926 resultados para Scaling Of Chf


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The progresses of electron devices integration have proceeded for more than 40 years following the well–known Moore’s law, which states that the transistors density on chip doubles every 24 months. This trend has been possible due to the downsizing of the MOSFET dimensions (scaling); however, new issues and new challenges are arising, and the conventional ”bulk” architecture is becoming inadequate in order to face them. In order to overcome the limitations related to conventional structures, the researchers community is preparing different solutions, that need to be assessed. Possible solutions currently under scrutiny are represented by: • devices incorporating materials with properties different from those of silicon, for the channel and the source/drain regions; • new architectures as Silicon–On–Insulator (SOI) transistors: the body thickness of Ultra-Thin-Body SOI devices is a new design parameter, and it permits to keep under control Short–Channel–Effects without adopting high doping level in the channel. Among the solutions proposed in order to overcome the difficulties related to scaling, we can highlight heterojunctions at the channel edge, obtained by adopting for the source/drain regions materials with band–gap different from that of the channel material. This solution allows to increase the injection velocity of the particles travelling from the source into the channel, and therefore increase the performance of the transistor in terms of provided drain current. The first part of this thesis work addresses the use of heterojunctions in SOI transistors: chapter 3 outlines the basics of the heterojunctions theory and the adoption of such approach in older technologies as the heterojunction–bipolar–transistors; moreover the modifications introduced in the Monte Carlo code in order to simulate conduction band discontinuities are described, and the simulations performed on unidimensional simplified structures in order to validate them as well. Chapter 4 presents the results obtained from the Monte Carlo simulations performed on double–gate SOI transistors featuring conduction band offsets between the source and drain regions and the channel. In particular, attention has been focused on the drain current and to internal quantities as inversion charge, potential energy and carrier velocities. Both graded and abrupt discontinuities have been considered. The scaling of devices dimensions and the adoption of innovative architectures have consequences on the power dissipation as well. In SOI technologies the channel is thermally insulated from the underlying substrate by a SiO2 buried–oxide layer; this SiO2 layer features a thermal conductivity that is two orders of magnitude lower than the silicon one, and it impedes the dissipation of the heat generated in the active region. Moreover, the thermal conductivity of thin semiconductor films is much lower than that of silicon bulk, due to phonon confinement and boundary scattering. All these aspects cause severe self–heating effects, that detrimentally impact the carrier mobility and therefore the saturation drive current for high–performance transistors; as a consequence, thermal device design is becoming a fundamental part of integrated circuit engineering. The second part of this thesis discusses the problem of self–heating in SOI transistors. Chapter 5 describes the causes of heat generation and dissipation in SOI devices, and it provides a brief overview on the methods that have been proposed in order to model these phenomena. In order to understand how this problem impacts the performance of different SOI architectures, three–dimensional electro–thermal simulations have been applied to the analysis of SHE in planar single and double–gate SOI transistors as well as FinFET, featuring the same isothermal electrical characteristics. In chapter 6 the same simulation approach is extensively employed to study the impact of SHE on the performance of a FinFET representative of the high–performance transistor of the 45 nm technology node. Its effects on the ON–current, the maximum temperatures reached inside the device and the thermal resistance associated to the device itself, as well as the dependence of SHE on the main geometrical parameters have been analyzed. Furthermore, the consequences on self–heating of technological solutions such as raised S/D extensions regions or reduction of fin height are explored as well. Finally, conclusions are drawn in chapter 7.