950 resultados para approximate analytical optical transfer function


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This article presents a dynamical analysis of several traffic phenomena, applying a new modelling formalism based on the embedding of statistics and Laplace transform. The new dynamic description integrates the concepts of fractional calculus leading to a more natural treatment of the continuum of the Transfer Function parameters intrinsic in this system. The results using system theory tools point out that it is possible to study traffic systems, taking advantage of the knowledge gathered with automatic control algorithms. Dynamics, Games and Science I Dynamics, Games and Science I Look Inside Other actions Export citation About this Book Reprints and Permissions Add to Papers Share Share this content on Facebook Share this content on Twitter Share this content on LinkedIn

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IEE Proceedings - Vision, Image, and Signal Processing, Vol. 147, nº 1

Relevância:

100.00% 100.00%

Publicador:

Resumo:

IEE Proceedings - Vision, Image, and Signal Processing, Vol. 147, nº 1

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper studies the dynamics of foot–ground interaction in hexapod locomotion systems. For that objective the robot motion is characterized in terms of several locomotion variables and the ground is modelled through a non-linear spring-dashpot system, with parameters based on the studies of soil mechanics. Moreover, it is adopted an algorithm with foot-force feedback to control the robot locomotion. A set of model-based experiments reveals the influence of the locomotion velocity on the foot–ground transfer function, which presents complex-order dynamics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo Energia

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thesis presented in partial fulfillment of the requirements for the degree of Doctor of Philosophy in the subject of Electrical and Computer Engineering

