943 resultados para X-rays.
Resumo:
X-ray backscatter imaging can be used for a wide range of imaging applications, in particular for industrial inspection and portal security. Currently, the application of this imaging technique to the detection of landmines is limited due to the surrounding sand or soil strongly attenuating the 10s to 100s of keV X-rays required for backscatter imaging. Here, we introduce a new approach involving a 140 MeV short-pulse (< 100 fs) electron beam generated by laser wakefield acceleration to probe the sample, which produces Bremsstrahlung X-rays within the sample enabling greater depths to be imaged. A variety of detector and scintillator configurations are examined, with the best time response seen from an absorptive coated BaF2 scintillator with a bandpass filter to remove the slow scintillation emission components. An X-ray backscatter image of an array of different density and atomic number items is demonstrated. The use of a compact laser wakefield accelerator to generate the electron source, combined with the rapid development of more compact, efficient and higher repetition rate high power laser systems will make this system feasible for applications in the field.
Laser-driven x-ray and neutron source development for industrial applications of plasma accelerators
Resumo:
Pulsed beams of energetic x-rays and neutrons from intense laser interactions with solid foils are promising for applications where bright, small emission area sources, capable of multi-modal delivery are ideal. Possible end users of laser-driven multi-modal sources are those requiring advanced non-destructive inspection techniques in industry sectors of high value commerce such as aerospace, nuclear and advanced manufacturing. We report on experimental work that demonstrates multi-modal operation of high power laser-solid interactions for neutron and x-ray beam generation. Measurements and Monte Carlo radiation transport simulations show that neutron yield is increased by a factor ∼2 when a 1 mm copper foil is placed behind a 2 mm lithium foil, compared to using a 2 cm block of lithium only. We explore x-ray generation with a 10 picosecond drive pulse in order to tailor the spectral content for radiography with medium density alloy metals. The impact of using >1 ps pulse duration on laser-accelerated electron beam generation and transport is discussed alongside the optimisation of subsequent bremsstrahlung emission in thin, high atomic number target foils. X-ray spectra are deconvolved from spectrometer measurements and simulation data generated using the GEANT4 Monte Carlo code. We also demonstrate the unique capability of laser-driven x-rays in being able to deliver single pulse high spatial resolution projection imaging of thick metallic objects. Active detector radiographic imaging of industrially relevant sample objects with a 10 ps drive pulse is presented for the first time, demonstrating that features of 200 μm size are resolved when projected at high magnification.
Resumo:
Recent measurements using an X-ray Free Electron Laser (XFEL) and an Electron Beam Ion Trap at the Linac Coherent Light Source facility highlighted large discrepancies between the observed and theoretical values for the Fe XVII 3C/3D line intensity ratio. This result raised the question of whether the theoretical oscillator strengths may be significantly in error, due to insufficiencies in the atomic structure calculations. We present time-dependent spectral modeling of this experiment and show that non-equilibrium effects can dramatically reduce the predicted 3C/3D line intensity ratio, compared with that obtained by simply taking the ratio of oscillator strengths. Once these non-equilibrium effects are accounted for, the measured line intensity ratio can be used to determine a revised value for the 3C/3D oscillator strength ratio, giving a range from 3.0 to 3.5. We also provide a framework to narrow this range further, if more precise information about the pulse parameters can be determined. We discuss the implications of the new results for the use of Fe XVII spectral features as astrophysical diagnostics and investigate the importance of time-dependent effects in interpreting XFEL-excited plasmas.