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Die vorliegende Arbeit beschäftigt sich mit dem Einfluß von Kettenverzweigungen unterschiedlicher Topologien auf die statischen Eigenschaften von Polymeren. Diese Untersuchungen werden mit Hilfe von Monte-Carlo- und Molekular-Dynamik-Simulationen durchgeführt.Zunächst werden einige theoretische Konzepte und Modelle eingeführt, welche die Beschreibung von Polymerketten auf mesoskopischen Längenskalen gestatten. Es werden wichtige Bestimmungsgrößen eingeführt und erläutert, welche zur quantitativen Charakterisierung von Verzweigungsstrukturen bei Polymeren geeignet sind. Es wird ebenso auf die verwendeten Optimierungstechniken eingegangen, die bei der Implementierung des Computerprogrammes Verwendung fanden. Untersucht werden neben linearen Polymerketten unterschiedliche Topolgien -Sternpolymere mit variabler Armzahl, Übergang von Sternpolymeren zu linearen Polymeren, Ketten mit variabler Zahl von Seitenketten, reguläre Dendrimere und hyperverzweigte Strukturen - in Abhängigkeit von der Lösungsmittelqualität. Es wird zunächst eine gründliche Analyse des verwendeten Simulationsmodells an sehr langen linearen Einzelketten vorgenommen. Die Skalierungseigenschaften der linearen Ketten werden untersucht in dem gesamten Lösungsmittelbereich vom guten Lösungsmittel bis hin zu weitgehend kollabierten Ketten im schlechten Lösungsmittel. Ein wichtiges Ergebnis dieser Arbeit ist die Bestätigung der Korrekturen zum Skalenverhalten des hydrodynamischen Radius Rh. Dieses Ergebnis war möglich aufgrund der großen gewählten Kettenlängen und der hohen Qualität der erhaltenen Daten in dieser Arbeit, insbesondere bei den linearen ketten, und es steht im Widerspruch zu vielen bisherigen Simulations-Studien und experimentellen Arbeiten. Diese Korrekturen zum Skalenverhalten wurden nicht nur für die linearen Ketten, sondern auch für Sternpolymere mit unterchiedlicher Armzahl gezeigt. Für lineare Ketten wird der Einfluß von Polydispersität untersucht.Es wird gezeigt, daß eine eindeutige Abbildung von Längenskalen zwischen Simulationsmodell und Experiment nicht möglich ist, da die zu diesem Zweck verwendete dimensionslose Größe eine zu schwache Abhängigkeit von der Polymerisation der Ketten besitzt. Ein Vergleich von Simulationsdaten mit industriellem Low-Density-Polyäthylen(LDPE) zeigt, daß LDPE in Form von stark verzweigten Ketten vorliegt.Für reguläre Dendrimere konnte ein hochgradiges Zurückfalten der Arme in die innere Kernregion nachgewiesen werden.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Graphene excellent properties make it a promising candidate for building future nanoelectronic devices. Nevertheless, the absence of an energy gap is an open problem for the transistor application. In this thesis, graphene nanoribbons and pattern-hydrogenated graphene, two alternatives for inducing an energy gap in graphene, are investigated by means of numerical simulations. A tight-binding NEGF code is developed for the simulation of GNR-FETs. To speed up the simulations, the non-parabolic effective mass model and the mode-space tight-binding method are developed. The code is used for simulation studies of both conventional and tunneling FETs. The simulations show the great potential of conventional narrow GNR-FETs, but highlight at the same time the leakage problems in the off-state due to various tunneling mechanisms. The leakage problems become more severe as the width of the devices is made larger, and thus the band gap smaller, resulting in a poor on/off current ratio. The tunneling FET architecture can partially solve these problems thanks to the improved subthreshold slope; however, it is also shown that edge roughness, unless well controlled, can have a detrimental effect in the off-state performance. In the second part of this thesis, pattern-hydrogenated graphene is simulated by means of a tight-binding model. A realistic model for patterned hydrogenation, including disorder, is developed. The model is validated by direct comparison of the momentum-energy resolved density of states with the experimental angle-resolved photoemission spectroscopy. The scaling of the energy gap and the localization length on the parameters defining the pattern geometry is also presented. The results suggest that a substantial transport gap can be attainable with experimentally