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUCTION: Leishmaniasis is an infectious and parasitic zoonotic, non-contagious, vector-borne disease caused by protozoa of the genus Leishmania. In Brazil, the major vector of Leishmania (Leishmania) infantum chagasi (Cunha & Chagas, 1934) is Lutzomyia longipalpis. Barra do Garças, State of Mato Grosso, was designated as a priority area by the Brazilian Ministry of Health for american visceral leishmaniasis, and it is important to identify the vector species present in this municipality. Our objective was to raise sandflies and study the influence of environmental variables on the vector density of Lutzomyia longipalpis. METHODS: We performed entomological monitoring in 3 districts using Centers for Disease Control and Prevention (CDC) light traps and recorded human cases of american visceral leishmaniasis in the city. We calculated the relative frequency and richness of sandflies and applied a transfer function model to the vector density correlate with relative humidity. RESULTS: The sandfly population was composed of 2 genera and 27 species, totaling 8,097 individuals. Monitoring identified Lutzomyia longipalpis (44%), followed by Lutzomyia lenti (18.9%), Lutzomyia whitmani (13.9%), Lutzomyia carmelinoi (9.1%), Lutzomyia evandroi (5.1%), Lutzomyia termitophila (3.3%), Lutzomyia sordellii (1.9%), and 20 other species (<4%). The male:female ratio was 3.5:1. We observed high species diversity (Dα = 6.65). Lutzomyia longipalpis showed occurrence peaks during the rainy season; there was a temporal correlation with humidity, but not with frequency or temperature. CONCLUSIONS: The presence of Lutzomyia longipalpis in the urban area of Barra do Garças underscores the changing disease profile, which was previously restricted to the wild environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fixed delays in neuronal interactions arise through synaptic and dendritic processing. Previous work has shown that such delays, which play an important role in shaping the dynamics of networks of large numbers of spiking neurons with continuous synaptic kinetics, can be taken into account with a rate model through the addition of an explicit, fixed delay. Here we extend this work to account for arbitrary symmetric patterns of synaptic connectivity and generic nonlinear transfer functions. Specifically, we conduct a weakly nonlinear analysis of the dynamical states arising via primary instabilities of the stationary uniform state. In this way we determine analytically how the nature and stability of these states depend on the choice of transfer function and connectivity. While this dependence is, in general, nontrivial, we make use of the smallness of the ratio in the delay in neuronal interactions to the effective time constant of integration to arrive at two general observations of physiological relevance. These are: 1 - fast oscillations are always supercritical for realistic transfer functions. 2 - Traveling waves are preferred over standing waves given plausible patterns of local connectivity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method of objectively determining imaging performance for a mammography quality assurance programme for digital systems was developed. The method is based on the assessment of the visibility of a spherical microcalcification of 0.2 mm using a quasi-ideal observer model. It requires the assessment of the spatial resolution (modulation transfer function) and the noise power spectra of the systems. The contrast is measured using a 0.2-mm thick Al sheet and Polymethylmethacrylate (PMMA) blocks. The minimal image quality was defined as that giving a target contrast-to-noise ratio (CNR) of 5.4. Several evaluations of this objective method for evaluating image quality in mammography quality assurance programmes have been considered on computed radiography (CR) and digital radiography (DR) mammography systems. The measurement gives a threshold CNR necessary to reach the minimum standard image quality required with regards to the visibility of a 0.2-mm microcalcification. This method may replace the CDMAM image evaluation and simplify the threshold contrast visibility test used in mammography quality.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper characterizes and evaluates the potential of three commercial CT iterative reconstruction methods (ASIR?, VEO? and iDose(4 ()?())) for dose reduction and image quality improvement. We measured CT number accuracy, standard deviation (SD), noise power spectrum (NPS) and modulation transfer function (MTF) metrics on Catphan phantom images while five human observers performed four-alternative forced-choice (4AFC) experiments to assess the detectability of low- and high-contrast objects embedded in two pediatric phantoms. Results show that 40% and 100% ASIR as well as iDose(4) levels 3 and 6 do not affect CT number and strongly decrease image noise with relative SD constant in a large range of dose. However, while ASIR produces a shift of the NPS curve apex, less change is observed with iDose(4) with respect to FBP methods. With second-generation iterative reconstruction VEO, physical metrics are even further improved: SD decreased to 70.4% at 0.5 mGy and spatial resolution improved to 37% (MTF(50%)). 4AFC experiments show that few improvements in detection task performance are obtained with ASIR and iDose(4), whereas VEO makes excellent detections possible even at an ultra-low-dose (0.3 mGy), leading to a potential dose reduction of a factor 3 to 7 (67%-86%). In spite of its longer reconstruction time and the fact that clinical studies are still required to complete these results, VEO clearly confirms the tremendous potential of iterative reconstructions for dose reduction in CT and appears to be an important tool for patient follow-up, especially for pediatric patients where cumulative lifetime dose still remains high.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An objective analysis of image quality parameters was performed for a computed radiography (CR) system using both standard single-side and prototype dual-side read plates. The pre-sampled modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE) for the systems were determined at three different beam qualities representative of pediatric chest radiography, at an entrance detector air kerma of 5 microGy. The NPS and DQE measurements were realized under clinically relevant x-ray spectra for pediatric radiology, including x-ray scatter radiations. Compared to the standard single-side read system, the MTF for the dual-side read system is reduced, but this is offset by a significant decrease in image noise, resulting in a marked increase in DQE (+40%) in the low spatial frequency range. Thus, for the same image quality, the new technology permits the CR system to be used at a reduced dose level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000 m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 min after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (AIx) and a diastolic index (AId) of pressure augmentation by reflections. At 5 min, both indices were below preexercise. At further time-points, AIx remained low, while AId progressively increased, to overshoot above preexercise at 45 min. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance-trained athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

