398 resultados para ILEORECTAL ANASTOMOSIS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The writers describe the muscular texture of the proglottides of Taenia saginata, Goeze, 1782, based upon microscopical preparations of mature and gravid proglottides stained by several methods. The muscular system of the proglottides of Taenia saginata is disposed mainly in two layers, a longitudinal and external one, and a deeper transverse layer, lining the body parenchym and internal organs. A circular or annular layer ranging under the cuticle is also referred. The writers emphasize the peculiar texture of the smooth muscle fibres, which only excepcionally do exist as isolated fibres, anastomosis between the fibres being the common histological appearence. Special features of the body parenchym such as calcareous bodies and globous nuclea scattered in the parenchym are also described.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: In 1989, we introduced a 1-stage procedure with orthotopic colonic transplants for esophageal stenosis. A pitfall of this procedure is frequent reflux and/or stasis in the transplants from the cologastric anastomosis. Since 1993, we have used a new antireflux wrap (ARW) using an anterior wrap technique similar to the Dor procedure but fixed to the right crus of the diaphragm.Purpose: The purpose of the study was to evaluate ARWs.Method: From 1993 to 2008, the records of 67 patients with an ARW were compared with 27 without ARW (either operated on before 1993 or ARW was not appropriate) after colonic transplant for caustic esophageal stenosis. Both groups otherwise underwent the same surgical procedure. Postoperative esophagograms done on postoperative day 10 were reviewed for the presence of gastrocolonic reflux and stasis in the transplant.Results: The reflux rate on the initial esophagogram was reduced from 48.1% to 7.5% using ARW. The incidence of reflux on later esophagograms was 40.0% with no ARW and 21.4% with ARW. The 25% long-term rate of stasis in the colonic transplant was not increased with ARW.Conclusions: A loose ARW in patients with colonic esophageal replacements reduces gastrocolic reflux without increasing the rate of stasis. In the long term, children adapt better to stasis than to reflux and are thus protected from occult inflammation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: In extreme situations, such as hyperacute rejection of heart transplant or major bleeding per-operating complications, an urgent heart explantation might be the only means of survival. The aim of this experimental study was to improve the surgical technique and the hemodynamics of an Extracorporeal Membrane Oxygenation (ECMO) support through a peripheral vascular access in an acardia model. Methods: An ECMO support was established in 7 bovine experiments (59±6.1 kg) by the transjugular insertion to the caval axis of a self-expanded cannula, with return through a carotid artery. After baseline measurements of pump flow and arterial and central venous pressure, ventricular fibrillation was induced (B), the great arteries were clamped, the heart was excised and right and left atria remnants, containing the pulmonary veins, were sutured together leaving an atrial septal defect (ASD) over the cannula in the caval axis. Measurements were taken with the pulmonary artery (PA) clamped (C) and anastomosed with the caval axis (D). Regular arterial and central venous blood gases tests were performed. The ANOVA test for repeated measures was used to test the null hypothesis and a Bonferroni t method for assessing the significance in the between groups pairwise comparison of mean pump flow. Results: Initial pump flow (A) was 4.3±0.6 L/min dropping to 2.8±0.7 L/min (P B-A= 0.003) 10 minutes after induction of ventricular fibrillation (B). After cardiectomy, with the pulmonary artery clamped (C) it augmented not significantly to 3.5±0.8 L/min (P C-B= 0.33, P C-A= 0.029). Finally, PA anastomosis to the caval axis was followed by an almost to baseline pump flow augmentation (4.1±0.7 L/min, P D-B= 0.009, P D-C= 0.006, P D-A= 0.597), permitting a full ECMO support in acardia by a peripheral vascular access. Conclusions: ECMO support in acardia is feasible, providing new opportunities in situations where heart must urgently be explanted, as in hyperacute rejection of heart transplant. Adequate drainage of pulmonary circulation is pivotal in order to avoid pulmonary congestion and loss of volume from the normal right to left shunt of bronchial vessels. Furthermore, the PA anastomosis to the caval axis not only improves pump flow but it also permits an ECMO support by a peripheral vascular access and the closure of the chest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: For over 50 years, radiocephalic wrist arteriovenous fistulae (RCAVF) have been the primary and best vascular access for haemodialysis. Nevertheless, early failure due to thrombosis or non-maturation is a major complication