X-ray diffraction from Al powder using energy dispersive technique


Autoria(s): Elyaseery, Ibrahim S.
Contribuinte(s)

Department of Physics

Data(s)

09/07/2009

09/07/2009

09/07/1991

Resumo

Using the energy dispersive x ...ray diffraction (EDXD) technique, the room temperature diffraction pattern of Al powder was obtained at diffraction angles ~ 30° and 50°. From the small angle diffraction pattern the average relative intensities (IR) of the (111), (200), and (220) lines were measured to be equal to 100, 62, and 32 respectively. From the large diffraction angle IR for the (220), (311+222), (400), (331+420), and (422) lines were measured to be 100,201,17,90, and 19.5 respectively. The diffraction pattern at those two angles were obtained at several higher temperatures to measure the change in the intensities of the Al lines. From the intensity changes the increase of the Debye- Waller temperature factor, i.e ~B(T), with respect to the value at room temperature was determined to be 0.6+0.1 at 250°C, 1.10+0.15 at 350°C, 1.45+0.20 at 450°C, and 2.20±0.35 at 550°C.

Identificador

http://hdl.handle.net/10464/2235

Idioma(s)

eng

Publicador

Brock University

Palavras-Chave #X-rays--Diffraction. #X-ray spectroscopy. #X-ray crystallography. #Aluminum powder--Optical properties.
Tipo

Electronic Thesis or Dissertation