942 resultados para Quadrat sampling
Resumo:
BACKGROUND & AIMS: Trace elements (TE) are involved in the immune and antioxidant defences which are of particular importance during critical illness. Determining plasma TE levels is costly. The present quality control study aimed at assessing the economic impact of a computer reminded blood sampling versus a risk guided on-demand monitoring of plasma concentrations of selenium, copper, and zinc. METHODS: Retrospective analysis of 2 cohorts of patients admitted during 6 months periods in 2006 and 2009 to the ICU of a University hospital. INCLUSION CRITERIA: to receive intravenous micronutrient supplements and/or to have a TE sampling during ICU stay. The TE samplings were triggered by computerized reminder in 2006 versus guided by nutritionists in 2009. RESULTS: During the 2 periods 636 patients met the inclusion criteria out of 2406 consecutive admissions, representing 29.7% and 24.9% respectively of the periods' admissions. The 2009 patients had higher SAPS2 scores (p = 0.02) and lower BMI compared to 2006 (p = 0.007). The number of laboratory determinations was drastically reduced in 2009, particularly during the first week, despite the higher severity of the cohort, resulting in à 55% cost reduction. CONCLUSIONS: The monitoring of TE concentrations guided by a nutritionist resulted in a reduction of the sampling frequency, and targeting on the sickest high risk patients, requiring a nutritional prescription adaptation. This control leads to cost reduction compared to an automated sampling prescription.
Resumo:
Given their central role in mercury (Hg) excretion and suitability as reservoirs, bird feathers are useful Hg biomonitors. Nevertheless, the interpretation of Hg concentrations is still questioned as a result of a poor knowledge of feather physiology and mechanisms affecting Hg deposition. Given the constraints of feather availability to ecotoxicological studies, we tested the effect of intra-individual differences in Hg concentrations according to feather type (body vs. flight feathers), position in the wing and size (mass and length) in order to understand how these factors could affect Hg estimates. We measured Hg concentration of 154 feathers from 28 un-moulted barn owls (Tyto alba), collected dead on roadsides. Median Hg concentration was 0.45 (0.076-4.5) mg kg(-1) in body feathers, 0.44 (0.040-4.9) mg kg(-1) in primary and 0.60 (0.042-4.7) mg kg(-1) in secondary feathers, and we found a poor effect of feather type on intra-individual Hg levels. We also found a negative effect of wing feather mass on Hg concentration but not of feather length and of its position in the wing. We hypothesize that differences in feather growth rate may be the main driver of between-feather differences in Hg concentrations, which can have implications in the interpretation of Hg concentrations in feathers. Finally, we recommend that, whenever possible, several feathers from the same individual should be analysed. The five innermost primaries have lowest mean deviations to both between-feather and intra-individual mean Hg concentration and thus should be selected under restrictive sampling scenarios.
Resumo:
This study aimed at comparing the efficiency of various sampling materials for the collection and subsequent analysis of organic gunshot residues (OGSR). To the best of our knowledge, it is the first time that sampling devices were investigated in detail for further quantitation of OGSR by LC-MS. Seven sampling materials, namely two "swab"-type and five "stub"-type collection materials, were tested. The investigation started with the development of a simple and robust LC-MS method able to separate and quantify molecules typically found in gunpowders, such as diphenylamine or ethylcentralite. The evaluation of sampling materials was then systematically carried out by first analysing blank extracts of the materials to check for potential interferences and determining matrix effects. Based on these results, the best four materials, namely cotton buds, polyester swabs, a tape from 3M and PTFE were compared in terms of collection efficiency during shooting experiments using a set of 9 mm Luger ammunition. It was found that the tape was capable of recovering the highest amounts of OGSR. As tape-lifting is the technique currently used in routine for inorganic GSR, OGSR analysis might be implemented without modifying IGSR sampling and analysis procedure.
Resumo:
We study the relationship between stable sampling sequences for bandlimited functions in $L^p(\R^n)$ and the Fourier multipliers in $L^p$. In the case that the sequence is a lattice and the spectrum is a fundamental domain for the lattice the connection is complete. In the case of irregular sequences there is still a partial relationship.
Resumo:
In this paper, we present view-dependent information theory quality measures for pixel sampling and scene discretization in flatland. The measures are based on a definition for the mutual information of a line, and have a purely geometrical basis. Several algorithms exploiting them are presented and compare well with an existing one based on depth differences
Resumo:
In this paper we address the problem of extracting representative point samples from polygonal models. The goal of such a sampling algorithm is to find points that are evenly distributed. We propose star-discrepancy as a measure for sampling quality and propose new sampling methods based on global line distributions. We investigate several line generation algorithms including an efficient hardware-based sampling method. Our method contributes to the area of point-based graphics by extracting points that are more evenly distributed than by sampling with current algorithms
Resumo:
The uncertainty of any analytical determination depends on analysis and sampling. Uncertainty arising from sampling is usually not controlled and methods for its evaluation are still little known. Pierre Gy’s sampling theory is currently the most complete theory about samplingwhich also takes the design of the sampling equipment into account. Guides dealing with the practical issues of sampling also exist, published by international organizations such as EURACHEM, IUPAC (International Union of Pure and Applied Chemistry) and ISO (International Organization for Standardization). In this work Gy’s sampling theory was applied to several cases, including the analysis of chromite concentration estimated on SEM (Scanning Electron Microscope) images and estimation of the total uncertainty of a drug dissolution procedure. The results clearly show that Gy’s sampling theory can be utilized in both of the above-mentioned cases and that the uncertainties achieved are reliable. Variographic experiments introduced in Gy’s sampling theory are beneficially applied in analyzing the uncertainty of auto-correlated data sets such as industrial process data and environmental discharges. The periodic behaviour of these kinds of processes can be observed by variographic analysis as well as with fast Fourier transformation and auto-correlation functions. With variographic analysis, the uncertainties are estimated as a function of the sampling interval. This is advantageous when environmental data or process data are analyzed as it can be easily estimated how the sampling interval is affecting the overall uncertainty. If the sampling frequency is too high, unnecessary resources will be used. On the other hand, if a frequency is too low, the uncertainty of the determination may be unacceptably high. Variographic methods can also be utilized to estimate the uncertainty of spectral data produced by modern instruments. Since spectral data are multivariate, methods such as Principal Component Analysis (PCA) are needed when the data are analyzed. Optimization of a sampling plan increases the reliability of the analytical process which might at the end have beneficial effects on the economics of chemical analysis,
Resumo:
Selective papers of the workshop on "Development of models and forest soil surveys for monitoring of soil carbon", Koli, Finland, April 5-9 2006.