resulting in their abandonment. This prospective study was designed to investigate the predictive value of intra-operative blood flow on early failure of primary RCAVF before the first effective dialysis. METHODS: We enrolled patients undergoing creation of primary RCAVF for haemodialysis based on the pre-operative ultrasound vascular mapping discussed in a multidisciplinary approach. Intra-operative blood flow measurement was systematically performed once the anastomosis had been completed using a transit-time ultrasonic flowmeter. During the follow-up, blood flow was estimated by colour flow ultrasound at various intervals. Any events related to the RCAVF were recorded. RESULTS: Autogenous RCAVFs (n = 58) in 58 patients were constructed and followed up for an average of 30 days. Thrombosis and non-maturation occurred in eight (14%) and four (7%) patients, respectively. The intra-operative blood flow in functioning RCAVFs was significantly higher compared to non-functioning RCAVFs (230 vs 98 mL/min; P = 0.007), as well as 1 week (753 vs 228 mL/min; P = 0.0008) and 4 weeks (915 vs 245 mL/min, P < 0.0001) later. Blood flow volume measurements with a cut-off value of 120 mL/min had a sensitivity of 67%, specificity of 75% and positive predictive value of 91%. CONCLUSIONS: Blood flow <120 mL has a good predictive value for early failure in RCAVF. During the procedure, this cut-off value may be used to select appropriately which RCAVF should be investigated in the operation theatre in order to correct in real time any abnormality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

About 15% of adolescent males present with a varicocele. It rarely causes symptoms and is often diagnosed on the routine physical examination. There are evidences of an association between duration of a varicocele and testicular impairment. Surgical treatment is indicated in case of testicular growth arrest, testicular asymmetry, grade II or more, symptoms i.e. pain or swelling, parental or patient's anxiety. Several treatment options include open surgery (with or without micro-anastomosis), laparoscopy, embolization by interventional radiology, antegrade scrotal sclerotherapy. Informations should include a recurrence rate as hight as 15% whatever the technique may be, postoperative hydroceles and some testicular atrophies. Those complications can be delayed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A retrospective study to review the experience of a single center with surgery for aortic coarctation over a period of 30 years (1970-1999). METHODS: Criteria for inclusion: (a) aortic coarctation, isolated or associated with congenital heart defect; (b) surgery between 1970 and 1999. Data recorded: (1) date of surgery; (2) age at surgery; (3) associated lesions; (4) surgical technique; (5) simultaneous surgical procedures; (6) early and late surgical results in term of: (a) deaths; (b) need for reoperation because of re-coarctation or other cardiac lesion; (c) residual/recurrent pressure gradient, evaluated at cuff/Doppler at rest; (d) systemic hypertension, requiring medical treatment. RESULTS: One hundred and forty-one patients underwent surgery for aortic coarctation: 30 neonates, 29 infants, 45 children and 37 adults. Associated lesions were found in 8/37 (=21.6%) adults and in 73/104 (=70.1%) pediatric patients. There were no hospital deaths. During the follow-up there were one late death in the adults group (1/37=2.7%) and three late deaths in the pediatric group (3/104=2.9%), all unrelated with aortic coarctation. Re-operation because of re-coarctation occurred only in ten late survivors of the pediatric group (10/101=9.9%), 9/10 operated on before 1980 (P<0.00001). End-to-end anastomosis, enlarged to the aortic arch in neonates, was associated with the lowest incidence of re-coarctation (P<0.005). A significant (>20 mmHg at rest) pressure gradient was found in none of the adults, and in seven of the 91 pediatric patients (7/91=7.7%) late survivors. Three adults (3/36=8.3%) late survivors are on medical treatment to control systemic hypertension. CONCLUSIONS: The long-term results of our retrospective study confirm that surgery has to be considered the gold standard for the treatment of aortic coarctation. The interventional angioplasty techniques have to provide long-term outcome at least similar to the results obtained with surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: In addition to prosthetic rehabilitation, maxillary defects can also be surgically reconstructed. Soft-tissue reconstruction employs a radial forearm or latissimus dorsi muscle flap, while bony reconstruction can be achieved using a fibula, iliac crest, or scapular flap. Reconstruction using a scapular flap is further divided into two subgroups: the traditional scapular flap with the circumflex scapular artery as the donor vessel and the scapular angle flap with the angular artery originating from the thoracodorsal artery as the donor