989 resultados para Corneal biomechanical properties
Resumo:
The human amniotic membrane (AM) is a tissue of fetal origin and has proven to be clinically useful as a biomaterial in the management of various ocular surface disorders including corneal stem cell transplantation. However, its success rate displays a degree of clinical unpredictability. We suggest that the measured variability inAMstiffness offers an explanation for the poor clinical reproducibility when it is used as a substrate for stem cell expansion and transplantation. Corneal epithelial stem cells were expanded upon AM samples possessing different mechanical stiffness. To investigate further the importance of biological substrate stiffness on cell phenotype we replaced AM with type I collagen gels of known stiffness. Substrate stiffness was measured using shear rheometry and surface topography was characterized using scanning electron microscopy and atomic force microscopy. The differentiation status of epithelial cells was examined using RT-PCR, immunohistochemistry and Western blotting. The level of corneal stem cell differentiation was increased in cells expanded upon AM with a high dynamic elastic shear modulus and cell expansion on type I collagen gels confirmed that the level of corneal epithelial stem cell differentiation was related to the substrate’s mechanical properties. In this paper we provide evidence to show that the preparatory method of AM for clinical use can affect its mechanical properties and that these measured differences can influence the level of differentiation within expanded corneal epithelial stem cells.
Resumo:
Overcoming the natural defensive barrier functions of the eye remains one of the greatest challenges of ocular drug delivery. Cornea is a chemical and mechanical barrier preventing the passage of any foreign bodies including drugs into the eye, but the factors limiting penetration of permeants and nanoparticulate drug delivery systems through the cornea are still not fully understood. In this study, we investigate these barrier properties of the cornea using thiolated and PEGylated (750 and 5000 Da) nanoparticles, sodium fluorescein, and two linear polymers (dextran and polyethylene glycol). Experiments used intact bovine cornea in addition to bovine cornea de-epithelialized or tissues pretreated with cyclodextrin. It was shown that corneal epithelium is the major barrier for permeation; pretreatment of the cornea with β-cyclodextrin provides higher permeation of low molecular weight compounds, such as sodium fluorescein, but does not enhance penetration of nanoparticles and larger molecules. Studying penetration of thiolated and PEGylated (750 and 5000 Da) nanoparticles into the de-epithelialized ocular tissue revealed that interactions between corneal surface and thiol groups of nanoparticles were more significant determinants of penetration than particle size (for the sizes used here). PEGylation with polyethylene glycol of a higher molecular weight (5000 Da) allows penetration of nanoparticles into the stroma, which proceeds gradually, after an initial 1 h lag phase.
Resumo:
Purpose: To evaluate the biomechanical fixation, bone-to-implant contact (BIC), and bone morphology of screw-type root-form implants with healing chambers with as-machined or dual acid-etched (DAE) surfaces in a canine model. Materials and Methods: The animal model included the placement of machined (n = 24) and DAE (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Following euthanasia, half of the specimens were subjected to biomechanical testing (torque to interface failure) and the other half were processed for histomorphologic and histomorphometric (%BIC) assessments. Statistical analyses were performed by one-way analysis of variance at the 95% confidence level and the Tukey post hoc test for multiple comparisons. Results: At 4 weeks, the DAE surface presented significantly higher mean values for torque to interface failure overall. A significant increase in %BIC values occurred for both groups over time. For both groups, bone formation through the classic appositional healing pathway was observed in regions where intimate contact between the implant and the osteotomy walls occurred immediately after implantation. Where contact-free spaces existed after implantation (healing chambers), an intramembranous-like healing mode with newly formed woven bone prevailed. Conclusions: In the present short-term evaluation, no differences were observed in BIC between groups; however, an increase in biomechanical fixation was seen from 2 to 4 weeks with the DAE surface. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:75-82
Resumo:
OBJETIVO: avaliar a influência do alcoolismo crônico experimental na morfologia e biomecânica da artéria aorta de ratos. MÉTODOS:ratos Wistar foram divididos em dois grupos de 22 animais. Grupo alcoolista: os ratos receberam água com concentração crescente de etanol e ração ad libitum durante 6 meses. Grupo controle: os animais receberam água e ração ad libitum pelo mesmo período. Os animais foram sacrificados com overdose de pentobarbital e as aortas abdominais foram excisadas para realização de histologia (hematoxilina-eosina, tricrômio de Masson, Calleja, Picrosirius red), histomorfometria e avaliação biomecânica (carga máxima, alongamento na carga máxima, limite de proporcionalidade, alongamento no limite de proporcionalidade e coeficiente de rigidez). RESULTADOS: A histologia e a histomorfometria não mostraram diferenças significantes na morfologia da aorta em ambos os grupos. A avaliação biomecânica mostrou aumento do alongamento no limite de proporcionalidade no grupo alcoolista (p<0.05). CONCLUSÃO: o alcoolismo crônico experimental não provocou alterações morfológicas na parede da aorta, mas causou aumento da sua elasticidade, sem modificar as outras propriedades mecânicas avaliadas.