achievable hydrogen concentration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In this thesis, we investigated the evaporation of sessile microdroplets on different solid substrates. Three major aspects were studied: the influence of surface hydrophilicity and heterogeneity on the evaporation dynamics for an insoluble solid substrate, the influence of external process parameters and intrinsic material properties on microstructuring of soluble polymer substrates and the influence of an increased area to volume ratio in a microfluidic capillary, when evaporation is hindered. In the first part, the evaporation dynamics of pure sessile water drops on smooth self-assembled monolayers (SAMs) of thiols or disulfides on gold on mica was studied. With increasing surface hydrophilicity the drop stayed pinned longer. Thus, the total evaporation time of a given initial drop volume was shorter, since the drop surface, through which the evaporation occurs, stays longer large. Usually, for a single drop the volume decreased linearly with t1.5, t being the evaporation time, for a diffusion-controlled evaporation process. However, when we measured the total evaporation time, ttot, for multiple droplets with different initial volumes, V0, we found a scaling of the form V0 = attotb. The more hydrophilic the substrate was, the more showed the scaling exponent a tendency to an increased value up to 1.6. This can be attributed to an increasing evaporation rate through a thin water layer in the vicinity of the drop. Under the assumption of a constant temperature at the substrate surface a cooling of the droplet and thus a decreased evaporation rate could be excluded as a reason for the different scaling exponent by simulations performed by F. Schönfeld at the IMM, Mainz. In contrast, for a hairy surface, made of dialkyldisulfide SAMs with different chain lengths and a 1:1 mixture of hydrophilic and hydrophobic end groups (hydroxy versus methyl group), the scaling exponent was found to be ~ 1.4. It increased to ~ 1.5 with increasing hydrophilicity. A reason for this observation can only be speculated: in the case of longer hydrophobic alkyl chains the formation of an air layer between substrate and surface might be favorable. Thus, the heat transport to the substrate might be reduced, leading to a stronger cooling and thus decreased evaporation rate. In the second part, the microstructuring of polystyrene surfaces by drops of toluene, a good solvent, was investigated. For this a novel deposition technique was developed, with which the drop can be deposited with a syringe. The polymer substrate is lying on a motorized table, which picks up the pendant drop by an upward motion until a liquid bridge is formed. A consecutive downward motion of the table after a variable delay, i.e. the contact time between drop and polymer, leads to the deposition of the droplet, which can evaporate. The resulting microstructure is investigated in dependence of the processes parameters, i.e. the approach and the retraction speed of the substrate and the delay between them, and in dependence of the intrinsic material properties, i.e. the molar mass and the type of the polymer/solvent system. The principal equivalence with the microstructuring by the ink-jet technique was demonstrated. For a high approach and retraction speed of 9 mm/s and no delay between them, a concave microtopology was observed. In agreement with the literature, this can be explained by a flow of solvent and the dissolved polymer to the rim of the pinned droplet, where polymer is accumulated. This effect is analogue to the well-known formation of ring-like stains after the evaporation of coffee drops (coffee-stain effect). With decreasing retraction speed down to 10 µm/s the resulting surface topology changes from concave to convex. This can be explained with the increasing dissolution of polymer into the solvent drop prior to the evaporation. If the polymer concentration is high enough, gelation occurs instead of a flow to the rim and the shape of the convex droplet is received. With increasing delay time from below 0 ms to 1s the depth of the concave microwells decreases from 4.6 µm to 3.2 µm. However, a convex surface topology could not be obtained, since for longer delay times the polymer sticks to the tip of the syringe. Thus, by changing the delay time a fine-tuning of the concave structure is accomplished, while by changing the retraction speed a principal