954 resultados para Computer software - Quality control
Resumo:
Bovine spongiform encephalopathy (BSE) rapid tests and routine BSE-testing laboratories underlie strict regulations for approval. Due to the lack of BSE-positive control samples, however, full assay validation at the level of individual test runs and continuous monitoring of test performance on-site is difficult. Most rapid tests use synthetic prion protein peptides, but it is not known to which extend they reflect the assay performance on field samples, and whether they are sufficient to indicate on-site assay quality problems. To address this question we compared the test scores of the provided kit peptide controls to those of standardized weak BSE-positive tissue samples in individual test runs as well as continuously over time by quality control charts in two widely used BSE rapid tests. Our results reveal only a weak correlation between the weak positive tissue control and the peptide control scores. We identified kit-lot related shifts in the assay performances that were not reflected by the peptide control scores. Vice versa, not all shifts indicated by the peptide control scores indeed reflected a shift in the assay performance. In conclusion these data highlight that the use of the kit peptide controls for continuous quality control purposes may result in unjustified rejection or acceptance of test runs. However, standardized weak positive tissue controls in combination with Shewhart-CUSUM control charts appear to be reliable in continuously monitoring assay performance on-site to identify undesired deviations.
Resumo:
BACKGROUND Retinal optical coherence tomography (OCT) permits quantification of retinal layer atrophy relevant to assessment of neurodegeneration in multiple sclerosis (MS). Measurement artefacts may limit the use of OCT to MS research. OBJECTIVE An expert task force convened with the aim to provide guidance on the use of validated quality control (QC) criteria for the use of OCT in MS research and clinical trials. METHODS A prospective multi-centre (n = 13) study. Peripapillary ring scan QC rating of an OCT training set (n = 50) was followed by a test set (n = 50). Inter-rater agreement was calculated using kappa statistics. Results were discussed at a round table after the assessment had taken place. RESULTS The inter-rater QC agreement was substantial (kappa = 0.7). Disagreement was found highest for judging signal strength (kappa = 0.40). Future steps to resolve these issues were discussed. CONCLUSION Substantial agreement for QC assessment was achieved with aid of the OSCAR-IB criteria. The task force has developed a website for free online training and QC certification. The criteria may prove useful for future research and trials in MS using OCT as a secondary outcome measure in a multi-centre setting.
Resumo:
Introduction Since the quality of patient portrayal of standardized patients (SPs) during an Objective Structured Clinical Exam (OSCE) has a major impact on the reliability and validity of the exam, quality control should be initiated. Literature about quality control of SP’s performance focuses on feedback [1, 2] or completion of checklists [3, 4]. Since we did not find a published instrument meeting our needs for the assessment of patient portrayal, we developed such an instrument after being inspired by others [5] and used it in our high-stakes exam. Methods SP trainers from all five Swiss medical faculties collected and prioritized quality criteria for patient portrayal. Items were revised with the partners twice, based on experiences during OSCEs. The final instrument contains 14 criteria for acting (i.e. adequate verbal and non-verbal expression) and standardization (i.e. verbatim delivery of the first sentence). All partners used the instrument during a high-stakes OSCE. Both, SPs and trainers were introduced to the instrument. The tool was used in training (more than 100 observations) and during the exam (more than 250 observations). FAIR_OSCE The list of items to assess the quality of the simulation by SPs was primarily developed and used to provide formative feedback to the SPs in order to help them to improve their performance. It was therefore named “Feedbackstruckture for the Assessment of Interactive Role play in Objective Structured Clinical Exams (FAIR_OSCE). It was also used to assess the quality of patient portrayal during the exam. The results were calculated for each of the five faculties individually. Formative evaluation was given to the five faculties with individual feedback without revealing results of other faculties other than overall results. Results High quality of patient portrayal during the exam was documented. More than 90% of SP performances were rated to be completely correct or sufficient. An increase in quality of performance between training and exam was noted. In example the rate of completely correct reaction in medical tests increased from 88% to 95%. 95% completely correct reactions together with 4% sufficient reactions add up to 99% of the reactions meeting the requirements of the exam. SP educators using the instrument reported an augmentation of SPs performance induced by the use of the instrument. Disadvantages mentioned were high concentration needed to explicitly observe all criteria and cumbersome handling of the paper-based forms. Conclusion We were able to document a very high quality of SP performance in our exam. The data also indicate that our training is effective. We believe that the high concentration needed using the instrument is well invested, considering the observed augmentation of performance. The development of an iPad based application for the form is planned to address the cumbersome handling of the paper.
