992 resultados para Oxygen-saturation
Resumo:
Study Objectives: Metabolic syndrome (MetSyn) increases overall cardiovascular risk. MetSyn is also strongly associated with obstructive sleep apnea (OSA), and these 2 conditions share similar comorbidities. Whether OSA increases cardiovascular risk in patients with the MetSyn has not been investigated. We examined how the presence of USA in patients with MetSyn affected hemodynamic and autonomic variables associated with poor cardiovascular outcome. Design: Prospective clinical study. Participants: We studied 36 patients with MetSyn (ATP-III) divided into 2 groups matched for age and sex: (1) MetSyn+OSA (n = 18) and (2) MetSyn-OSA (n = 18). Measurements: USA was defined by an apnea-hypopnea index (AHI) > 15 events/hour by polysomnography. We recorded muscle sympathetic nerve activity (MSNA - microneurography), heart rate (HR), and blood pressure (BP - Finapres). Baroreflex sensitivity (BRS) was analyzed by spontaneous BP and HR fluctuations. Results: MSNA (34 +/- 2 vs 28 +/- 1 bursts/min, P = 0.02) and mean BP (111 +/- 3 vs. 99 +/- 2 mm Hg, P = 0.003) were higher in patients with MetSyn+OSA versus patients with MetSyn-USA. Patients with MetSyn+OSA had lower spontaneous BRS for increases (7.6 +/- 0.6 vs 12.2 +/- 1.2 msec/mm Hg, P = 0.003) and decreases (7.2 +/- 0.6 vs 11.9 +/- 1.6 msec/mm Hg, P = 0.01) in BP. MSNA was correlated with AHI (r = 0.48; P = 0.009) and minimum nocturnal oxygen saturation (r = -0.38, P = 0.04). Conclusion: Patients with MetSyn and comorbid USA have higher BP, higher sympathetic drive, and diminished BRS, compared with patients with MetSyn without USA. These adverse cardiovascular and autonomic consequences of USA may be associated with poorer outcomes in these patients. Moreover, increased BP and sympathetic drive in patients with MetSyn+OSA may be linked, in part, to impairment of baroreflex gain.
Resumo:
BACKGROUND Obstructive sleep apnea (OSA) is an established cause of hypertension However, it is not clear whether the frequency of masked hypertension in patients with OSA and whether OSA have an independent role on arterial stiffness taking into account ambulatory blood pressure (BP) monitoring (ABPM) METHODS We evaluated 61 male normotensive participants as determined by casual clinic BP level <140/90 mm Hg without clinical evidence of cardiovascular disease and on no medications (43 patients with moderate-to-severe OSA (apnea-hypopnea index (AHI) >= 15 events/hour by polysomnography) and 18 age- and body mass index-matched controls without OSA (AHl <5 events/hour)) Pulse wave velocity (PWV), an index of arterial stiffness, and 24-h ABPM were performed in a blinded fashion Masked hypertension was defined when abnormal daytime ABPM was >= 135 or >= 85 mm Hg RESULTS The AHI and lowest oxygen saturation were 26 +/- 16 and 90 +/- 2 vs 528 +/- 210 events/hour and 75 +/- 10% for controls and OSA patients, respectively, P < 0 001. Compared with controls, patients with OSA had higher office systolic BP (113 +/- 9 vs 118 +/- 10 mm Hg, P=0 05) and a higher unadjusted proportion of masked hypertension (2 controls (11.1%)vs 13 patients (30 2%), P < 005) PWV was 87 +/- 0.7, 9.4 +/- 1.0, and 10.6 +/- 1.1 m/s in the control, OSA without and with masked hypertension groups, respectively (P < 0 01 for each comparison) Multiple regression showed that systolic daytime ABPM and the lowest oxygen saturation were independently related to PWV (adjusted R(2) = 0 34, P < 0 01) CONCLUSIONS Patients with OSA presented a higher unadjusted rate of masked hypertension than matched controls. Lowest oxygen saturation has an independent association with arterial stiffness
Resumo:
The aim of this study was to evaluate the efficacy of a cost-effective intra-oral appliance for obstructive sleep apnea syndrome built into a large teaching hospital. Out of 20 evaluated and treated patients, 14 concluded the study: eight men and six women, with a mean age of 42-46 (mean + SD) years and mean body mass index of 27.66. Inclusion criteria were mild or moderate apnea-hypopnea index (AHI) according to a polysomnographic study. All patients were treated with the monobloco intra-oral appliance. They were then submitted to a follow-up polysomnographic study after 60 days using the appliance. An orofacial clinical evaluation was carried out with the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) questionnaire and with clinical evaluation questionnaire devised by the Orofacial Pain Team before and 60 days after fitting the intra-oral appliance. The AHI showed a statistically meaningful (p = 0.002) reduction from 15.53 to 7.82 events per hour, a non-statistically significant oxygen saturation increase from 83.36 to 84.86 (p = 0.09), and Epworth`s sleepiness scale reduction from 9.14 to 6.36 (p = 0.001). Three patients did not show any improvement. The most common side effect during the use of the appliance/device was pain and facial discomfort (28.57%), without myofascial or temporomandibular joint pain as evaluated by the RDC/TMD questionnaire. The intra-oral device produced a significant reduction of the apnea-hypopnea index during the study period with the use of the monobloco intra-oral appliance. Patients did not show prior myofascial pain or 60 days after use of the intra-oral appliance.
