OBJECTIVE: The objective of this study was to describe the distribution of conjunctival ultraviolet autofluorescence (UVAF) in an adult population. METHODS: We conducted a cross-sectional, population-based study in the genetic isolate of Norfolk Island, South Pacific Ocean. In all, 641 people, aged 15 to 89 years, were recruited. UVAF and standard (control) photographs were taken of the nasal and temporal interpalpebral regions bilaterally. Differences between the groups for non-normally distributed continuous variables were assessed using the Wilcoxon-Mann-Whitney ranksum test. Trends across categories were assessed using Cuzick's non-parametric test for trend or Kendall's rank correlation τ. RESULTS: Conjunctival UVAF is a non-parametric trait with a positively skewed distribution. Median amount of conjunctival UVAF per person (sum of four measurements; right nasal/temporal and left nasal/temporal) was 28.2 mm(2) (interquartile range 14.5-48.2). There was an inverse, linear relationship between UVAF and advancing age (P<0.001). Males had a higher sum of UVAF compared with females (34.4 mm(2) vs 23.2 mm(2), P<0.0001). There were no statistically significant differences in area of UVAF between right and left eyes or between nasal and temporal regions. CONCLUSION: We have provided the first quantifiable estimates of conjunctival UVAF in an adult population. Further data are required to provide information about the natural history of UVAF and to characterise other potential disease associations with UVAF. UVR protective strategies should be emphasised at an early age to prevent the long-term adverse effects on health associated with excess UVR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We aimed to determine the prevalence and associations of refractive error on Norfolk Island. DESIGN: Population-based study on Norfolk Island, South Pacific. PARTICIPANTS: All permanent residents on Norfolk Island aged ≥ 15 years were invited to participate. METHODS: Patients underwent non-cycloplegic autorefraction, slit-lamp biomicroscope examination and biometry assessment. Only phakic eyes were analysed. MAIN OUTCOME MEASURES: Prevalence and multivariate associations of refractive error and myopia. RESULTS: There were 677 people (645 right phakic eyes, 648 left phakic eyes) aged ≥ 15 years were included in this study. Mean age of participants was 51.1 (standard deviation 15.7; range 15-81). Three hundred and seventy-six people (55.5%) were female. Adjusted to the 2006 Norfolk Island population, prevalence estimates of refractive error were as follows: myopia (mean spherical equivalent ≥ -1.0 D) 10.1%, hypermetropia (mean spherical equivalent ≥ 1.0 D) 36.6%, and astigmatism 17.7%. Significant independent predictors of myopia in the multivariate model were lower age (P < 0.001), longer axial length (P < 0.001), shallower anterior chamber depth (P = 0.031) and increased corneal curvature (P < 0.001). Significant independent predictors of refractive error were increasing age (P < 0.001), male gender (P = 0.009), Pitcairn ancestry (P = 0.041), cataract (P < 0.001), longer axial length (P < 0.001) and decreased corneal curvature (P < 0.001). CONCLUSIONS: The prevalence of myopia on Norfolk Island is lower than on mainland Australia, and the Norfolk Island population demonstrates ethnic differences in the prevalence estimates. Given the significant associations between refractive error and several ocular biometry characteristics, Norfolk Island may be a useful population in which to find the genetic basis of refractive error.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To describe the recruitment, ophthalmic examination methods and distribution of ocular biometry of participants in the Norfolk Island Eye Study, who were individuals descended from the English Bounty mutineers and their Polynesian wives. Methods: All 1,275 permanent residents of Norfolk Island aged over 15 years were invited to participate, including 602 individuals involved in a 2001 cardiovascular disease study. Participants completed a detailed questionnaire and underwent a comprehensive eye assessment including stereo disc and retinal photography, ocular coherence topography and conjunctival autofluorescence assessment. Additionally, blood or saliva was taken for DNA testing. Results: 781 participants aged over 15 years were seen (54% female), comprising 61% of the permanent Island population. 343 people (43.9%) could trace their family history to the Pitcairn Islanders (Norfolk Island Pitcairn Pedigree). Mean anterior chamber depth was 3.32mm, mean axial length (AL) was 23.5mm, and mean central corneal thickness was 546 microns. There were no statistically significant differences in these characteristics between persons with and without Pitcairn Island ancestry. Mean intra-ocular pressure was lower in people with Pitcairn Island ancestry: 15.89mmHg compared to those without Pitcairn Island ancestry 16.49mmHg (P = .007). The mean keratometry value was lower in people with Pitcairn Island ancestry (43.22 vs. 43.52, P = .007). The corneas were flatter in people of Pitcairn ancestry but there was no corresponding difference in AL or refraction. Conclusion: Our study population is highly representative of the permanent population of Norfolk Island. Ocular biometry was similar to that of other white populations. Heritability