Resumo:
Sample preparation procedures for AMS measurements of 129I and 127I in environmental materials and some methodological aspects of quality assurance are discussed. Measurements from analyses of some pre-nuclear soil and thyroid gland samples and of a systematic investigation of natural waters in Lower Saxony, Germany, are described. Although the up-to-now lowest 129I/127I ratios in soils and thyroid glands were observed, they are still suspect to contamination since they are significantly higher than the pre-nuclear equilibrium ratio in the marine hydrosphere. A survey on all available 129I/127I isotopic ratios in precipitation shows a dramatic increase until the middle of the 1980s and a stabilization since 1987 at high isotopic ratios of about (3.6–8.3)×10−7. In surface waters, ratios of (57–380)×10−10 are measured while shallow ground waters show with ratios of (1.3–200)×10−10 significantly lower values with a much larger spread. The data for 129I in soils and in precipitation are used to estimate pre-nuclear and modern 129I deposition densities.
Resumo:
MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1) H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.
Resumo:
In this paper, we use ARIMA modelling to estimate a set of characteristics of a short-term indicator (for example, the index of industrial production), as trends, seasonal variations, cyclical oscillations, unpredictability, deterministic effects (as a strike), etc. Thus for each sector and product (more than 1000), we construct a vector of values corresponding to the above-mentioned characteristics, that can be used for data editing.
Resumo:
La emisión de polvo por efecto del viento desde depósitos de residuos mineros o industriales y el paso de vehículos en vías no pavimentadas, es un problema que afecta las actividades productivas; el ambiente y la salud de las personas que permanecen en el área contaminada. En Chile, en los últimos años la sensibilidad social y las exigencias ambientales han aumentado, así como la oferta de diferentes supresores y tecnologías de aplicación. Se han revisado las causas que provocan emisión de polvo y las tecnologías disponibles en Chile para la supresión de polvo, además de las metodologías y normativa para evaluar el desempeño de los materiales tratados con diferentes supresores. En algunos casos no es posible comparar propiedades de desempeño, como durabilidad, dosis a aplicar y frecuencia de las aplicaciones, entre otros aspectos. Los procedimientos descritos en la norma NCh3266-2012 permiten evaluar la erosión eólica en depósitos de residuos, sitios eriazos y caminos no pavimentados, entre otros, junto con evaluar el desempeño de diferentes tipos de supresores de polvo a partir de datos objetivos comparables. Esto permite seleccionar el supresor más adecuado, mejorar la eficiencia de los tratamientos, optimizar los costos y mejorar los procesos productivos. Palabras clave: Erosión-eólica, supresor de polvo, residuos-mineros, caminos-no pavimentados. Dust emissions by wind effect from mining deposits or industrial waste and passing vehicles on unpaved roads, is a problem that affects the productive activities; the environment and the health of those who remain in the contaminated area. The social sensitivity and environmental requirements on this issue in Chile have increased, as well as offering different suppressors and application technologies. Have been reviewed the causes of dust emission and technologies available in Chile for dust suppression, plus methodologies and standards for assessing the performance of the treated materials with different suppressors. In some cases it is not possible to compare performance properties such as durability, application dose and frequency of applications, among others aspects. The procedures described in the NCh 3266-2012 standard allows the assessment of wind erosion in waste deposits, vacant lots and unpaved roads, among others, along with evaluating the performance of different types of dust suppressants from comparable objective data. This allows selecting the most suitable suppressor, improve efficiency of treatments, optimize costs and improve production processes. Keywords: Wind-erosion, dust-suppressor, mining-waste, unpavedroads
Resumo:
Research into software engineering teams focuses on human and social team factors. Social psychology deals with the study of team formation and has found that personality factors and group processes such as team climate are related to team effectiveness. However, there are only a handful of empirical studies dealing with personality and team climate and their relationship to software development team effectiveness. Objective We present aggregate results of a twice replicated quasi-experiment that evaluates the relationships between personality, team climate, product quality and satisfaction in software development teams. Method Our experimental study measures the personalities of team members based on the Big Five personality traits (openness, conscientiousness, extraversion, agreeableness, neuroticism) and team climate factors (participative safety, support for innovation, team vision and task orientation) preferences and perceptions. We aggregate the results of the three studies through a meta-analysis of correlations. The study was conducted with students. Results The aggregation of results from the baseline experiment and two replications corroborates the following findings. There is a positive relationship between all four climate factors and satisfaction in software development teams. Teams whose members score highest for the agreeableness personality factor have the highest satisfaction levels. The results unveil a significant positive correlation between the extraversion personality factor and software product quality. High participative safety and task orientation climate perceptions are significantly related to quality. Conclusions First, more efficient software development teams can be formed heeding personality factors like agreeableness and extraversion. Second, the team climate generated in software development teams should be monitored for team member satisfaction. Finally, aspects like people feeling safe giving their opinions or encouraging team members to work hard at their job can have an impact on software quality. Software project managers can take advantage of these factors to promote developer satisfaction and improve the resulting product.