vessel. MATERIALS AND METHODS: We report on four patients who underwent successful reconstruction with a free scapular angle flap between 2009 and 2011, following maxillary resection due to malignancy. RESULTS: Vertical positioning of the scapular angle flap enables reconstruction of the facial contour, whereas its horizontal alignment and microvascular anastomosis makes a bony reconstruction of the hard palate possible. CONCLUSIONS: The versatility, low rate of donor site morbidity and shape of the scapular angle flap--which resembles that of the hard palate--render it ideal for plastic reconstruction. The suitability of bone quality for dental rehabilitation with implants is a topic of controversial discussion. The scapular angle flap represents an alternative to obturator prosthesis for the reconstruction of maxillary defects ≥ grade I according to Okay et al.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The process of repairing intestinal vascular lesions induced by schistosomiasis in mice was studied before and after curative chemotherapy, by means of histopathology coupled with injections of the mesenteric veins with India ink or plastic, in this case followed by corrosion in strong acid. The granulomas were avascular, mainly formed while within blood vessels, and were associated with distortion of the intestinal vasculature in their proximity, represented by tortuosities, focal dilatation, narrowing, and anastomosis of the mucosal and submucosal veins. Two to four months after cure of schistosomiasis involuting granulomas were seen to be slowly vascularized, a process going from the periphery toward the center of the granulomas. No intravascular granulomas were seen four months after treatment. The previously distorted mucosal and submucosal veins gradually regained their normal appearance, only a slight tortuosity remaining.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Until recently, cricotracheal resection (CTR) has not been commonly accepted as a treatment modality for severe subglottic stenosis in the pediatric age group. The reasons have included the risk of a possible dehiscence at the site of the anastomosis, the likelihood of injury to the recurrent laryngeal nerves, and the interference with normal growth of the larynx. Thirty-eight infants and children with a severe subglottic stenosis underwent a partial cricoid resection with primary thyrotracheal anastomosis. Thirty-three patients were tracheotomy-dependent at the time of surgery and 34 were referred cases; 27 were classified as grade III, and 10 as grade IV stenoses according to new Cotton's classification. Nineteen patients were younger than 3 years of age at the time of surgery. The tracheotomy was resected during the surgical procedure in 21 cases. Decannulation was achieved in 36/38 cases after an open procedure. There is one complete restenosis and one good result awaiting decannulation after further surgery for a Pierre Robin syndrome. The authors experienced no lesion of the recurrent laryngeal nerves and no fatality. Thirty-one patients show no exertional dyspnea, three a slight stridor while exercising, and two patients are not decannulated. The postoperative follow-up in longer than 10 years in eight cases. All patients show a normal growth of the larynx and trachea. Compared to laryngotracheoplasties, CTR gives better results for severe subglottic stenosis. This operation should become the treatment of choice for severe (grade III and IV) subglottic stenosis in infants and children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'anastomosi biliar en el trasplantament hepàtic és una de les causes més freqüents de morbiditat. En aquest treball s'ha analitzat l'evolució de les complicacions biliars després d'un trasplantament hepàtic en adults al llarg de 20 anys, comparant els primers 100 trasplantaments realitzats amb els darrers 200 entre 1985 i 2007. Resultats: la incidència de les complicacions biliars ha disminuït significativament al llarg dels anys, principalment a causa de l'abandonament de l'ús rutinari del tub de Kehr. La gravetat d'aquestes complicacions ha estat similar en ambdós grups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fifty-eight infants and children with a severe subglottic stenosis underwent a partial cricotracheal resection with primary thyrotracheal anastomosis. There were 2 grade II, 40 grade III, and 16 grade IV stenoses according to the Myer-Cotton classification. A 100% subglottic lumen was formed in 34 cases and a better than 80% lumen in 23 cases. Fifty-four of the 58 (93%) patients are presently decannulated; one patient sustained a complete restenosis and three patients with a better than 80% subglottic airway still await decannulation for the following reasons: severe tracheomalacia, bilateral cricoarytenoïd joint fixation and laryngeal malformation with fusion of the vocal cords in each case respectively. Forty-four patients have no exercise intolerance, 8 live fully