994 resultados para Universal newborn hearing screening
Resumo:
Objective To evaluate the effectiveness of two screening methods (imitanciometry screening and questionnaire) to identify children at risk for conductive hearing loss, comparing this data with complete audiologic evaluation. Methods Of 507 children aged between three and six, 111 completed all procedures. The observational methods used were: imitanciometry screening, a questionnaire to identify risk factors for hearing loss and complete audiologic evaluation. Results obtained in the first two instruments were compared with results from complete audiologic evaluation (gold standard). From these comparisons, sensitivity and specificity, accuracy, positive and negative predictive values, and odds ratio were determined for the two screening methods and for the combination of both methods. Results The two methods applied in series (questionnaire and after imitanciometry screening) showed a greater odds ratio and better correlation between sensitivity and proportion of false-positives (ROC curve). Conclusion Combining the two tests in series improved screening accuracy. This combination was the best tool for identifying children at risk for conductive hearing loss.
Resumo:
Programa de doctorado: Avances en Traumatología, Medicina del Deporte y Cuidados de Heridas.
Resumo:
Newborn screening (NBS) for Cystic Fibrosis (CF) has been introduced in many countries, but there is no ideal protocol suitable for all countries. This retrospective study was conducted to evaluate whether the planned two step CF NBS with immunoreactive trypsinogen (IRT) and 7 CFTR mutations would have detected all clinically diagnosed children with CF in Switzerland.
Resumo:
BACKGROUND: Switzerland introduced newborn screening (NBS) for CF in 2011, using an IRT/DNA/IRT protocol. This paper describes the results of the first year and compares two versions of the protocol with different IRT cut-offs, particularly effects on recall rate, sensitivity and specificity. METHODS: IRT cut-offs were >45ng/ml (99.0th percentile) in period 1 (months 1-4) and >50ng/ml (99.2nd percentile) in period 2 (months 5-12). In period 2 we abstained from recalls when none of the 7 most common CF mutations were detected and IRT was <60ng/ml. RESULTS: In periods 1 and 2, 26,535 and 56,663 tests were performed. Recall rates were 0.94% and 0.48%, respectively (p<0.001), PPV increased from 23% to 47% (p=0.024) and sensitivity was 90% and 100%. CONCLUSIONS: Raising initial IRT cut-off from the 99.0th to the 99.2nd percentile and abstaining from recalls for children with an IRT<60ng/ml and carrying no major CFTR mutation significantly reduced the recall rate without affecting sensitivity.
Resumo:
Congenital Adrenal Hyperplasia (CAH), due to 21-Hydroxylase deficiency, has an estimated incidence of 1:15,000 births and can result in death, salt-wasting crisis or impaired growth. It has been proposed that early diagnosis and treatment of infants detected from newborn screening for CAH will decrease the incidence of mortality and morbidity in the affected population. The Texas Department of Health (TDH) began mandatory screening for CAH in June, 1989 and Texas is one of fourteen states to provide neonatal screening for the disorder.^ The purpose of this study was to describe the cost and effect of screening for CAH in Texas during 1994 and to compare cases first detected by screen and first detected clinically between January 1, 1990 and December 31, 1994. This study used a longitudinal descriptive research design. The data was secondary and previously collected by the Texas Department of Health. Along with the descriptive study, an economic analysis was done. The cost of the program was defined, measured and valued for four phases of screening: specimen collection, specimen testing, follow-up and diagnostic evaluation.^ There were 103 infants with Classical CAH diagnosed during the study and 71 of the cases had the more serious Salt-Wasting form of the disease. Of the infants diagnosed with Classical CAH, 60% of the cases were first detected by screen and 40% were first detected because of clinical findings before the screening results were returned. The base case cost of adding newborn screening to an existing program (excluding the cost of specimen collection) was $357,989 for 100,000 infants. The cost per case of Classical CAH diagnosed, based on the number of infants first detected by screen in 1994, was \$126,892. There were 42 infants diagnosed with the more benign Nonclassical form of the disease. When these cases were included in the total, the cost per infant to diagnose Congenital Adrenal/Hyperplasia was $87,848. ^
Resumo:
BACKGROUND Newborn screening for CF started 01/2011 in Switzerland. We investigated the parents' opinions about the information received, their feelings, and overall approval of the screening. METHODS This is a prospective questionnaire survey of all parents of positively screened children. Parents were phoned by CF-centres and invited for diagnostic investigations. They completed a questionnaire after the visit to the CF-centre. RESULTS From 2011-2013, 246 families received the questionnaire and 138 (56%) replied. Of these 77 (60%) found the information received at birth satisfactory; 124 (91%) found the information provided in the CF-centre satisfactory. Most parents (n=98, 78%) felt troubled or anxious when the CF-centre called, 51 (38%) remained anxious after the visit. Most parents (n=122; 88%) were satisfied with the screening, 4 (3%) were not, and 12 (9%) were unsure. CONCLUSIONS The smooth organisation of the screening process, with personal information by a CF specialist and short delays between this information and the final diagnostic testing, might have contributed to reduce anxiety among parents. Most families were grateful that their child had been screened, and are happy with the process.
