980 resultados para RODRIGUEZ, JUAN ANTONIO
Resumo:
This paper analyzes the use of artificial neural networks (ANNs) for predicting the received power/path loss in both outdoor and indoor links. The approach followed has been a combined use of ANNs and ray-tracing, the latter allowing the identification and parameterization of the so-called dominant path. A complete description of the process for creating and training an ANN-based model is presented with special emphasis on the training process. More specifically, we will be discussing various techniques to arrive at valid predictions focusing on an optimum selection of the training set. A quantitative analysis based on results from two narrowband measurement campaigns, one outdoors and the other indoors, is also presented.
Resumo:
Background The prognosis of patients bearing high grade glioma remains dismal. Epidermal Growth Factor Receptor (EGFR) is well validated as a primary contributor of glioma initiation and progression. Nimotuzumab is a humanized monoclonal antibody that recognizes the EGFR extracellular domain and reaches Central Nervous System tumors, in nonclinical and clinical setting. While it has similar activity when compared to other anti-EGFR antibodies, it does not induce skin toxicity or hypomagnesemia. Methods A randomized, double blind, multicentric clinical trial was conducted in high grade glioma patients (41 anaplastic astrocytoma and 29 glioblastoma multiforme) that received radiotherapy plus nimotuzumab or placebo. Treatment and placebo groups were well-balanced for the most important prognostic variables. Patients received 6 weekly doses of 200 mg nimotuzumab or placebo together with irradiation as induction therapy. Maintenance treatment was given for 1 year with subsequent doses administered every 3 weeks. The objectives of this study were to assess the comparative overall survival, progression free survival, response rate, immunogenicity and safety. Results The median cumulative dose was 3200 mg of nimotuzumab given over a median number of 16 doses. The combination of nimotuzumab and RT was well-tolerated. The most prevalent related adverse reactions included nausea, fever, tremors, anorexia and hepatic test alteration. No anti-idiotypic response was detected, confirming the antibody low immunogenicity. The mean and median survival time for subjects treated with nimotuzumab was 31.06 and 17.76 vs. 21.07 and 12.63 months for the control group. Conclusions In this randomized trial, nimotuzumab showed an excellent safety profile and significant survival benefit in combination with irradiation.
Resumo:
Santamaría, José Miguel; Pajares, Eterio; Olsen, Vickie; Merino, Raquel; Eguíluz, Federico (eds.)
Resumo:
Idazleen nahia, esatariaren lehentasunak eta antolaketa mugaketak kontuan izanik, helburu anitzeko eredu bat zehaztea da, horrela Osakidetzako erietxe konkretu bateko jarduera zehaztu ahal izango dugu eta beraz, baita aurrekontuaren esleipena. Aldi berean, aurrekontu zuzkidura doituz, zentroaren baliabideen erabilpenaren efizientzia azter dezakegu eta orokorrean, zentroaren osasun-laguntzen emaitzak hobetzen lagundu dezakete.
Resumo:
Impact detection in aeronautical structures allows predicting their future reliability and performance. An impact can produce microscopic fissures that could evolve into fractures or even the total collapse of the structure, so it is important to know the location and severity of each impact. For this purpose, optical fibers with Bragg gratings are used to analyze each impact and the vibrations generated by them. In this paper it is proven that optical fibers with Bragg gratings can be used to detect impacts, and also that a high-frequency interrogator is necessary to collect valuable information about the impacts. The use of two interrogators constitutes the main novelty of this paper.
Resumo:
The design and development of a plastic optical fiber (POF) macrobend temperature sensor is presented. The sensor has a linear response versus temperature at a fixed bend radius, with a sensitivity of 1.92.10(-3) (degrees C)(-1). The sensor system used a dummy fiber-optic sensor for reference purposes having a resolution below 0.3 degrees C. A comprehensive experimental analysis was carried out to provide insight into the effect of different surrounding media on practical macro-bend POF sensor implementation. Experimental results are successfully compared with bend loss calculations.
Resumo:
Polymer optical fibers (POFs) doped with organic dyes can be used to make efficient lasers and amplifiers due to the high gains achievable in short distances. This paper analyzes the peculiarities of light amplification in POFs through some experimental data and a computational model capable of carrying out both power and spectral analyses. We investigate the emission spectral shifts and widths and on the optimum signal wavelength and pump power as functions of the fiber length, the fiber numerical aperture and the radial distribution of the dopant. Analyses for both step-index and graded-index POFs have been done.