Resumo:
Objectives/Hypothesis: Polysomnography (PSG) is the gold-standard method for diagnosing obstructive sleep apnea (OSA). However, the gap between demand and capacity in performing PSG is a major health-care problem. We sought to validate a short day-time induced sleep for the diagnosis of OSA. Study Design: Prospective diagnostic method validation. Methods: We studied 25 consecutive patients referred to the sleep laboratory and 15 healthy volunteers. All subjects were evaluated by means of full overnight PSG (Full-PSG) and short day-time induced-sleep PSG (Induced-PSG). Sleep was monitored during both procedures (Embla, 16 channels). Sleep was induced by slow intravenous drip infusion of midazolam. Results: The population studied (N = 40) was 60% male (mean age, 42 +/- 10 years; body mass index, 29 +/- 6.5 kg/m(2)). Sleep was successfully induced in all subjects, and no complications were observed (midazolam doses, 6.2 +/- 3.8 mg; time of induced sleep 41.5 +/- 18.9 minutes). The apnea-hypopnea index (AHI) and minimal oxygen saturation during Full-PSG versus Induced-PSG were similar: median AHI (with 25%-75% interquartile range) was 13 (3-35) events per hour versus 17 (4-36) events per hour, and median oxygen saturation was 84% (75-90) versus 85% (76-92); P = .89 and P = .53, respectively. The majority of the respiratory events during induced sleep were obstructive and similar to those observed during Full-PSG. AHI and lowest oxygen saturation during Induced-PSG correlated significantly with Full-PSG (r = 0.67 and r = 0.77, respectively). Sensitivity and specificity for the diagnosis of OSA (AHI > 15 events per hour) by Induced-PSG were 0.83 and 0.72, respectively. Conclusions: Induced-PSG by midazolam during the day is safe and correlates with Full-PSG; it therefore is a promising alternative method in the diagnosis of OSA.
Resumo:
The objectives of this study were to check music and voice message influence on vital signs and facial expressions of patients with disorders of consciousness and to connect the existence of patient`s responses with the Glasgow Coma Scale or with the Ramsay Sedation Scale. The method was a single-blinded randomized controlled clinical trial with 30 patients, from two intensive care units, being divided into two groups (control and experimental). Their relatives recorded a voice message and chose a song according to the patient`s preference. The patients were submitted to three sessions for three consecutive days. Significant statistical alterations of the vital signs were noted during the message playback (oxygen saturation-Day 1 and Day 3; respiratory frequency-Day 3) and with facial expression, on Day 1, during both music and message. The conclusion was that the voice message was a stronger stimulus than the music.
Resumo:
Purpose: To compare the level of sedation of oral administration of diazepam or midazolam associated or not with clonidine and their effects on upper eyelid margin position, heart rate, arterial pressure, and oxygen saturation. Methods: Seventy consecutive healthy patients American Society of Anesthesiologists (ASA) grade I-II scheduled for lower eyelid blepharoplasty were randomized into 4 groups according to the oral sedative agent used (group 1, diazepam 10 mg; group 2, diazepam 10 mg plus clonidine 0.15 mg; group 3, midazolam 15 mg; group 4, midazolam plus clonidine 0.15 mg). For all patients, the midpupil-to-upper eyelid margin distance, the heart rate, systolic and diastolic blood pressure, and oxygen saturation were recorded before and 1 hour after the administration of oral medication. The level of sedation at the time of surgery was measured with the Michigan University scale. Results: The depth of sedation was significantly more pronounced with midazolam (median score = 2) than with diazepam (median score = 1). Clonidine slightly increased the level of sedation of both diazepam and midazolam. The diastolic arterial blood pressure drop with midazolam associated or not with clonidine was significantly greater than with diazepam. The mean upper eyelid margin position shift (-1.42 mm) verified when clonidine was associated with midazolam was also significantly greater than with diazepam. Discussion: Oral sedation with diazepam or midazolam associated or not with clonidine is safe for ASA grade I-II patients. The systemic effects of diazepam and midazolam were small and very similar. The sedation induced by midazolam was clearly greater than that induced by diazepam. However, this higher level of sedation was accompanied by a more important shift in upper eyelid margin position.
