933 resultados para Dye penetration


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Soil quality indicators such as penetration resistance (PR) and bulk density (BD) are traditionally determined in a single undisturbed soil sample. The aim of this study was to assess the effect of PR measurements of undisturbed samples on the determination of BD in the same sample of two soils differing in clay contents. To this end, samples were collected from the 0.00-0.10 and 0.10-0.20 m layers of two soils of clayey and very clayey texture. Volumetric rings were used to collect a total of 120 undisturbed soil samples from each soil layer that were divided into two subsets containing 60 units each. One sample set, designated “perforated samples”, was used to determine PR and BD in the same undisturbed sample; the other, named “intact samples”, was used to determine BD only. Bulk density values for perforated and intact samples were compared by analysis of variance, using a completely randomized experimental design. Means were compared by the t-test at 5 %. The BD values for the clayey soil were similar in perforated and intact samples from the two layers. However, BD of the very clayey soil was lower in the perforated than in the intact samples at both depths. Therefore, PR and BD in clayey soils can be accurately determined in the same undisturbed sample whereas in very clayey soils, different samples are required for this purpose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of soil load-bearing capacity from mathematical models that relate preconsolidation pressure (σp) to mechanical resistance to penetration (PR) and gravimetric soil water content (U) is important for defining strategies to prevent compaction of agricultural soils. Our objective was therefore to model the σp and compression index (CI) according to the PR (with an impact penetrometer in the field and a static penetrometer inserted at a constant rate in the laboratory) and U in a Rhodic Eutrudox. The experiment consisted of six treatments: no-tillage system (NT); NT with chiseling; and NT with additional compaction by combine traffic (passing 4, 8, 10, and 20 times). Soil bulk density, total porosity, PR (in field and laboratory measurements), U, σp, and CI values were determined in the 5.5-10.5 cm and 13.5-18.5 cm layers. Preconsolidation pressure (σp) and CI were modeled according to PR in different U. The σp increased and the CI decreased linearly with increases in the PR values. The correlations between σp and PR and PR and CI are influenced by U. From these correlations, the soil load-bearing capacity and compaction susceptibility can be estimated by PR readings evaluated in different U.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a recent letter, Rosen claims to justify ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to determine the comparative effectiveness of standard D-57 concrete and Iowa system Low Slump Dense Concrete in preventing threshold levels of chloride from penetrating the concrete slabs to the reinforcing steel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples of both recycled and nonrecycled asphaltic concrete were extracted in increments by the Abson Recovery Method and the penetration of the asphalt from each increment determined. The recycled projects were plantsite operations containing various amounts of virgin gravel. Cored samples were taken from the pavements on Kossuth County roads that were constructed as recycled projects in 1975, 1976, and 1977. Cored samples were also taken from a Kossuth County paving project done in 1975, that was not recycled. Comparison mix samples from 1978 construction projects in Marshall and Woodbury Counties of non - recycled projects are included. The test data from the penetrations of the recovered asphalt indicates that mixing of the old and new asphalt occurs very extensively in the hot recycling process. In laboratory controlled conditions it is difficult to coat aggregates with different penetration asphalts and prevent them from mixing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different vortex penetration regimes have been registered in the output voltage signal of a magnetometer when single microwave pulses are applied to an epitaxial overdoped La2− x Sr x CuO4 thin film in a perpendicular dc magnetic field. The onset of a significant variation in the sample magnetization which exists below threshold values of temperature, dc magnetic field, and pulse duration is interpreted as an avalanche-type flux penetration. The microwave contribution to the background electric field suggests that the nucleation of this fast vortex motion is of electric origin, which also guarantees the occurrence of vortex instabilities under adiabatic conditions via the enhancement of the flux flow resistivity. Flux creep phenomena and heat transfer effects act as stabilizing factors against the microwave-pulse-induced fast flux diffusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methylene blue (MB) and light are used for virus inactivation of plasma for transfusion. However, the presence of MB has been the subject of concern, and efforts have been made to efficiently remove the dye after photo-treatment. For this study, plasma was collected by apheresis from 10 donors (group A), then treated using the MacoPharma THERAFLEX procedure (MB; 1 microM, and light exposure; 180 J/cm(2)) (group B), and finally filtered in order to remove the dye (group C). Proteins were analyzed by two-dimensional electrophoresis, and peptides showing modifications were characterized by mass spectrometry. Clottable and antigenic fibrinogen levels, as well as fibrin polymerization time were measured. Analyses of the gels focused on a region corresponding to pI between 4.5 and 6.5, and M(r) from 7000 to 58 000. In this area, 387 +/- 47 spots matched, and four of these spots presented significant modifications. They corresponded to changes of the gamma-chain of fibrinogen, of transthyretin, and of apolipoprotein A-I, respectively. A decrease of clottable fibrinogen and a prolongation of fibrin polymerization time were observed in groups B and C. Removal of MB by filtration was not responsible for additional protein alterations. The effect of over-treatment of plasma by very high concentrations of MB (50 microM) in association with prolonged light exposure (3 h) was also analyzed, and showed complex alterations of most of the plasma proteins, including fibrinogen gamma-chain, transthyretin, and apolipoprotein A-I. Our data indicates that MB treatment at high concentration and prolonged illumination severely injure plasma proteins. By contrast, at the MB concentration used to inactivate viruses, damages are apparently very restricted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