estimates, linkage analysis and genome-wide studies will further elucidate the genetic determinants of chronic ocular diseases in this genetic isolate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Over 40% of the permanent population of Norfolk Island possesses a unique genetic admixture dating to Pitcairn Island in the late 18 th century, with descendents having varying degrees of combined Polynesian and European ancestry. We conducted a population-based study to determine the prevalence and causes of blindness and low vision on Norfolk Island. Methods: All permanent residents of Norfolk Island aged ≥ 15 years were invited to participate. Participants completed a structured questionnaire/interview and underwent a comprehensive ophthalmic examination including slit-lamp biomicroscopy. Results: We recruited 781 people aged ≥ 15, equal to 62% of the permanent population, 44% of whom could trace their ancestry to Pitcairn Island. No one was bilaterally blind. Prevalence of unilateral blindness (visual acuity [VA] < 6/60) in those aged ≥ 40 was 1.5%. Blindness was more common in females (P=0.049) and less common in people with Pitcairn Island ancestry (P<0.001). The most common causes of unilateral blindness were age-related macular degeneration (AMD), amblyopia, and glaucoma. Five people had low vision (Best-Corrected VA < 6/18 in better eye), with 4 (80%) due to AMD. People with Pitcairn Island ancestry had a lower prevalence of AMD (P<0.001) but a similar prevalence of glaucoma to those without Pitcairn Island ancestry. Conclusions: The prevalence of blindness and visual impairment in this isolated Australian territory is low, especially amongst those with Pitcairn Island ancestry. AMD was the most common cause of unilateral blindness and low vision. The distribution of chronic ocular diseases on Norfolk Island is similar to mainland Australian estimates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the impact of polystyrene sodium sulfonate (PolyNaSS) grafting onto the osseo-integration of a polyethylene terephthalate artificial ligament (Ligament Advanced Reinforcement System, LARS™) used for Anterior Cruciate Ligament (ACL). The performance of grafted and non-grafted ligaments was assessed in vitro by culturing human osteoblasts under osteogenic induction and this demonstrated that the surface modification was capable of up-regulating the secretion of ALP and induced higher level of mineralisation as measured 6 weeks post-seeding by Micro-Computed Tomography. Grafted and non-grafted LARS™ were subsequently implanted in an ovine model for ACL reconstruction and the ligament-to-bone interface was evaluated by histology and biomechanical testings 3 and 12 months post-implantation. The grafted ligaments exhibited more frequent direct ligament-to-bone contact and bone formation in the core of the ligament at the later time point than the non-grafted specimens, the grafting also significantly reduced the fibrous encapsulation of the ligament 12 months post-implantation. However, this improved osseo-integration was not translated into a significant increase in the biomechanical pull-out loads. These results provide evidences that PolyNaSS grafting improved the osseo-integration of the artificial ligament within the bone tunnels. This might positively influence the outcome of the surgical reconstructions, as higher ligament stability is believed to limit micro-movement and therefore permits earlier and enhanced healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Successful anatomic fitting of a total artificial heart (TAH) is vital to achieve optimal pump hemodynamics after device implantation. Although many anatomic fitting studies have been completed in humans prior to clinical trials, few reports exist that detail the experience in animals for in vivo device evaluation. Optimal hemodynamics are crucial throughout the in vivo phase to direct design iterations and ultimately validate device performance prior to pivotal human trials. In vivo evaluation in a sheep model allows a realistically sized representation of a smaller patient, for which smaller third-generation TAHs have the potential to treat. Our study aimed to assess the anatomic fit of a single device rotary TAH in sheep prior to animal trials and to use the data to develop a threedimensional, computer-aided design (CAD)-operated anatomic fitting tool for future TAH development. Following excision of the native ventricles above the atrio-ventricular groove, a prototype TAH was inserted within the chest cavity of six sheep (28–40 kg).Adjustable rods representing inlet and outlet conduits were oriented toward the center of each atrial chamber and the great vessels, with conduit lengths and angles recorded for future analysis. A threedimensional, CAD-operated anatomic fitting tool was then developed, based on the results of this study, and used to determine the inflow and outflow conduit orientation of the TAH. The mean diameters of the sheep left atrium, right atrium, aorta, and pulmonary artery were 39, 33, 12, and 11 mm, respectively. The center-to-center distance and outer-edge-to-outer-edge distance between the atria, found to be 39 ± 9 mm and 72 ± 17 mm in this study, were identified as the most critical geometries for successful TAH connection. This geometric constraint restricts the maximum separation allowable between