920 resultados para Dispute settlement procedure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artificial neural networks have been used to analyze a number of engineering problems, including settlement caused by different tunneling methods in various types of ground mass. This paper focuses on settlement over shotcrete- supported tunnels on Sao Paulo subway line 2 (West Extension) that were excavated in Tertiary sediments using the sequential excavation method. The adjusted network is a good tool for predicting settlement above new tunnels to be excavated in similar conditions. The influence of network training parameters on the quality of results is also discussed. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper contains a new proposal for the definition of the fundamental operation of query under the Adaptive Formalism, one capable of locating functional nuclei from descriptions of their semantics. To demonstrate the method`s applicability, an implementation of the query procedure constrained to a specific class of devices is shown, and its asymptotic computational complexity is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A procedure to evaluate mine rehabilitation practices during the operational phase was developed and validated. It is based on a comparison of actually observed or documented practices with internationally recommended best practices (BP). A set of 150 BP statements was derived from international guides in order to establish the benchmark. The statements are arranged in six rehabilitation programs under three categories: (1) planning (2) operational and (3) management, corresponding to the adoption of the plan-do-check-act management systems model to mine rehabilitation. The procedure consists of (i) performing technical inspections guided by a series of field forms containing BP statements; (ii) classifying evidences in five categories; and (iii) calculating conformity indexes and levels. For testing and calibration purposes, the procedure was applied to nine limestone quarries and conformity indexes were calculated for the rehabilitation programs in each quarry. Most quarries featured poor planning practices, operational practices reached high conformity levels in 50% of the cases and management practices scored moderate conformity. Despite all quarries being ISO 14001 certified, their management systems pay low attention to issues pertaining to land rehabilitation and biodiversity. The best results were achieved by a quarry whose expansion was recently submitted to the environmental impact assessment process, suggesting that public scrutiny may play a positive role in enhancing rehabilitation practices. Conformity indexes and levels can be used to chart the evolution of rehabilitation practices at regular intervals, to establish corporate goals and for communication with stakeholders. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work examines the effect of weld strength mismatch on fracture toughness measurements defined by J and CTOD fracture parameters using single edge notch bend (SE(B)) specimens. A central objective of the present study is to enlarge on previous developments of J and CTOD estimation procedures for welded bend specimens based upon plastic eta factors (eta) and plastic rotational factors (r (p) ). Very detailed non-linear finite element analyses for plane-strain models of standard SE(B) fracture specimens with a notch located at the center of square groove welds and in the heat affected zone provide the evolution of load with increased crack mouth opening displacement required for the estimation procedure. One key result emerging from the analyses is that levels of weld strength mismatch within the range +/- 20% mismatch do not affect significantly J and CTOD estimation expressions applicable to homogeneous materials, particularly for deeply cracked fracture specimens with relatively large weld grooves. The present study provides additional understanding on the effect of weld strength mismatch on J and CTOD toughness measurements while, at the same time, adding a fairly extensive body of results to determine parameters J and CTOD for different materials using bend specimens with varying geometries and mismatch levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Over the years, crop insurance programs became the focus of agricultural policy in the USA, Spain, Mexico, and more recently in Brazil. Given the increasing interest in insurance, accurate calculation of the premium rate is of great importance. We address the crop-yield distribution issue and its implications in pricing an insurance contract considering the dynamic structure of the data and incorporating the spatial correlation in the Hierarchical Bayesian framework. Results show that empirical (insurers) rates are higher in low risk