change of the microtopolgy can be achieved. We attribute this to an additional flow inside the liquid bridge, which enhanced polymer dissolution. Even if the pendant drop is evaporating about 30 µm above the polymer surface without any contact (non-contact mode), concave structures were observed. Rim heights as high as 33 µm could be generated for exposure times of 20 min. The concave structure exclusively lay above the flat polymer surface outside the structure even after drying. This shows that toluene is taken up permanently. The increasing rim height, rh, with increasing exposure time to the solvent vapor obeys a diffusion law of rh = rh0  tn, with n in the range of 0.46 ~ 0.65. This hints at a non-Fickian swelling process. A detailed analysis showed that the rim height of the concave structure is modulated, unlike for the drop deposition. This is due to the local stress relaxation, which was initiated by the increasing toluene concentration in the extruded polymer surface. By altering the intrinsic material parameters i.e. the polymer molar mass and the polymer/solvent combination, several types of microstructures could be formed. With increasing molar mass from 20.9 kDa to 1.44 MDa the resulting microstructure changed from convex, to a structure with a dimple in the center, to concave, to finally an irregular structure. This observation can be explained if one assumes that the microstructuring is dominated by two opposing effects, a decreasing solubility with increasing polymer molar mass, but an increasing surface tension gradient leading to instabilities of Marangoni-type. Thus, a polymer with a low molar mass close or below the entanglement limit is subject to a high dissolution rate, which leads to fast gelation compared to the evaporation rate. This way a coffee-rim like effect is eliminated early and a convex structure results. For high molar masses the low dissolution rate and the low polymer diffusion might lead to increased surface tension gradients and a typical local pile-up of polymer is found. For intermediate polymer masses around 200 kDa, the dissolution and evaporation rate are comparable and the typical concave microtopology is found. This interpretation was supported by a quantitative estimation of the diffusion coefficient and the evaporation rate. For a different polymer/solvent system, polyethylmethacrylate (PEMA)/ethylacetate (EA), exclusively concave structures were found. Following the statements above this can be interpreted with a lower dissolution rate. At low molar masses the concentration of PEMA in EA most likely never reaches the gelation point. Thus, a concave instead of a convex structure occurs. At the end of this section, the optically properties of such microstructures for a potential application as microlenses are studied with laser scanning confocal microscopy. In the third part, the droplet was confined into a glass microcapillary to avoid evaporation. Since here, due to an increased area to volume ratio, the surface properties of the liquid and the solid walls became important, the influence of the surface hydrophilicity of the wall on the interfacial tension between two immiscible liquid slugs was investigated. For this a novel method for measuring the interfacial tension between the two liquids within the capillary was developed. This technique was demonstrated by measuring the interfacial tensions between slugs of pure water and standard solvents. For toluene, n-hexane and chloroform 36.2, 50.9 and 34.2 mN/m were measured at 20°C, which is in a good agreement with data from the literature. For a slug of hexane in contact with a slug of pure water containing ethanol in a concentration range between 0 and 70 (v/v %), a difference of up to 6 mN/m was found, when compared to commercial ring tensiometry. This discrepancy is still under debate.