982 resultados para blood donor screening


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: The objective is to develop a cost-effective, reliable and non invasive screening test able to detect early CRCs and adenomas. This is done on a nucleic acids multigene assay performed on peripheral blood mononuclear cells (PBMCs). METHODS: A colonoscopy-controlled study was conducted on 179 subjects. 92 subjects (21 CRC, 30 adenoma >1 cm and 41 controls) were used as training set to generate a signature. Other 48 subjects kept blinded (controls, CRC and polyps) were used as a test set. To determine organ and disease specificity 38 subjects were used: 24 with inflammatory bowel disease (IBD),14 with other cancers (OC). Blood samples were taken and PBMCs were purified. After the RNA extraction, multiplex RT-qPCR was applied on 92 different candidate biomarkers. After different univariate and multivariate analysis 60 biomarkers with significant p-values (<0.01) were selected. 2 distinct biomarker signatures are used to separate patients without lesion from those with CRC or with adenoma, named COLOX CRC and COLOX POL. COLOX performances were validated using random resampling method, bootstrap. RESULTS: COLOX CRC and POL tests successfully separate patients without lesions from those with CRC (Se 67%, Sp 93%, AUC 0.87), and from those with adenoma > 1cm (Se 63%, Sp 83%, AUC 0.77). 6/24 patients in the IBD group and 1/14 patients in the OC group have a positive COLOX CRC. CONCLUSION: The two COLOX tests demonstrated a high Se and Sp to detect the presence of CRCs and adenomas > 1 cm. A prospective, multicenter, pivotal study is underway in order to confirm these promising results in a larger cohort.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Detection rates for adenoma and early colorectal cancer (CRC) are unsatisfactory due to low compliance towards invasive screening procedures such as colonoscopy. There is a large unmet screening need calling for an accurate, non-invasive and cost-effective test to screen for early neoplastic and pre-neoplastic lesions. Our goal is to identify effective biomarker combinations to develop a screening test aimed at detecting precancerous lesions and early CRC stages, based on a multigene assay performed on peripheral blood mononuclear cells (PBMC).Methods: A pilot study was conducted on 92 subjects. Colonoscopy revealed 21 CRC, 30 adenomas larger than 1 cm and 41 healthy controls. A panel of 103 biomarkers was selected by two approaches: a candidate gene approach based on literature review and whole transcriptome analysis of a subset of this cohort by Illumina TAG profiling. Blood samples were taken from each patient and PBMC purified. Total RNA was extracted and the 103 biomarkers were tested by multiplex RT-qPCR on the cohort. Different univariate and multivariate statistical methods were applied on the PCR data and 60 biomarkers, with significant p-value (< 0.01) for most of the methods, were selected.Results: The 60 biomarkers are involved in several different biological functions, such as cell adhesion, cell motility, cell signaling, cell proliferation, development and cancer. Two distinct molecular signatures derived from the biomarker combinations were established based on penalized logistic regression to separate patients without lesion from those with CRC or adenoma. These signatures were validated using bootstrapping method, leading to a separation of patients without lesion from those with CRC (Se 67%, Sp 93%, AUC 0.87) and from those with adenoma larger than 1cm (Se 63%, Sp 83%, AUC 0.77). In addition, the organ and disease specificity of these signatures was confirmed by means of patients with other cancer types and inflammatory bowel diseases.Conclusions: The two defined biomarker combinations effectively detect the presence of CRC and adenomas larger than 1 cm with high sensitivity and specificity. A prospective, multicentric, pivotal study is underway in order to validate these results in a larger cohort.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Currently, there is no simple direct screening method for the misuse of blood transfusions in sports. In this study, we investigated whether the measurement of iron in EDTA-plasma can serve as biomarker for such purpose. Our results revealed an increase of the plasma iron level up to 25-fold 6 h after blood re-infusion. The variable remained elevated 10-fold one day after the procedure. A specificity of 100% and a sensitivity of 93% were obtained with a proposed threshold at 45 µg/dL of plasma iron. Therefore, our test could be used as a simple, cost effective biomarker for the screening for blood transfusion misuse in sports. Copyright © 2014 John Wiley & Sons, Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES: Many patients may believe that HIV screening is included in routine preoperative work-ups. We examined what proportion of patients undergoing preoperative blood testing believed that they had been tested for HIV. METHODS: All patients hospitalized for elective orthopaedic surgery between January and December 2007 were contacted and asked to participate in a 15-min computer-assisted telephone interview (n = 1330). The primary outcome was to determine which preoperative tests patients believed had been performed from a choice of glucose, clotting, HIV serology and cholesterol, and what percentage of patients interpreted the lack of result communication as a normal or negative test. The proportion of patients agreeable to HIV screening prior to future surgery was also determined. RESULTS: A total of 991 