Resumo:
BACKGROUND The aim of newborn screening (NBS) for CF is to detect children with 'classic' CF where early treatment is possible and improves prognosis. Children with inconclusive CF diagnosis (CFSPID) should not be detected, as there is no evidence for improvement through early treatment. No algorithm in current NBS guidelines explains what to do when sweat test (ST) fails. This study compares the performance of three different algorithms for further diagnostic evaluations when first ST is unsuccessful, regarding the numbers of children detected with CF and CFSPID, and the time until a definite diagnosis. METHODS In Switzerland, CF-NBS was introduced in January 2011 using an IRT-DNA-IRT algorithm followed by a ST. In children, in whom ST was not possible (no or insufficient sweat), 3 different protocols were applied between 2011 and 2014: in 2011, ST was repeated until it was successful (protocol A), in 2012 we proceeded directly to diagnostic DNA testing (protocol B), and 2013-2014, fecal elastase (FE) was measured in the stool, in order to determine a pancreas insufficiency needing immediate treatment (protocol C). RESULTS The ratio CF:CFSPID was 7:1 (27/4) with protocol A, 2:1 (22/10) with protocol B, and 14:1 (54/4) with protocol C. The mean time to definite diagnosis was significantly shorter with protocol C (33days) compared to protocol A or B (42 and 40days; p=0.014 compared to A, and p=0.036 compared to B). CONCLUSIONS The algorithm for the diagnostic part of the newborn screening used in the CF centers is important and affects the performance of a CF-NBS program with regard to the ratio CF:CFSPID and the time until definite diagnosis. Our results suggest to include FE after initial sweat test failure in the CF-NBS guidelines to keep the proportion of CFSPID low and the time until definite diagnosis short.
Resumo:
"No. 119."
Resumo:
Reuse of record except for individual research requires license from Congressional Information Service, Inc.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Background: Introducing neonatal screening procedures may not be readily accepted by parents and may increase anxiety. The acceptability of pulse oximetry screening to parents has not been previously reported. Objective: To assess maternal acceptability of pulse oximetry screening for congenital heart defects and to identify factors predictive of participation in screening. Design and setting: A questionnaire was completed by a cross-sectional sample of mothers whose babies were recruited into the PulseOx Study which investigated the test accuracy of pulse oximetry screening. Participants: A total of 119 mothers of babies with false-positive (FP) results, 15 with true-positive and 679 with true-negative results following screening. Main outcome measures: Questionnaires included measures of satisfaction with screening, anxiety, depression and perceptions of test results. Results: Participants were predominantly satisfied with screening. The anxiety of mothers given FP results was not significantly higher than that of mothers given true-negative results (median score 32.7 vs 30.0, p=0.09). White British/Irish mothers were more likely to participate in screening, with a decline rate of 5%; other ethnic groups were more likely to decline with the largest increase in declining being for Black African mothers (21%, OR 4.6, 95% CI 3.8 to 5.5). White British mothers were also less anxious (p<0.001) and more satisfied (p<0.001) than those of other ethnicities Conclusions: Pulse oximetry screening was acceptable to mothers and FP results were not found to increase anxiety. Factors leading to differences in participation and satisfaction across ethnic groups need to be identified so that staff can support parents appropriately.