left and right inlet ports of a TAH to ensure successful alignment within the available atrial circumference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microstructure of an artificial grain boundary in an YBa2Cu3O7-δ (YBCO) thin film grown on a (100)(110), [001]-tilt yttria-stabilized-zirconia (YSZ) bicrystal substrate has been studied using transmission electron microscopy (TEM). The orientation relationship between the YBCO film and the YSZ substrate was [001]YBCO∥[001]YSZ and [110]YBCO∥[100]YSZ for each half of the bicrystal film. However, the exact boundary geometry of the bicrystal substrate was not transferred to the film. The substrate boundary was straight while the film boundary was wavy. In several cases there was bending of the lattice confined within a distance of a few basal-plane lattice spacings from the boundary plane and microfaceting. No intergranular secondary phase was observed but about 25% of the boundary was covered by c-axis-tilted YBCO grains and a-axis-oriented grains, both of which were typically adjacent to CuO grains or surrounded by a thin Cu-rich amorphous layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microstructure of artificial grain boundaries in YBa2Cu3O7-δ (YBCO) thin films grown on [001] tilt YZrO2 (YSZ) bicrystal substrates has been characterized using transmission electron microscopy and atomic force microscopy. Despite a relatively straight morphology of the substrate boundaries, the film boundaries were wavy. The waviness was a result of the combined effects of grooving at the substrate boundaries prior to the film deposition and an island-growth mechanism for YBCO on YSZ substrates. The dihedral angle of the groove walls varied with the misorientation angle and depended on the symmetry of the substrate boundary. The amplitudes of the film boundary waviness compared well with the widths of the grooves. In addition, the grooves induced local bending of the YBCO lattice planes and additional tilt components perpendicular to the c-axis close to the film boundaries. © 1995.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Weak links were fabricated by pulsed laser deposition of YBa 2Cu3Ox thin films on Y-ZrO2 bicrystal substrates. They were formed by transferring the bicrystal boundary into the epitaxial film during the film growth. Their properties were determined by the misorientation angle ( theta ) between the two halves of the bicrystal. The transport properties of the weak links were studied as a function of theta and an exponential dependence of the weak link critical current density was observed for angles up to 45 degrees . Clear Josephson effects with good microwave and magnetic field response were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have studied weak links and dc-SQUIDs made from pulsed laser deposited YBa2Cu3O7-δ thin films on Y-ZrO 2 bicrystal substrates. The transport properties of the weak links were studied as a function of the misorientation angle (θ) between the two halves of the bicrystal and an exponential dependence of the weak link critical current density was observed for angles up to 40°at 77 K. Josephson effects with clear microwave and magnetic field responses were observed. An optimum dc-SQUID performance at 77 K was obtained for θ=32°. At this temperature, we achieved a periodic magnetic field response with a modulation depth of 12 μV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Engineered grain boundary Josephson junctions in YBaCuO were formed on bicrystal Y-ZrO2 substrates. Laser deposited films were patterned into micron size microbridges. The authors obsd. a pronounced correlation between superconducting transport properties of grain boundary junctions and the misorientation angle θ between the two halves of the bicrystal. The crit. Josephson current Ic decreased about four orders of magnitude as θ was increased from 0 to 45 degrees. Clear microwave and magnetic field responses were obsd. at 77 K. At this temp., crit. current times normal resistance products, IcRn, of up to 1 mV were measured for low angle grain boundaries, and Shapiro steps were obsd. up to that voltage. DC SQUIDs were fabricated, and best performance at 77 K was obtained for θ = 32° with a 4-μm strip width. To utilize the higher IcRn value of a lower θ, submicron junctions have to be developed. [on SciFinder(R)]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose to evaluate the effects of the wearer’s pupil size and spherical aberration on visual performance with centre-near, aspheric multifocal contact lenses (MFCLs). The advantage of binocular over monocular vision was also investigated. Methods Twelve young volunteers, with an average age of 27±5 years, participated in the study. LogMAR Visual Acuity (VA) was measured under cycloplegia for a range of defocus levels (from +3.0 to -3.0D, in 0.5D steps) with no correction and with three aspheric MFCLs (Air Optix Aqua Multifocal, Ciba Vision, Duluth, GA, US) with a centre-near design, providing correction for “Low”, “Med” and “High” near demands. Measurements were performed for all combinations of the following conditions: i) artificial pupils of 6mm and 3mm diameter, ii) binocular and monocular (dominant eye) vision. Depth-of-focus (DOF) was calculated from the VA vs. defocus curves. Ocular aberrations under cycloplegia were measured using iTrace. Results