977 resultados para X-rays: individual: SGR J1935 2154


Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents the discovery and the use of x-rays at the end of the XIXth and the beginning of the XXth century. X-rays greatly impacted science and everyday life. Their existence broke the idea that knowledge had reached a limiting step. In general, people regarded x-rays as a marvel of science, but reactions against their use were also found. Several applications were proposed, especially in medicine. However, little or no attention was paid to security measures, leading to health damages and even death. The development of the radiological protection took into account the accidents with the x-rays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work is presented a versatile system for X-ray excited optical luminescence (XEOL) measurements. The apparatus was assembled from a sample holder connected to an optical fiber responsibly for the acquisition of the scintillation signal. The spectrum is registered with a CCD coupled in a spectrograph provided with diffraction gratings. The system performance was analyzed by exciting GdAlO3:Eu3+ 3.0 at.% with X-rays from a diffractometer and measuring the emission spectra. The system can be used to obtain precise and reliable spectroscopic properties of samples with various conformations without the loss of the required safety when dealing with ionizing radiations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context: BL Lacs are the most numerous extragalactic objects which are detected in Very High Energy (VHE) gamma-rays band. They are a subclass of blazars. Large flux variability amplitude, sometimes happens in very short time scale, is a common characteristic of them. Significant optical polarization is another main characteristics of BL Lacs. BL Lacs' spectra have a continuous and featureless Spectral Energy Distribution (SED) which have two peaks. Among 1442 BL Lacs in the Roma-BZB catalogue, only 51 are detected in VHE gamma-rays band. BL Lacs are most numerous (more than 50% of 514 objects) objects among the sources that are detected above 10 GeV by FERMI-LAT. Therefore, many BL Lacs are expected to be discovered in VHE gamma-rays band. However, due to the limitation on current and near future technology of Imaging Air Cherenkov Telescope, astronomers are forced to predict whether an object emits VHE gamma-rays or not. Some VHE gamma-ray prediction methods are already introduced but still are not confirmed. Cross band correlations are the building blocks of introducing VHE gamma-rays prediction method. Aims: We will attempt to investigate cross band correlations between flux energy density, luminosity and spectral index of the sample. Also, we will check whether recently discovered MAGIC J2001+435 is a typical BL Lac. Methods: We select a sample of 42 TeV BL Lacs and collect 20 of their properties within five energy bands from literature and Tuorla blazar monitoring program database. All of the data are synchronized to be comparable to each other. Finally, we choose 55 pair of datasets for cross band correlations finding and investigating whether there is any correlation between each pair. For MAGIC J2001+435 we analyze the publicly available SWIFT-XRT data, and use the still unpublished VHE gamma-rays data from MAGIC collaboration. The results are compared to the other sources of the sample. Results: Low state luminosity of multiple detected VHE gamma-rays is strongly correlated luminosities in all other bands. However, the high state does not show such strong correlations. VHE gamma-rays single detected sources have similar behaviour to the low state of multiple detected ones. Finally, MAGIC J2001+435 is a typical TeV BL Lac. However, for some of the properties this source is located at the edge of the whole sample (e.g. in terms of X-rays flux). Keywords: BL Lac(s), Population study, Correlations finding, Multi wavelengths analysis, VHE gamma-rays, gamma-rays, X-rays, Optical, Radio

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Energy Dispersive X-ray Diffraction System at Brock University has been used to measure the intensities of the diffraction lines of aluminum powder sample as a function of temperature. At first, intensity measurements at high temperature were not reproducible. After some modifications have been made, we were able to measure the intensities of the diffraction lines to 815K, with good accuracy and reproducibility. Therefore the changes of the Debye-Waller factor from room temperature up to 815K for aluminum were determined with precision. Our results are in good agreement with those previously published.