990 resultados para F AAS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Data regarding immunomodulatory effects of parenteral n-3 fatty acids in sepsis are conflicting. In this study, the effect of administration of parenteral n-3 fatty acids on markers of brain injury, incidence of sepsis-associated delirium, and inflammatory mediators in septic patients was investigated. METHODS: Fifty patients with sepsis were randomized to receive either 2 ml/kg/day of a lipid emulsion containing highly refined fish oil (equivalent to n-3 fatty acids 0.12 mg/kg/day) during 7 days after admission to the intensive care unit or standard treatment. Markers of brain injury and inflammatory mediators were measured on days 1, 2, 3 and 7. Assessment for sepsis-associated delirium was performed daily. The primary outcome was the difference in S-100β from baseline to peak level between both the intervention and the control group, compared by t-test. Changes of all markers over time were explored in both groups, fitting a generalized estimating equations model. RESULTS: Mean difference in change of S-100β from baseline to peak level was 0.34 (95% CI: -0.18-0.85) between the intervention and control group, respectively (P = 0.19). We found no difference in plasma levels of S-100β, neuron-specific enolase, interleukin (IL)-6, IL-8, IL-10, and C-reactive protein between groups over time. Incidence of sepsis-associated delirium was 75% in the intervention and 71% in the control groups (risk difference 4%, 95% CI -24-31%, P = 0.796). CONCLUSION: Administration of n-3 fatty acids did not affect markers of brain injury, incidence of sepsis-associated delirium, and inflammatory mediators in septic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aims of the study were to evaluate the prevalence of acute coronary syndrome (ACS) among patients presenting with atypical chest pain who are evaluated for acute aortic syndrome (AAS) or pulmonary embolism (PE) with computed tomoangiography (CTA) and discuss the rationale for the use of triple rule-out (TRO) protocol for triaging these patients. METHODS: This study is a retrospective analysis of patients presenting with atypical chest pain and evaluated with thoracic (CTA), for suspicion of AAS/PE. Two physicians reviewed patient files for demographic characteristics, initial CT and final clinical diagnosis. Patients were classified according to CTA finding into AAS, PE and other diagnoses and according to final clinical diagnosis into AAS, PE, ACS and other diagnoses. RESULTS: Four hundred and sixty-seven patients were evaluated: 396 (84.8%) patients for clinical suspicion of PE and 71 (15.2%) patients for suspicion of AAS. The prevalence of ACS and AAS was low among the PE patients: 5.5% and 0.5% respectively (P = 0.0001), while the prevalence of ACS and PE was 18.3% and 5.6% among AAS patients (P = 0.14 and P = 0.34 respectively). CONCLUSION: The prevalence of ACS and AAS among patients suspected clinically of having PE is limited while the prevalence of ACS and PE among patients suspected clinically of having AAS is significant. Accordingly patients suspected for PE could be evaluated with dedicated PE CTA while those suspected for AAS should still be triaged using TRO protocol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: Sudden cardiac death (SCD) is a severe burden of modern medicine. Aldosterone antagonist is publicized as effective in reducing mortality in patients with heart failure (HF) or post myocardial infarction (MI). Our study aimed to assess the efficacy of AAs on mortality including SCD, hospitalization admission and several common adverse effects. METHODS: We searched Embase, PubMed, Web of Science, Cochrane library and clinicaltrial.gov for randomized controlled trials (RCTs) assigning AAs in patients with HF or post MI through May 2015. The comparator included standard medication or placebo, or both. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Event rates were compared using a random effects model. Prospective RCTs of AAs with durations of at least 8 weeks were selected if they included at least one of the following outcomes: SCD, all-cause/cardiovascular mortality, all-cause/cardiovascular hospitalization and common side effects (hyperkalemia, renal function degradation and gynecomastia). RESULTS: Data from 19,333 patients enrolled in 25 trials were included. In patients with HF, this treatment significantly reduced the risk of SCD by 19% (RR 0.81; 95% CI, 0.67-0.98; p = 0.03); all-cause mortality by 19% (RR 0.81; 95% CI, 0.74-0.88, p<0.00001) and cardiovascular death by 21% (RR 0.79; 95% CI, 0.70-0.89, p<0.00001). In