Resumo:
Aim To evaluate the use of pulse oximetry as a test for pulp vitality, by comparing in the same patient, the levels of oxygen saturation of the index finger and of the maxillary central incisor and canine teeth without clinically detectable pulp inflammation. Methodology Seventeen male and female patients aged between 26 and 38 years participated and a total of 32 maxillary central incisor and 32 canine teeth were analysed. Selection criteria required the teeth to have healthy crowns, or with restorations no more than 2 mm in diameter and no clinical and radiographical signs or symptoms of pulp or periapical inflammatory changes. The negative control group consisted of 10 root filled teeth. Measurements were first taken from the index finger of patients. Their teeth were then subjected to a thermal test with refrigerant gas and then to a vitality test with pulse oximetry. Data were analysed by Pearson`s and paired t-tests. Results There were no significant statistical correlations between blood oxygen levels in the index finger and in the teeth of the patient (P > 0.05). There was a statistically significant difference in the oxygen levels between the two tooth groups studied and the index finger (P <= 0.002). Mean oxygen values in the index finger of patients were 95% (SD = 1.6), oxygen values in the maxillary central incisor were 91.29% (SD = 2.61) and mean oxygen values in maxillary canine were 90.69% (SD = 2.71). Conclusion The method determined consistently the level of blood oxygen saturation of the pulp in maxillary central incisor and canine teeth and can therefore be used for pulp vitality testing. Further studies are required to assess the effectiveness and validity of pulse oximetry in determining pulp vitality in traumatized teeth.
Resumo:
This article examines the current status of fetal pulse oximetry (FPO) as a means of intrapartum assessment of fetal wellbeing. FPO has been developed to a stage where it is a safe and accurate indicator of intrapartum fetal oxygenation. In general, sliding the FPO sensor along the examiner's fingers and through the cervix, to lie alongside the fetal cheek or temple is easy The recent publication of a randomised controlled trial (RCT) of FPO versus conventional intrapartum monitoring has validated its use to reduce caesarean section rates for nonreassuring fetal status. An Australian multicentre RCT is currently underway. Maternal satisfaction rates with FPO are high. FPO may be used during labour when the electronic fetal heart rate trace is nonreassuring or when conventional monitoring is unreliable, such as with fetal arrhythmias. If the fetal oxygen saturation (FSpO(2)) values are < 30%, prompt obstetric intervention is indicated, such as fetal scalp blood sampling or delivery FSpO(2) monitoring should not form the sole basis of intrapartum fetal welfare assessment. Rather, the whole clinical picture should be considered.
Resumo:
Thirteen intubated, high dependency patients with neurological injuries were studied in order to investigate the short term respiratory effects of neurophysiological facilitation and passive movement on tidal volume (V-T), minute ventilation (V-E), respiratory rate (V-R) and oxygen saturation (SpO(2)). The subjects were studied under four conditions: no intervention (control) and during periods of neurophysiological facilitation, passive movement and sensory stimulation. All periods were standardised to three minutes duration and all parameters were recorded before and after each intervention. Neurophysiological facilitation produced significant increases (p < 0.01) in V-E and SpO(2) (p < 0.05) when compared with control values, with an overall mean increase in V-E of 14.6%. Similarly, passive movement increased V-E (p < 0.01) by an average of 9.8% and also increased SpO(2) (p < 0.01). In contrast, sensory stimulation produced significant increases (p < 0.01) in SpO(2) with control levels, with no significant change in V-T or V-E. There was no significant difference in V-R with all treatments. This study provides preliminary evidence of improved short term ventilatory function following neurophysiological facilitation, independent of generalised sensory stimulation, which has not been previously examined in the literature, supporting its use in the management of high dependency neurological patients.