On yleisesti tiedossa, että väsyttävän kuormituksen alaisena olevat hitsatut rakenteet rikkoutuvat juuri hitsausliitoksista. Täyden tunkeuman hitsausliitoksia sisältävien rakenteiden asiantunteva suunnittelu janykyaikaiset valmistusmenetelmät ovat lähes eliminoineet väsymisvauriot hitsatuissa rakenteissa. Väsymislujuuden parantaminen tiukalla täyden tunkeuman vaatimuksella on kuitenkin epätaloudellinen ratkaisu. Täyden tunkeuman hitsausliitoksille asetettavien laatuvaatimuksien on määriteltävä selkeät tarkastusohjeet ja hylkäämisperusteet. Tämän diplomityön tarkoituksena oli tutkia geometristen muuttujien vaikutusta kuormaa kantavien hitsausliitosten väsymislujuuteen. Huomio kiinnitettiin pääasiassa suunnittelumuuttujiin, joilla on vaikutusta väsymisvaurioiden syntymiseen hitsauksen juuren puolella. Nykyiset määräykset ja standardit, jotka perustuvat kokeellisiin tuloksiin; antavat melko yleisiä ohjeita hitsausliitosten väsymismitoituksesta. Tämän vuoksi muodostettiin kokonaan uudet parametriset yhtälöt sallitun nimellisen jännityksen kynnysarvon vaihteluvälin, ¿¿th, laskemiseksi, jotta vältettäisiin hitsausliitosten juuren puoleiset väsymisvauriot. Lisäksi, jokaiselle liitostyypille laskettiin hitsin juuren puolen väsymisluokat (FAT), joita verrattiin olemassa olevilla mitoitusohjeilla saavutettuihin tuloksiin. Täydentäviksi referensseiksi suoritettiin useita kolmiulotteisia (3D) analyysejä. Julkaistuja kokeellisiin tuloksiin perustuvia tietoja käytettiin apuna hitsausliitosten väsymiskäyttäytymisen ymmärtämiseksi ja materiaalivakioiden määrittämiseksi. Kuormaa kantavien vajaatunkeumaisten hitsausliitosten väsymislujuus määritettiin käyttämällä elementtimenetelmää. Suurimman pääjännityksen kriteeriä hyödynnettiin murtumiskäyttäytymisen ennakoimiseksi. Valitulle hitsatulle materiaalille ja koeolosuhteille murtumiskäyttäytymistä mallinnettiin särön kasvunopeudella da/dN ja jännitysintensiteettikertoimen vaihteluvälillä, 'K. Paris:n yhtälön numeerinen integrointi suoritettiin FRANC2D/L tietokoneohjelmalla. Saatujen tulosten perusteella voidaan laskea FAT tutkittavassa tapauksessa. ¿¿th laskettiin alkusärön jännitysintensiteettikertoimen vaihteluvälin ja kynnysjännitysintensiteettikertoimen, 'Kth, perusteella. ¿Kth arvoa pienemmällä vaihteluvälillä särö ei kasva. Analyyseissäoletuksena oli hitsattu jälkikäsittelemätön liitos, jossa oli valmis alkusärö hitsin juuressa. Analyysien tulokset ovat hyödyllisiä suunnittelijoille, jotka tekevät päätöksiä koskien geometrisiä parametreja, joilla on vaikutusta hitsausliitosten väsymislujuuteen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this thesis is to study the mixing of fuel and, also to some extent, the mixing of air in a circulating fluidized bed boiler. In the literature survey part of this thesis, a review is made of the previous experimental studies related to the fuel and air mixing in the circulating fluidized beds. In the simulation part of it the commercial computational fluid dynamics software (FLUENT) is used with the Eulerian multiphase model for studying the fuel mixing in the two and three-dimensional furnace geometries. The results of the three-dimensional simulations are promising and, therefore suggestions are made for the future simulations. The two-dimensional studies give new information of the effects of the fluidization velocity, fuel particle size and fuel density on the fuel mixing. However, the present results show that three-dimensional models produce more realistic representation of the circulating fluidized bed behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monogamy and sex without penetration are behaviors recommended by the WHO to avoid AIDS virus sexual transmission. Seven hundred and fifty university students from 18 to 25 years (67.7% women) were surveyed and they were asked to give a maximum of three free definitions of the words monogamy and sex without penetration to prevent AIDS virus sexual transmission. Their participation was voluntary and anonymous. Although the majority of the answers was correct, there was a considerable percentage of wrong answers, either for monogamy (3.7% masturbation; 2.1% to have many partners; 0.9% homosexual relations), or for sex without penetration (20.5% oral sex; 1.1% anal coitus; 0.8% coitus without orgasm; 0.4% coitus interruptus). Some definitions or examples differ by gender. The amount of wrongs or incomplete answers put researchers on the alert about insufficient preventive knowledge in a population with a high educational level

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A chromatographic technique for determination of rutin and narcissin in marigold extract and topical formulations was developed and validated. The method shows linearity over the concentration range of 0.2 - 6.0 μg/mL of rutin (r = 0.9986) and 0.8 - 12.0 μg/mL of narcissin (r = 0.9951). The values obtained for precision and accuracy are in agreement with ICH guidelines. Both the formulation excipients and the porcine ear skin samples did not interfere with the flavonoids determination. The recovery of rutin and narcissin in skin samples added with marigold extract was 81.41% and 83.35%, respectively, which demonstrate the applicability of this method to perform skin penetration studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical performance of electrodeposited Ti/β-PbO2 and Ti-Pt/β-PbO2 anodes was galvanostatically evaluated (batch mode, 50 mA cm-2) to degrade the Direct Yellow 86 dye (100 or 200 mg L-1 in 0.1 mol L-1 Na2SO4 + 1.5 g L-1 NaCl), investigating the effect of pH and temperature. Similar results were obtained for both electrodes and the best conditions for removal of color and chemical oxygen demand are pH 7 and 40 °C, when 90% decolorization is attained by passing a charge of only ~0.13 A h L-1 and total mineralization is achieved with expenditure of ~5 kW h m-3.