Resumo:
The purpose of the present study was to evaluate, using a biomechanical test, the force needed to remove implants with surface modification by laser (Nd:YAG) in comparison with implants with machined surfaces. Twenty-four rabbits received one implant with each surface treatment in the tibia, machined surface (MS) and laser-modified surface (LMS). After 4, 8 and 12 weeks of healing, the removal torque was measured by a torque gauge. The surfaces studied were analyzed according to their topography, chemical composition and roughness. The average removal torque in each period was 23.28, 24.0 and 33.85 Ncm for MS, and 33.0, 39.87 and 54.57 Ncm for LMS, respectively. The difference between the surfaces in all periods of evaluation was statistically significant (p < 0.05). Surface characterization showed that a deep and regular topography was provided by the laser conditioning, with a great quantity of oxygen ions when compared to the MS. The surface micro-topography analysis showed a statistical difference (p < 0.01) between the roughness of the LMS (R a = 1.38 ± 0.23 μm) when compared to that of the MS (R a = 0.33 ± 0.06 μm). Based on these results, it was possible to conclude that the LMS implants' physical-chemical properties increased bone-implant interaction when compared to the MS implants. © 2009 Sociedade Brasileira de Pesquisa Odontológica.
Resumo:
The purpose of this study was to evaluate commercially pure titanium implant surfaces modified by laser beam (LS) and LS associated with sodium silicate (SS) deposition, and compare them with machined surface (MS) and dual acid-etching surfaces (AS) modified. Topographic characterization was performed by scanning electron microscopy-X-ray energy dispersive spectroscopy (SEM-EDX), and by mean roughness measurement before surgery. Thirty rabbits received 60 implants in their right and left tibias. One implant of each surface in each tibia. The implants were removed by reverse torque for vivo biomechanical analysis at 30, 60, and 90 days postoperative. In addition, the surface of the implants removed at 30 days postoperative was analyzed by SEM-EDX. The topographic characterization showed differences between the analyzed surfaces, and the mean roughness values of LS and SS were statistically higher than AS and MS. At 30 days, values removal torque LS and SS groups showed a statistically significant difference (p < 0.05) when compared with MS and AS. At 60 days, groups LS and SS showed statistically significant difference (p < 0.05) when compared with MS. At 90 days, only group SS presented statistically higher (p < 0.05) in comparison with MS. The authors can conclude that physical chemistry properties and topographical of LS and SS implants increases bone-implant interaction and provides higher degree of osseointegration when compared with MS and AS. © 2012 Wiley Periodicals, Inc.
Resumo:
Background: Smoking is the most relevant environmental factor that affects the development of aortic aneurysm. Smokers have elevated levels of elastase activity in the arterial wall, which leads to weakening of the aorta. The aim of this study was to verify whether cigarette smoke exposure itself is capable of altering the aortic wall. Methods: Forty-eight Wistar rats were divided into 2-, 4-, and 6-month experimental periods and into 2 groups: smokers (submitted to smoke exposure at a rate of 40 cigarettes/day) and nonsmokers. At the end of the experimental periods, the aortas were removed and cross-sectioned to obtain histologic specimens for light microscopic and morphometric analyses. The remaining longitudinal segments were stretched to rupture and mechanical parameters were determined. Results: A degenerative process (i.e., a reduction in elastic fibers, the loss of lamellar arrangement, and a reduction of smooth muscle cells) was observed, and this effect was proportional in intensity to the period of tobacco exposure. We observed a progressive reduction in the yield point of the thoracic aorta over time (P < 0.05). There was a decrease in stiffness (P < 0.05) and in failure load (P < 0.05) at 6 months in the abdominal aorta of rats in the smoking group. Conclusions: Chronic exposure to tobacco smoke can affect the mechanical properties of the aorta and can also provoke substantial structural changes of the arterial wall. © 2013 Elsevier Inc. All rights reserved.