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In the first part of the thesis, we propose an exactly-solvable one-dimensional model for fermions with long-range p-wave pairing decaying with distance as a power law. We studied the phase diagram by analyzing the critical lines, the decay of correlation functions and the scaling of the von Neumann entropy with the system size. We found two gapped regimes, where correlation functions decay (i) exponentially at short range and algebraically at long range, (ii) purely algebraically. In the latter the entanglement entropy is found to diverge logarithmically. Most interestingly, along the critical lines, long-range pairing breaks also the conformal symmetry. This can be detected via the dynamics of entanglement following a quench. In the second part of the thesis we studied the evolution in time of the entanglement entropy for the Ising model in a transverse field varying linearly in time with different velocities. We found different regimes: an adiabatic one (small velocities) when the system evolves according the instantaneous ground state; a sudden quench (large velocities) when the system is essentially frozen to its initial state; and an intermediate one, where the entropy starts growing linearly but then displays oscillations (also as a function of the velocity). Finally, we discussed the Kibble-Zurek mechanism for the transition between the paramagnetic and the ordered phase.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A method for automatic scaling of oblique ionograms has been introduced. This method also provides a rejection procedure for ionograms that are considered to lack sufficient information, depicting a very good success rate. Observing the Kp index of each autoscaled ionogram, can be noticed that the behavior of the autoscaling program does not depend on geomagnetic conditions. The comparison between the values of the MUF provided by the presented software and those obtained by an experienced operator indicate that the procedure developed for detecting the nose of oblique ionogram traces is sufficiently efficient and becomes much more efficient as the quality of the ionograms improves. These results demonstrate the program allows the real-time evaluation of MUF values associated with a particular radio link through an oblique radio sounding. The automatic recognition of a part of the trace allows determine for certain frequencies, the time taken by the radio wave to travel the path between the transmitter and receiver. The reconstruction of the ionogram traces, suggests the possibility of estimating the electron density between the transmitter and the receiver, from an oblique ionogram. The showed results have been obtained with a ray-tracing procedure based on the integration of the eikonal equation and using an analytical ionospheric model with free parameters. This indicates the possibility of applying an adaptive model and a ray-tracing algorithm to estimate the electron density in the ionosphere between the transmitter and the receiver An additional study has been conducted on a high quality ionospheric soundings data set and another algorithm has been designed for the conversion of an oblique ionogram into a vertical one, using Martyn's theorem. This allows a further analysis of oblique soundings, throw the use of the INGV Autoscala program for the automatic scaling of vertical ionograms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Zeitreihen sind allgegenwärtig. Die Erfassung und Verarbeitung kontinuierlich gemessener Daten ist in allen Bereichen der Naturwissenschaften, Medizin und Finanzwelt vertreten. Das enorme Anwachsen aufgezeichneter Datenmengen, sei es durch automatisierte Monitoring-Systeme oder integrierte Sensoren, bedarf außerordentlich schneller Algorithmen in Theorie und Praxis. Infolgedessen beschäftigt sich diese Arbeit mit der effizienten Berechnung von Teilsequenzalignments. Komplexe Algorithmen wie z.B. Anomaliedetektion, Motivfabfrage oder die unüberwachte Extraktion von prototypischen Bausteinen in Zeitreihen machen exzessiven Gebrauch von diesen Alignments. Darin begründet sich der Bedarf nach schnellen Implementierungen. Diese Arbeit untergliedert sich in drei Ansätze, die sich dieser Herausforderung widmen. Das umfasst vier Alignierungsalgorithmen und ihre Parallelisierung auf CUDA-fähiger Hardware, einen Algorithmus zur Segmentierung von Datenströmen und eine einheitliche Behandlung von Liegruppen-wertigen Zeitreihen.rnrnDer erste Beitrag ist eine vollständige CUDA-Portierung der UCR-Suite, die weltführende Implementierung von Teilsequenzalignierung. Das umfasst ein neues Berechnungsschema zur Ermittlung lokaler Alignierungsgüten unter Verwendung z-normierten euklidischen Abstands, welches auf jeder parallelen Hardware mit Unterstützung für schnelle Fouriertransformation einsetzbar ist. Des Weiteren geben wir eine SIMT-verträgliche Umsetzung der Lower-Bound-Kaskade der UCR-Suite zur effizienten Berechnung lokaler Alignierungsgüten unter Dynamic Time Warping an. Beide CUDA-Implementierungen