scales of Infant Development-II were used, with emphasis on the Behavior Rating Scale (BRS). The groups were similar concerning the item interest in test materials and stimuli; there was a trend toward differences in the items negative affect, hypersensitivity to test materials and adaptation to change in test materials. The mean of Raw Score was significantly lower for the SGA group in the items predominant state, liability of state of arousal, positive affect, soothability when upset, energy, exploration of objects and surroundings, orientation toward examiner. A lower BRS score was associated with the SGA group in the 2nd month.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A retrospective case-control study based on craniometrical evaluation was performed to evaluate the incidence of basilar invagination (BI). Patients with symptomatic tonsillar herniation treated surgically had craniometrical parameters evaluated based on CT scan reconstructions before surgery. BI was diagnosed when the tip of the odontoid trespassed the Chamberlain's line in three different thresholds found in the literature: 2, 5 or 6.6 mm. In the surgical group (SU), the mean distance of the tip of the odontoid process above the Chamberlain's line was 12 mm versus 1.2 mm in the control (CO) group (p<0.0001). The number of patients with BI according to the threshold used (2, 5 or 6.6 mm) in the SU group was respectively 19 (95%), 16 (80%) and 15 (75%) and in the CO group it was 15 (37%), 4 (10%) and 2 (5%).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Haemophilia and its treatment interfere with patients' life and may affect adherence to treatment. This study explored the impact of severe haemophilia A on patients' health status, especially in young adults (YA), using data from guardian(™) 1, a multinational, open-label, non-controlled phase 3 trial investigating safety and efficacy of turoctocog alfa (NovoEight(®) ) in previously treated patients aged 12 years and older with severe haemophilia A (FVIII ≤ 1%). Health status was assessed using the EuroQoL-5 dimensions (EQ-5D-3L), covering 5 dimensions of health (mobility, self-care, usual activities, pain/discomfort and anxiety/depression), and a visual analogue scale (VAS) measuring self-rated overall health status. EQ-5D was administered pretreatment (screening/baseline) and posttreatment (end-of-trial). Baseline responses to the EQ-5D dimensions and VAS were described overall and by age and compared to reference values from UK general population. Guardian(™) 1 included 150 patients (16 adolescents, 83 YA aged 16-29 and 51 adults aged 30+). All five dimensions of patients' health status were impacted at baseline. The percentage of haemophilia patients reporting problems was consistently significantly greater than age-matched general population reference values. Likewise, for all age groups mean baseline EQ-5D VAS score was significantly lower for haemophilia patients (YA: 78.0) than for the general population (YA aged 18-29: 87.3). The health status of patients with severe haemophilia A entering guardian(™) 1 was markedly poorer than that of the general population, particularly regarding mobility and pain. YA patients reported better health status than older patients, but considerably lower than that of the general YA population.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The aim of this work was to develop and to validate a methodology using HPLC for the simultaneous determination of folates and folic acid in foods. The limits of detection and the recovery rates for the vitamins in the certified reference materials were respectively 5 pg/mL and 94-108% for 5-MTHF, 7 pg/mL and 97-102% for THF, 30 pg/mL and 97.9-104% for 5-FTHF, 30 pg/mL and 95-107 for 10-FFA, 5 ng/mL and 97-102% for FA and 5 ng/mL and 98-103% for 10-MFA. Repeatability showed a coefficient of variation below 3.9% for all the vitamins. The proposed methodology was shown to be efficient when applied to different certified reference materials, namely pig's liver (BCR487), powdered milk (BCR421) and a vegetable mixture (BCR485).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Technical evaluation of analytical data is of extreme relevance considering it can be used for comparisons with environmental quality standards and decision-making as related to the management of disposal of dredged sediments and the evaluation of salt and brackish water quality in accordance with CONAMA 357/05 Resolution. It is, therefore, essential that the project manager discusses the environmental agency's technical requirements with the laboratory contracted for the follow-up of the analysis underway and even with a view to possible re-analysis when anomalous data are identified. The main technical requirements are: (1) method quantitation limits (QLs) should fall below environmental standards; (2) analyses should be carried out in laboratories whose analytical scope is accredited by the National Institute of Metrology (INMETRO) or qualified or accepted by a licensing agency; (3) chain of custody should be provided in order to ensure sample traceability; (4) control charts should be provided to prove method performance; (5) certified reference material analysis or, if that is not available, matrix spike analysis, should be undertaken and (6) chromatograms should be included in the analytical report. Within this context and with a view to helping environmental managers in analytical report evaluation, this work has as objectives the discussion of the limitations of the application of SW 846 US EPA methods to marine samples, the consequences of having data based on method detection limits (MDL) and not sample quantitation limits (SQL), and present possible modifications of the principal method applied by laboratories in order to comply with environmental quality standards.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work describes methods for the simultaneous determination of Cd and Pb by graphite furnace atomic absorption spectrometry and As by hydride generation atomic absorption spectrometry in Brazilian nuts. The samples (~ 0.300 g) were digested to clear solutions in a closed vessel microwave oven. The pyrolysis and atomization temperatures for simultaneous determinations of Cd and Pb were 1100 and 2100 °C, respectively, using 0.5% (w v-1) NH4H2PO4 + 0.03% (w v-1) Mg(NO3)2 as chemical modifier. The limits of detection (3Δ) were 3.8 μg kg-1 for As, 0.86 μg kg-1 for Cd and 13 μg kg-1 for Pb. The reliability of the entire procedures was confirmed by peach leaves (No. 1547 - NIST) certified reference material analysis and addition and recovery tests. The found concentrations presented no statistical differences at the 95% confidence level.