VA at -3.0D defocus (simulating near performance) was statistically higher for the 3mm than for the 6mm pupil (p=0.006), and for binocular rather than for monocular vision (p<0.001). Similarly, DOF was better for the 3mm pupil (p=0.002) and for binocular viewing conditions (p<0.001, ANOVA). Both VA at –3.0D defocus and DOF increased as the “addition” of the MFCL correction increased. Finally, with the centre-near MFCLs a linear correlation was found between VA at –3.0D defocus and the wearer’s ocular spherical aberration (R2=0.20 p<0.001 for 6mm data), with the eyes exhibiting the higher positive spherical aberration experiencing lower VAs. By contrast, no correlation was found between VA and spherical aberration at 0.00D defocus (distance vision). Conclusions Both near VA and depth-of-focus improve with these MFCLs, with the effects being more pronounced for small pupils and binocular than for monocular vision. Coupling of the wearer’s ocular spherical aberration with the aberration profiles provided by MFCLs affects their functionality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: GABA antagonists inhibit experimental myopia in chick and GABA receptors have been localized to chick sclera and the retinal pigment epithelium (RPE). The RPE and the choroid alter scleral DNA and glycosaminoglycan (GAG) content in vitro; opposite effects have been observed for tissues from myopic and hyperopic eyes. The aim was to determine the effect of GABAergic agents on the DNA and GAG content of chick scleral fibroblasts directly and in co-culture with ocular tissues from myopic and hyperopic chick eyes. Materials and Methods: Primary cultures of fibroblastic cells expressing vimentin and α-smooth muscle actin were established. GABAergic agents were added separately (i) to the culture medium of the scleral cells and (ii) to the culture medium of the scleral cells with the addition of posterior eye cup tissue (retina, RPE, retina + RPE, choroid + RPE) to cell culture inserts. Ocular tissues were obtained from chick eyes wearing + 15D (lens-induced hyperopia, LIH) or −15D lenses (lens-induced myopia, LIM) for three days (post-hatch day 5–8) (n = 12). GAG and DNA content of scleral fibroblasts were measured. Results: GABA agents had a small direct effect on scleral cell GAG and DNA content but a larger effect was measured when GABA agents were added to the culture medium with myopic and hyperopic RPE and choroid + RPE tissues. GABA agonists increased (p = 0.002) whereas antagonists decreased (p = 0.0004) DNA content of scleral cells; effects were opposite for scleral GAG content. GABA agents significantly altered the effect of both LIM and LIH tissues (p = 0.0005) compared to control; the effects were greater for LIM tissue versus LIH tissue co-culture (p = 0.0004). Conclusion: GABAergic agents affect the DNA and GAG content of scleral fibroblasts both directly and when co-cultured with ocular tissues. GABA antagonists that prevent myopia development in chick model could act via a scleral mechanism utilizing the RPE/choroid.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total Artificial Hearts are mechanical pumps which can be used to replace the failing natural heart. This novel study developed a means of controlling a new design of pump to reproduce physiological flow bringing closer the realisation of a practical artificial heart. Using a mathematical model of the device, an optimisation algorithm was used to determine the best configuration for the magnetic levitation system of the pump. The prototype device was constructed and tested in a mock circulation loop. A physiological controller was designed to replicate the Frank-Starling like balancing behaviour of the natural heart. The device and controller provided sufficient support for a human patient while also demonstrating good response to various physiological conditions and events. This novel work brings the design of a practical artificial heart closer to realisation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In plants, double-stranded RNA (dsRNA) is an effective trigger of RNA silencing, and several classes of endogenous small RNA (sRNA), processed from dsRNA substrates by DICER-like (DCL) endonucleases, are essential in controlling gene expression. One such sRNA class, the microRNAs (miRNAs) control the expression of closely related genes to regulate all aspects of plant development, including the determination of leaf shape, leaf polarity, flowering time, and floral identity. A single miRNA sRNA silencing signal is processed from a long precursor transcript of nonprotein-coding RNA, termed the primary miRNA (pri-miRNA). A region of the pri-miRNA is partially self-complementary allowing the transcript to fold back onto itself to form a stem-loop structure of imperfectly dsRNA. Artificial miRNA (amiRNA) technology uses endogenous pri-miRNAs, in which the miRNA and miRNA*(passenger strand of the miRNA duplex) sequences have been replaced with corresponding amiRNA/ amiRNA*sequences that direct highly efficient RNA silencing of the targeted gene. Here, we describe the rules for amiRNA design, as well as outline the PCR and bacterial cloning procedures involved in the construction of an amiRNA plant expression vector to control target gene expression in Arabidopsis thaliana. © 2014 Springer Science+Business Media New York.