patients (75%) completed the questionnaire. Three hundred and seventy-five of these 991 patients (38%) believed incorrectly that they had been tested for HIV preoperatively. Younger patients were significantly more likely to believe that an HIV test had been performed (mean age 46 vs. 50 years for those who did not believe that an HIV test had been performed; P < 0.0001). Of the patients who believed that a test had been performed but received no result, 96% interpreted lack of a result as a negative HIV test. Over 80% of patients surveyed stated that they would agree to routine HIV screening prior to future surgery. A higher acceptance rate was associated with younger age (mean age 47 years for those who would agree vs. 56 years for those who would not; P < 0.0001) and male sex ( P < 0.009). CONCLUSIONS: Many patients believe that a preoperative blood test routinely screens for HIV. The incorrect assumption that a lack of result communication indicates a negative test may contribute to delays in HIV diagnoses.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In Switzerland, patients may undergo "blood tests" without being informed what these are screening for. Inadequate doctor-patient communication may result in patient misunderstanding. We examined what patients in the emergency department (ED) believed they had been screened for and explored their attitudes to routine (non-targeted) human immunodeficiency virus (HIV) screening. METHODS: Between 1st October 2012 and 28th February 2013, a questionnaire-based survey was conducted among patients aged 16-70 years old presenting to the ED of Lausanne University Hospital. Patients were asked: (1) if they believed they had been screened for HIV; (2) if they agreed in principle to routine HIV screening and (3) if they agreed to be HIV tested during their current ED visit. RESULTS: Of 466 eligible patients, 411 (88%) agreed to participate. Mean age was 46 ± 16 years; 192 patients (47%) were women; 366 (89%) were Swiss or European; 113 (27%) believed they had been screened for HIV, the proportion increasing with age (p ≤0.01), 297 (72%) agreed in principle with routine HIV testing in the ED, and 138 patients (34%) agreed to be HIV tested during their current ED visit. CONCLUSION: In this ED population, 27% believed incorrectly they had been screened for HIV. Over 70% agreed in principle with routine HIV testing and 34% agreed to be tested during their current visit. These results demonstrate willingness among patients concerning routine HIV testing in the ED and highlight a need for improved doctor-patient communication about what a blood test specifically screens for.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a new concept for rapid and fully portable Prostate Specific Antigen (PSA) measurement, termed “Lab-in-a-Briefcase”, which integrates an affordable microfluidic ELISA platform utilising a melt-extruded fluoropolymer Micro Capillary Film (MCF) containing 10 bore, 200 μm internal diameter capillaries, a disposable multi-syringe aspirator (MSA) plus a sample tray pre-loaded with all required immunoassay reagents, and a portable film scanner for colorimetric signal digital quantitation. Each MSA can perform 10 replicate microfluidic immunoassays on 8 samples, allowing 80measurements to be made in less than 15 minutes based on semi-automated operation and norequirement of additional fluid handling equipment. An assay was optimised for measurement of a clinically relevant range of PSA from 0.9 to 60.0 ng/ml in 15 minutes with CVs in the order of 5% based on intra-assay variability when read using a consumer flatbed film scanner. The PSA assay performance in the MSA remained robust in the presence of undiluted or 1:2 diluted human serum or whole blood, and the matrix effect could simply be overcome by extending sample incubation times. The PSA "Lab-in-a-briefcase" is particularly suited to a low-resource health setting where diagnostic labs and automated immunoassay systems are not accessible, by allowing PSA measurement outside the laboratory using affordable equipment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this paper is to analyze 87 cases of kidney transplants obtained from nonrelated donors; in 20 of these, a donor-specific transfusion procedure4 was added to the pretreatment protocol of each recipient.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: In Brazil nationally representative donor data are limited on human immunodeficiency virus (HIV) prevalence, incidence, and residual transfusion risk. The objective of this study was to analyze HIV data obtained over 24 months by the Retrovirus Epidemiology Donor Study-II program in Brazil. STUDY DESIGN AND METHODS: Donations reactive to third-and fourth-generation immunoassays (IAs) were further confirmed by a less-sensitive (LS) IA algorithm and Western blot (WB). Incidence was calculated for first-time (FT) donors using the LS-EIA results and for repeat donors with a model developed to include all donors with a previous negative donation. Residual risk was projected by multiplying composite FT and repeat donor incidence rates by HIV marker-negative infectious window periods. RESULTS: HIV prevalence among FT donors was 92.2/ 105 donations. FT and repeat donor and composite incidences were 38.5 (95% confidence interval [CI], 25.651.4), 22.5 (95% CI, 17.6-28.0), and 27.5 (95% CI, 22.0-33.0) per 100,000 person-years, respectively. Male and community donors had higher prevalence and incidence rates than female and replacement donors. The estimated residual risk of HIV transfusion transmission was 11.3 per 106 donations (95% CI, 8.4-14.2), which could be reduced to 4.2 per 106 donations (95% CI, 3.2-5.2) by use of individual-donation nucleic acid testing (NAT). CONCLUSION: The incidence and residual transfusion risk of HIV infection are relatively high in Brazil. Implementation of NAT will not be sufficient to decrease transmission rates to levels seen in the United States or Europe; therefore, other measures focused on decreasing donations by at-risk individuals are also necessary.