951 resultados para Radiação Ultra violeta
Resumo:
Due to their detrimental effects on human health, scientific interest in ultrafine particles (UFP), has been increasing but available information is far from comprehensive. Children, who represent one of the most susceptible subpopulation, spend the majority of time in schools and homes. Thus, the aim of this study is to (1) assess indoor levels of particle number concentrations (PNC) in ultrafine and fine (20–1000 nm) range at school and home environments and (2) compare indoor respective dose rates for 3- to 5-yr-old children. Indoor particle number concentrations in range of 20–1000 nm were consecutively measured during 56 d at two preschools (S1 and S2) and three homes (H1–H3) situated in Porto, Portugal. At both preschools different indoor microenvironments, such as classrooms and canteens, were evaluated. The results showed that total mean indoor PNC as determined for all indoor microenvironments were significantly higher at S1 than S2. At homes, indoor levels of PNC with means ranging between 1.09 × 104 and 1.24 × 104 particles/cm3 were 10–70% lower than total indoor means of preschools (1.32 × 104 to 1.84 × 104 particles/cm3). Nevertheless, estimated dose rates of particles were 1.3- to 2.1-fold higher at homes than preschools, mainly due to longer period of time spent at home. Daily activity patterns of 3- to 5-yr-old children significantly influenced overall dose rates of particles. Therefore, future studies focusing on health effects of airborne pollutants always need to account for children’s exposures in different microenvironments such as homes, schools, and transportation modes in order to obtain an accurate representation of children overall exposure.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
Objectivos: Com a generalização dos procedimentos endovasculares, cresce a preocupação com os efeitos deletérios que a execução continuada de tais procedimentos radiológicos acarreta. Com este trabalho pretendeu-se avaliar e quantificar a distribuição pela equipa cirúrgica da exposição à radiação dispersa, emitida por um aparelho portátil de radioscopia com arco cirúrgico (arco em C), durante a utilização em bloco operatório. Material e métodos: O registo e avaliação da dose de radiação foram efectuados em sala do bloco operatório reproduzindo as condições habituais em que decorrem os procedimentos endovasculares. Para a simulação geométrica do tórax do doente foi utilizado um fantoma cilíndrico de polimetilmetacrilato (PMMA) com 15 cm de espessura. A radiação dispersa foi medida para o local do cirurgião, ajudante, anestesista e enfermeira instrumentista, através de um monitor de radiação portátil RaySafe Xi Survey Detector, tendo sido ajustada a medição para a avaliação da taxa de dose de exposição à radiação em mGy/s a diversas alturas do solo e distâncias do doente. Utilizou-se ainda o detetor RaySafe Xi R/F para a medição da taxa de dose de exposição na superfície de entrada da pele do doente. As medições foram efectuadas em modo de fl uoroscopia pulsada de 4 quadros por segundo (qps), subtração digital e roadmap, com a combinação dos três modos de magnifi cação electrónica disponíveis (Mag1, Mag2 e Mag3). Em todos os casos foi considerada a Dose 3, o nível de dose máxima do aparelho que fornece a melhor qualidade de imagem através do controlo automático em tempo real do contraste e do brilho. Resultados: A análise dos dados permitiu determinar a distribuição da radiação dispersa pela equipa assistente, constatando-se como nível máximo de exposição, a altura ao solo de 120 cm no modo de subtracção digital e roadmap. A este nível, a intensidade da radiação dispersa em relação à taxa de dose de exposição na superfície de entrada da pele do doente é distribuída em 0,47% pelo cirurgião, 0,21% pelo anestesista, 0,32% pelo ajudante e 0,13% pela enfermeira instrumentista. A utilização de subtração digital e roadmap aumentou o nível de radiação cerca de 5 vezes em relação à fluoroscopia pulsada a 4 qps, tanto na taxa de dose de exposição na superfície de entrada da pele do doente como na radiação dispersa pela equipa. Quando utilizados os meios de proteção radiológica os níveis de radiação foram consideravelmente inferiores. Conclusões: Atendendo à dispersão prevista da radiação determinou-se que a proximidade da ampola aumenta a quantidade de radiação dispersa que atinge o corpo. Quando utilizado o equipamento de proteção individual, os níveis de radiação dispersa são consideravelmente menores e permitem doses acumuladas abaixo dos limites aceitáveis.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
