938 resultados para DOPPLER ULTRASOUND


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: This study aimed to evaluate the characteristics of the brain and vascular indicesof the middle cerebral artery of canine foetuses. Methods: Twenty-five bitches were selected. Tissue development, echogenicity, echotexture and brain echobiometric data were studied, and the major structures were identified between the 5th and 8th gestational weeks. The area and volume of the brain mass (BMA and BMV), cranial area and volume (AC and VC), brain mass index (BMI) and brain volume index (BVI) were determined. A single ultrasound examination was performed during each studied week (6th, 7th and 8th). Doppler ultrasonography was performed to assess the maximum and minimum velocity, resistance and pulsatility index of middle cerebral artery of the foetuses. Results: Echoencephalography was performed to evaluate the morphological characteristics of the central nervous system. Cerebral echobiometry indicated an increase in area and volume of the hemispheres and cranium (P<0·001) but no changes in BMI or BVI over the gestational period studied. Doppler ultrasonography identified increases in peak systolic velocity (P=0·0188) and end diastolic velocity (P=0·0274) and decreases in resistance index (P=0·0002) and pulsatility index (P<0·001). Clinical Significance: Echoencephalography and spectral Doppler ultrasonography of the middle cerebral artery in canine foetuses might be a useful technique for prenatal care. © 2013 British Small Animal Veterinary Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve como objetivo descrever as características ultrassonográficas uterinas e ovarianas, e dopplervelocimétricas das suas artérias nos dias periovulatórios em cadelas. Quinze ciclos estrais em 10 animais foram avaliados. As características ultrassonográficas, índices de resistência (IR) e índices de pulsatilidade (IP) do útero e dos ovários em cada animal foram registrados 5 dias antes e depois da ovulação (D0). Os dados foram analisados estatisticamente e os resultados foram expressos em média ± erro padrão da média (P<0,05). Como resultados as características ultrassonográficas uterinas foram semelhantes em todos os ciclos e dias avaliados, tendo o corpo uterino um diâmetro médio de 0,85±0,02cm. Foi observado um aumento no volume dos ovários e nos diâmetros dos folículos, tendo os ovários um volume de 0,64±0,06cm3, e a cavidade dos folículos um diâmetro de 0,46±0,01cm no dia da ovulação. Após a ovulação, foi observado colapso dos folículos somente em alguns ciclos. A perfusão sanguínea uterina diminuiu dois dias antes da ovulação e permaneceu inalterada até a ovulação. Após a ovulação, houve um aumento gradual na perfusão das artérias uterinas e ovarianas, direcionando o fluxo de sangue para os ovários e aumentando a perfusão da artéria intra-ovariana um dia após a ovulação. Conclui-se que características específicas são observadas na imagem ultrassonográfica uterina e ovariana, e dopplervelocimétricas de suas artérias nos dias periovulatórios, e quando associadas permitem estimar com mais precisão o dia da ovulação.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo do trabalho foi estabelecer a relação entre a ecobiometria renal com medidas de conformação corporal como a distância atlanto-coccígea (DAC) e a altura (H) de cães adultos saudáveis, obtendo-se parâmetros de normalidade para avaliar o tamanho e volume renal, bem como estabelecer valores de referência para avaliar a perfusão sanguínea dos rins por meio do índice de resistividade (IR) e do índice de pulsatilidade (IP) do ramo principal da artéria renal. No estudo foram utilizados 22 cães adultos sem raça definida, sendo 11 machos e 11 fêmeas. Os animais foram previamente aferidos quanto a DAC e a H. Os exames ultra-sonográficos foram realizados com um aparelho HDI 4000 PHILIPS munido de um transdutor microconvexo multifreqüêncial (5-8 MHz), dispositivos Doppler Colorido e Doppler de Fluxo. Os animais foram posicionados em decúbito lateral direito ou esquerdo, de acordo com o rim a ser avaliado. Os diâmetros longitudinal (DL) e dorsoventral (DDV) dos rins foram mensurados na secção longitudinal e, o diâmetro transversal (DT) foi aferido no plano transversal. O volume (V) foi calculado automaticamente pelo software do ultra-som. Com o uso do Triplex Doppler, o IR e o IP das artérias renais direita e esquerda foram obtidos. Todos os dados foram apresentados em média ± EPM. Análises de regressão linear foram realizadas tendo o DL, DDV, DT e V como variáveis dependentes e a DAC e H como variáveis independentes. Os IR e IP dos rins direito e esquerdo foram comparados pelo teste t de Student. A DAC variou de 54-78cm para machos e 37-71cm para fêmeas e a altura variou entre 34-64 cm para os machos e 24-57cm para as fêmeas. As médias obtidas para DL, DDV, DT e V dos rins esquerdo e direito foram: 5,24±0,27cm, 3,07±0,15cm, 3,07±0,9cm, 28,01±3,4mL e 4,50±0,19cm, 2,88±0,14cm, 2,71±0,15cm, 21,27±2,6mL, respectivamente. As análises de regressão linear entre as medidas lineares e volume renal com a DAC e a H foram significativas para os interceptos e coeficientes de regressão (P<0,01). Houve diferenças estatísticas quando comparado os IR e IP entre os rins direito e esquerdo (P=0,001), sendo que as médias para IR e IP dos rins esquerdo e direito foram 0,62±0,08; 