areas and lower in high risk areas. Such methodological improvement is primarily important in situations of limited data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective was to develop and test a procedure for applying variable rates of fertilizers and evaluate yield response in coffee (Coffea arabica L.) with regard to the application of phosphorus and potassium. The work was conducted during the 2004 season in a 6.4 ha field located in central Sao Paulo state. Two treatments were applied with alternating strips of fixed and variable rates during the whole season: one following the fertilizing procedures recommended locally, and the other based on a grid soil sampling. A prototype pneumatic fertilizer applicator was used, carrying two conveyor belts, one for each row. Harvesting was done with a commercial harvester equipped with a customized volumetric yield monitor, separating the two treatments. Data were analyzed based on geostatistics, correlations and regressions. The procedure showed to be feasible and effective. The area that received fertilizer applications at a variable rate showed a 34% yield increase compared to the area that received a fixed rate. The variable rate fertilizer resulted in a savings of 23% in phosphate fertilizer and a 13% increase in potassium fertilizer, when compared to fixed rate fertilizer. Yield in 2005, the year after the variable rate treatments, still presented residual effect from treatments carried out during the previous cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Seroprevalence of Toxocara and Taenia solium and risk factors for infection with these parasites were explored in a long-term rural settlement in Sao Paula state, Brazil. An ELISA for the detection of anti-Toxocara IgG and IgE and anti-T. solium cysticerci was standardized using Toxocara excretory-secretory antigens (TES) obtained from the cultured second-stage larvae of T. canis and by vesicular fluid antigen from Taenia crassiceps cysticerci (VC). For cysticercosis, the reactive ELISA samples were assayed by Western blot using 18 kDa and 14 kDa proteins purified from VF. Out of 182 subjects, 25 (13.7%,) presented anti-Toxocora IgG and it positive correlation between total IgE and the reactive index of specific anti-TES IgE (P=0.0265) was found amongst the subjects found seropositive for anti-Toxocara IgG. In these individuals 38.0%. showed ocular manifestations. The frequency of anti-T. solium cysticerci confirmed by Western blot wits 0.6%, Seropositivity for Toxocara was correlated with low educational levels and the owning of dogs. Embryonated eggs of Toxocara spp. were found in 43.3% of the analysed areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The seroprevalence of Toxocara canis and risk factors for infection with this parasite were explored in a rural settlement in Sao Paulo state, Brazil. Total IgA and IgE levels in 79 subjects were determined by turbidimetry and chemiluminescence, respectively. Total counts of leucocytes and erythrocytes and differential counts of leucocytes were made by flow cytometry. ELISA for the detection of anti-Toxocara IgG, IgA and IgE were standardized using Toxocara excretory-secretory antigens (TES) obtained from the cultured second-stage larvae of T. canis. Seventeen (21.5%) of the subjects were found positive for anti-Toxocara IgG, with no significant differences in such seropositivity with age or gender. Thirty (38%) of the subjects showed eosinophilia and 70 (89%) had elevated levels of total IgE. Among the 17 subjects found seropositive for anti-Toxocara IgG, the percentage of leucocytes represented by eosinophils (P=0.0069) and total levels of IgE (P=0.0452) were positively correlated with the levels of anti-TES IgE. Although anti-TES IgA was detected in 10 (59%) of the subjects, there was no significant correlation between the levels of total IgA and those of Toxocara-specific IgA. Only one of the 17 subjects found positive for anti-Toxocara IgG had attended a secondary school and all but two belonged to households with monthly incomes of < U.S.$100. In the study community at least, seropositivity may be related to poor living standards and lack of basic sanitary conditions. The presence of anti-Toxocara IgE and IgA may facilitate the diagnosis of toxocariasis and may well be useful for monitoring the success of treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite the necessity to differentiate chemical species of mercury in clinical specimens, there area limited number of methods for this purpose. Then, this paper describes a simple method for the determination of methylmercury and inorganic mercury in blood by using liquid chromatography with inductively coupled mass spectrometry (LC-ICP-MS) and a fast sample preparation procedure. Prior to analysis, blood (250 mu L) is accurately