991 resultados para Silane grafting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The periodic silane burst technique was employed during metalorganic chemical vapor deposition of epitaxial GaN on AlN buffer layers grown on Si (111). Periodic silicon delta doping during growth of both the AlN and GaN layers led to growth of GaN films with decreased tensile stresses and decreased threading dislocation densities, as well as films with improved quality as indicated by x-ray diffraction, micro-Raman spectroscopy, atomic force microscopy, and transmission electron microscopy. The possible mechanism of the reduction of tensile stress and the dislocation density is discussed in the paper.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Some scholars have read Virgil’s grafted tree (G. 2.78–82) as a sinister image, symptomatic of man’s perversion of nature. However, when it is placed within the long tradition of Roman accounts of grafting (in both prose and verse), it seems to reinforce a consistently positive view of the technique, its results, and its possibilities. Virgil’s treatment does represent a significant change from Republican to Imperial literature, whereby grafting went from mundane reality to utopian fantasy. This is reflected in responses to Virgil from Ovid, Columella, Calpurnius, Pliny the Elder, and Palladius (with Republican context from Cato, Varro, and Lucretius), and even in the postclassical transformation of Virgil’s biography into a magical folktale.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A prerequisite for the enrichment of antibodies screened from phage display libraries is their stable expression on a phage during multiple selection rounds. Thus, if stringent panning procedures are employed, selection is simultaneously driven by antigen affinity, stability and solubility. To take advantage of robust pre-selected scaffolds of such molecules, we grafted single-chain Fv (scFv) antibodies, previously isolated from a human phage display library after multiple rounds of in vitro panning on tumor cells, with the specificity of the clinically established murine monoclonal anti-CD22 antibody RFB4. We show that a panel of grafted scFvs retained the specificity of the murine monoclonal antibody, bound to the target antigen with high affinity (6.4-9.6 nM), and exhibited exceptional biophysical stability with retention of 89-93% of the initial binding activity after 6 days of incubation in human serum at 37degreesC. Selection of stable human scaffolds with high sequence identity to both the human germline and the rodent frameworks required only a small number of murine residues to be retained within the human frameworks in order to maintain the structural integrity of the antigen binding site. We expect this approach may be applicable for the rapid generation of highly stable humanized antibodies with low immunogenic potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metallized plastics have recently received significant interest for their useful applications in electronic devices such as for integrated circuits, packaging, printed circuits and sensor applications. In this work the metallized films were developed by electroless copper plating of polyethylene films grafted with vinyl ether of monoethanoleamine. There are several techniques for metal deposition on surface of polymers such as evaporation, sputtering, electroless plating and electrolysis. In this work the metallized films were developed by electroless copper plating of polyethylene films grafted with vinyl ether of monoethanoleamine. Polyethylene films were subjected to gamma-radiation induced surface graft copolymerization with vinyl ether of monoethanolamine. Electroless copper plating was carried out effectively on the modified films. The catalytic processes for the electroless copper plating in the presence and the absence of SnCl2 sensitization were studied and the optimum activation conditions that give the highest plating rate were determined. The effect of grafting degree on the plating rate is studied. Electroless plating conditions (bath additives, pH and temperature) were optimized. Plating rate was determined gravimetrically and spectrophotometrically at different grafting degrees. The results reveal that plating rate is a function of degree of grafting and increases with increasing grafted vinyl ether of monoethanolamine onto polyethylene. It was found that pH 13 of electroless bath and plating temperature 40°C are the optimal conditions for the plating process. The increasing of grafting degree results in faster plating rate at the same pH and temperature. The surface morphology of the metallized films was investigated using scanning electron microscopy (SEM). The adhesion strength between the metallized layer and grafted polymer was studied using tensile machine. SEM photos and adhesion measurements clarified that uniform and adhered deposits were obtained under optimum conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimized experimental conditions for extracting accurate information at subpixel length scales from analyzer-based X-ray imaging were obtained and applied to investigate bone regeneration by means of synthetic beta-TCP grafting materials in a rat calvaria model. The results showed a 30% growth in the particulate size due to bone ongrowth/ingrowth within the critical size defect over a 1-month healing period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Terpene alcohols (−)-menthol and [(1S)-endo]-(−)-borneol react with SiCl4 in the presence of base to give (MenO)3SiCl (1) and (BorO)3SiCl (2) in high yields. Hydrolysis of 1 yields (MenO)3SiOH (4) and (MenO)4Si (3). Hydrolysis of 2 yields only (BorO)3SiOH (5). The crystal structures of 3 and 5 are reported.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background
Little evidence exists to describe expected volumes of chest tube (CT) drainage after coronary artery bypass grafting (CABG).