ermöglichen eine um ein bis zwei Größenordnungen schnellere Berechnung als etablierte Methoden.rnrnAls zweites untersuchen wir zwei Linearzeit-Approximierungen für das elastische Alignment von Teilsequenzen. Auf der einen Seite behandeln wir ein SIMT-verträgliches Relaxierungschema für Greedy DTW und seine effiziente CUDA-Parallelisierung. Auf der anderen Seite führen wir ein neues lokales Abstandsmaß ein, den Gliding Elastic Match (GEM), welches mit der gleichen asymptotischen Zeitkomplexität wie Greedy DTW berechnet werden kann, jedoch eine vollständige Relaxierung der Penalty-Matrix bietet. Weitere Verbesserungen umfassen Invarianz gegen Trends auf der Messachse und uniforme Skalierung auf der Zeitachse. Des Weiteren wird eine Erweiterung von GEM zur Multi-Shape-Segmentierung diskutiert und auf Bewegungsdaten evaluiert. Beide CUDA-Parallelisierung verzeichnen Laufzeitverbesserungen um bis zu zwei Größenordnungen.rnrnDie Behandlung von Zeitreihen beschränkt sich in der Literatur in der Regel auf reellwertige Messdaten. Der dritte Beitrag umfasst eine einheitliche Methode zur Behandlung von Liegruppen-wertigen Zeitreihen. Darauf aufbauend werden Distanzmaße auf der Rotationsgruppe SO(3) und auf der euklidischen Gruppe SE(3) behandelt. Des Weiteren werden speichereffiziente Darstellungen und gruppenkompatible Erweiterungen elastischer Maße diskutiert.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND: Congestive heart failure (CHF) is a major public health problem. The use of B-type natriuretic peptide (BNP) tests shows promising diagnostic accuracy. Herein, we summarize the evidence on the accuracy of BNP tests in the diagnosis of CHF and compare the performance of rapid enzyme-linked immunosorbent assay (ELISA) and standard radioimmunosorbent assay (RIA) tests. METHODS: We searched electronic databases and the reference lists of included studies, and we contacted experts. Data were extracted on the study population, the type of test used, and methods. Receiver operating characteristic (ROC) plots and summary ROC curves were produced and negative likelihood ratios pooled. Random-effect meta-analysis and metaregression were used to combine data and explore sources of between-study heterogeneity. RESULTS: Nineteen studies describing 22 patient populations (9 ELISA and 13 RIA) and 9093 patients were included. The diagnosis of CHF was verified by echocardiography, radionuclide scan, or echocardiography combined with clinical criteria. The pooled negative likelihood ratio overall from random-effect meta-analysis was 0.18 (95% confidence interval [CI], 0.13-0.23). It was lower for the ELISA test (0.12; 95% CI, 0.09-0.16) than for the RIA test (0.23; 95% CI, 0.16-0.32). For a pretest probability of 20%, which is typical for patients with suspected CHF in primary care, a negative result of the ELISA test would produce a posttest probability of 2.9%; a negative RIA test, a posttest probability of 5.4%. CONCLUSIONS: The use of BNP tests to rule out CHF in primary care settings could reduce demand for echocardiography. The advantages of rapid ELISA tests need to be balanced against their higher cost.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A simulation model adopting a health system perspective showed population-based screening with DXA, followed by alendronate treatment of persons with osteoporosis, or with anamnestic fracture and osteopenia, to be cost-effective in Swiss postmenopausal women from age 70, but not in men. INTRODUCTION: We assessed the cost-effectiveness of a population-based screen-and-treat strategy for osteoporosis (DXA followed by alendronate treatment if osteoporotic, or osteopenic in the presence of fracture), compared to no intervention, from the perspective of the Swiss health care system. METHODS: A published Markov model assessed by first-order Monte Carlo simulation was refined to reflect the diagnostic process and treatment effects. Women and men entered the model at age 50. Main screening ages were 65, 75, and 85 years. Age at bone densitometry was flexible for persons fracturing before the main screening age. Realistic assumptions were made with respect to persistence with intended 5 years of alendronate treatment. The main outcome was cost per quality-adjusted life year (QALY) gained. RESULTS: In women, costs per QALY were Swiss francs (CHF) 71,000, CHF 35,000, and CHF 28,000 for the main screening ages of 65, 75, and 85 years. The threshold of CHF 50,000 per QALY was reached between main screening ages 65 and 75 years. Population-based screening was not cost-effective in men. CONCLUSION: Population-based DXA screening, followed by alendronate treatment in the presence of osteoporosis, or of fracture and osteopenia, is a cost-effective option in Swiss postmenopausal women after age 70.