Resumo:
En este Trabajo Fin de Grado se aborda la concepción, diseño, desarrollo y testeo de un robot esférico. En el se cubre el diseño mecánico y su fabricación, el modelado dinámico y su control, y el diseño hardware y software.
Resumo:
El proyecto trata del desarrollo de un software para realizar el control de la medida de la distribución de intensidad luminosa en luminarias LED. En el trascurso del proyecto se expondrán fundamentos teóricos sobre fotometría básica, de los cuales se extraen las condiciones básicas para realizar dicha medida. Además se realiza una breve descripción del hardware utilizado en el desarrollo de la máquina, el cual se basa en una placa de desarrollo Arduino Mega 2560, que, gracias al paquete de Labview “LIFA” (Labview Interface For Arduino”), será posible utilizarla como tarjeta de adquisición de datos mediante la cual poder manejar tanto sensores como actuadores, para las tareas de control. El instrumento de medida utilizado en este proyecto es el BTS256 de la casa GigaHerzt-Optik, del cual se dispone de un kit de desarrollo tanto en lenguaje C++ como en Labview, haciendo posible programar aplicaciones basadas en este software para realizar cualquier tipo de adaptación a las necesidades del proyecto. El software está desarrollado en la plataforma Labview 2013, esto es gracias a que se dispone del kit de desarrollo del instrumento de medida, y del paquete LIFA. El objetivo global del proyecto es realizar la caracterización de luminarias LED, de forma que se obtengan medidas suficientes de la distribución de intensidad luminosa. Los datos se recogerán en un archivo fotométrico específico, siguiendo la normativa IESNA 2002 sobre formato de archivos fotométricos, que posteriormente será utilizado en la simulación y estudio de instalaciones reales de la luminaria. El sistema propuesto en este proyecto, es un sistema basado en fotometría tipo B, utilizando coordenadas VH, desarrollando un algoritmo de medida que la luminaria describa un ángulo de 180º en ambos ejes, con una resolución de 5º para el eje Vertical y 22.5º para el eje Horizontal, almacenando los datos en un array que será escrito en el formato exigido por la normativa. Una vez obtenidos los datos con el instrumento desarrollado, el fichero generado por la medida, es simulado con el software DIALux, obteniendo unas medidas de iluminación en la simulación que serán comparadas con las medidas reales, intentando reproducir en la simulación las condiciones reales de medida. ABSTRACT. The project involves the development of software for controlling the measurement of light intensity distribution in LEDs. In the course of the project theoretical foundations on basic photometry, of which the basic conditions for such action are extracted will be presented. Besides a brief description of the hardware used in the development of the machine, which is based on a Mega Arduino plate 2560 is made, that through the package Labview "LIFA" (Interface For Arduino Labview "), it is possible to use as data acquisition card by which to handle both sensors and actuators for control tasks. The instrument used in this project is the BTS256 of GigaHerzt-Optik house, which is available a development kit in both C ++ language as LabView, making it possible to program based on this software applications for any kind of adaptation to project needs. The software is developed in Labview 2013 platform, this is thanks to the availability of the SDK of the measuring instrument and the LIFA package. The overall objective of the project is the characterization of LED lights, so that sufficient measures the light intensity distribution are obtained. Data will be collected on a specific photometric file, following the rules IESNA 2002 on photometric format files, which will then be used in the simulation and study of actual installations of the luminaire. The proposed in this project is a system based on photometry type B system using VH coordinates, developing an algorithm as the fixture describe an angle of 180 ° in both axes, with a resolution of 5 ° to the vertical axis and 22.5º for the Horizontal axis, storing data in an array to be written in the format required by the regulations. After obtaining the data with the instrument developed, the file generated by the measure, is simulated with DIALux software, obtaining measures of lighting in the simulation will be compared with the actual measurements, trying to play in the simulation the actual measurement conditions .
