958 resultados para Composer-conductor
Resumo:
Conventional whole-body single frequency bioelectrical impedance analysis (BIA) of body composition typically uses height as a surrogate measure of conductor length. A new method of BIA analysis for the prediction of body cell mass (BCM) and extracellular water (ECW, as % body weight) not using height has been introduced-the Soft Tissue Analyser (STA(TM), Akern Sri, Florence, Italy)-making it ideal for use in subjects where measurement of height is difficult or impossible. The performance of the new analytical method in predicting BCM and ECW in 139 normal control subjects was assessed by comparison with reference data obtained from a four-component (4-C) model of body composition and with predictions obtained from conventional BIA analysis. Both predicted BCM and ECW were strongly (r = 0.82, SEE = 6.3 kg and 0.89, SEE = 1.3 kg respectively) correlated with the corresponding 4-C model measurements although differing significantly from the lines of identity (P < 0.0001). Fat-free mass, calculated from STA estimates of BCM and ECW, was better predicted (r = 0.91, SEE = 5.6 kg). The significant differences in STA-group mean values for BCM and ECW and wide limits of agreement compared with the reference data indicate that the method cannot be used with confidence for prediction of these body compartments despite the obvious advantage of not requiring an accurate measurement of height. (C) 2001 Harcourt Publishers Ltd.
Resumo:
Synthetic aperture radar (SAR) images of resonant buried objects are modelled in the presence of ground surface clutter. The method of moments (MoM) is used to model scattered fields from a resonant buried conductor and clutter is modelled as a bivariant Gaussian distribution. A diffraction stack SAR imaging technique is applied to the ultra-wideband waveforms to give a bipolar signal image. A number of examples have been computed to illustrate the combined effects of SAR processing with resonant targets and clutter. SAR images of different targets show differences which may facilitate target identification. To maximise the peak signal-to-clutter ratio, an image correlation technique is applied and the results are shown.
Resumo:
Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.
Resumo:
Prior theoretical studies indicate that the negative spatial derivative of the electric field induced by magnetic stimulation may he one of the main factors contributing to depolarization of the nerve fiber. This paper studies this parameter for peripheral nerve stimulation (PNS) induced by time.-varying gradient fields during MRI scans. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic human, full-body model. Whole-body cylindrical and planar gradient sets in MRI systems and various input signals have been explored. The spatial distributions of the induced electric field and their gradients are calculated and attempts are made to correlate these areas with reported experimental stimulation data. The induced electrical field pattern is similar for both the planar coils and cylindrical coils. This study provides some insight into the spatial characteristics of the induced field gradients for PNS in MRI, which may be used to further evaluate the sites where magnetic stimulation is likely to occur and to optimize gradient coil design.
Resumo:
In modern magnetic resonance imaging (MRI), patients are exposed to strong, nonuniform static magnetic fields outside the central imaging region, in which the movement of the body may be able to induce electric currents in tissues which could be possibly harmful. This paper presents theoretical investigations into the spatial distribution of induced electric fields and currents in the patient when moving into the MRI scanner and also for head motion at various positions in the magnet. The numerical calculations are based on an efficient, quasi-static, finite-difference scheme and an anatomically realistic, full-body, male model. 3D field profiles from an actively shielded 4T magnet system are used and the body model projected through the field profile with a range of velocities. The simulation shows that it possible to induce electric fields/currents near the level of physiological significance under some circumstances and provides insight into the spatial characteristics of the induced fields. The results are extrapolated to very high field strengths and tabulated data shows the expected induced currents and fields with both movement velocity and field strength. (C) 2003 Elsevier Science (USA). All rights reserved.
Resumo:
O trabalho pretende desenvolver uma reflex??o sobre a profissionaliza????o dos cargos de dire????o na administra????o p??blica e sua evolu????o ao longo das ??ltimas d??cadas nos pa??ses desenvolvidos, tendo como eixo condutor a institucionaliza????o dos cargos de dirigentes p??blicos nos sistemas pol??tico-administrativos contempor??neos. Inicia-se definindo a expans??o e o desenvolvimento do gerenciamento nos sistemas p??blicos, descrevendo, de forma breve e comparada, sua evolu????o mais recente em alguns pa??ses da OCDE. Em seguida, s??o apontados os tra??os b??sicos de um modelo de exerc??cio das fun????es de dire????o na administra????o p??blica. A seguir, trata-se do tema central mencionado. Primeiramente, o texto define os elementos que configuram um marco institucional para as fun????es de dire????o no setor p??blico. Depois, aborda o conte??do, o alcance e o ??mbito das reformas necess??rias para a constru????o desse marco. Por ??ltimo, analisa as vari??veis que podem influenciar a elabora????o das reformas, expondo os principais desafios e dificuldades tra??ados pelos empenhos de reforma.
Resumo:
This paper describes the design of a textile microstrip antenna for 2.4 GHz. Two different fabrics are used: one for the dielectric part and another one for the conductor part. The dielectric constant of the dielectric fabric is determined experimentally. The input matching is studied by electromagnetic simulation and experimentally. Since the antenna is meant to be incorporated in the user's clothe, the effect that the antenna bending has on the matching level is also investigated both theoretically and experimentally.
Resumo:
In this paper, the design of low profile antennas by using Electromagnetic Band Gap (EBG) structures is introduced. Taking advantage of the fact that they can behave as Perfect Magnetic Conductor (PMC), it is shown that these structures exhibit dual band in-phase reflection at WLAN (Wireless Local Area Network) bands, the 2.4 GHz and 5.2 GHz bands. These structures are applied to PIFA (Planar Inverted-F Antenna) and the results show that it is possible to obtain low profile PIFA's.
Resumo:
Mestrado (PES II), Educação Pré-Escolar e Ensino do 1º Ciclo do Ensino Básico, 1 de Julho de 2014, Universidade dos Açores.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia de Electrónica e Telecomunicações
Resumo:
In an age where Babel has turned into transcultural communication, an interlingual approach – i.e. in English and in French – to the translating process from German to Portuguese appeared pertinent. Aiming at a refinement of the translating competence, this process consists in contrasting different linguistic and literary strategies through an intercultural and multi-etymological perspective. Thus, we settled upon Heiner Müller‘s play Der Auftrag. Erinnerung an eine Revolution (1980), on which the composer Heiner Goebbels has based himself to textually and musically dramatize an excerpt, Der Mann im Farhstuhl / The Man in the Elevator. A transcription of such excerpt in its source language, German, as well as its translation into English (Carl Weber, 1984, Performing Arts Publications, New York) and French (Jean Jourdheuil, Heinz Schwarzinger, Editions Minuit, Paris) can be found in the booklet that accompanies the CD – edited in 1988 by ECD (München: Records GmbH). It should be emphasized that such a creation allows a framing of Müller‘s text into a musical scenography and, therefore, encourages an intersemiotic contrast. This experience enabled us to come up with a unique imagery of Müller‘s piece of writing, by means of its dramatic and musical conversion and, simultaneously, lead us to stretch our textual consciousness to a multitude of intra-, extra- and interlinguistic elements.
Resumo:
Conferência: 9th International Symposium on Occupational Safety and Hygiene (SHO) Guimaraes, Portugal - FEB 14-15, 2013
Resumo:
A maioria dos órgãos históricos portugueses data dos finais do século XVIII ou do princípio do século XIX. Durante este período foi construído um invulgar número de instrumentos em Lisboa e nas áreas circundantes por António Xavier Machado e Cerveira (1756-1828) e outros organeiros menos prolíficos. O estudo desses órgãos, muitos dos quais (restaurados ou não) se encontram próximos das condições originais, permite a identificação de um tipo de instrumento com uma morfologia específica, claramente emancipada do chamado «órgão ibérico». No entanto, até muito recentemente, não era conhecida música que se adaptasse às idiossincrasisas daqueles instrumentos. O recente estudo das obras para órgão de José Marques e Silva (1782-1837) permitiu clarificar esta situação. Bem conhecido durante a sua vida como organista e compositor, José Marques e Silva foi um dos ultimos mestres do Seminário Patriarcal. A importância da sua produção musical reside não só num substancial número de obras com autoria firmemente estabelecida – escritas, na maior parte, para coro misto com acompanhamento de órgão obbligato – mas também na íntima relação entre a sua escrita e a morfologia dos órgãos construídos em Portugal durante a sua vida. Este artigo enfatiza a importância de José Marques e Silva (indubitavelmente, o mais significativo compositor português para órgão do seu tempo) sublinhando a relevância das suas obras para órgão solo, cujo uso extensivo de escrita idiomática e indicações de registação fazem delas um dos mais importantes documentos só início do século XIX sobre a prática organística em Portugal.
Resumo:
For musicians, the impact of noise exposure is not yet fully characterized. Some inconsistencies can be found in the methodology used to evaluate noise exposure. This study aims to analyze the noise exposure of musicians in a symphonic orchestra to understand their risk for hearing loss, applying the methodology proposed by ISO 9612:2009. Noise levels were monitored among musicians during the rehearsal of eight different repertoires. Test subjects were selected according to their instrument and position in the orchestra. Participants wore noise dosimeters throughout the rehearsals. A sound meter was used to analyze the exposure of the conductor. The results showed that musicians are exposed to high noise levels that can damage hearing. Brass, woodwind and percussion and timpani musicians were exposed to noise levels in excess of the upper exposure action level of 85 dB (A), while the other instrumental groups had a lower exposure action level of 80 dB (A). Percussion musicians were exposed to high peak noise levels of 135 dB (C). Sound levels varied by instrument, repertoire and position. Octave frequency analyses showed differences among musicians. This study suggests that musicians are at risk for hearing loss. There is a need for more effective guidelines applicable to all countries, which should define standardized procedures for determining musician noise exposure and should allow exposure level normalization to the year, including different repertoires.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia dos Materiais