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Stereoselectivity has to be considered for pharmacodynamic and pharmacokinetic features of ketamine. Stereoselective biotransformation of ketamine was investigated in equine microsomes in vitro. Concentration curves were constructed over time, and enzyme activity was determined for different substrate concentrations using equine liver and lung microsomes. The concentrations of R/S-ketamine and R/S-norketamine were determined by enantioselective capillary electrophoresis. A two-phase model based on Hill kinetics was used to analyze the biotransformation of R/S-ketamine into R/S-norketamine and, in a second step, into R/S-downstream metabolites. In liver and lung microsomes, levels of R-ketamine exceeded those of S-ketamine at all time points and S-norketamine exceeded R-norketamine at time points below the maximum concentration. In liver and lung microsomes, significant differences in the enzyme velocity (V(max)) were observed between S- and R-norketamine formation and between V(max) of S-norketamine formation when S-ketamine was compared to S-ketamine of the racemate. Our investigations in microsomal reactions in vitro suggest that stereoselective ketamine biotransformation in horses occurs in the liver and the lung with a slower elimination of S-ketamine in the presence of R-ketamine. Scaling of the in vitro parameters to liver and lung organ clearances provided an excellent fit with previously published in vivo data and confirmed a lung first-pass effect.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PCR tests for the rapid and valid detection of methicillin-resistant Staphylococcus aureus (MRSA) are now available. We evaluated the costs associated with contact screening for MRSA carriage in a tertiary-care hospital with low MRSA endemicity. Between 1 October 2005 and 28 February 2006, 232 patients were screened during 258 screening episodes (644 samples) for MRSA carriage by GenoType MRSA Direct (Hain Lifescience GmbH, Nehren, Germany). Conventional culture confirmed all PCR results. According to in-house algorithms, 34 of 258 screening episodes (14.7%) would have qualified for preemptive contact isolation, but such isolation was not done upon negative PCR results. MRSA carriage was detected in 4 (1.5%) of 258 screening episodes (i.e., in four patients), of which none qualified for preemptive contact isolation. The use of PCR for all 258 screening episodes added costs (in Swiss francs [CHF]) of CHF 104,328.00 and saved CHF 38,528.00 (for preemptive isolation). The restriction of PCR screening to the 34 episodes that qualified for preemptive contact isolation and screening all others by culture would have lowered costs for PCR to only CHF 11,988.00, a savings of CHF 38,528.00. Therefore, PCR tests are valuable for the rapid detection of MRSA carriers, but high costs require the careful evaluation of their use. In patient populations with low MRSA endemicity, the broad use of PCR probably is not cost-effective.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Alteration of neurohormonal homeostasis is a hallmark of the pathophysiology of chronic heart failure (CHF). In particular, overactivation of the renin-angiotensin-aldosterone system and the sympathetic catecholaminergic system is consistently observed. Chronic overactivation of these hormonal pathways leads to a detrimental arrhythmogenic remodeling of cardiac tissue due to dysregulation of cardiac ion channels. Sudden cardiac death resulting from ventricular arrhythmias is a major cause of mortality in patients with CHF. All the drug classes known to reduce mortality in patients with CHF are neurohormonal blockers. The aim of this review was to provide an overview of how cardiac ion channels are regulated by hormones known to play a central role in the pathogenesis of CHF.