Resumo:
The human asialoglycoprotein receptor H2a subunit contains a charged pentapeptide, EGHRG, in its ectodomain that is the only sequence absent from the H2b alternatively spliced variant. H2b exits the endoplasmic reticulum (ER) even when singly expressed, whereas H2a gives rise to a cleaved soluble secreted ectodomain fragment; uncleaved membrane-bound H2a molecules are completely retained and degraded in the ER. We have inserted the H2a pentapeptide into the sequence of the H1 subunit (H1i5), which caused complete ER retention but, unexpectedly, no degradation. This suggests that the pentapeptide is a determinant for ER retention not colocalizing in H2a with the determinant for degradation. The state of sugar chain processing and the ER localization of H1i5, which was unchanged at 15°C or after treatment with nocodazole, indicate ER retention and not retrieval from the cis-Golgi or the intermediate compartment. H1i5 folded similarly to H1, and both associated to calnexin. However, whereas H1 dissociated with a half time of 45 min, H1i5 remained bound to the chaperone for prolonged periods. The correct global folding of H2a and H1i5 and of other normal precursors and unassembled proteins and the true ER retention, and not exit and retrieval, suggest a difference in their quality control mechanism compared with that of misfolded proteins, which does involve retrieval. However, both pathways may involve calnexin.
Resumo:
We are studying the intracellular trafficking of the multispanning membrane protein Ste6p, the a-factor transporter in Saccharomyces cerevisiae and a member of the ATP-binding cassette superfamily of proteins. In the present study, we have used Ste6p as model for studying the process of endoplasmic reticulum (ER) quality control, about which relatively little is known in yeast. We have identified three mutant forms of Ste6p that are aberrantly ER retained, as determined by immunofluorescence and subcellular fractionation. By pulse-chase metabolic labeling, we demonstrate that these mutants define two distinct classes. The single member of Class I, Ste6–166p, is highly unstable. We show that its degradation involves the ubiquitin–proteasome system, as indicated by its in vivo stabilization in certain ubiquitin–proteasome mutants or when cells are treated with the proteasome inhibitor drug MG132. The two Class II mutant proteins, Ste6–13p and Ste6–90p, are hyperstable relative to wild-type Ste6p and accumulate in the ER membrane. This represents the first report of a single protein in yeast for which distinct mutant forms can be channeled to different outcomes by the ER quality control system. We propose that these two classes of ER-retained Ste6p mutants may define distinct checkpoint steps in a linear pathway of ER quality control in yeast. In addition, a screen for high-copy suppressors of the mating defect of one of the ER-retained ste6 mutants has identified a proteasome subunit, Hrd2p/p97, previously implicated in the regulated degradation of wild-type hydroxymethylglutaryl-CoA reductase in the ER membrane.
Resumo:
Unlike properly folded and assembled proteins, most misfolded and incompletely assembled proteins are retained in the endoplasmic reticulum of mammalian cells and degraded without transport to the Golgi complex. To analyze the mechanisms underlying this unique sorting process and its fidelity, the fate of C-terminally truncated fragments of influenza hemagglutinin was determined. An assortment of different fragments was generated by adding puromycin at low concentrations to influenza virus-infected tissue culture cells. Of the fragments generated, <2% was secreted, indicating that the system for detecting defects in newly synthesized proteins is quite stringent. The majority of secreted species corresponded to folding domains within the viral spike glycoprotein. The retained fragments acquired a partially folded structure with intrachain disulfide bonds and conformation-dependent antigenic epitopes. They associated with two lectin-like endoplasmic reticulum chaperones (calnexin and calreticulin) but not BiP/GRP78. Inhibition of the association with calnexin and calreticulin by the addition of castanospermine significantly increased fragment secretion. However, it also caused association with BiP/GRP78. These results indicated that the association with calnexin and calreticulin was involved in retaining the fragments. They also suggested that BiP/GRP78 could serve as a backup for calnexin and calreticulin in retaining the fragments. In summary, the results showed that the quality control system in the secretory pathway was efficient and sensitive to folding defects, and that it involved multiple interactions with endoplasmic reticulum chaperones.