Resumo:
RESUMO - Na radiologia de intervenção, e concretamente em ortopedia, os raios X são intensamente utilizados permitindo a visualização de diversas técnicas de intervenção cirúrgica. Do ponto de vista médico as vantagens dessa prática são enormes, contudo, os profissionais de saúde envolvidos são susceptíveis de estarem expostos a valores de dose de radiação que significam a sua classificação como trabalhadores expostos. O presente estudo realizou-se num hospital e teve como objectivo obter uma estimativa das doses envolvidas em ortopedia de intervenção, utilizando várias metodologias experimentais para caracterização do campo de radiação primário e secundário. Observaram-se distintos níveis de dose de acordo com a zona anatómica exposta à radiação X: (i) gónadas — 0,02 a 3 mGy/h; (ii) cristalino — 0,06 a 1 mGy/h e (iii) mãos — 0,6 mGy/h. Tais resultados evidenciam uma clara necessidade de utilização de equipamentos de protecção e de vigilância dosimétrica pelos profissionais de saúde envolvidos no acto cirúrgico.--------------------------ABSTRACT - In intervention radiology, and more specifically in orthopaedics, X-rays are intensely used allowing the visualization of many acts of clinical intervention. From a clinical perspective, the advantages of that practice are significant; however, involved health care professionals are susceptible of being exposed to radiation dose values that mean their classification as exposed workers. The present study, performed in a hospital, aimed to obtain an estimation of the doses involved in intervention orthopaedics through several experimental methodologies in order to characterise the primary and the secondary radiation fields. Different levels of dose were observed according to the anatomic area exposed to X radiation: (i) gonads — 0.02 a 3 mGy/h; (ii) crystalline lens — 0.06 a 1 mGy/h e (iii) hands – 0.6 mGy/h. Such results denote a clear need of protection equipment use and of dosimetric surveillance by the health
Resumo:
The Energy Dispersive X-ray Diffraction System at Brock University has been used to measure the intensities of the diffraction lines of aluminum powder sample as a function of temperature. At first, intensity measurements at high temperature were not reproducible. After some modifications have been made, we were able to measure the intensities of the diffraction lines to 815K, with good accuracy and reproducibility. Therefore the changes of the Debye-Waller factor from room temperature up to 815K for aluminum were determined with precision. Our results are in good agreement with those previously published.
Resumo:
The interfilament spacing of the anterior byssus retractor muscle from Mytilus edulis was studied as the muscle was extended. It was found that variations in this spacing were very small and consistent with the hypothesis that the interfilament spacing was independent of the extension of the muscle. It was observed that the interfilament spacing was dependent on the osmolarity of the bathing medium. In concentrated solutions of the artificial seawater, the interfilament spacing decreased; while in dilute solutions of artificial seawater, it was observed that the interfilament spacing was increasing. X-ray diffraction patterns were obtained from fresh, and glutaraldehyde fixed, specimens of insect flight muscle from Sarcophaga bullata. There patterns were in general agreement with previous X-ray diffraction studies of insect flight muscle. A reflexion G at 93A was observed and interpreted as arising from diffraction in the mitochondria. Specimens of dried insect flight muscle produced a diffraction pattern consisting of arc and ring reflexions. This was interpreted as suggesting an ordered arrangement of cristae, in the mitochondria from these muscles.
Resumo:
Using the energy dispersive x ...ray diffraction (EDXD) technique, the room temperature diffraction pattern of Al powder was obtained at diffraction angles ~ 30° and 50°. From the small angle diffraction pattern the average relative intensities (IR) of the (111), (200), and (220) lines were measured to be equal to 100, 62, and 32 respectively. From the large diffraction angle IR for the (220), (311+222), (400), (331+420), and (422) lines were measured to be 100,201,17,90, and 19.5 respectively. The diffraction pattern at those two angles were obtained at several higher temperatures to measure the change in the intensities of the Al lines. From the intensity changes the increase of the Debye- Waller temperature factor, i.e ~B(T), with respect to the value at room temperature was determined to be 0.6+0.1 at 250°C, 1.10+0.15 at 350°C, 1.45+0.20 at 450°C, and 2.20±0.35 at 550°C.
