777 resultados para Intraocular lenses
Resumo:
Purpose To evaluate the influence of cone location and corneal cylinder on RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Methods In this prospective study, 156 eyes from 134 patients were enrolled. Complete ophthalmologic examination including manifest refraction, Best spectacle visual acuity (BSCVA), slit-lamp biomicroscopy was performed and corneal topography analysis was done. According to the cone location on the topographic map, the patients were divided into central and paracentral cone groups. Trial RGP lenses were selected based on the flat Sim K readings and a ‘three-point touch’ fitting approach was used. Over contact lens refraction was performed, residual astigmatism (RA) was measured and best-corrected RGP visual acuities (RGPVA) were recorded. Results The mean age (±SD) was 22.1 ± 5.3 years. 76 eyes (48.6%) had central and 80 eyes (51.4%) had paracentral cone. Prior to RGP lenses fitting mean (±SD) subjective refraction spherical equivalent (SRSE), subjective refraction astigmatism (SRAST) and BSCVA (logMAR) were −5.04 ± 2.27 D, −3.51 ± 1.68 D and 0.34 ± 0.14, respectively. There were statistically significant differences between central and paracentral cone groups in mean values of SRSE, SRAST, flat meridian (Sim K1), steep meridian (Sim K2), mean K and corneal cylinder (p-values < 0.05). Comparison of BSCVA to RGPVA shows that vision has improved 0.3 logMAR by RGP lenses (p < 0.0001). Mean (±SD) RA was −0.72 ± 0.39 D. There were no statistically significant differences between RGPVAs and RAs of central and paracentral cone groups (p = 0.22) and (p = 0.42), respectively. Pearson's correlation analysis shows that there is a statistically significant relationship between corneal cylinder and BSCVA and RGPVA, However, the relationship between corneal cylinder and residual astigmatism was not significant. Conclusions Cone location has no effect on the RGP corrected visual acuities and residual astigmatism in patients with keratoconus. Corneal cylinder and Sim K values influence RGP-corrected visual acuities but do not influence residual astigmatism.
Resumo:
We sought to evaluate central corneal thickness (CCT), corneal endothelial cell density (ECD) and intraocular pressure (IOP) in patients with type 2 diabetes mellitus (DM) and to associate potential differences with diabetes duration and treatment modality in a prospective, randomized study. We measured ECD, CCT and IOP of 125 patients with type 2 DM (mean age 57.1¡11.5 years) and compared them with 90 age-matched controls. Measured parameters were analyzed for association with diabetes duration and glucose control modalities (insulin injection or oral medication) while controlling for age. In the diabetic group, the mean ECD (2511¡252 cells/mm2), mean CCT (539.7¡33.6 mm) and mean IOP (18.3¡2.5 mmHg) varied significantly from those the control group [ECD: 2713¡132 cells/mm2 (P,0.0001), CCT: 525.0¡45.3 mm (P50.003) and IOP: 16.7¡1.8 mmHg (P,0.0001)]. ECD was significantly reduced by about 32 cell/mm2 for diabetics with duration of .10 years when compared with those with duration of ,10 years (P,0.05). CCT was thicker and IOP was higher for diabetics with duration of .10 years than those with duration of ,10 years (P.0.05). None of the measured parameters was significantly associated with diabetes duration and treatment modality (P.0.05). In conclusion, subjects with type 2 DM exhibit significant changes in ECD, IOP and CCT, which, however, are not correlated with disease duration or if the patients receive on insulin injection or oral medications.
Resumo:
Systematic reviews and meta-analyses are used to combine results across studies to determine an overall effect. Meta-analysis is especially useful for combining evidence to inform social policy, but meta-analyses of applied social science research may encounter practical issues arising from the nature of the research domain. The current paper identifies potential resolutions to four issues that may be encountered in systematic reviews and meta-analyses in social research. The four issues are: scoping and targeting research questions appropriate for meta-analysis; selecting eligibility criteria where primary studies vary in research design and choice of outcome measures; dealing with inconsistent reporting in primary studies; and identifying sources of heterogeneity with multiple confounded moderators. The paper presents an overview of each issue with a review of potential resolutions, identified from similar issues encountered in meta-analysis in medical and biological sciences. The discussion aims to share and improve methodology in systematic reviews and meta-analysis by promoting cross-disciplinary communication, that is, to encourage 'viewing through different lenses'.
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
To discover quantitative trait loci for intraocular pressure, amajor risk factor for glaucoma and the only modifiable one,weperformed agenome-wide association studyonadiscoverycohort of2175individualsfromSydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, Pcombined = 1.10 × 10-8). A copy of the G allele at this SNP is associated with an increase in mean IOP of 0.45 mmHg (95%CI = 0.30-0.61 mmHg). These results lend support to the implication of vesicle trafficking and glucocorticoid inducibility pathways in the determination of intraocular pressure and in the pathogenesis of primary open-angle glaucoma.
Resumo:
Glaucoma is a multifactorial long-term ocular neuropathy associated with progressive loss of the visual field, retinal nerve fiber structural abnormalities and optic disc changes. Like arterial hypertension it is usually a symptomless disease, but if left untreated leads to visual disability and eventual blindness. All therapies currently used aim to lower intraocular pressure (IOP) in order to minimize cell death. Drugs with new mechanisms of action could protect glaucomatous eyes against blindness. Renin-angiotensin system (RAS) is known to regulate systemic blood pressure and compounds acting on it are in wide clinical use in the treatment of hypertension and heart failure but not yet in ophthalmological use. There are only few previous studies concerning intraocular RAS, though evidence is accumulating that drugs antagonizing RAS can also lower IOP, the only treatable risk factor in glaucoma. The main aim of this experimental study was to clarify the expression of the renin-angiotensin system in the eye tissues and to test its potential oculohypotensive effects and mechanisms. In addition, the possible relationship between the development of hypertension and IOP was evaluated in animal models. In conclusion, a novel angiotensin receptor type (Mas), as well as ACE2 enzyme- producing agonists for Mas, were described for the first time in the eye structures participating in the regulation of IOP. In addition, a Mas receptor agonist significantly reduced even normal IOP. The effect was abolished by a specific receptor antagonist. Intraocular, local RAS would thus to be involved in the regulation of IOP, probably even more in pathological conditions such as glaucoma though there was no unambiguous relationship between arterial and ocular hypertension. The findings suggest the potential as antiglaucomatous drugs of agents which increase ACE2 activity and the formation of angiotensin (1-7), or activate Mas receptors.
Resumo:
In the study, we used the Agilent 8453 spectrophotometer (which is equipped with a limiting aperture that restricts the light beam to the central 5 mm of the contact lens), to measure the transmittance of various coloured contact lenses including the one Day Acuvue define manufactured by Johnson and Johnson which the authors represent. We measured the instrument baseline before the transmittance spectra of lenses were tested. The values of lens transmittances were thus the difference between baseline and lens measurement at each time. The transmittance measurements were obtained at 0.5 nm intervals, from 200 to 700 nm after a soak in saline to remove the influence of any surface active agents within the packaging products. The technique used in our study was not very different from how other research studies [2], [3], [4], [5] and [6] have measured the spectra transmittances of contact lenses...
Resumo:
The use of split lenses for multiple imaging and multichannel optical processing is demonstrated. Conditions are obtained for nonoverlapping of multipled images and avoiding crosstalk in the multichannel processing. Almost uniform intensity across the multipled images is an advantage here, while the low ƒ/No. of the split lens segments puts a limit in the resolution in image processing. Experimental results of multiple imaging and of a few multichannel processing are presented.