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The interfilament spacing of the anterior byssus retractor muscle from Mytilus edulis was studied as the muscle was extended. It was found that variations in this spacing were very small and consistent with the hypothesis that the interfilament spacing was independent of the extension of the muscle. It was observed that the interfilament spacing was dependent on the osmolarity of the bathing medium. In concentrated solutions of the artificial seawater, the interfilament spacing decreased; while in dilute solutions of artificial seawater, it was observed that the interfilament spacing was increasing. X-ray diffraction patterns were obtained from fresh, and glutaraldehyde fixed, specimens of insect flight muscle from Sarcophaga bullata. There patterns were in general agreement with previous X-ray diffraction studies of insect flight muscle. A reflexion G at 93A was observed and interpreted as arising from diffraction in the mitochondria. Specimens of dried insect flight muscle produced a diffraction pattern consisting of arc and ring reflexions. This was interpreted as suggesting an ordered arrangement of cristae, in the mitochondria from these muscles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using the energy dispersive x ...ray diffraction (EDXD) technique, the room temperature diffraction pattern of Al powder was obtained at diffraction angles ~ 30° and 50°. From the small angle diffraction pattern the average relative intensities (IR) of the (111), (200), and (220) lines were measured to be equal to 100, 62, and 32 respectively. From the large diffraction angle IR for the (220), (311+222), (400), (331+420), and (422) lines were measured to be 100,201,17,90, and 19.5 respectively. The diffraction pattern at those two angles were obtained at several higher temperatures to measure the change in the intensities of the Al lines. From the intensity changes the increase of the Debye- Waller temperature factor, i.e ~B(T), with respect to the value at room temperature was determined to be 0.6+0.1 at 250°C, 1.10+0.15 at 350°C, 1.45+0.20 at 450°C, and 2.20±0.35 at 550°C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lead chromium oxide is a photoconductive dielectric material tha t has great potential of being used as a room temperature photodetector. In this research, we made ceramic pellets of this compound as well as potassium doped compound Pb2-xKxCr05, where x=O, 0.05, 0.125. We also investigate the properties of the lanthanum doped sample whose chemical formula is Pb1.85Lao.15Cr05' The electronic, magnetic and thermal properties of these materials have been studied. Magnetization measurements of the Pb2Cr05 sample indicate a transition at about 310 K, while for the lanthanum doped sample the transition temperature is at about 295 K indicating a paramagnetic behavior. However, the potassium doped samples are showing the transition from paramagnetic state to diamagnetic state at different temperatures for different amounts of potassium atoms present in the sample. We have studied resistivity as a function of temperature in different gas environments from 300 K to 900 K. The resistivity measurement of the parent sample indicates a conducting to insulating transition at about 300 K and upon increasing the temperature further, above 450 K the sample becomes an ionic conductor. As temperature increases a decrease in resistance is observed in the lanthanum/potassium doped samples. Using Differential Scanning Calorimetry experiment an endothermic peak is observed for the Pb2Cr05 and lanthanum/potassium doped samples at about 285 K.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Présentation: Cet article a été publié dans le journal : Computerised medical imaging and graphics (CMIG). Le but de cet article est de recaler les vertèbres extraites à partir d’images RM avec des vertèbres extraites à partir d’images RX pour des patients scoliotiques, en tenant compte des déformations non-rigides due au changement de posture entre ces deux modalités. À ces fins, une méthode de recalage à l’aide d’un modèle articulé est proposée. Cette méthode a été comparée avec un recalage rigide en calculant l’erreur sur des points de repère, ainsi qu’en calculant la différence entre l’angle de Cobb avant et après recalage. Une validation additionelle de la méthode de recalage présentée ici se trouve dans l’annexe A. Ce travail servira de première étape dans la fusion des images RM, RX et TP du tronc complet. Donc, cet article vérifie l’hypothèse 1 décrite dans la section 3.2.1.