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Brazilian blood centers ask candidate blood donors about the number of sexual partners in the past 12 months. Candidates who report a number over the limit are deferred. We studied the implications of this practice on blood safety. STUDY DESIGN AND METHODS: We analyzed demographic characteristics, number of heterosexual partners, and disease marker rates among 689,868 donations from three Brazilian centers between July 2007 and December 2009. Donors were grouped based on maximum number of partners allowed in the past 12 months for each center. Chi-square and logistic regression analysis were conducted to examine associations between demographic characteristics, number of sex partners, and individual and overall positive markers rates for human immunodeficiency virus (HIV), human T-lymphotropic virus Types 1 and 2, hepatitis B virus, hepatitis C virus, and syphilis. RESULTS: First-time, younger, and more educated donors were associated with a higher number of recent sexual partners, as was male sex in Sao Paulo and Recife (p < 0.001). Serologic markers for HIV and syphilis and overall were associated with multiple partners in Sao Paulo and Recife (p < 0.001), but not in Belo Horizonte (p = 0.05, p = 0.94, and p = 0.75, respectively). In logistic regression analysis, number of recent sexual partners was associated with positive serologic markers (adjusted odds ratio [AOR], 1.2-1.5), especially HIV (AOR, 1.9-4.4). CONCLUSIONS: Number of recent heterosexual partners was associated with HIV positivity and overall rates of serologic markers of sexually transmitted infections. The association was not consistent across centers, making it difficult to define the best cutoff value. These findings suggest the use of recent heterosexual contacts as a potentially important deferral criterion to improve blood safety in Brazil.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: The frequent occurrence of inconclusive serology in blood banks and the absence of a gold standard test for Chagas'disease led us to examine the efficacy of the blood culture test and five commercial tests (ELISA, IIF, HAI, c-ELISA, rec-ELISA) used in screening blood donors for Chagas disease, as well as to investigate the prevalence of Trypanosoma cruzi infection among donors with inconclusive serology screening in respect to some epidemiological variables. METHODS: To obtain estimates of interest we considered a Bayesian latent class model with inclusion of covariates from the logit link. RESULTS: A better performance was observed with some categories of epidemiological variables. In addition, all pairs of tests (excluding the blood culture test) presented as good alternatives for both screening (sensitivity > 99.96% in parallel testing) and for confirmation (specificity > 99.93% in serial testing) of Chagas disease. The prevalence of 13.30% observed in the stratum of donors with inconclusive serology, means that probably most of these are non-reactive serology. In addition, depending on the level of specific epidemiological variables, the absence of infection can be predicted with a probability of 100% in this group from the pairs of tests using parallel testing. CONCLUSION: The epidemiological variables can lead to improved test results and thus assist in the clarification of inconclusive serology screening results. Moreover, all combinations of pairs using the five commercial tests are good alternatives to confirm results.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: This study aimed to investigate the frequency of positive results for hepatitis B and C, HIV and syphilis in blood donations at the Centro Regional de Hemoterapia de Ribeirão Preto, to describe donors with positive results according to some demographic and socioeconomic variables, to identify risk factors associated to these donors and the reasons that they were not detected during clinical screening. METHODS: A descriptive study was performed between July 1st 2005 and July 31st 2006 by interviewing 106 donors after medical consultations where they were informed of positive results for hepatitis B, hepatitis C, HIV or syphilis. RESULTS: There was a predominance of first-time donors, males, under 50-year olds, married individuals, from Ribeirão Preto, with elementary education, low economic status and of people who donated at the request of friends or relatives. Hepatitis C was the most frequently detected infection (56.6%), followed by hepatitis B (20.7%), HIV (12.3%) and syphilis(10.4%). About 40% of donors had omitted risk factors for different reasons: because they trusted the results of serological tests, did not feel comfortable about talking of risk factors or did not consider them relevant. Other justifications were the duration of the interview, the interviewer was unskilled, embarrassment and doubts about confidentiality. CONCLUSION: The results indicate the need for changes in the approach to clinical screening and a review of methods to attract and guide potential donors.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.