weighed into 15-mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCI was added to the samples following sonication for 15 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of mercury species was accomplished in less than 5 min on a C18 reverse-phase column with a mobile phase containing 0.05% (v/v) mercaptoethanol, 0.4% (m/v) L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% (v/v) methanol. The method detection limits were found to be 0.25 mu g L(-1) and 0.1 mu Lg L(-1) for inorganic mercury and methylmercury, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). The proposed method was also applied to the speciation of mercury in blood samples collected from fish-eating communities and from rats exposed to thimerosal. With the proposed method there is a considerable reduction of the time of sample preparation prior to speciation of Hg by LC-ICP-MS. Finally, after the application of the proposed method, we demonstrated an interesting in vivo ethylmercury conversion to inorganic mercury. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple method for mercury speciation in hair samples with a fast sample preparation procedure using high-performance liquid chromatography coupled to inductively coupled plasma mass spectrometry is proposed. Prior to analysis, 50 mg of hair samples were accurately weighed into 15 mL conical tubes. Then, an extractant solution containing mercaptoethanol, L-cysteine and HCl was added to the samples following sonication for 10 min. Quantitative mercury extraction was achieved with the proposed procedure. Separation of inorganic mercury (Ino-Hg), methylmercury (Met-Hg) and ethylmercury (Et-Hg) was accomplished in less than 8 min on a C18 reverse phase column with a mobile phase containing 0.05% v/v mercaptoethanol, 0.4% m/v L-cysteine, 0.06 mol L(-1) ammonium acetate and 5% v/v methanol. The method detection limits were found to be 15 ng g(-1), 10 ng g(-1) and 38 ng g(-1), for inorganic mercury, methylmercury and ethylmercury, respectively. Sample throughput is 4 samples h(-1) (duplicate). A considerable improvement in the time of analysis was achieved when compared to other published methods. Method accuracy is traceable to Certified Reference Materials (CRMs) 85 and 86 human hair from the International Atomic Energy Agency (IAEA). Finally, the proposed method was successfully applied to the speciation of mercury in hair samples collected from fish-eating communities of the Brazilian Amazon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple method for mercury speciation in seafood samples by LC-ICP-MS with a fast sample preparation procedure. Prior to analysis, mercury species were extracted from food samples with a solution containing mercaptoethanol, L-cysteine and HCl and sonication for 15 min. Separation of mercury species was accomplished in less than 5 min on a C8 reverse phase column with a mobile phase containing 0.05%-v/v mercaptoethanol, 0.4% m/v L-cysteine and 0.06 mol L(-1) ammonium acetate. The method detection limits were found to be 0.25, 0.20 and 0.1 ng g(-1) for inorganic mercury, ethylmercury and methylmercury, respectively. Method accuracy is traceable to Certified Reference Materials (DOLT-3 and DORM-3) from the National Research Council Canada (NRCC). With the proposed method there is a considerable reduction of the time of sample preparation. Finally, the method was applied for the speciation of mercury in seafood samples purchased from the Brazilian market. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method is described for simultaneous determination of methylmercury (MeHg), ethylmercury (Et-Hg) and inorganic mercury (Ino-Hg) in blood samples by using capillary gas chromatography-inductively coupled plasma mass spectrometry (GC-ICP-MS) after derivatization and alkaline digestion. Closed-vessel microwave assisted digestion conditions with tetramethylammonium hydroxide (TMAH) have been optimized. Derivatization by using ethylation and propylation procedures have also been evaluated and compared. The absolute detection limits (using a 1 mu L injection) obtained by GC-ICP-MS with ethylation were 40 fg for MeHg and Ino-Hg, respectively, and with propylation were 50, 20 and 50 fg for MeHg, Et-Hg and Ino-Hg, respectively. Method accuracy is traceable to Standard Reference Material (SRM) 966 Toxic Metals in Bovine Blood from the National Institute of Standards and Technology (NIST). Additional validation is provided based on the comparison of results obtained for mercury speciation in blood samples with the proposed procedure and with a previously reported LC-ICP-MS method. With the new proposed procedure no tedious clean-up steps are required and a considerable improvement of the time of analysis was achieved compared to other methods using GC separation.

Relevância:

20.00% 20.00%

Publicador: