934 resultados para Value System


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Management are keen to maximize the life span of an information system because of the high cost, organizational disruption, and risk of failure associated with the re-development or replacement of an information system. This research investigates the effects that various factors have on an information system's life span by understanding how the factors affect an information system's stability. The research builds on a previously developed two-stage model of information system change whereby an information system is either in a stable state of evolution in which the information system's functionality is evolving, or in a state of revolution, in which the information system is being replaced because it is not providing the functionality expected by its users. A case study surveyed a number of systems within one organization. The aim was to test whether a relationship existed between the base value of the volatility index (a measure of the stability of an information system) and certain system characteristics. Data relating to some 3000 user change requests covering 40 systems over a 10-year period were obtained. The following factors were hypothesized to have significant associations with the base value of the volatility index: language level (generation of language of construction), system size, system age, and the timing of changes applied to a system. Significant associations were found in the hypothesized directions except that the timing of user changes was not associated with any change in the value of the volatility index. Copyright (C) 2002 John Wiley Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives. This study aimed to determine the incidence of abdominal aortic aneurysm (AAA) in a large group of siblings of Australian AAA patients to determine if screening in this group is justified. Methods. 1254 siblings of 400 index AAA patients were identified and offered aortic ultrasound screening. An age and sex matched control group was recruited from patients having abdominal CT scans for non-vascular indications. AAA was defined by an infrarenal aortic diameter of greater than or equal to3 cm or a ratio of the infrarenal to suprarenal aortic diameter of greater than or equal to2.0. A ratio of 1.0-1.5 was considered normal, and a ratio of >1.5 to

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Frequency deviation is a common problem for power system signal processing. Many power system measurements are carried out in a fixed sampling rate assuming the system operates in its nominal frequency (50 or 60 Hz). However, the actual frequency may deviate from the normal value from time to time due to various reasons such as disturbances and subsequent system transients. Measurement of signals based on a fixed sampling rate may introduce errors under such situations. In order to achieve high precision signal measurement appropriate algorithms need to be employed to reduce the impact from frequency deviation in the power system data acquisition process. This paper proposes an advanced algorithm to enhance Fourier transform for power system signal processing. The algorithm is able to effectively correct frequency deviation under fixed sampling rate. Accurate measurement of power system signals is essential for the secure and reliable operation of power systems. The algorithm is readily applicable to such occasions where signal processing is affected by frequency deviation. Both mathematical proof and numerical simulation are given in this paper to illustrate robustness and effectiveness of the proposed algorithm. Crown Copyright (C) 2003 Published by Elsevier Science B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work the critical indices β, γ , and ν for a three-dimensional (3D) hardcore cylinder composite system with short-range interaction have been obtained. In contrast to the 2D stick system and the 3D hardcore cylinder system, the determined critical exponents do not belong to the same universality class as the lattice percolation,although they obey the common hyperscaling relation for a 3D system. It is observed that the value of the correlation length exponent is compatible with the predictions of the mean field theory. It is also shown that, by using the Alexander-Orbach conjuncture, the relation between the conductivity and the correlation length critical exponents has a typical value for a 3D lattice system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Elders lose independence and wellbeing, accompanied by decreased functions in terms of hearing, vision, strength and coordination abilities. These factors contribute to balance difficulties that eventually lead to falls. The injuries due to falls, at this age, are risky, since most of the times may cause a significant – and permanent – decrease of quality of life or, in extreme cases, death. In this context, a fall detection system can bring an added value to assist elderly people.This paper describes a system consisting of a wearable sensor unit, a smartphone and a website. When the sensor detects a fall it sends an alert using the smartphone via Bluetooth 4.0, to notify the family members or stakeholders. The sensor device includes an inertial unit, a barometer, and a temperature and humidity sensor. The website displays the log of previous falls and enables the configuration of emergency contact numbers. The proposed fall detection system is one of multiple components within a larger project under development that offers a holistic perspective on falls; the complete wearable solution will also feature, among others, physical protection (minimizing the impact of falls that occur).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, there exist various standards for individual management systems (MSs), at least, one for each stakeholder. New ones will be published. An integrated management system (IMS) aims to integrate some or all components of the business into one coherent and efficient MS. Maximizing integration is more and more a strategic priority in that it constitutes an opportunity to eliminate and/or reduce potential factors of destruction of value for the organizations and also to be more competitive and consequently promote its sustainable success. A preliminary investigation was conducted on a Portuguese industrial company which, over the years, has been adopting gradually, in whole or in part, individualized management system standards (MSSs). A research, through a questionnaire, was performed with the objective to develop, in a real business environment, an adequate and efficient IMS-QES (quality, environment, and safety) model and to potentiate for the future a generic IMS model to integrate other MSSs. The strategy and research methods have taken into consideration the case study. It was obtained a set of relevant conclusions resulting from the statistical analyses of the responses to the survey. Globally, the investigation results, by themselves, justified and prioritized the conception of a model of development of the IMS-QES and consequent definition and validation of a structure of an IMS-QES model, to be implemented at the small- and medium-sized enterprise (SME) where the investigation was conducted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nowadays, the cooperative intelligent transport systems are part of a largest system. Transportations are modal operations integrated in logistics and, logistics is the main process of the supply chain management. The supply chain strategic management as a simultaneous local and global value chain is a collaborative/cooperative organization of stakeholders, many times in co-opetition, to perform a service to the customers respecting the time, place, price and quality levels. The transportation, like other logistics operations must add value, which is achieved in this case through compression lead times and order fulfillments. The complex supplier's network and the distribution channels must be efficient and the integral visibility (monitoring and tracing) of supply chain is a significant source of competitive advantage. Nowadays, the competition is not discussed between companies but among supply chains. This paper aims to evidence the current and emerging manufacturing and logistics system challenges as a new field of opportunities for the automation and control systems research community. Furthermore, the paper forecasts the use of radio frequency identification (RFID) technologies integrated into an information and communication technologies (ICT) framework based on distributed artificial intelligence (DAI) supported by a multi-agent system (MAS), as the most value advantage of supply chain management (SCM) in a cooperative intelligent logistics systems. Logistical platforms (production or distribution) as nodes of added value of supplying and distribution networks are proposed as critical points of the visibility of the inventory, where these technological needs are more evident.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In competitive electricity markets with deep concerns for the efficiency level, demand response programs gain considerable significance. As demand response levels have decreased after the introduction of competition in the power industry, new approaches are required to take full advantage of demand response opportunities. Grid operators and utilities are taking new initiatives, recognizing the value of demand response for grid reliability and for the enhancement of organized spot markets’ efficiency. This paper proposes a methodology for the selection of the consumers that participate in an event, which is the responsibility of the Portuguese transmission network operator. The proposed method is intended to be applied in the interruptibility service implemented in Portugal, in convergence with Spain, in the context of the Iberian electricity market. This method is based on the calculation of locational marginal prices (LMP) which are used to support the decision concerning the consumers to be schedule for participation. The proposed method has been computationally implemented and its application is illustrated in this paper using a 937 bus distribution network with more than 20,000 consumers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