Resumo:
Contexto: a bronquiolite aguda é a principal patologia a afectar a criança nos primeiros 2 anos de vida, a fisioterapia respiratória é uma intervenção terapêutica utilizada com a intenção de melhorar o curso desta doença mantendo-se a incerteza sobre a sua eficácia. Objectivo: determinar a eficácia e segurança da fisioterapia respiratória em crianças com menos de 2 anos com bronquiolite aguda. Fontes de Informação: Medline (1966 a Agosto 2010), EMBASE(1990 a Agosto 2010), Pedro e Lilacs (1982 a Agosto 2010). Outra fonte de informação incluiu a bibliografia dos estudos obtidos. Selecção de estudos: estudos experimentais comparando a fisioterapia respiratória com cuidados habituais, em crianças com menos de 2 anos e bronquiolite aguda, em ventilação espontânea, em qualquer contexto. Estudos pré-experimentais ou observacionais com os mesmos participantes e intervenções foram admitidos complementarmente aos experimentais. Extracção de dados e análise: um investigador extraiu os dados dos artigos obtidos e avaliou o risco de viés. A eficácia e segurança da fisioterapia respiratória foram determinadas pelos seguintes outcomes: duração do internamento hospitalar ou do evento, variação de scores de severidade clínica, saturação periférica e suplementação de oxigénio, recidivas, recurso a antibióticos e efeitos deletérios ou deterioração clínica reportada. Síntese de dados: 6 estudos experimentais foram admitidos. As suas amostras provinham de criança internadas em hospital. As técnicas de fisioterapia respiratória foram comparadas com cuidados habituais. Nenhum estudo evidenciou melhoria dos outcomes de interesse na comparação entre grupos, excepto avaliações de curta duração da saturação periférica de oxigénio e scores de severidade clínica. 1 estudo reportou uma percentagem significativamente maior no grupo submetido a fisioterapia respiratória de crianças que vomitaram, tiveram uma desestabilização respiratória transitória, e na percepção de stress da criança pelos cuidadores. São relatadas ainda fracturas costais a causa de fisioterapia respiratória. Limitações: o risco de viés era alto em 2 estudos, baixo num estudo e indeterminado nos restantes. Conclusões: aparentemente a fisioterapia respiratória não é eficaz e pode produzir efeitos deletérios importantes, mas a evidência é pobre, carecendo de novos estudos.
Resumo:
Mestrado em Fisioterapia.
Resumo:
Introdução: A cirurgia abdominal acarreta grande risco de complicações pulmonares pós-operatórias. As alterações pós-cirúrgicas abdominais, reflectem-se na dinâmica ventilatória, de modo particular nos volumes e capacidades pulmonares, e na capacidade de tosse. Objectivos: Compreender qual a variação dos volumes e capacidades pulmonares e da capacidade de tosse antes e depois da cirurgia abdominal (estômago e cólon), e qual a correlação dessa variação com o nível de dor percepcionada. Desenho do estudo: Unicêntrico, prospectivo e observacional. Amostra: 10 indivíduos, propostos para cirurgia abdominal – estômago e cólon. Metodologia: Dois momentos de avaliação: um nas 24h préoperatórias em que se mediu a capacidade vital forçada (CVF) e o volume expirado máximo no primeiro segundo (VEMS1) com espirometria, e do pico de fluxo de tosse (PCF); e um segundo momento nas 24h pós-operatórias onde se repetiram as medições do primeiro momento com o acréscimo da avaliação da dor. Resultados: No pós-operatorio imediato há uma diminuição significativa da CVF de 44,30%±17,24 (p=0,005), do VEMS1 de 35,50%±28,47 (p=0,009) e do PCF de 38,97%±38,66 (p=0,012). Não se verificou nenhuma relação entre a dor percepcionada na realização das manobras de espirometria e tosse com diminuição a da CVF e do VEMS1 e do PCF respectivamente. O sexo apresentou uma relação significativa com a variação da CRF e do VEMS1 (p=0,046 e p=0,008 respectivamente). A frequência respiratória apresentou um aumento significativo no pós-operatório de 10±11,22 cpm (p=0,019). A saturação periférica de oxigénio apresentou uma diminuição significativa no pós-operatório de 3,52±2,47 (p=0,011) Conclusão: No estudo efectuado fica demonstrado o impacto negativo da cirurgia abdominal na dinâmica respiratória. A diminuição dos valores da CVF, do VEMS1 e do PCF podem contribuir de forma significativa para o aumento do risco de complicações respiratória pós-operatórias. No entanto seria importante a realização deste estudo com uma amostra maior.