Resumo:
Lead chromium oxide is a photoconductive dielectric material tha t has great potential of being used as a room temperature photodetector. In this research, we made ceramic pellets of this compound as well as potassium doped compound Pb2-xKxCr05, where x=O, 0.05, 0.125. We also investigate the properties of the lanthanum doped sample whose chemical formula is Pb1.85Lao.15Cr05' The electronic, magnetic and thermal properties of these materials have been studied. Magnetization measurements of the Pb2Cr05 sample indicate a transition at about 310 K, while for the lanthanum doped sample the transition temperature is at about 295 K indicating a paramagnetic behavior. However, the potassium doped samples are showing the transition from paramagnetic state to diamagnetic state at different temperatures for different amounts of potassium atoms present in the sample. We have studied resistivity as a function of temperature in different gas environments from 300 K to 900 K. The resistivity measurement of the parent sample indicates a conducting to insulating transition at about 300 K and upon increasing the temperature further, above 450 K the sample becomes an ionic conductor. As temperature increases a decrease in resistance is observed in the lanthanum/potassium doped samples. Using Differential Scanning Calorimetry experiment an endothermic peak is observed for the Pb2Cr05 and lanthanum/potassium doped samples at about 285 K.
Resumo:
Présentation: Cet article a été publié dans le journal : Computerised medical imaging and graphics (CMIG). Le but de cet article est de recaler les vertèbres extraites à partir d’images RM avec des vertèbres extraites à partir d’images RX pour des patients scoliotiques, en tenant compte des déformations non-rigides due au changement de posture entre ces deux modalités. À ces fins, une méthode de recalage à l’aide d’un modèle articulé est proposée. Cette méthode a été comparée avec un recalage rigide en calculant l’erreur sur des points de repère, ainsi qu’en calculant la différence entre l’angle de Cobb avant et après recalage. Une validation additionelle de la méthode de recalage présentée ici se trouve dans l’annexe A. Ce travail servira de première étape dans la fusion des images RM, RX et TP du tronc complet. Donc, cet article vérifie l’hypothèse 1 décrite dans la section 3.2.1.
Resumo:
We discuss the possibility of identifying superheavy elements from the observation of their M-shell x-ray spectra, which might occur during the collision of a superheavy element with a heavy target. The same question is discussed for the possible observation of the x-rays from the quasimolecule (quasi-superheavy element) which is formed during such a heavy-ion collision. It is shown that it is very difficult, if not impossible, to determine any information about the interesting quantum electrodynamical effects from the M-shell x-ray spectra of these quasimolecules.
Resumo:
Energies of electronic K X-rays in muonic atoms were calculated for muons in various outer orbitals and for different numbers of electrons. Energy shifts were obtained with respect to characteristic X-rays belonging to nuclear charge (Z - 1) and their possible observation is discussed. The shifts in muonic Sn as an example amount to 19, 37, and 59 eV for the muon in 5g, 6h, and 7i states respectively. However, shifts due to the number of electrons present and the electron vacancy distribution in the L-shell are significantly larger. Accurate measurements of the K X-ray energies would therefore enable us to learn more about the electronic structure during the muonic cascade.
Resumo:
Energies of muonic X-rays of the K-series of carbon, nitrogen and oxygen have been measured with an accuracy of about 15 eV. Root mean square radii of the nuclear charge distributions were deduced. The results 2.49±0.05 fm for carbon, 2.55 ±0.03 fm for nitrogen and 2.71 ±0.02 fm for oxygen are in good agreement at comparable accuracy with recent electron scattering data.