BACKGROUND: Patient-controlled epidural analgesia with low concentrations of anesthetics is effective in reducing labor pain. The aim of this study was to assess and compare two ultra-low dose regimens of ropivacaine and sufentanil (0.1% ropivacaine plus 0.5 μg.ml-1 sufentanil vs. 0.06% ropivacaine plus 0.5 μg.ml-1 sufentanil) on the intervals between boluses and the duration of labor. MATERIAL AND METHODS: In this non-randomized prospective study, conducted between January and July 2010, two groups of parturients received patient-controlled epidural analgesia: Group I (n = 58; 1 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil) and Group II (n = 57; 0.6 mg.ml-1 ropivacaine + 0.5 μg.ml-1 sufentanil). Rescue doses of ropivacaine at the concentration of the assigned group without sufentanil were administered as necessary. Pain, local anesthetic requirements, neuraxial blockade characteristics, labor and neonatal outcomes, and maternal satisfaction were recorded. RESULTS: The ropivacaine dose was greater in Group I (9.5 [7.7-12.7] mg.h-1 vs. 6.1 [5.1-9.8 mg.h-1], p < 0.001). A time increase between each bolus was observed in Group I (beta = 32.61 min, 95% CI [25.39; 39.82], p < 0.001), whereas a time decrease was observed in Group II (beta = -1.40 min, 95% CI [-2.44; -0.36], p = 0.009). The duration of the second stage of labor in Group I was significantly longer than that in Group II (78 min vs. 65 min, p < 0.001). CONCLUSIONS: Parturients receiving 0.06% ropivacaine exhibited less evidence of cumulative effects and exhibited faster second stage progression than those who received 0.1% ropivacaine.
Resumo:
E feito um estudo da ultra-estrutura da forma epismastigota do Trypanosoma cruzi mantida em meio de cultivo acelular. O núcleo das formas em divisão apresenta um aspecto homogêneo. Microtúbulos intranucleares são observados durante a divisão. No entanto, a membrana nuclear permanece íntegra. O citoplasma apresenta-se com vacúolos de dimensões e aspectos variados. Com o método do ácido periódico-tiosemicarbazida-proteinato de prata, polissacaríáeos e/ou glicoproteínas foram localizados na membrana celular e na membrana que delimita certos vacúolos citoplasmáticos.
Resumo:
Dissertação para obtenção do Grau de Mestre em Genética Molecular e Biomedicina
Resumo:
Os aa. estudaram as alterações ultra-estruturais do hepatócito na forma aguda, toxêmica, da esquístossomose em sete pacientes, membros de uma mesma família, infectatos em idênticas condições em um córrego existente no município de Sabará (MG) e não tratados especificamente para a esquistossomose. O estudo vem confirmar a nossa assertiva de que, na esquistossomose, não hâ um ataque direto e sistematizado aos hepatócitos e que as lesões destes são secundárias e decorrem, principalmente, das alterações do sistema vascular estromático. Nos sete casos estudados as alterações ultra-estruturais foram inespecfficas, pouco acentuadas e se caracterizaram sobretudo pelas modificações das organelas citoplasmáticas (dilatação das cisternas do reticulo, apagamento das cristas mitocondriais, desacoplamento de ribossomas, acúmulo de glicogênio). Foi freqüente, também, a presença de lisossomosvolumosos, inclusões e corpos residuais nos hepatócitos Estes achados à microscopia eletrônica espelham o comportamento funcional do hepatócito na vigência da forma aguda, toxêmica, da esquistossomose e explicam o freqüente encontro de células claras à microscopia óptica.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
CONSTRUÇÃO 2012, Universidade de Coimbra, Dez. 2012