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Renal dysfunction represents a frequent comorbidity in patients with in chronic heart failure and is not only a strong predictor of mortality, but also causally linked to the development and progression of CHF. Mechanisms involved in the cross-talk between the kidney and the heart include the up-regulated sympathetic nerve system, activation of the renin-angiotensin-aldosterone system, vasopressin release and decreased activity of arterial baroreceptors and natriuretic peptides resulting in abnormal salt and water retention. The main therapeutic goals for patients with the so-called cardiorenal syndrome is the normalization of volume status while avoiding overdiuresis and renal dysfunction as well as the implementation of an evidence-based pharmacologic treatment to improve patient outcome. If these two goals are not achieved with conventional therapy, renal replacement therapy should be discussed in an interdisciplinary approach. All current renal replacement techniques have proved to be useful in controlling hypervolemia and ameliorating functional cardiac parameters and quality of life in patients with heart failure. Nevertheless, the influence of renal replacement therapy on long-term survival of affected patients has not been addressed in large controlled studies.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An utrastructural morphometric study of the postnatally remodelling lungs of the quokka wallaby (Setonix brachyurus) was undertaken. Allometric scaling of the volumes of the parenchymal components against body mass was performed. Most parameters showed a positive correlation with body mass in all the developmental stages, except the volume of type II pneumocytes during the alveolar stage. The interstitial tissue and type II cell volumes increased slightly faster than body mass in the saccular stage, their growth rates declining in the alveolar stage. Conversely, type I pneumocyte volumes increased markedly in both the saccular and alveolar stages. Both capillary and endothelial volumes as well as the capillary and airspace surface areas showed highest rates of increase during the alveolar stage, at which time the rate was notably higher than that of the body mass. The pulmonary diffusion capacity increased gradually, the rate being highest in the alveolar stage and the adult values attained were comparable to those of eutherians.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

BACKGROUND Prognostic classification of congestive heart failure (CHF) is difficult and only possible with the help of additional diagnostic tools. B-type natriuretic peptide (BNP) has been used as a diagnostic and prognostic marker for patients (pts) with CHF. In this study, the clinical value of BNP for stratification and treatment of pts with CHF was evaluated. PATIENTS AND METHODS 33 out-pts with CHF (age 57 +/- 12 years) were included. Left-ventricular (LV) ejection fraction (EF) was 27 +/- 8% (mean +/- SD) and NYHA-class 2.4 +/- 0.7. Following parameters were measured: BNP and sodium from blood samples, exercise performance from 6-minute walking test (6MWT, meters) (n = 18), LV end-diastolic diameter (LVEDD) and LV mass (LVM) from 2D-echocardiography (n = 33), as well as LV end-diastolic pressure (LVEDP, n = 23) and systemic vascular resistance (SVR, n = 20) from heart-catheterisation. Ten pts were hospitalised in the preceding 6 months because of worsening CHF or for optimisation of medical therapy. BNP was measured at the beginning and end of the hospital-stay. Follow-up was for 1 year. RESULTS Pts with a high NYHA-class had a higher BNP (pg/ml) than those with a low NYHA- class: NYHA I 51 +/- 20, II 281 +/- 223, III 562+/-346 and IV 1061 +/- 126 pg/ml (p = 0.002). BNP correlated with LVEDP (r = 0.50, p <0.02), SVR (r =0.49, p <0.03) and inversely with 6MWT (r =-0.60, p <0.009), LVEF (r = -0.49, p <0.004) and sodium (r = -0.36, p = 0.04). In the hospitalised pts, mean BNP (pg/ml) was 881 +/- 695 at admission,and 532 +/- 435 at discharge (n.s.). Decrease in BNPduring hospitalisation paralleled weight-loss and was significantly greater in patients with >1000 pg/ml BNP at admission (n = 5) as compared to the 5 patients with BNP <1000 (p <0.03). Patients with an adverse event during 1-year follow-up had significantly higher BNP both at steady-state (603 +/-359 pg/ml) and at time of decompensation than patients with a favourable outcome (227 +/- 218 pg/ml,p <0.001). CONCLUSIONS BNP correlates well with the clinical severity of CHF (NYHA-class) and is directly related to filling pressure (LVEDP), LV function(LVEF) and exercise performance (6 MWT). Furthermore, BNP has prognostic impact with regard to adverse clinical events.