Objectives
The study objective was to map the trajectory of CT drainage volumes from insertion to removal after CABG.

Design

This was a retrospective, descriptive study.
Patients
The study included 239 patients who underwent CABG at a single metropolitan hospital in Melbourne, Australia.

Results
The sample (N = 234), aged 68.7 years (standard deviation [SD] 9.9), was predominantly male (N = 185, 79.1%). The mean duration of CT insertion was 45.2 hours (SD 26.7), and total drainage volume was 1300.6 mL (SD 763.8). Drainage volumes plateau to 31 mL per hour, 8 hours after surgery. From 24 to 48 hours, the mean drainage was 21 mL per hour. Drainage volumes varied between genders.

Conclusions
Evidence of similar drainage patterns in other populations is difficult to locate. If the pattern of drainage shown in this study is consistent, experimental intervention studies comparing standard removal time and earlier removal are recommended. If not, prospective collection of relevant preoperative, intraoperative, and postoperative factors across multiple sites is necessary to determine which patient or practice variations influence CT drainage patterns after CABG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Glenoid component fixation remains an issue in the long-term survival of total shoulder arthroplasty. As a consequence revision of the glenoid component is becoming increasingly more common and reconstructive techniques to preserve and restore bone stock are becoming more important.

Methods In this article we describe the combined technique of impaction grafting and glenoid component exchange together with a classification of the glenoid defect with a report on four sequential cases in patients with rheumatoid arthritis with an average age of 56 years. The minimum follow-up was 34 months (range 34 months to 62 months).

Results Patients reported excellent pain relief and some improvement in motion and function. The complication rate remains low. Radiological assessment using tomograms showed good incorporation of the bone graft and minimal signs of glenoid loosening.

Conclusion The results of this study confirm that at least in the short term impaction grafting techniques used to reconstitute the glenoid in revision surgery can be successful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly performing natural rubber/silica (NR/SiO2) nanocomposite with a SiO2 loading of 2 wt% was prepared by combining similar dissolve mutually theory with latex compounding techniques. Before polymerization, double bonds were introduced onto the surface of the SiO2 particles with the silane-coupling agent. The core-shell structure silica-poly(methyl methacrylate), SiO2-PMMA, nanoparticles were formed by grafting polymerization of MMA on the surface of the modified SiO2 particles via in situ emulsion, and then NR/SiO2 nanocomposite was prepared by blending SiO2-PMMA and PMMA-modified NR (NR-PMMA). The Fourier transform infrared spectroscopy results show that PMMA has been successfully introduced onto the surface of SiO2, which can be well dispersed in NR matrix and present good interfacial adhesion with NR phase. Compared with those of pure NR, the thermal resistance and tensile properties of NR/SiO2 nanocomposite are significantly improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robust, electrically conductive, superamphiphobic fabric was prepared by vapour-phase polymerisation of 3,4-ethylenedioxythiophene (EDOT) on fabric in the presence of fluorinated decyl polyhedral oligomeric silsesquioxane (FD-POSS) and a fluorinated alkyl silane (FAS). The coated fabric had contact angles of 169° and 156° respectively to water and hexadecane, and a surface resistance in the range of 0.8–1.2 kΩ o⁻¹ . The incorporation of FD-POSS and FAS into the PEDOT layer showed a very small influence on the conductivity but improved the washing and abrasion stability considerably. The coated fabric can withstand at least 500 cycles of standard laundry and 10000 cycles of abrasion without apparently changing the superamphiphobicity, while the conductivity only had a small reduction after the washing and abrasion. More interestingly, the coating had a self-healing ability to auto-repair from chemical damages to restore the liquid repellency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A robust, superamphiphobic fabric with a novel self-healing ability to autorepair from chemical damage is prepared by a two-step wet-chemistry coating technique using an easily available material system consisting of poly(vinylidene fluoride-co-hexafluoropropylene), fluoroalkyl silane, and modified silica nanoparticles. The coated fabrics can withstand at least 600 cycles of standard laundry and 8000 cycles of abrasion without apparently changing the superamphiphobicity. The coating is also very stable to strong acid/base, ozone, and boiling treatments. After being damaged chemically, the coating can restore its super liquid-repellent properties by a short-time heating treatment or room temperature ageing. This simple but novel and effective coating system may be useful for the development of robust protective clothing for various applications.