Resumo:
Dissertação de Mestrado, Estudos Integrados dos Oceanos, 25 de Março de 2013, Universidade dos Açores.
Resumo:
O número de bebés que nascem prematuros tem vindo a aumentar. É indiscutível a importância dos avanços tecnológicos e da pesquisa nas Unidades de Cuidados Intensivos de Neonatologia (UCIN), sendo essencial o papel desempenhado pelos fisioterapeutas nos cuidados prestados a estes bebés. As suas potencialidades só se desenvolvem na medida em que o bebé encontra estimulação e posicionamento adequado. Realizou‑se um estudo piloto na UCIN do Centro Hospitalar Lisboa Norte (CHLN), no período de julho de 2011 a março de 2012, em que se pretendeu avaliar o efeito de um programa de fisioterapia na estabilização do prematuro. Este programa consistiu em posicionar o prematuro em decúbito dorsal, lateral direito e lateral esquerdo e decúbito ventral, permanecendo em cada posição 5 minutos. O objetivo foi avaliar, durante a permanência do bebé na UCIN, a alteração nos seguintes parâmetros: frequência cardíaca (FC) e saturação de oxigénio (SatO2), antes e depois do tratamento. A amostra por conveniência incluiu no estudo 30 bebés prematuros, sendo 13 do género feminino e 17 do género masculino, que obedeceram a critérios específicos de inclusão. Para verificar as variáveis fisiológicas FC e SatO2 foi utilizado um Oxímetro de Pulso BCI 3401. Verificou‑se que a FC diminui e a SatO2 aumentou entre a primeira avaliação e a segunda avaliação, para a amostra total, assim como para os sujeitos do género feminino e os sujeitos do género masculino, para α = 0,05 e valor p≤0,001. Contudo, a diferença entre as médias dos dois momentos de avaliação da FC e da SatO2, em função do género, não revelaram diferenças estatisticamente significativas. Em conclusão, o estudo sugere que o programa de fisioterapia promove a melhoria da SatO2 e diminuição da FC, promovendo uma melhoria da estabilização do prematuro.
Resumo:
Introdução: O CPAP nasal é o tratamento de eleição para os pacientes com Síndrome da Apneia Obstrutiva do Sono (SAOS). Com a máscara nasal podem ocorrer fugas de ar pela boca, que podem por em causa a aderência do paciente ao tratamento devido muitas vezes ao desconforto que provocam, ao aumento do trabalho respiratório e por afectarem a qualidade do sono. Objectivos: Este estudo tem como principal objectivo verificar a eficácia da banda submentoniana e da máscara facial na correcção das fugas pela boca em pacientes com SAOS. Métodos e Participantes: Uma amostra de conveniência de 15 pacientes (8 homens) com SAOS e a fazerem CPAP com máscara nasal, foi recrutada. Foram divididos em dois grupos A e B, onde no grupo A se colocou a banda submentoniana e no grupo B se alterou a interface para máscara facial. Medidas e Resultados: As variáveis avaliadas neste estudo foram as fugas, o IAH, o percentil 95 da pressão de tratamento, a Sa,O2 e os efeitos adversos das duas intervenções. O nível de fugas reduziu no grupo A de 38±11,27 para 24,55±14,30L/min (p=0,002) e no grupo B de 34,34±16,50 para 18,51±16,22L/min (p=0,008). O IAH aumentou no grupo B de 2,60±2,13 para 4,41±3,88 (p=0,016). Relativamente ao percentil 95 da pressão de tratamento aumentou nos dois grupos (Grupo A de 10,15±2,63 para 12,08±2,45cmH2O (p=0,008) e no Grupo B 10,51±1,88 para 12,64±1,29cmH2O (p=0,008)). A Sa,O2 mínima aumentou e o tempo<90% diminui no grupo A com p=0,008, p=0,031, respectivamente. Quanto ao uso auto-reportado verificaram-se poucos efeitos adversos, salientando-se apenas a facilidade de colocação da banda submentoniana, a secura da boca nos dois grupos, a pressão no queixo provocada pela banda e a dor no dorso do nariz provocada pela máscara facial. Conclusão: Ambas as estratégias provaram ser mais eficazes a reduzir a fuga que a máscara nasal. Foram bem toleradas e com poucos efeitos adversos.