996 resultados para Vascugraft(r) Arterial Prosthesis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVE: Arterial base excess and lactate levels are key parameters in the assessment of critically ill patients. The use of venous blood gas analysis may be of clinical interest when no arterial blood is available initially. METHODS: Twenty-four pigs underwent progressive normovolaemic haemodilution and subsequent progressive haemorrhage until the death of the animal. Base excess and lactate levels were determined from arterial and central venous blood after each step. In addition, base excess was calculated by the Van Slyke equation modified by Zander (BE(z)). Continuous variables were summarized as mean +/- SD and represent all measurements (n = 195). RESULTS: Base excess according to National Committee for Clinical Laboratory Standards for arterial blood was 2.27 +/- 4.12 versus 2.48 +/- 4.33 mmol(-l) for central venous blood (P = 0.099) with a strong correlation (r(2) = 0.960, P < 0.001). Standard deviation of the differences between these parameters (SD-DIFBE) did not increase (P = 0.355) during haemorrhage as compared with haemodilution. Arterial lactate was 2.66 +/- 3.23 versus 2.71 +/- 2.80 mmol(-l) in central venous blood (P = 0.330) with a strong correlation (r(2) = 0.983, P < 0.001). SD-DIFLAC increased (P < 0.001) during haemorrhage. BE(z) for central venous blood was 2.22 +/- 4.62 mmol(-l) (P = 0.006 versus arterial base excess according to National Committee for Clinical Laboratory Standards) with strong correlation (r(2) = 0.942, P < 0.001). SD-DIFBE(z)/base excess increased (P < 0.024) during haemorrhage. CONCLUSION: Central venous blood gas analysis is a good predictor for base excess and lactate in arterial blood in steady-state conditions. However, the variation between arterial and central venous lactate increases during haemorrhage. The modification of the Van Slyke equation by Zander did not improve the agreement between central venous and arterial base excess.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Onset-to-reperfusion time (ORT) has recently emerged as an essential prognostic factor in acute ischemic stroke therapy. Although favorable outcome is associated with reduced ORT, it remains unclear whether intracranial bleeding depends on ORT. We therefore sought to determine whether ORT influenced the risk and volume of intracerebral hemorrhage (ICH) after combined intravenous and intra-arterial therapy. METHODS: Based on our prospective registry, we included 157 consecutive acute ischemic stroke patients successfully recanalized with combined intravenous and intra-arterial therapy between April 2007 and October 2011. Primary outcome was any ICH within 24 hours posttreatment. Secondary outcomes included occurrence of symptomatic ICH (sICH) and ICH volume measured with the ABC/2. RESULTS: Any ICH occurred in 26% of the study sample (n=33). sICH occurred in 5.5% (n=7). Median ICH volume was 0.8 mL. ORT was increased in patients with ICH (median=260 minutes; interquartile range=230-306) compared with patients without ICH (median=226 minutes; interquartile range=200-281; P=0.008). In the setting of sICH, ORT reached a median of 300 minutes (interquartile range=276-401; P=0.004). The difference remained significant after adjustment for potential confounding factors (adjusted P=0.045 for ICH; adjusted P=0.002 for sICH). There was no correlation between ICH volume and ORT (r=0.16; P=0.33). CONCLUSIONS: ORT influences the rate but not the volume of ICH and appears to be a critical predictor of symptomatic hemorrhage after successful combined intravenous and intra-arterial therapy. To minimize the risk of bleeding, revascularization should be achieved within 4.5 hours of stroke onset.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The importance of the micromovements in the mechanism of aseptic loosening is clinically difficult to evaluate. To complete the analysis of a series of total knee arthroplasties (TKA), we used a tridimensional numerical model to study the micromovements of the tibial implant. MATERIAL AND METHODS: Fifty one patients (with 57 cemented Porous Coated Anatomic TKAs) were reviewed (mean follow-up 4.5 year). Radiolucency at the tibial bone-cement interface was sought on the AP radiographs and divided in 7 areas. The distribution of the radiolucency was then correlated with the axis of the lower limb as measured on the orthoradiograms. The tridimensional numerical model is based on the finite element method. It allowed the measurement of the cemented prosthetic tibial implant's displacements and the micromovements generated at bone-ciment interface. A total load (2000 Newton) was applied at first vertically and asymetrically on the tibial plateau, thereby simulating an axial deviation of the lower limbs. The vector's posterior inclination then permitted the addition of a tangential component to the axial load. This type of effort is generated by complex biomechanical phenomena such as knee flexion. RESULTS: 81 per cent of the 57 knees had a radiolucent line of at least 1 mm, at one or more of the tibial cement-epiphysis jonctional areas. The distribution of these lucent lines showed that they came out more frequently at the periphery of the implant. The lucent lines appeared most often under the unloaded margin of the tibial plateau, when axial deviation of lower limbs was present. Numerical simulations showed that asymetrical loading on the tibial plateau induced a subsidence of the loaded margin (0-100 microns) and lifting off at the opposite border (0-70 microns). The postero-anterior tangential component induced an anterior displacement of the tibial implant (160-220 microns), and horizontal micromovements with non homogenous distribution at the bone-ciment interface (28-54 microns). DISCUSSION: Comparison of clinical and numerical results showed a relation between the development of radiolucent lines and the unloading of the tibial implant's margin. The deleterious effect of lower limbs' axial deviation is thereby proven. The irregular distribution of lucent lines under the tibial plateau was similar of the micromovements' repartition at the bone-cement interface when tangential forces were present. A causative relation between the two phenomenaes could not however be established. Numerical simulation is a truly useful method of study; it permits to calculate micromovements which are relative, non homogenous and of very low amplitude. However, comparative clinical studies remain as essential to ensure the credibility of results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: This study was performed to compare the sensitivity of ultrasonography, computerized tomography during arterial portography, delayed computerized tomography, and magnetic resonance imaging to detect focal liver lesions. Forty three patients with primary or secondary malignant liver lesions were studied prior to surgical intervention. METHODS: The results of the imaging studies were compared with intraoperative examination of the liver, intraoperative ultrasonography and pathology results (29 patients). In the non-operated (14 patients) group, we compared the number of lesions detected by each technique. RESULTS: One hundred and forty six lesions were detected. There was 84% sensitivity with computerized tomography during arterial portography, 61.3% with delayed scan, 63.3% with magnetic resonance imaging and 51% with ultrasonography in operated patients. In patients who did not undergo surgery, magnetic resonance imaging was more sensitive in detecting lesions. CONCLUSIONS: In operated and non-operated patients series, CT during arterial portography had the highest sensitivity, but magnetic resonance imaging had the most consistent overall results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Numerous genetic loci have been associated with systolic blood pressure (SBP) and diastolic blood pressure (DBP) in Europeans. We now report genome-wide association studies of pulse pressure (PP) and mean arterial pressure (MAP). In discovery (N = 74,064) and follow-up studies (N = 48,607), we identified at genome-wide significance (P = 2.7 × 10(-8) to P = 2.3 × 10(-13)) four new PP loci (at 4q12 near CHIC2, 7q22.3 near PIK3CG, 8q24.12 in NOV and 11q24.3 near ADAMTS8), two new MAP loci (3p21.31 in MAP4 and 10q25.3 near ADRB1) and one locus associated with both of these traits (2q24.3 near FIGN) that has also recently been associated with SBP in east Asians. For three of the new PP loci, the estimated effect for SBP was opposite of that for DBP, in contrast to the majority of common SBP- and DBP-associated variants, which show concordant effects on both traits. These findings suggest new genetic pathways underlying blood pressure variation, some of which may differentially influence SBP and DBP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

If regions of the anterior pituitary gland received systemic blood via a direct arterial blood supply these regions would escape hypothalamic regulation and thus be a sequela in endocrine disorders. Since, in the untreated rat, all of the blood supply to the anterior pituitary gland is via the hypophyseal portal vessels, we hypothesized that partial interruption of the portal vessels could provoke the establishment of a direct arterial blood supply (arteriogenesis). We utilized the injection of polystyrene microspheres (15 or 9 micron diameter) into the left ventricle of the heart to test this hypothesis. Microspheres are trapped in the first capillary plexus they reach since they are too large to traverse the capillaries. No microspheres reached the anterior pituitary gland of control rats, a finding consistent with the fact that the anterior pituitary gland receives all of its blood supply via the hypophyseal portal blood vessels. Microspheres were observed in the primary portal capillary plexus in the infundibulum (median eminence), infundibular stalk (pituitary stalk), and infundibular process (pars nervosa), the first capillary plexus which they reached. A lesion of the medial basal hypothalamus (MBH) which destroyed the long portal vessels did not result in arteriogenesis since few, if any, microspheres were observed in the anterior pituitary gland. We confirmed, using vascular casts, that these lesions resulted in the long-term destruction of the primary portal capillaries in the infundibulum and of the long portal vessels. In MBH-lesioned animals it appears that all of the blood supply of the anterior pituitary gland is via short portal vessels arising from the infundibular stem and process.(ABSTRACT TRUNCATED AT 250 WORDS)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Today two largely new approaches are available for the treatment of clinical hypertension. First, captopril, an orally active angiotensin converting enzyme inhibitor, makes possible chronic blockade of the renin-angiotensin system. This compound, given alone or in combination with a diuretic, normalizes the blood pressure of most hypertensive patients. Unfortunately, because captopril may induce serious adverse effects the use of this inhibitor must be restricted to patients with high blood pressure refractory to conventional antihypertensive drugs. Second, compounds such as verapamil and nifedipine are capable of producing a marked vasodilating effect by inhibiting the entry of calcium into the vascular smooth muscle cells. However, the role of calcium channel blockers in the treatment of hypertensive disease awaits more precise definition.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.