patients with post-MI, the matching reduced risks were 20% (RR 0.80; 95% CI, 0.66-0.98; p = 0.03), 15% (RR 0.85; 95% CI, 0.76-0.95, p = 0.003) and 17% (RR 0.83; 95% CI, 0.74-0.94, p = 0.003), respectively. Concerning both subgroups, the relative risks respectively decreased by 19% (RR 0.81; 95% CI, 0.71-0.92; p = 0.002) for SCD, 18% (RR 0.82; 95% CI, 0.77-0.88, p < 0.0001) for all-cause mortality and 20% (RR 0.80; 95% CI, 0.74-0.87, p < 0.0001) for cardiovascular mortality in patients treated with AAs. As well, hospitalizations were significantly reduced, while common adverse effects were significantly increased. CONCLUSION: Aldosterone antagonists appear to be effective in reducing SCD and other mortality events, compared with placebo or standard medication in patients with HF and/or after a MI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selenium is both essential and toxic to man and animals, depending on the concentration and the ingested form. Most fruits and vegetables are poor sources of selenium, but coconut can be a good selenium source. Samples were suspended (1 + 4 v/v) in a mixture of tertiary amines soluble in water (10% v/v CFA-C). This simple sample treatment avoided contamination and decreased the analysis time. The standard additions method was adopted for quantification. The action of the autosampler was improved by the presence of the amines mixture in the suspension. A Varian model AA-800 atomic absorption spectrometer equipped with a graphite furnace and a GTA 100 autosampler was used for selenium determination in coconut water and coconut milk. Background correction was performed by means of the Zeeman effect. Pyrolytically coated graphite tubes were employed. Using Pd as chemical modifier, the pyrolysis and the atomization temperatures were set at 1400 and 2200ºC, respectively. For six samples, the selenium concentration in coconut water varied from 6.5 to 21.0 mug L-1 and in coconut milk from 24.2 to 25.1 mug L-1. The accuracy of the proposed method was evaluated by an addition-recovery experiment and all recovered values are in the 99.5-102.3% range. The main advantage of the proposed method is that it can be directly applied without sample decomposition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It was evaluated the applicability of Langmuir, Freundlich and Temkin models to copper adsorption in three classes of soils. Fractions of each soil were added to test tubes containing growing concentrations of the metal in solution. The tubes were shaken and the copper concentrations were determined in the extracts by atomic absorption spectrometry (AAS). The models offered a good fit for the experimental data indicating that presence of silicated clay had high influence on copper sorption. The Langmuir isotherm showed high influence of the organic matter in the absorption phenomenon. It was evidenced the importance of further studies related to Temkin model.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this review it is presented some aspects of electrothermal atomic absorption spectrometry with tungsten coil (ETAW-AAS) since its beginning until the present days as well as the perspectives for this technique. Some aspects concerning its development and theoretical concepts are discussed. The analytical figures of merit such as limit of detection (LD), characteristic mass (m0), relative standard deviation (RSD), accuracy and precision are evaluated, compared and discussed considering published works. It is also evaluated its advantages, applications, limitations and instrumental development. The use of diode laser as radiation source and its perspectives to ETAW are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The historical development of atomic spectrometry techniques based on chemical vapor generation by both batch and flow injection sampling formats is presented. Detection via atomic absorption spectrometry (AAS), microwave induced plasma optical emission spectrometry (MIP-OES), inductively coupled plasma optical emission spectrometry (ICP-OES) , inductively coupled plasma mass spectrometry (ICP-MS) and furnace atomic nonthermal excitation spectrometry (FANES) are considered. Hydride generation is separately considered in contrast to other methods of generation of volatile derivatives. Hg <FONT FACE=Symbol>&frac34;FONT> CVAAS (cold vapor atomic absorption spectrometry) is not considered here. The current state-of-the-art, including extension, advantages and limitations of this approach is discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The layered precursor of MCM-22 was prepared with different Si/Al ratios: 15, 25, 50, 100 and ¥. Upon heat treatment these precursors form MCM-22 zeolite. Both layered precursor and MCM-22 zeolite were characterized by several techniques: Chemical Analysis by Atomic Absorption Spectroscopy (AAS), X-Ray Diffraction (XRD), Thermo-gravimetric Analysis (TGA), Pore Analysis by N2 and Ar adsorption, Scanning Electron Microscopy (SEM), Infrared Spectroscopy (IR) and Temperature Programmed Desorption of ammonium (TPD).