Resumo:
Objectives: The purpose of this study was to evaluate the surfaces of commercially pure titanium (cp Ti) implants modified by laser beam (LS), without and with hydroxyapatite deposition by the biomimetic method (HAB), without (HAB) and with thermal treatment (HABT), and compare them with implants with surfaces modified by acid treatment (AS) and with machined surfaces (MS), employing topographical and biomechanics analysis. Methods: Forty-five rabbits received 75 implants. After 30, 60, and 90 days, the implants were removed by reverse torque and the surfaces were topographically analyzed. Results: At 30 days, statistically significant difference (P < 0.05) was observed among all the surfaces and the MS, between HAB/HABT and AS and between HAB and LS. At 60 days, the reverse torque of LS, HAB, HABT, and AS differed significantly from MS. At 90 days, difference was observed between HAB and MS. The microtopographic analysis revealed statistical difference between the roughness of LS, HAB, and HABT when compared with AS and MS. Conclusions: It was concluded that the implants LS, HAB, and HABT presented physicochemical and topographical properties superior to those of AS and MS and favored the osseointegration process in the shorter periods. In addition, HAB showed the best results when compared with other surfaces. © 2012 John Wiley & Sons A/S.
Resumo:
This study evaluated 3 implant surfaces in a dog model: (1) resorbable-blasting media + acid-etched (RBMa), alumina-blasting + acid-etching (AB/AE), and AB/AE + RBMa (hybrid). All of the surfaces were minimally rough, and Ca and P were present for the RBMa and hybrid surfaces. Following 2 weeks in vivo, no significant differences were observed for torque, bone-to-implant contact, and bone-area fraction occupied measurements. Newly formed woven bone was observed in proximity with all surfaces.
Resumo:
Several treatments have been developed aiming the prevention of bone loss. There are discussions about the best prophylactic and therapeutic procedures for osteoporosis. This study evaluated the effects of physical exercise associated with risedronate as a prophylactic and therapeutic procedure in osteopenic bones of rats submitted to ovariectomy. We used 48 Wistar rats divided into: ovariectomized or subjected to sham surgery. Ovariectomized rats were divided into the following sub-groups: OVX, 12 weeks sedentary; OVX-EX, treadmill training for 12 weeks; OVX-RA, 12 weeks with risedronate administration; and OVX-EX-RA, 12 weeks with risedronate administration and treadmill training. Rats subjected to sham surgery were divided into the following sub-groups: SH, 12 weeks sedentary; SH-EX, treadmill training for 12 weeks; SH-RA, 12 weeks with risedronate administration; and SH-EX-RA, 12 weeks with risedronate administration and training on the treadmill. The effectiveness of the treatment was evaluated in tibias using biomechanical, radiological, histomorphometric, and immunohistochemical analyses. Data were analyzed by statistical tests, with significance level of P < 0.05. Results of mechanical tests showed that the SH-RA group had lower values compared with OVX-RA group; densitometry showed no significant differences; according to histomorphometric methods, OVX group presented lower results than the SH-EX, OVX-RA, SH-EX-RA, and OVX-EX-RA groups, and SH-EX-RA and OVX-EX-RA groups showed values higher than SH-RA, SH, and OVX-EX groups. The SH-EX-RA and OVX-EX-RA groups had decreased immunostaining for tartrate-resistant acid phosphatase and receptor activator of nuclear factor kappa-B ligand and increased osteoprotegerin immunostaining. In this experimental model, it was concluded that the physical training associated with use of risedronate exerted positive effects on biomechanical and microstructural properties in bones of ovariectomized rats. (C) 2014 Wiley Periodicals, Inc.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Smoking is the most relevant environmental factor that affects the development of aortic aneurysm. Smokers have elevated levels of elastase activity in the arterial wall, which leads to weakening of the aorta. The aim of this study was to verify whether cigarette smoke exposure itself is capable of altering the aortic wall. Methods: Forty-eight Wistar rats were divided into 2-, 4-, and 6-month experimental periods and into 2 groups: smokers (submitted to smoke exposure at a rate of 40 cigarettes/day) and nonsmokers. At the end of the experimental periods, the aortas were removed and crosssectioned to obtain histologic specimens for light microscopic and morphometric analyses. The remaining longitudinal segments were stretched to rupture and mechanical parameters were determined. Results: A degenerative process (i.e., a reduction in elastic fibers, the loss of lamellar arrangement, and a reduction of smooth muscle cells) was observed, and this effect was proportional in intensity to the period of tobacco exposure. We observed a progressive reduction in the yield point of the thoracic aorta over time (P < 0.05). There was a decrease in stiffness (P < 0.05) and in failure load (P < 0.05) at 6 months in the abdominal aorta of rats in the smoking group. Conclusions: Chronic exposure to tobacco smoke can affect the mechanical properties of the aorta and can also provoke substantial structural changes of the arterial wall
