846 resultados para Screen-printed electrode
Resumo:
Void fraction sensors are important instruments not only for monitoring two-phase flow, but for furnishing an important parameter for obtaining flow map pattern and two-phase flow heat transfer coefficient as well. This work presents the experimental results obtained with the analysis of two axially spaced multiple-electrode impedance sensors tested in an upward air-water two-phase flow in a vertical tube for void fraction measurements. An electronic circuit was developed for signal generation and post-treatment of each sensor signal. By phase shifting the electrodes supplying the signal, it was possible to establish a rotating electric field sweeping across the test section. The fundamental principle of using a multiple-electrode configuration is based on reducing signal sensitivity to the non-uniform cross-section void fraction distribution problem. Static calibration curves were obtained for both sensors, and dynamic signal analyses for bubbly, slug, and turbulent churn flows were carried out. Flow parameters such as Taylor bubble velocity and length were obtained by using cross-correlation techniques. As an application of the void fraction tested, vertical flow pattern identification could be established by using the probability density function technique for void fractions ranging from 0% to nearly 70%.
Resumo:
View of timber batten screen to north-east elevation with verandah behind.
Resumo:
View of timber batten screen to verandah behind and entrance stair, as seen from exterior.
Resumo:
View of timber batten screen to north-east elevation with verandah behind.
Resumo:
View of steel-framed timber screen to verandah.
Resumo:
Recent advances in the application of bioelectrical impedance analysis (BIA) have indicated that a more accurate approach to the estimation of total body water is to consider the impedance of the various body segments rather than simply that of the whole body. The segmental approach necessitates defining and locating the physical demarcation between both the trunk and leg and the trunk and arm. Despite the use of anatomical markers, these points of demarcation are difficult to locate with precision between subjects. There are also technical problems associated with the regional dispersion of the current distribution from one segment (cylinder) to another of different cross-sectional area. The concept of equipotentials in line with the proximal aspects of the upper land lower) limbs along the contralateral limbs was investigated and, in particular, the utility of this concept in the measurement of segmental bioimpedance. The variation of measured segmental impedance using electrode sites along these equipotentials was less than 2.0% for all of the commonly used impedance parameters. This variation is approximately equal to that expected from biological variation over the measurement time. It is recommended that the electrode sites, for the measurement of segmental bioelectrical impedance in humans, described herein are adopted in accordance with the proposals of the NM Technology Assessment Conference Statement.
Resumo:
Bosonized q-vertex operators related to the four-dimensional evaluation modules of the quantum affine superalgebra U-q[sl((2) over cap\1)] are constructed for arbitrary level k=alpha, where alpha not equal 0,-1 is a complex parameter appearing in the four-dimensional evaluation representations. They are intertwiners among the level-alpha highest weight Fock-Wakimoto modules. Screen currents which commute with the action of U-q[sl((2) over cap/1)] up to total differences are presented. Integral formulas for N-point functions of type I and type II q-vertex operators are proposed. (C) 2000 American Institute of Physics. [S0022-2488(00)00608-3].
Resumo:
No Abstract
Resumo:
Background-C- reactive protein (CRP) levels have been shown to predict a number of cardiovascular outcomes. CRP levels have also been found to be elevated in patients with abdominal aortic aneurysms (AAAs). The aim of this study was to assess the relation between CRP levels and rates of expansion of small AAAs. Methods and Results-A cohort of men with small aneurysms was identified in a trial of screening with ultrasound scanning. After initial screening, men were rescanned at 6- to 12-month intervals. CRP levels were measured at the first follow-up visit. Rates of expansion and risk factors for expansion were assessed with the use of data from 545 men who attended for at least 1 scan after CRP levels were measured. These men were followed for a median of 48 (range, 5 to 69) months. The mean annual rate of expansion was 1.6 mm. The median CRP level was 2.6 mg/L in men with the smaller AAAs (30 to 39 mm, n=433) compared with 3.5 mg/L in men with larger AAAs (40 to 54 mm, n=112) (P=0.007). The multivariate age-adjusted logistic model confirmed initial aortic diameter to be the only factor associated with rapid expansion with an odds ratio of 7.2 (95% CI, 4.3,12.2) for an initial diameter of 40 to 54 mm relative to one of 30 to 39 mm. Conclusions-Most small aneurysms expand slowly. CRP levels are elevated in larger aneurysms but do not appear to be associated with rapid expansion. The most useful predictor of aneurysmal expansion in men is aortic diameter.
Resumo:
The electrochemical oxidation of acid black 210 dye (AB-210) on the boron-doped diamond (BDD) was investigated under different pH conditions. The best performance for the AB-210 oxidation occurred in alkaline phosphate solution. This is probably due to oxidizing agents such as phosphate radicals and peroxodiphosphate ions, which can be electrochemically produced with good yields on the BDD anode, mainly in alkaline solution. Under this condition, the COD (chemical oxygen demand) removal was higher than that obtained from the model proposed by Comninellis. Electrolyses performed in phosphate buffer and in the presence of chloride ions resulted in faster COD and color removals in acid and neutral solutions, but in alkaline phosphate solution, a better performance in terms of TOC removal was obtained in the absence of chloride. Moreover, organochloride compounds were detected in all electrolyses performed in the presence of chloride. The AB-210 electrooxidation on BDD using phosphate as supporting electrolyte proved to be interesting since oxidizing species generated from phosphate ions were able to completely degrade the dye without producing organochloride compounds. (C) 2009 Elsevier Ltd. All rights reserved.
Resumo:
In this work, a fast, non destructive voltammetric method for cocaine detection in acetonitrile medium using a platinum disk electrode chemically modified with cobalt-hexacyanoferrate (CoHCFe) film is described. The deposition of CoHCFe film at platinum disk (working electrode) was carried out in aqueous solution containing NaClO(4) at 0.1 mol L(-1) as supporting electrolite. Stability studies of the film and subsequent voltammetric analysis of cocaine were made in acetonitrile medium with NaClO4 at 0.1 mol L(-1) as supporting electrolite. A reversible interaction between cocaine and CoHCFe at the film produces a proportional decrease of original peak current, due to the formation of a complex between cocaine and cobalt ions, with subsequent partial passivation of the film surface, being the intensity of current decrease used as analytical signal for cocaine. A linear dependence of cocaine detection was carried out in the range from 2.4 x 10 x 4 to 1.5 x 10(-3) mol L(-1), with a linear correlation coefficient of 0.994 and a detection limit of 1.4 x 10 x 4 mol L(-1). The analysis of confiscated samples by the proposed method indicated cocaine levels from 37% to 95% (m/m) and these results were validated by comparison to HPLC technique, being obtained good correlation between both methods. (C) 2009 Elsevier Ireland Ltd. All rights reserved.
Resumo:
We have described here a new kind of membrane material which acts as an ionic conductor on the surface of modified electrodes. Using these membranes it is possible to assemble highly efficient modified electrodes for electrochemical investigation of insoluble substrates. These materials can easily replace carbon paste electrodes and Nafion (R) for this purpose with a series of advantages. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.