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work focuses on the analysis of the influence of environment on the relative biological effectiveness (RBE) of carbon ions on molecular level. Due to the high relevance of RBE for medical applications, such as tumor therapy, and radiation protection in space, DNA damages have been investigated in order to understand the biological efficiency of heavy ion radiation. The contribution of this study to the radiobiology research consists in the analysis of plasmid DNA damages induced by carbon ion radiation in biochemical buffer environments, as well as in the calculation of the RBE of carbon ions on DNA level by mean of scanning force microscopy (SFM). In order to study the DNA damages, besides the common electrophoresis method, a new approach has been developed by using SFM. The latter method allows direct visualisation and measurement of individual DNA fragments with an accuracy of several nanometres. In addition, comparison of the results obtained by SFM and agarose gel electrophoresis methods has been performed in the present study. Sparsely ionising radiation, such as X-rays, and densely ionising radiation, such as carbon ions, have been used to irradiate plasmid DNA in trishydroxymethylaminomethane (Tris buffer) and 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid (HEPES buffer) environments. These buffer environments exhibit different scavenging capacities for hydroxyl radical (HO0), which is produced by ionisation of water and plays the major role in the indirect DNA damage processes. Fragment distributions have been measured by SFM over a large length range, and as expected, a significantly higher degree of DNA damages was observed for increasing dose. Also a higher amount of double-strand breaks (DSBs) was observed after irradiation with carbon ions compared to X-ray irradiation. The results obtained from SFM measurements show that both types of radiation induce multiple fragmentation of the plasmid DNA in the dose range from D = 250 Gy to D = 1500 Gy. Using Tris environments at two different concentrations, a decrease of the relative biological effectiveness with the rise of Tris concentration was observed. This demonstrates the radioprotective behavior of the Tris buffer solution. In contrast, a lower scavenging capacity for all other free radicals and ions, produced by the ionisation of water, was registered in the case of HEPES buffer compared to Tris solution. This is reflected in the higher RBE values deduced from SFM and gel electrophoresis measurements after irradiation of the plasmid DNA in 20 mM HEPES environment compared to 92 mM Tris solution. These results show that HEPES and Tris environments play a major role on preventing the indirect DNA damages induced by ionising radiation and on the relative biological effectiveness of heavy ion radiation. In general, the RBE calculated from the SFM measurements presents higher values compared to gel electrophoresis data, for plasmids irradiated in all environments. Using a large set of data, obtained from the SFM measurements, it was possible to calculate the survive rate over a larger range, from 88% to 98%, while for gel electrophoresis measurements the survive rates have been calculated only for values between 96% and 99%. While the gel electrophoresis measurements provide information only about the percentage of plasmids DNA that suffered a single DSB, SFM can count the small plasmid fragments produced by multiple DSBs induced in a single plasmid. Consequently, SFM generates more detailed information regarding the amount of the induced DSBs compared to gel electrophoresis, and therefore, RBE can be calculated with more accuracy. Thus, SFM has been proven to be a more precise method to characterize on molecular level the DNA damage induced by ionizing radiations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We discuss the possibility of identifying superheavy elements from the observation of their M-shell x-ray spectra, which might occur during the collision of a superheavy element with a heavy target. The same question is discussed for the possible observation of the x-rays from the quasimolecule (quasi-superheavy element) which is formed during such a heavy-ion collision. It is shown that it is very difficult, if not impossible, to determine any information about the interesting quantum electrodynamical effects from the M-shell x-ray spectra of these quasimolecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energies of electronic K X-rays in muonic atoms were calculated for muons in various outer orbitals and for different numbers of electrons. Energy shifts were obtained with respect to characteristic X-rays belonging to nuclear charge (Z - 1) and their possible observation is discussed. The shifts in muonic Sn as an example amount to 19, 37, and 59 eV for the muon in 5g, 6h, and 7i states respectively. However, shifts due to the number of electrons present and the electron vacancy distribution in the L-shell are significantly larger. Accurate measurements of the K X-ray energies would therefore enable us to learn more about the electronic structure during the muonic cascade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Energies of muonic X-rays of the K-series of carbon, nitrogen and oxygen have been measured with an accuracy of about 15 eV. Root mean square radii of the nuclear charge distributions were deduced. The results 2.49±0.05 fm for carbon, 2.55 ±0.03 fm for nitrogen and 2.71 ±0.02 fm for oxygen are in good agreement at comparable accuracy with recent electron scattering data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Na medicina equina, os