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lead absorption is influenced by the species that are formed and the physicochemical characteristics of lead, among others. Lead plasma concentration is < 5% of total blood lead and represents the biologically active fraction able to cross the cell membranes. Health risks mainly depend on a specific metal and its species. Speciation analysis is the analytical activity of identifying and determining different metal species. Chromatographic methods are very useful in the identification of species and the techniques most used to determine metals in biological fluids are ICP OES/MS and AAS. Lead speciation analysis in blood plasma is fundamental for understanding and evaluating the interaction mechanisms between that analyte and its biological targets.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thermospray flame furnace Atomic Absorption Spectrometry (TS-FF-AAS) was used for the total determination of Cd, Pb and Zn in fresh water and seawater samples at µg L-1 levels, and in marine sediment samples at µg g-1 levels. Using a sample loop of 50 µL and a peristaltic pump the samples were transported into the metallic tube placed over an air/acetylene flame, through a ceramic capillary (o.d. = 3.2 mm) containing two parallel internal orifices (i.d = 0.5 mm). The detection limits determined for Cd, Pb and Zn using a synthetic water matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2) were 0.32 µg L-1; 2.6 µg L-1 and 0.21 µg L-1 respectively. The methodology by TS-FF-AAS was validated by determination of Cd, Pb and Zn in certified reference materials of water and marine sediment, and the t-test for differences between means was applied. No statistically significant differences were established in fresh water and seawater (p>0.05), whereas differences became apparent in marine sediment (p<0.03).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of an internal standard (IS) in ET AAS can be considered a new trend after the commercial introduction of a simultaneous spectrometer. The evaluation of experimental data to choose the most appropriate IS can be done by comparing correlation graphs. They were used to verify the resemblance among the simultaneous measurements obtained for the analyte(s) and the IS by inductively coupled plasma optical emission spectrometry (ICPOES). The judicious selection of IS by using correlation graphs for determinations by ET AAS can be exploited to improve the precision and accuracy of the analytical results. Therefore, a new approach for studying the use of IS in ET AAS is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work proposes a simple, fast and inexpensive method to determine As in natural waters, using X-ray fluorescence. 50 µL of each sample containing 100 mg L-1 of yttrium as internal standard were deposited over a 2.5 µm thickness MylarTM film. The samples were dried at 50 °C for 2 h. X-ray spectra were obtained using an EDXRF apparatus. The accuracy was determined by analyte addition/recovery and by comparison with Hydride Generation Atomic Absorption Spectrometry (HG AAS). A recovery of about 100% was obtained and the results were in good agreement with HG AAS. The method showed a relative standard deviation of 6.8% and a detection limit of 10.5 µg L-1 of As.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and reliable ashing procedure is proposed for the preparation of used lubricating oil samples for the determination of Zn, Fe, Pb, Ni and Cu by the flame atomic absorption spectrometry technique. Sulphanilic acid was added to oil samples, the mixture coked and the coke ashed at 550 ºC. The solutions of the ash were analysed by flame AAS for these metals. The quantification limits were 38.250 µg g-1 for Zn, 4.550 µg g-1 for Fe, 1.562 µg g-1 for Pb, 1.450 µg g-1 for Ni, and 0.439 µg g-1 for Cu. The determinations, in lubricating oil, showed good precision and accuracy with recoveries between 90 and 110 %, indicating a negligible matrix effect in the experiments using addition of analyte, with relative standard deviation lower than 5%. The results for analysis of wastewater contamined by theses lubricants showed a very high relative standard deviation.