Resumo:
The optical quality of the human eye mainly depends on the refractive performance of the cornea. The shape of the cornea is a mechanical balance between intraocular pressure and tissue intrinsic stiffness. Several surgical procedures in ophthalmology alter the biomechanics of the cornea to provoke local or global curvature changes for vision correction. Legitimated by the large number of surgical interventions performed every day, the demand for a deeper understanding of corneal biomechanics is rising to improve the safety of procedures and medical devices. The aim of our work is to propose a numerical model of corneal biomechanics, based on the stromal microstructure. Our novel anisotropic constitutive material law features a probabilistic weighting approach to model collagen fiber distribution as observed on human cornea by Xray scattering analysis (Aghamohammadzadeh et. al., Structure, February 2004). Furthermore, collagen cross-linking was explicitly included in the strain energy function. Results showed that the proposed model is able to successfully reproduce both inflation and extensiometry experimental data (Elsheikh et. al., Curr Eye Res, 2007; Elsheikh et. al., Exp Eye Res, May 2008). In addition, the mechanical properties calculated for patients of different age groups (Group A: 65-79 years; Group B: 80-95 years) demonstrate an increased collagen cross-linking, and a decrease in collagen fiber elasticity from younger to older specimen. These findings correspond to what is known about maturing fibrous biological tissue. Since the presented model can handle different loading situations and includes the anisotropic distribution of collagen fibers, it has the potential to simulate clinical procedures involving nonsymmetrical tissue interventions. In the future, such mechanical model can be used to improve surgical planning and the design of next generation ophthalmic devices.
Resumo:
OBJECTIVE To biomechanically test the properties of three different Universal Micro External Fixator (UMEX™) configurations with regard to their use in very small animals (<5kg) and compare the UMEX system to the widely used IMEX External Skeletal Fixation (SK™) system in terms of stiffness, space needed for pin placement and weight. METHODS Three different UMEX configurations (type Ia, type Ib, and type II modified) and one SK configuration type Ia were used to stabilize Delrin plastic rods in a 1 cm fracture gap model. These constructs were tested in axial compression, craniocaudal bending, mediolateral bending, and torsion. Testing was conducted within the elastic range and mean stiffness in each mode was determined from the slope of the linear portion of the load-deformation curve. A Kruskal Wallis one-way analysis of variance on ranks test was utilized to assess differences between constructs (p <0.05). RESULTS The UMEX type II modified configuration was significantly stiffer than the other UMEX configurations and the SK type Ia, except in craniocaudal bending, where the SK type Ia configuration was stiffer than all UMEX constructs. The UMEX type Ia configuration was significantly the weakest of those frames. The UMEX constructs were lighter and smaller than the SK, thus facilitating closer pin placement. CONCLUSIONS Results supported previous reports concerning the superiority of more complex constructs regarding stiffness. The UMEX system appears to be a valid alternative for the treatment of long-bone fractures in very small animals.
Resumo:
Neuronal growth is a complex process involving many intra- and extracellular mechanisms which are collaborating conjointly to participate to the development of the nervous system. More particularly, the early neocortical development involves the creation of a multilayered structure constituted by neuronal growth (driven by axonal or dendritic guidance cues) as well as cell migration. The underlying mechanisms of such structural lamination not only implies important biochemical changes at the intracellular level through axonal microtubule (de)polymerization and growth cone advance, but also through the directly dependent stress/stretch coupling mechanisms driving them. Efforts have recently focused on modeling approaches aimed at accounting for the effect of mechanical tension or compression on the axonal growth and subsequent soma migration. However, the reciprocal influence of the biochemical structural evolution on the mechanical properties has been mostly disregarded. We thus propose a new model aimed at providing the spatially dependent mechanical properties of the axon during its growth. Our in-house finite difference solver Neurite is used to describe the guanosine triphosphate (GTP) transport through the axon, its dephosphorylation in guanosine diphosphate (GDP), and thus the microtubules polymerization. The model is calibrated against experimental results and the tensile and bending mechanical stiffnesses are ultimately inferred from the spatially dependent microtubule occupancy. Such additional information is believed to be of drastic relevance in the growth cone vicinity, where biomechanical mechanisms are driving axonal growth and pathfinding. More specifically, the confirmation of a lower stiffness in the distal axon ultimately participates in explaining the controversy associated to the tensile role of the growth cone.