problemas locomotores estão na origem da maioria das consultas veterinárias, provocando uma enorme preocupação para os proprietários e equitadores e exigindo um grande conhecimento por parte do veterinário. Assim, não são demais os estudos realizados nesta área, que permitem auxiliar os médicos veterinários sempre que se deparam com este tipo de problemas. Uma das ferramentas fundamentais para o diagnóstico das lesões ósseas e articulares nos membros é o raio-X. Desde que este foi tornado portátil, passou a ser um enorme aliado do veterinário, permitindo diagnósticos mais facilitados e imediatos no terreno. O objectivo da presente dissertação, para além de rever a bibliografia descrita acerca da incidência de lesões locomotoras, é também contribuir para a caracterização das lesões mais frequentes na medicina equina na população estudada que envolvam as estruturas óssea e articular dos membros do cavalo. As lesões locomotoras descritas no estudo, foram determinadas após uma observação rigorosa aos diferentes raios-X de 95 cavalos e os dados recolhidos foram tratados através de uma análise estatística utilizando o programa «SPSS®». Existe uma maior incidência de lesões nos membros anteriores quando comparado com os membros posteriores. Tanto o membro anterior direito, como o membro posterior direito são igualmente mais afectados do que os membros esquerdos, havendo também uma elevada distribuição das lesões em ambos os membros anteriores em simultâneo. No membro anterior, a lesão mais frequentemente diagnosticada é a osteoartrite, sendo a luxação uma das lesões menos encontradas. Para o membro posterior, é o esparvão que mais se diagnostica, contrastando com o síndrome podotroclear, que tem uma prevalência baixa. No membro anterior, a 3ª falange é uma das regiões mais afectadas, sendo a ulna uma das regiões menos afectadas. No membro posterior, é a região do curvilhão que representa um dos locais mais propícios a lesão, enquanto a 2ª falange é uma das regiões onde menos frequentemente se diagnosticam lesões no cavalo. Os resultados encontrados estão de acordo com a bibliografia descrita e sugerem a importância da continuidade deste tipo de estudos, nomeadamente abrangendo outras variáveis como a raça, a idade e o tipo de utilização do cavalo e, ainda, a utilização de outros métodos imagiológicos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study of inflorescence and flower development in 12 species from four of the six subgenera of Gunnera (Gunneraceae) was carried out. In the species of subgenus Panke, initiation of floral apices along the partial inflorescences is acropetal but ends up in the late formation of a terminal flower, forming a cyme at maturity. The terminal flower is the largest and the most complete in terms of merosity and number of whorls and thus it is the most diagnostic in terms of species-level taxonomy. The lateral flowers undergo a basipetal gradient of organ reduction along the inflorescence, ranging from bisexual flowers (towards the distal region) to functionally (i.e. with staminodia) and structurally female flowers (towards the proximal region). Our results show that the terminal structure in Gunnera is a flower rather than a pseudanthium. The terminal flower is disymmetric, dimerous and bisexual, representing the common bauplan for Gunnera flowers. It has a differentiated perianth with two sepals and two alternate petals, the latter opposite the stamens and carpels. Comparisons with other members of the core eudicots with labile floral construction are addressed. We propose vegetative and floral putative synapomorphies for the sister-group relationship between Gunneraceae and Myrothamnaceae. (C) 2009 The Linnean Society of London, Botanical Journal of the Linnean Society, 2009, 160, 262-283.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To determine the intra-individual (physiological) variation of prostate-specific antigen (PSA) measurements in men after a benign prostatic biopsy. Sixty-four men were prospectively assessed, all of whom had a benign prostatic biopsy within the preceding 13 months. The degree of intra-individual variability was established by calculating the coefficient of variation on four PSA levels obtained from each patient weekly over a month. Six patients were subsequently diagnosed with prostate cancer and their data are presented separately. In the remaining 58 patients the median (range) individual mean PSA value was 6.3 (0.5-34.1) ng/mL. The median (range) coefficient of variation within the group was 9.5 (2.4-76.1)%. There was a clear linear relationship between mean PSA level and the standard deviation. In 48 of the 63 patients analysed, the coefficient of variation for serum PSA values in the group as a whole was greater than the variation claimed for the assay technique. The significance of the linear relationship between PSA and the standard deviation is discussed, with particular reference to those men who had a benign prostate biopsy.