Resumo:
Na medicina equina, os problemas locomotores estão na origem da maioria das consultas veterinárias, provocando uma enorme preocupação para os proprietários e equitadores e exigindo um grande conhecimento por parte do veterinário. Assim, não são demais os estudos realizados nesta área, que permitem auxiliar os médicos veterinários sempre que se deparam com este tipo de problemas. Uma das ferramentas fundamentais para o diagnóstico das lesões ósseas e articulares nos membros é o raio-X. Desde que este foi tornado portátil, passou a ser um enorme aliado do veterinário, permitindo diagnósticos mais facilitados e imediatos no terreno. O objectivo da presente dissertação, para além de rever a bibliografia descrita acerca da incidência de lesões locomotoras, é também contribuir para a caracterização das lesões mais frequentes na medicina equina na população estudada que envolvam as estruturas óssea e articular dos membros do cavalo. As lesões locomotoras descritas no estudo, foram determinadas após uma observação rigorosa aos diferentes raios-X de 95 cavalos e os dados recolhidos foram tratados através de uma análise estatística utilizando o programa «SPSS®». Existe uma maior incidência de lesões nos membros anteriores quando comparado com os membros posteriores. Tanto o membro anterior direito, como o membro posterior direito são igualmente mais afectados do que os membros esquerdos, havendo também uma elevada distribuição das lesões em ambos os membros anteriores em simultâneo. No membro anterior, a lesão mais frequentemente diagnosticada é a osteoartrite, sendo a luxação uma das lesões menos encontradas. Para o membro posterior, é o esparvão que mais se diagnostica, contrastando com o síndrome podotroclear, que tem uma prevalência baixa. No membro anterior, a 3ª falange é uma das regiões mais afectadas, sendo a ulna uma das regiões menos afectadas. No membro posterior, é a região do curvilhão que representa um dos locais mais propícios a lesão, enquanto a 2ª falange é uma das regiões onde menos frequentemente se diagnosticam lesões no cavalo. Os resultados encontrados estão de acordo com a bibliografia descrita e sugerem a importância da continuidade deste tipo de estudos, nomeadamente abrangendo outras variáveis como a raça, a idade e o tipo de utilização do cavalo e, ainda, a utilização de outros métodos imagiológicos.
Resumo:
Measurements of the ionospheric E-region during total solar eclipses have been used to provide information about the evolution of the solar magnetic field and EUV and X-ray emissions from the solar corona and chromosphere. By measuring levels of ionisation during an eclipse and comparing these measurements with an estimate of the unperturbed ionisation levels (such as those made during a control day, where available) it is possible to estimate the percentage of ionising radiation being emitted by the solar corona and chromosphere. Previously unpublished data from the two eclipses presented here are particularly valuable as they provide information that supplements the data published to date. The eclipse of 23 October 1976 over Australia provides information in a data gap that would otherwise have spanned the years 1966 to 1991. The eclipse of 4 December 2002 over Southern Africa is important as it extends the published sequence of measurements. Comparing measurements from eclipses between 1932 and 2002 with the solar magnetic source flux reveals that changes in the solar EUV and X-ray flux lag the open source flux measurements by approximately 1.5 years. We suggest that this unexpected result comes about from changes to the relative size of the limb corona between eclipses, with the lag representing the time taken to populate the coronal field with plasma hot enough to emit the EUV and X-rays ionising our atmosphere.
Resumo:
We present high time-resolution multiwavelength observations of X-ray bursts in the low-mass X-ray binary UY Vol. Strong reprocessed signals are present in the ultraviolet and optical, lagged and smeared with respect to the X-rays. The addition of far-ultraviolet coverage for one burst allows much tighter constraints on the temperature and geometry of the reprocessing region than previously possible. A blackbody reprocessing model for this burst suggests a rise in temperatures during the burst from 18,000 to 35,000 K and an emitting area comparable to that expected for the disk and/or irradiated companion star. The lags are consistent with those expected. The single-zone blackbody model cannot reproduce the ratio of optical to ultraviolet flux during the burst, however. The discrepancy seems too large to explain with deviations from a local blackbody spectrum and more likely indicates that a range of reprocessing temperatures are required. Comparable results are derived from other bursts, and in particular the lag and smearing both appear shorter when the companion star is on the near side of the disk as predicted. The burst observed by HST also yielded a spectrum of the reprocessed light. It is dominated by continuum, with a spectral shape consistent with the temperatures derived from lightcurve modeling. Taken as a whole, our observations confirm the standard paradigm of prompt reprocessing distributed across the disk and companion star, with the response dominated by a thermalized continuum rather than by emission lines.