956 resultados para Low sperm quality


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cryopreservation of sperm is important to preserve the gerrnplasm from animals of genetic value, which can die unexpectedly. This study compares conventional and automated methods of cryopreservation of spermatozoa obtained from the epididymis of bulls post-mortem. Twenty-two epididymides were obtained from a commercial slaughterhouse. Spermatozoa were collected from the tail of the epididymis using the retrograde flow technique. Thus, the samples, which were diluted in 10 ml of extender without glycerol (Botubov (R) I, Botupharma, Botucatu, SP, Brazil), were evaluated on motility, sperm vigor, structural and functional (swelling hypoosmotic test) membrane integrity, mitochondrial activity, sperm viability and ADN fragmentation. The samples were divided into two aliquots and diluted in extender with glycerol (Botubov (R) II, Botupharma, Botucatu, SP, Brazil) at a concentration of 50x10(6) motile sperm/0.5 French straws. One sample was frozen by the conventional method (4 hours at 5 degrees C, in a refrigerator and 20 min in nitrogen vapor) and the other by the automated method (Cryogen (R) Dualflex, Neovet, Uberaba, MG, Brazil). The parameters were higher in all the tests of fresh sperm samples, with the exception of the swelling hypoosmotic test, which showed no significant difference when the results were compared with sperm frozen by the conventional method. The average motility of fresh spermatozoa was 74%, and conventional and automated averages were 29 and 25%, respectively. Therefore, although cryopreservation techniques reduce sperm quality parameters, the viability of the sperm is maintained, and these methods can be used to preserve sperm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A discussion concerning marine eutrophication, possible generated from an imbalance of fish population is presented. Simulations through a code in FORCE 2.0 considering a predator-prey model have been made and the numerical results for a three different fish species were plot in ORIGIN code. The populations considered in this study were: Sardines being prey and both mackerel and tuna being the sardine’s predators. Some hipotheses concerning to the marine eutrophication have being made according to the stages of the dynamics of the system. For situations were the prey’s populationis very low, the quality of the water experiences a strong depreciation leading to a possible eutrophication of the water.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The penis and prepuce of the stallion have a high bacterial load on its surface, forming a natural microbial flora that contaminates the semen during ejaculation. Bacterial growth in semen may cause a decline on sperm quality, viability, and fertility and predisposes the occurrence of endometritis in inseminated mares. Thus, the aim of this study was to evaluate the effect of penile wash before semen collection, the addition of different commercial skim milk-based extenders containing antibiotics (BotuSemen and INRA96), and the removal of seminal plasma by filtration on the quality, viability, and bacterial proliferation on fresh and cooled stallion semen. Animals that were never submitted to penile wash before semen collection tended to have lower bacterial contamination in the ejaculate. Semen samples extended in BotuSemen showed superiority in total motility, progressive motility, average path velocity, and rapid sperm and lower bacterial contamination in relation to semen samples extended in INRA96 after 24 hours of cooling. No difference was found in these parameters between the storage temperatures (5 degrees C and 15 degrees C). Furthermore, the removal of seminal plasma by filtration reduced the bacterial load in semen after cooling. In conclusion, the penile wash before semen collection tended to reduce the bacterial growth in fresh semen. The use of a semen extender with appropriate antibiotics and removal of seminal plasma by filtration were effective in reducing the bacterial contamination and preserved the quality of cooled stallion semen. (C) 2015 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Interferon-alpha (IFN- α ), a type I IFN, is a protein with antiviral, antiproliferative, and immunoregulatory activities, widely used in the treatment of several types of cancers as well as hepatitis B and C. Decrease of libido and erectile dysfunction are commonly reported by male patients during treatment of chronic hepatitis C with IFN- α . However, IFN therapy-associated underlying factors attributed to sexual dysfunction are still not well defined. Currently, there are few studies investigating the effects of IFN on male reproductive system functions. Given that, the aim of the present investigation was to examine effects of subchronic exposure to IFN- α (5 × 10(4) U/kg and 10 × 10(4) U/kg, 30 d) on serum hormones, sperm parameters, fertility, and testicular and epididymal hystopathology and morphometry in adult male Wistar rats. None of the evaluated parameters was markedly altered by IFN- α . Thus, our results suggest that exposure to IFN- α , in this experimental design, did not adversely affect sperm quality and fertile capacity of male rats.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Cryopreservation of sperm is important to preserve the germplasm from animals of genetic value, which can die unexpectedly. This study compares conventional and automated methods of cryopreservation of spermatozoa obtained from the epididymis of bulls post-mortem. Twenty-two epididymides were obtained from a commercial slaughterhouse. Spermatozoa were collected from the tail of the epididymis using the retrograde flow technique. Thus, the samples, which were diluted in 10 ml of extender without glycerol (Botubov® I, Botupharma, Botucatu, SP, Brazil), were evaluated on motility, sperm vigor, structural and functional (swelling hypoosmotic test) membrane integrity, mitochondrial activity, sperm viability and ADN fragmentation. The samples were divided into two aliquots and diluted in extender with glycerol (Botubov® II, Botupharma, Botucatu, SP, Brazil) at a concentration of 50x106 motile sperm/0.5 French straws. One sample was frozen by the conventional method (4 hours at 5°C, in a refrigerator and 20 min in nitrogen vapor) and the other by the automated method (Cryogen® Dualflex, Neovet, Uberaba, MG, Brazil). The parameters were higher in all the tests of fresh sperm samples, with the exception of the swelling hypoosmotic test, which showed no significant difference when the results were compared with sperm frozen by the conventional method. The average motility of fresh spermatozoa was 74%, and conventional and automated averages were 29 and 25%, respectively. Therefore, although cryopreservation techniques reduce sperm quality parameters, the viability of the sperm is maintained, and these methods can be used to preserve sperm.