1,34±0,18 e 0,70±0,06; 1,62±0,13; respectivamente. Os dados obtidos no presente trabalho podem auxiliar na avaliação do tamanho, volume e perfusão dos rins de cães adultos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar, por meio da ultrassonografia convencional modo B, as características sonográficas e a biometria dos rins de fetos caninos, bem como determinar os índices vasculares da artéria renal dos conceptos ao Doppler Triplex. Foram utilizadas 24 fêmeas Shi-tzu e Pugs pesando de quatro a 10 kg e com idade entre quatro e seis anos. Ao modo B, a ecobiometria renal fetal, a regularidade da superfície renal, a ecotextura e a relação córtico-medular foram avaliadas durante a quinta, sexta, sétima e oitava semanas gestacionais. Ao Doppler Triplex, durante o mesmo período em que se realizou o exame convencional, foram determinados o pico de velocidade sistólica (PVS), a velocidade diastólica final (EDV) e o índice de resistência vascular (RI) e de pulsatividade (PI). Ao modo B, não foram detectadas alterações em rins fetais, e à ecobiometria renal dos fetos, foi possível determinar medidas renais importantes, verificando-se aumento das biometrias no decorrer do desenvolvimento fetal (P<0,0001). Ao Doppler Triplex, determinaram-se os índices vasculares da artéria renal fetal, sendo que os valores para PSV e EDV aumentaram no decorrer das semanas gestacionais (P<0,05) e permaneceram constantes para PI e RI (P>0,05). Concluiu-se que o modo B e o Doppler Triplex são ferramentas importantes para a avaliação do desenvolvimento renal fetal, com a utilização da ecobiometria renal e avaliação dos indices vasculares da artéria renal de fetos caninos.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

No safe ultrasound (US) parameters have been established to differentiate the causes of graft dysfunction.To define US parameters and identify the predictors of normal graft evolution, delayed graft function (DGF), and rejection at the early period after kidney transplantation.Between June 2012 and August 2013, 79 renal transplant recipients underwent US examination 1-3 days posttransplantation. Resistive index (RI), power Doppler (PD), and RI + PD (quantified PD) were assessed. Patients were allocated into three groups: normal graft evolution, DGF, and rejection.Resistive index of upper and middle segments and PD were higher in the DGF group than in the normal group. ROC curve analysis revealed that RI + PD was the index that best correlated with DGF (cutoff = 0.84). In the high RI + PD group, time to renal function recovery (6.33 +/- A 6.5 days) and number of dialysis sessions (2.81 +/- A 2.8) were greater than in the low RI + PD group (2.11 +/- A 5.3 days and 0.69 +/- A 1.5 sessions, respectively), p = 0.0001. Multivariate analysis showed that high donor final creatinine with a relative risk (RR) of 19.7 (2.01-184.7, p = 0.009) and older donor age (RR = 1.17 (1.04-1.32), p = 0.007) correlated with risk DGF.Quantified PD (RI + PD) was the best DGF predictor. PD quantification has not been previously reported .

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12 +/- 0.01 mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1: 1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39 +/- 0.05 mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34 +/- 0.03 mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2 mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60 +/- 0.32 cm/s; EDV: 6.96 +/- 1.68cm/s; PI: 1.15 +/- 0.07 e RI: 0.73 +/- 0.07) and right (PSV: 23.08 +/- 3.34cm/s; EDV: 9.33 +/- 2.36cm/s; PI: 1.01 +/- 0.65 e RI: 0.65 +/- 0.16) and left renal arteries (PSV: 23.74 +/- 3.94cm/s; EDV: 9.07 +/- 3.02cm/s; PI: 1.04 +/- 0.31 e RI: 0.64 +/- 0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to relate the presence of a temporal acoustic window (TAW) to the variables sex, age and race. This observational study was conducted in patients under etiologic investigation after stroke, sickle-cell anemia and hospitalization in an intensive therapy neurologic unit. TAW presence was confirmed by bilateral assessment by two neurologists via transcranial Doppler (TCD). Multiple logistic regression was performed to explain the presence of the window as a function of sex, age and race. In 20% of the 262 patients evaluated, a TAW was not present. The incidence of TAW presence was greater in men (odds ratio [OR] = 5.4, 95% confidence interval [CI] = 2.5-11.7, p < 0.01); lower with increased age (OR = 0.9, 95% CI = 0.92-0.97, p < 0.01); and lower among those of African and Asian descent (OR = 0.32, 95% CI = 0.14-0.70, p = 0.005). On the basis of the results, more men than women had TAWs, and the decrease in TAWs was associated with increased age and African or Asian descent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate the intra- and interobserver reliability of assessment of three-dimensional power Doppler (3D-PD) indices from single spherical samples of the placenta. Methods Women with singleton pregnancies at 2440 weeks' gestation were included. Three scans were independently performed by two observers; Observer 1 performed the first and third scan, intercalated by the scan of Observer 2. The observers independently analyzed the 3D-PD datasets that they had previously acquired using four different methods, each using a spherical sample: random sample extending from basal to chorionic plate; random sample with 2 cm3 of volume; directed sample to the region subjectively determined as containing more color Doppler signals extending from basal to chorionic plate; or directed sample with 2 cm3 of volume. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) were evaluated in each case. The observers were blinded to their own and each other's results. Additional evaluation was performed according to placental location: anterior, posterior and fundal or lateral. Intra- and interobserver reliability was assessed by intraclass correlation coefficients (ICC). Results Ninety-five pregnancies were included in the analysis. All three placental 3D-PD indices showed only weak to moderate reliability (ICC < 0.66 and ICC < 0.48, intra- and interobserver, respectively). The highest values of ICC were observed when using directed spherical samples from basal to chorionic plate. When analyzed by placental location, we found lower ICCs for lateral and fundal placentae compared to anterior and posterior ones. Conclusion Intra- and interobserver reliability of assessment of placental 3D-PD indices from single spherical samples in pregnant women greater than 24 weeks' gestation is poor to moderate, and clinical usefulness of these indices is likely to be limited. Copyright (c) 2012 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives To evaluate the accuracy and probabilities of different fetal ultrasound parameters to predict neonatal outcome in isolated congenital diaphragmatic hernia (CDH). Methods Between January 2004 and December 2010, we evaluated prospectively 108 fetuses with isolated CDH (82 left-sided and 26 right-sided). The following parameters were evaluated: gestational age at diagnosis, side of the diaphragmatic defect, presence of polyhydramnios, presence of liver herniated into the fetal thorax (liver-up), lung-to-head ratio (LHR) and observed/expected LHR (o/e-LHR), observed/expected contralateral and total fetal lung volume (o/e-ContFLV and o/e-TotFLV) ratios, ultrasonographic fetal lung volume/fetal weight ratio (US-FLW), observed/expected contralateral and main pulmonary artery diameter (o/e-ContPA and o/eMPA) ratios and the contralateral vascularization index (Cont-VI). The outcomes were neonatal death and severe postnatal pulmonary arterial hypertension (PAH). Results Neonatal mortality was 64.8% (70/108). Severe PAH was diagnosed in 68 (63.0%) cases, of which 63 died neonatally (92.6%) (P < 0.001). Gestational age at diagnosis, side of the defect and polyhydramnios were not associated with poor outcome (P > 0.05). LHR, o/eLHR, liver-up, o/e-ContFLV, o/e-TotFLV, US-FLW, o/eContPA, o/e-MPA and Cont-VI were associated with both neonatal death and severe postnatal PAH (P < 0.001). Receiver-operating characteristics curves indicated that measuring total lung volumes (o/e-TotFLV and US-FLW) was more accurate than was considering only the contralateral lung sizes (LHR, o/e-LHR and o/e-ContFLV; P < 0.05), and Cont-VI was the most accurate ultrasound parameter to predict neonatal death and severe PAH (P < 0.001). Conclusions Evaluating total lung volumes is more accurate than is measuring only the contralateral lung size. Evaluating pulmonary vascularization (Cont-VI) is the most accurate predictor of neonatal outcome. Estimating the probability of survival and severe PAH allows classification of cases according to prognosis. Copyright (C) 2011 ISUOG. Published by John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background Hand-carried ultrasound (HCU) devices have been demonstrated to improve the diagnosis of cardiac diseases over physical examination, and have the potential to broaden the versatility in ultrasound application. The role of these devices in the assessment of hospitalized patients is not completely established. In this study we sought to perform a direct comparison between bedside evaluation using HCU and comprehensive echocardiography (CE), in cardiology inpatient setting. Methods We studied 44 consecutive patients (mean age 54 ± 18 years, 25 men) who underwent bedside echocardiography using HCU and CE. HCU was performed by a cardiologist with level-2 training in the performance and interpretation of echocardiography, using two-dimensional imaging, color Doppler, and simple calliper measurements. CE was performed by an experienced echocardiographer (level-3 training) and considered as the gold standard. Results There were no significant differences in cardiac chamber dimensions and left ventricular ejection fraction determined by the two techniques. The agreement between HCU and CE for the detection of segmental wall motion abnormalities was 83% (Kappa = 0.58). There was good agreement for detecting significant mitral valve regurgitation (Kappa = 0.85), aortic regurgitation (kappa = 0.89), and tricuspid regurgitation (Kappa = 0.74). A complete evaluation of patients with stenotic and prosthetic dysfunctional valves, as well as pulmonary hypertension, was not possible using HCU due to its technical limitations in determining hemodynamic parameters. Conclusion Bedside evaluation using HCU is helpful for assessing cardiac chamber dimensions, left ventricular global and segmental function, and significant valvular regurgitation. However, it has limitations regarding hemodynamic assessment, an important issue in the cardiology inpatient setting.