931 resultados para Point of zero net proton charge
Resumo:
Mode of access: Internet.
Resumo:
We present a new model for the continuous measurement of a coupled quantum dot charge qubit. We model the effects of a realistic measurement, namely adding noise to, and filtering, the current through the detector. This is achieved by embedding the detector in an equivalent circuit for measurement. Our aim is to describe the evolution of the qubit state conditioned on the macroscopic output of the external circuit. We achieve this by generalizing a recently developed quantum trajectory theory for realistic photodetectors [P. Warszawski, H. M. Wiseman, and H. Mabuchi, Phys. Rev. A 65, 023802 (2002)] to treat solid-state detectors. This yields stochastic equations whose (numerical) solutions are the realistic quantum trajectories of the conditioned qubit state. We derive our general theory in the context of a low transparency quantum point contact. Areas of application for our theory and its relation to previous work are discussed.
Resumo:
The turning point of the refractive index (RI) sensitivity based on the multimode microfiber (MMMF) in-line Mach–Zehnder interferometer (MZI) is observed. By tracking the resonant wavelength shift of the MZI generated between the HE11 and HE12 modes in the MMMF, the surrounding RI (SRI) could be detected. Theoretical analysis demonstrates that the RI sensitivity will reach ±∞ on either side of the turning point due to the group effective RI difference (퐺) approaching zero. Significantly, the positive sensitivity exists in a very wide fiber diameter range, while the negative sensitivity can be achieved in a narrow diameter range of only 0.3 μm. Meanwhile, the experimental sensitivities and variation trend at different diameters exhibit high consistency with the theoretical results. High RI sensitivity of 10777.8 nm/RIU (RI unit) at the fiber diameter of 4.6 μm and the RI around 1.3334 is realized. The discovery of the sensitivity turning points has great significance on trace detection due to the possibility of ultrahigh RI sensitivity.
Resumo:
∗ Supported by D.G.I.C.Y.T. Project No. PB93-1142
Resumo:
High breakdown point estimators LME(k) and LT E(k) for location and scale are obtained for symmetrical exponentially decreasing density family.
Resumo:
Aims: Measurement of glycated hemoglobin (HbA1c) is an important indicator of glucose control over time. Point-of-care (POC) devices allow for rapid and convenient measurement of HbA1c, greatly facilitating diabetes care. We assessed two POC analyzers in the Peruvian Amazon where laboratory-based HbA1c testing is not available.
Methods: Venous blood samples were collected from 203 individuals from six different Amazonian communities with a wide range of HbA1c, 4.4-9.0% (25-75 mmol/mol). The results of the Afinion AS100 and the DCA Vantage POC analyzers were compared to a central laboratory using the Premier Hb9210 high-performance liquid chromatography (HPLC) method. Imprecision was assessed by performing 14 successive tests of a single blood sample.
Results: The correlation coefficient r for POC and HPLC results was 0.92 for the Afinion and 0.93 for the DCA Vantage. The Afinion generated higher HbA1c results than the HPLC (mean difference = +0.56% [+6 mmol/mol]; p < 0.001), as did the DCA Vantage (mean difference = +0.32% [4 mmol/mol]). The bias observed between POC and HPLC did not vary by HbA1c level for the DCA Vantage (p = 0.190), but it did for the Afinion (p < 0.001). Imprecision results were: CV = 1.75% for the Afinion, CV = 4.01% for the DCA Vantage. Sensitivity was 100% for both devices, specificity was 48.3% for the Afinion and 85.1% for the DCA Vantage, positive predictive value (PPV) was 14.4% for the Afinion and 34.9% for the DCA Vantage, and negative predictive value (NPV) for both devices was 100%. The area under the receiver operating characteristic (ROC) curve was 0.966 for the Afinion and 0.982 for the DCA Vantage. Agreement between HPLC and POC in classifying diabetes and prediabetes status was slight for the Afinion (Kappa = 0.12) and significantly different (McNemar’s statistic = 89; p < 0.001), and moderate for the DCA Vantage (Kappa = 0.45) and significantly different (McNemar’s statistic = 28; p < 0.001).
Conclusions: Despite significant variation of HbA1c results between the Afinion and DCA Vantage analyzers compared to HPLC, we conclude that both analyzers should be considered in health clinics in the Peruvian Amazon for therapeutic adjustments if healthcare workers are aware of the differences relative to testing in a clinical laboratory. However, imprecision and bias were not low enough to recommend either device for screening purposes, and the local prevalence of anemia and malaria may interfere with diagnostic determinations for a substantial portion of the population.
Resumo:
Control of the collective response of plasma particles to intense laser light is intrinsic to relativistic optics, the development of compact laser-driven particle and radiation sources, as well as investigations of some laboratory astrophysics phenomena. We recently demonstrated that a relativistic plasma aperture produced in an ultra-thin foil at the focus of intense laser radiation can induce diffraction, enabling polarization-based control of the collective motion of plasma electrons. Here we show that under these conditions the electron dynamics are mapped into the beam of protons accelerated via strong charge-separation-induced electrostatic fields. It is demonstrated experimentally and numerically via 3D particle-in-cell simulations that the degree of ellipticity of the laser polarization strongly influences the spatial-intensity distribution of the beam of multi-MeV protons. The influence on both sheath-accelerated and radiation pressure-accelerated protons is investigated. This approach opens up a potential new route to control laser-driven ion sources.
Resumo:
The purpose of this paper is to use the framework of Lie algebroids to study optimal control problems for affine connection control systems (ACCSs) on Lie groups. In this context, the equations for critical trajectories of the problem are geometrically characterized as a Hamiltonian vector field.
Resumo:
Deficits in social communication and interaction have been identified as distinguishing impairments for individuals with an autism spectrum disorder (ASD). As a pivotal skill, the successful development of social communication and interaction in individuals with ASD is a lifelong objective. Point-of-view video modeling has the potential to address these deficits. This type of video involves filming the completion of a targeted skill or behavior from a first-person perspective. By presenting only what a person might see from his or her viewpoint, it has been identified to be more effective in limiting irrelevant stimuli by providing a clear frame of reference to facilitate imitation. The current study investigated the use of point-of-view video modeling in teaching social initiations (e.g., greetings). Using a multiple baseline across participants design, five kindergarten participants were taught social initiations using point-of-view video modeling and video priming. Immediately before and after viewing the entire point-of-view video model, the participants were evaluated on their social initiations with a trained, typically developing peer serving as a communication partner. Specifically, the social initiations involved participants’ abilities to shift their attention toward the peer who entered the classroom, maintain attention toward the peer, and engage in an appropriate social initiation (e.g., hi, hello). Both generalization and maintenance were tested. Overall, the data suggest point-of-view video modeling is an effective intervention for increasing social initiations in young students with ASD. However, retraining was necessary for acquisition of skills in the classroom environment. Generalization in novel environments and with a novel communication partner, and generalization to other social initiation skills was limited. Additionally, maintenance of gained social initiation skills only occurred in the intervention room. Despite the limitations of the study and variable results, there are a number of implications moving forward for both practitioners and future researchers examining point-of-view modeling and its potential impact on the social initiation skills of individuals with ASD.
Resumo:
© 2015. This manuscript version is made available under the CC-BY-NC-ND 4.0 license http://creativecommons.org/licenses/by-nc-nd/4.0/
Resumo:
In this article, the authors propose a theory of the truth value of propositions from a logic-mathematical point of view. The work that the authors present is an attempt to address this question from an epistemological, linguistic, and logical-mathematical point of view. What is it to exist and how do we define existence? The main objective of this work is an approach to the first of these questions. We leave a more thorough treatment of the problem of existence for future works.
Resumo:
The epoc® blood analysis system (Epocal Inc., Ottawa, Ontario, Canada) is a newly developed in vitro diagnostic hand-held analyzer for testing whole blood samples at point-of-care, which provides blood gas, electrolytes, ionized calcium, glucose, lactate, and hematocrit/calculated hemoglobin rapidly. The analytical performance of the epoc® system was evaluated in a tertiary hospital, see related research article “Analytical evaluation of the epoc® point-of-care blood analysis system in cardiopulmonary bypass patients” [1]. Data presented are the linearity analysis for 9 parameters and the comparison study in 40 cardiopulmonary bypass patients on 3 epoc® meters, Instrumentation Laboratory GEM4000, Abbott iSTAT, Nova CCX, and Roche Accu-Chek Inform II and Performa glucose meters.
Resumo:
O objectivo principal deste trabalho de mestrado consistiu em avaliar a potencial utilização de materiais adsorventes, nomeadamente, de carvões activados (AC) preparados por activação química com KOH, a partir de PET reciclado, e de materiais com estrutura mesoporosa ordenada, do tipo MCM-41 e SBA-15, na remoção de ácido 4 - cloro - 2 - metilfenoxiacético (MCPA) e de azul de metileno (MB), presentes nas águas. Nesta tese apresentam-se estudos de preparação e caracterização de materiais micro e mesoporosos e também estudos de avaliação da capacidade adsortiva em fase líquida. Prepararam-se três materiais microporosos, nomeadamente, PET-2-700, PET-2-700ox (AC oxidado) e PET-2-700red (AC reduzido), dois materiais constituídos exclusivamente por mesoporos, Si-MCM-41 e Ti-MCM-41-50 e dois materiais contendo maioritariamente mesoporos, mas que também possuem alguma microporosidade, tais corno, Si-SBA-15 e Ti-SBA-15-50. A caracterização textural dos adsorventes foi inferida por adsorção de azoto a 77K e por de difracção de raios X. Recorreu-se a três métodos de análise das isotérmicas, nomeadamente, Dubinin-Radushkevich, Brunauer-Ernrnett-Teller e alfa-s (as). A caracterização química dos AC foi realizada recorrendo-se a técnicas de análise elementar (AE) e espectroscopia de infravermelho com transformadas de Fourier (FTIR) e à determinação do ponto de carga zero. Os três carvões activados possuem valores de área superficial externa idênticos, o PET-2-700 possui o maior volume microporoso e o PET-2-700ox exibe o maior diâmetro de poros. Por outro lado, o PET-2-700ox possui um carácter fortemente ácido, o PET-2-700 exibe carácter ligeiramente ácido e o PET-2-700red apresenta propriedades ligeiramente alcalinas. Com base na AE, todas as amostras possuem percentagens de carbono elevadas, sendo que o PET-2-700red apresenta o valor mais elevado. Os resultados obtidos para a caracterização estrutural dos revelaram a obtenção de materiais mesoporosos de alta qualidade, definida pela elevada regularidade e uniformidade da estrutura porosa. A análise dos parâmetros de caracterização textura! permitiu inferir que os quatro materiais mesoporosos possuem valores de área superficial elevados, e que os materiais SBA-15 apresentam valores de volume poroso total e de tamanho de poros superiores aos manifestados pelos MCM-41. A incorporação de titânio não conduziu a uma perda significativa de qualidade dos materiais substituídos em relação às correspondentes amostras de sílica. Efectuaram-se estudos de adsorção em fase líquida de forma a avaliar a possível aplicação dos vários adsorventes na remoção de MCPA e de MB de efluentes líquidos. concluiu-se que o tempo de equilíbrio de 72 horas seria adequado e que a capacidade de adsorção dos vários AC era superior em meio ácido. Com base nas isotérmicas de adsorção do MCPA e do MB e na aplicação da representação de Langmuir e de Freundlich, foi possível concluir que o PET-2-700 possui a maior capacidade de adsorção do MCPA, 1.42 mmol/g, enquanto que o PET-2-700ox revelou a maior capacidade de adsorção do MB, 1.43 mmol/g. Na realidade, os materiais microporosos estudados apresentaram percentagens de remoção elevadas, tanto do MCPA como do MB. Relativamente aos materiais mesoporosos ordenados preparados neste trabalho, a percentagem de remoção de para os poluentes em estudo foi relativamente baixa, constatando-se que nesta fase dos estudos não constituem uma alternativa viável à utilização dos AC. No entanto, uma funcionalização criteriosa dos mesmos pode eventualmente proporcionar um aumento da capacidade adsortiva. ABSTRACT: The work presented in this master thesis, consisted of evaluating the potential use of different adsorbents materials, like activated carbon (AC) prepared by chemical activation with KOH, from recycled poly (ethylene terephthalate) (PET) and materials with ordered mesoporous structure such as MCM-41 and SBA-15, for removing acid 4-chlorine-2-metilfenoxiacétic and methylene blue from aqueous phase. We had prepared three microporous materials, PET-200-700, PET-2-700ox (AC oxidized) and PET-2-700red (reduced AC), two materials consisting exclusively of mesopores, Si-MCM-41 and Ti-MCM-41-50 and two materials containing mainly mesopores, but also having some microporosity, such as Si-SBA-15 and Ti-SBA-15-50. The textural characterization of the adsorbents was inferred by nitrogen adsorption at 77K and X-ray diffraction. Three methods were used to analyse the isotherms, namely, Dubinin-Radushkevich, Brunauer-Emmett-Teller and alpha-s (as). The chemical characterization of AC was performed using the elementary analysis, Fourier transform infrared spectroscopy (FTIR) and determination of the point of zero charge. Concerning the AC, the three present almost the same externa! surface area, PET-2-700 has a high micropore volume and PET-2-700ox shows the largest pore size diameter. On the other hand, PET-2-700ox had a strong acid character, PET-2-700 exhibits just a slightly acid character and PET-2-700red presents alkaline properties. The AE analysis allows confirming the high carbon content of theses AC, with PET-2-700red exhibiting the highest carbon proportion. The results from the structural characterization of the mesoporous materials, had disclosed the attainment of materials with high quality, defined by the raised regularity and uniformity of the porous structure. The analysis of the textural parameters allowed inferring that the four studied mesoporous materials possess high superficial area. The SBA-15 type materials present higher values of total porous volume and pores size diameter as the MCM-41. Also, the titanium incorporation did not lead to a significant loss of quality of the materials substituted in relation to the corresponding silica samples. The adsorption studies in liquid phase allow evaluating the possibility of using the different adsorbents for the MCPA and the MB removal. The kinetic studies had allowed to state the equilibrium time as 72 hours and a higher adsorption capacity was achieved in an acid medium. The influence of the pH of the medium, on the MCPA adsorption was evaluated. The MCPA and MB isotherms were analysed based on the Langmuir and Freundlich equation, the representations presented an excellent linearity, indicating the applicability of these equations to these systems. Also, it allows concluded that PET-2-700 had a higher adsorption capacity for MCPA, 1.42 mmol/g, and PET-2-700ox had a higher adsorption capacity for MB, 1.43 mmol/g. The AC used presented high removal percentages for MCPA and MB. Concerning the mesoporous materials prepared in this work, the percentage removal for the pollutants in study was relatively low, and evidencing that at the moment these mesoporous materials do not constitute a viable alternative to the AC. However, an astute funcionalisation of the same ones can, eventually provide an increase of the adsorption capacity.