RESUMEDurant la phase de récupération d'un exercice de course à pied d'intensité maximale ou submaximale, une augmentation de la pression artérielle systolique centrale (aortique) résultant de la réflexion des ondes de pouls sur l'arbre vasculaire est constatée chez l'individu en bonne santé. En diastole cependant, l'impact de la réflexion de ces ondes de pouls sur la pression centrale demeure inconnu durant la récupération d'un exercice.Nous avons évalué les ondes de pouls centrales systolique et diastolique chez onze athlètes d'endurance durant la phase de récupération d'un exercice de course à pied dans des conditions d'effort maximal (sur tapis de course) et lors d'un effort submaximal lors d'une course à pied de 4000 mètres en plein air sur terrain mixte.Pour chaque sujet et lors des deux exercices, l'onde de pouls a été mesurée au niveau radial par tonométrie d'aplanation durant une phase de repos précédant l'exercice, puis à 5, 15, 25, 35 et 45 minutes après la fin de l'exercice. En utilisant une fonction mathématique de transfert, l'onde de pouls centrale a été extrapolée à partir de l'onde de pouls radiale. En compilant la forme de l'onde de pouls centrale avec une mesure simultanée de la pression artérielle brachiale, un index d'augmentation de l'onde de pouls en systole (Alx) et en diastole (Als) peut être calculé, reflétant l'augmentation des pressions résultant de la réflexion des ondes sur l'arbre vasculaire périphérique.A 5 minutes de la fin de l'exercice, les deux index ont été mesurés moindres que ceux mesurés lors de la phase précédant celui-ci. Lors des mesures suivantes, Alx est resté bas, alors que Aid a progressivement augmenté pour finalement dépasser la valeur de repos après 45 minutes de récupération. Le même phénomène a été constaté pour les deux modalités d'exercice (maximal ou submaximal). Ainsi, au-delà de quelques minutes de récupération après un exercice de course d'intensité maximale ou submaximale, nous avons montré par ces investigations que les ondes de pouls réfléchies en périphérie augmentent de façon sélective la pression centrale en diastole chez l'athlète d'endurance.ABSTRACTDuring recovery from a maximal or submaximal aerobic exercise, augmentation of central (aortic) systolic pressure by reflected pressure waves is blunted in healthy humans. However, the extent to which reflected pressure waves modify the central pulse in diastole in these conditions remains unknown. We evaluated systolic and diastolic central reflected waves in 11 endurance-trained athletes on recovery from a maximal running test on a treadmill (treadmill-max) and a 4000m run in field conditions. On both occasions in each subject, the radial pulse was recorded with applanation tonometry in the resting preexercise state and then 5, 15, 25, 35, and 45 minutes after exercise termination. From the central waveform, as reconstructed by application of a generalized transfer function, we computed a systolic (Alx) and a diastolic index (Aid) of pressure augmentation by reflections. At 5 minutes, both indices were below preexercise. At further time-points, Alx remained low, while Aid progressively increased, to overshoot above preexercise at 45 minutes. The same behavior was observed with both exercise types. Beyond the first few minutes of recovery following either maximal or submaximal aerobic exercise, reflected waves selectively augment the central pressure pulse in diastole, at least in endurance- trained athletes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aquest treball és la culminació de les pràctiques realitzades al sincrotró ALBA. Situat a Cerdanyola del Vallès, ALBA és un accelerador de 3a generació que permet emmagatzemar un feix d'electrons confinat de fins a 400 mA a 3GeV d'energia, amb l'objectiu d'obtenir llum a partir dels girs provocats al feix. Els sincrotrons moderns com el d'ALBA, el que pretenen és aconseguir un major control i estabilitat de la llum. Per aconseguir-ho, cal que el feix d'electrons que creen la llum estigui controlat al màxim i la seva òrbita sigui estable. Amb aquest objectiu els sincrotrons estant implementant sistemes de Fast Orbit FeedBack (FOFB) o sistemes realimentats de correcció ràpida de l'òrbita, per realitzar correccions d'almenys 100Hz que estabilitzin el feix d'electrons amb menys d'un 10% de l'amplada del feix (5-10μm). El treball exposa el desenvolupament d'una part del sistema de correcció ràpida de l'òrbita dels electrons (FOFB) que s'està duent a terme al sincrotró ALBA. Concretament, s’han revisat els estudis previs realitzats durant la fase de disseny del sincrotró, s’han recalculat funcions de transferència i retards de tots els elements involucrats al sistema. També s’han realitzat simulacions per confirmar la viabilitat del sistema amb les noves dades i finalment s’ha desenvolupat part de la unitat de control determinant el Hardware i s'ha adquirit dades que permetran analitzar el soroll de l'òrbita que en futurs treballs determinaran millor l'algorisme de la unitat de control.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Whereas numerical modeling using finite-element methods (FEM) can provide transient temperature distribution in the component with enough accuracy, it is of the most importance the development of compact dynamic thermal models that can be used for electrothermal simulation. While in most cases single power sources are considered, here we focus on the simultaneous presence of multiple sources. The thermal model will be in the form of a thermal impedance matrix containing the thermal impedance transfer functions between two arbitrary ports. Eachindividual transfer function element ( ) is obtained from the analysis of the thermal temperature transient at node ¿ ¿ after a power step at node ¿ .¿ Different options for multiexponential transient analysis are detailed and compared. Among the options explored, small thermal models can be obtained by constrained nonlinear least squares (NLSQ) methods if the order is selected properly using validation signals. The methods are applied to the extraction of dynamic compact thermal models for a new ultrathin chip stack technology (UTCS).