normally but present a slight exertional dyspnea, one patient with a laryngeal malformation is decannulated but suffers from a severe exertional dyspnea, and 4 patients are still not decannulated. The voice is normal in 20 cases, a slight dysphonia is present in 17, a moderate to severe dysphonia in another 17 and 4 patients are still not decannulated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In extreme situations, such as hyperacute rejection of heart transplant or major heart trauma, heart preservation may not be possible. Our experimental team works on a project of peripheral extracorporeal membrane oxygenation (ECMO) support in acardia as a bridge to heart transplantation or artificial heart implantation. An ECMO support was established in five calves (58.6 ± 6.9 kg) by the transjugular insertion to the caval axis of a self-expanded cannula, with carotid artery return. After baseline measurements, ventricular fibrillation was induced, great arteries were clamped, heart was excised, and right and left atria remnants, containing pulmonary veins, were sutured together leaving an atrial septal defect over the caval axis cannula. Measurements of pump flow and arterial pressure were taken with the pulmonary artery clamped and anastomosed with the caval axis for a total of 6 hours. Pulmonary artery anastomosis to the caval axis provided an acceptable 6 hour hemodynamic stability, permitting a peripheral access ECMO support in extreme scenarios indicating a heart explantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: To assess the impact of neoadjuvant chemoradiotherapy (NCRT) on anastomotic leakage (AL) and other postoperative outcomes after esophageal cancer (EC) resection. BACKGROUND: Conflicting data have emerged from randomized studies regarding the impact of NCRT on AL. METHODS: Among 2944 consecutive patients operated on for EC between 2000 and 2010 in 30 European centers, patients treated by NCRT after surgery (n = 593) were compared with those treated by primary surgery (n = 1487). Multivariable analyses and propensity score matching were used to compensate for the differences in some baseline characteristics. RESULTS: Patients in the NCRT group were younger, with a higher prevalence of male sex, malnutrition, advanced tumor stage, squamous cell carcinoma, and surgery after 2005 when compared with the primary surgery group. Postoperative AL rates were 8.8% versus 10.6% (P = 0.220), and 90-day postoperative mortality and morbidity rates were 9.3% versus 7.2% (P = 0.110) and 33.4% versus 32.1% (P = 0.564), respectively. Pulmonary complication rates did not differ between groups (24.6% vs 22.5%; P = 0.291), whereas chylothorax (2.5% vs 1.2%; P = 0.020), cardiovascular complications (8.6% vs 0.1%; P = 0.037), and thromboembolic events (8.6% vs 6.0%; P = 0.037) were higher in the NCRT group. After propensity score matching, AL rates were 8.8% versus 11.3% (P = 0.228), with more chylothorax (2.5% vs 0.7%; P = 0.030) and trend toward more cardiovascular and thromboembolic events in the NCRT group (P = 0.069). Predictors of AL were high American Society of Anesthesiologists scores, supracarinal tumoral location, and cervical anastomosis, but not NCRT. CONCLUSIONS: Neoadjuvant chemoradiotherapy does not have an impact on the AL rate after EC resection (NCT 01927016).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present numerical simulations of continuous flow left ventricle assist device implantation with the aim of comparing difference in flow rates and pressure patterns depending on the location of the anastomosis and the rotational speed of the device. Despite the fact that the descending aorta anastomosis approach is less invasive, since it does not require a sternotomy and a cardiopulmonary bypass, its benefits are still controversial. Moreover, the device rotational speed should be correctly chosen to avoid anomalous flow rates and pressure distribution in specific location of the cardiovascular tree. With the aim of assessing the differences between these two approaches and device rotational speed in terms of flow rate and pressure waveforms, we set up numerical simulations of network of one-dimensional models where we account for the presence of an outflow cannula anastomosed to different locations of the aorta. Then, we use the resulting network to compare the results of the two different cannulations for several stages of heart failure and different rotational speed of the device. The inflow boundary data for the heart and the cannulas are obtained from a lumped parameters model of the entire circulatory system with an assist device, which is validated with clinical data. The results show that ascending and descending aorta cannulations lead to similar waveforms and mean flow rate in all the considered cases. Moreover, regardless of the anastomosis region, the rotational speed of the device has an important impact on wave profiles; this effect is more pronounced at high RPM.