Resumo:
Background: Patients with chronic obstructive pulmonary disease (COPD) often experience exacerbations of the disease that require hospitalization. Current guidelines offer little guidance for identifying patients whose clinical situation is appropriate for admission to the hospital, and properly developed and validated severity scores for COPD exacerbations are lacking. To address these important gaps in clinical care, we created the IRYSS-COPD Appropriateness Study. Methods/Design: The RAND/UCLA Appropriateness Methodology was used to identify appropriate and inappropriate scenarios for hospital admission for patients experiencing COPD exacerbations. These scenarios were then applied to a prospective cohort of patients attending the emergency departments (ED) of 16 participating hospitals. Information was recorded during the time the patient was evaluated in the ED, at the time a decision was made to admit the patient to the hospital or discharge home, and during follow-up after admission or discharge home. While complete data were generally available at the time of ED admission, data were often missing at the time of decision making. Predefined assumptions were used to impute much of the missing data. Discussion: The IRYSS-COPD Appropriateness Study will validate the appropriateness criteria developed by the RAND/UCLA Appropriateness Methodology and thus better delineate the requirements for admission or discharge of patients experiencing exacerbations of COPD. The study will also provide a better understanding of the determinants of outcomes of COPD exacerbations, and evaluate the equity and variability in access and outcomes in these patients.
Resumo:
It is well known in the scientific community that some remote sensing instruments assume that sample volumes present homogeneous conditions within a defined meteorological profile. At complex topographic sites and under extreme meteorological conditions, this assumption may be fallible depending on the site, and it is more likely to fail in the lower layers of the atmosphere. This piece of work tests the homogeneity of the wind field over a boundary layer wind profiler radar located in complex terrain on the coast under different meteorological conditions. The results reveal the qualitative importance of being aware of deviations in this homogeneity assumption and evaluate its effect on the final product. Patterns of behavior in data have been identified in order to simplify the analysis of the complex signal registered. The quality information obtained from the homogeneity study under different meteorological conditions provides useful indicators for the best alternatives the system can offer to build wind profiles. Finally, the results are also to be considered in order to integrate them in a quality algorithm implemented at the product level.
Resumo:
This study investigated the generation of dissolved free amino acids (DFAA) by the bacterivorous flagellate Rhynchomonas nasuta when feeding on abundant prey. Specifically, it examined whether this flagellate protist exhibits a chemosensory response towards those amino acids. The concentrations of glycine and the and D-enantiomers of glutamate, serine, threonine, alanine, and leucine were determined in co-cultures of the flagellate and bacteria. Glycine, L- and D-alanine, and L-serine were found to accumulate under these conditions in amounts that correlated positively with flagellate abundance, suggesting that protists are involved in their generation. Investigations of the chemotactic response of young and old foraging protists to the same amino acids, offered in concentrations similar to those previously generated, showed that glycine elicited the strongest attraction in both age groups. Young protists were strongly attracted to all the assayed amino acids, whereas older protists maintained a high level of attraction only for glycine. These results suggest that glycine generated by protists actively grazing in bacterially enriched patches functions as an infochemical, signaling to foraging protists the presence of available prey in the aquatic environment.
Resumo:
Although many optical fibre applications are based on their capacity to transmit optical signals with low losses, it can also be desirable for the optical fibre to be strongly affected by a certain physical parameter in the environment. In this way, it can be used as a sensor for this parameter. There are many strong arguments for the use of POFs as sensors. In addition to being easy to handle and low cost, they demonstrate advantages common to all multimode optical fibres. These specifically include flexibility, small size, good electromagnetic compatibility behaviour, and in general, the possibility of measuring any phenomenon without physically interacting with it. In this paper, a sensor based on POF is designed and analysed with the aim of measuring the volume and turbidity of a low viscosity fluid, in this case water, as it passes through a pipe. A comparative study with a commercial sensor is provided to validate the proven flow measurement. Likewise, turbidity is measured using different colour dyes. Finally, this paper will present the most significant results and conclusions from all the tests which are carried out.
Resumo:
A novel self-referencing fiber optic intensity sensor based on bending losses of a partially polished polymer optical fiber (POF) coupler is presented. The coupling ratio (K) depends on the external liquid in which the sensor is immersed. It is possible to distinguish between different liquids and to detect their presence. Experimental results for the most usual liquids found in industry, like water and oil, are given. K value increases up to 10% from the nominal value depending on the liquid. Sensor temperature dependence has also been studied for a range from 25 degrees C (environmental condition) to 50 degrees C. Any sector requiring liquid level measurements in flammable atmospheres can benefit from this intrinsically safe technology.
Resumo:
521 p.
Resumo:
96 p. : il.
Resumo:
Android gailu eramangarrietan erabiltzeko Babelium Project-en prototipoa.