On the basis of its electrochemical behaviour a new flow-injection analysis (FIA) method with amperometric detection has been developed for quantification of the herbicide bentazone (BTZ) in estuarine waters. Standard solutions and samples (200 µL) were injected into a water carrier stream and both pH and ionic strength were automatically adjusted inside the manifold. Optimization of critical FIA conditions indicated that the best analytical results were obtained at an oxidation potential of 1.10 V, pH 4.5, and an overall flow-rate of 2.4 mL min–1. Analysis of real samples was performed by means of calibration curves over the concentration range 2.5x10–6 to 5.0x10–5 mol L–1, and results were compared with those obtained by use of an independent method (HPLC). The accuracy of the amperometric determinations was ascertained; errors relative to the comparison method were below 4% and sampling rates were approximately 100 samples h–1. The repeatability of the proposed method was calculated by assessing the relative standard deviation (%) of ten consecutive determinations of one sample; the value obtained was 2.1%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The electrochemical behaviour of the pesticide metam (MT) at a glassy carbon working electrode (GCE) and at a hanging mercury drop electrode (HMDE) was investigated. Different voltammetric techniques, including cyclic voltammetry (CV) and square wave voltammetry (SWV), were used. An anodic peak (independent of pH) at +1.46 V vs AgCl/Ag was observed in MTaqueous solution using the GCE. SWV calibration curves were plotted under optimized conditions (pH 2.5 and frequency 50 Hz), which showed a linear response for 17–29 mg L−1. Electrochemical reduction was also explored, using the HMDE. A well defined cathodic peak was recorded at −0.72 V vs AgCl/ Ag, dependent on pH. After optimizing the operating conditions (pH 10.1, frequency 150 Hz, potential deposition −0.20 V for 10 s), calibration curves was measured in the concentration range 2.5×10−1 to 1.0 mg L−1 using SWV. The electrochemical behaviour of this compound facilitated the development of a flow injection analysis (FIA) system with amperometric detection for the quantification of MT in commercial formulations and spiked water samples. An assessment of the optimal FIA conditions indicated that the best analytical results were obtained at a potential of +1.30 V, an injection volume of 207 μL and an overall flow rate of 2.4 ml min−1. Real samples were analysed via calibration curves over the concentration range 1.3×10−2 to 1.3 mg L−1. Recoveries from the real samples (spiked waters and commercial formulations) were between 97.4 and 105.5%. The precision of the proposed method was evaluated by assessing the relative standard deviation (RSD %) of ten consecutive determinations of one sample (1.0 mg L−1), and the value obtained was 1.5%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The tanning industry generates a high quantity of solid wastes. Therefore, there is a need to create valorization [added value] options for these wastes. The main objective of the present work was to study the effect of protein hydrolysates (HP) prepared from fleshings on leather dyeing. During previous studies it was found that the application of HP products, obtained from fleshings, in leather retannage intensified the colour of crust leather. In this work the CIELAB colour system was used to evaluate the effect of HP on retannage processes. The main conclusions of this study were: (i) HP can be used instead of a dicyanodiamide resin (Fortan DC) if the colour parameters of the standard procedure are to be maintained, and (ii) the replacement of an acrylic resin (Fortan A40) by glutaraldehyde-modified HP (GHP) results in a darker skin, and can therefore be interesting for the reduction of the quantity of dye used.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water-soluble copper(II) complex [Cu(H2R)(HL)]center dot H2O (1) was prepared by reaction of copper(II) nitrate hydrate with (E)-2-(((1-hydroxynaphthalen-2-yl)methylene)amino) benzenesulfonic acid (H2L) and diethanolamine (H3R). It was characterized by IR and ESI-MS spectroscopies, elemental and X-ray crystal structural analyses. 1 shows a high catalytic activity for the solvent-free microwave (MW) assisted oxidation of 1-phenylethanol with tert-butylhydroperoxide, leading, in the presence of TEMPO, to yields up to 85% (TON = 850) in a remarkably short reaction time (15 min, with the corresponding TOE value of 3.40 x 10(3) h(-1)) under low power (25W) MW irradiation. Crown Copyright (C) 2014 Published by Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática