992 resultados para Chromatographic method
Resumo:
Dissertação composta por 02 artigos.
Resumo:
The southern region of Brazil, especially the states of Parana and Santa Catarina stand out for growing grapes and apples for fresh consumption and in order to add value to these products, process the material for the production of wine, juices and jellies . As a result large quantities of by-products, such as peels, seeds and pulp are produced becoming environmental problems. Studies reuse of these by-products have attracted interest because they have shown a high biological potential, due to the presence of high levels of phenolic compounds, which are associated with a lower incidence of disease caused by oxidative stress, due to its antioxidant, antiinflammatory and antibacterial properties. Currently, few studies are presented on the phenolic composition and biological potential of waste grape variety Bordô (Vitis labrusca) and apple (Malus domestica) Gala variety, cultivated in southern Brazil. Within this context, the objectives of this study were: compare the efficiency of solidliquid and liquid-liquid extraction, perform the optimization and validation of analytical methodology by HPLC-DAD for the separation, identification and quantification of multiclass phenolic compounds, evaluate the activity antioxidant by sequestering methods of free radical 2,2-diphenyl-1 picrilhidrazina (DPPH) and 2,2-azino-bis (3- ethyl-benzthiazoline-6-sulphonic acid) (ABTS) solution, reduction of Fe3+ in Fe2+ method (FRAP), ORAC, RP-HPLC-ABTS online, Rancimat and determination of total phenolics three agro-industrial byproducts, pomace and stems grape Bordô produced in Paraná Southwest region and Gala apple pomace coming from the Santa Catarina West. Optimization and validation of chromatographic method showed satisfactory quality parameters for the compounds of interest and the solidliquid extraction was more efficient in extracting phenolic evaluated. The three byproducts evaluated showed significant levels of phenolic compounds when analyzed by HPLC, especially flavonoids, catechin and epicatechin besides that showed significant antioxidant capacity. The grape stems extract had the highest sequestration capacity of DPPH and ABTS radical and reduced iron, and high content of phenolic compounds. The apple pomace extract showed the best response to the Rancimat method, which indicates a high potential to protect the oil from lipid oxidation, was no significant difference when compared to synthetic antioxidant TBHQ. The results of this study showed that the agro-industrial coproducts analyzed are rich in phenolic compounds of high antioxidant capacity and therefore must be better explored by the food and pharmaceutical industries.
Resumo:
International audience
Resumo:
As leveduras Dekkera/Brettanomyces são responsáveis pela formação de fenóis voláteis em vinhos tintos, tornando-se numa grande preocupação para a produção enológica a nível mundial, devido à dificuldade em controlá-las. Os fenóis voláteis são responsáveis por aromas desagradáveis nos vinhos tintos, diminuindo a sua qualidade e resultando em grandes perdas económicas. Este trabalho teve como principal objectivo estudar um método de preparação de amostra e um método cromatográfico para analisar e quantificar os principais fenóis voláteis (4-etilfenol, 4-etilguaiacol, 4-etilcatecol, 4-vinilfenol e o 4-vinilguaiacol), em meio sintético e em vinhos tintos comerciais. A preparação de amostras foi efectuada através do método de extracção líquido-líquido e a separação dos compostos foi efectuada por cromatografia gasosa com detector de ionização de chama (GC-FID). Os resultados obtidos permitem concluir que é possível detectar e quantificar os fenóis voláteis com este método, incluindo o 4-etilcatecol. O 4-etilfenol foi o composto mais abundante nos vinhos tintos comerciais estudados. ABSTRACT: The yeasts Dekkera I Brettanomyces are responsible for the formation of volatile phenols in red wine, becoming a major concern for the enological production worldwide because of the difficulty in controlling them. The volatile phenols are responsible for unpleasant aromas in red wines, reducing its quality and resulting in great economic lasses. The main objective of this work was to study a sample preparation and a chromatographic method to analyze main volatile phenols (4-ethylphenol, 4-ethylguaiacol, 4-ethylcatechol, 4-vinylphenol and 4-vinylguaiacol) in synthetic wine and red wines. Sample preparation was done by liquid-liquid extraction and compounds separation was achieved by gas chromatography with flame ionization detector (GC FID) Results showed that it is possible to detect and quantified volatile phenols with the methodology proposed, including 4-ethylcatechol. 4-ethylphenol was the main compound found in commercial red wines.
Resumo:
Thanks to the development and combination of molecular markers for the genetic traceability of sunflower varieties and a gas chromatographic method for the determination of the FAs composition of sunflower oil, it was possible to implement an experimental method for the verification of both the traceability and the variety of organic sunflower marketed by Agricola Grains S.p.A. The experimental activity focused on two objectives: the implementation of molecular markers for the routine control of raw material deliveries for oil extraction and the improvement and validation of a gas chromatographic method for the determination of the FAs composition of sunflower oil. With regard to variety verification and traceability, the marker systems evaluated were the following: SSR markers (12) arranged in two multiplex sets and SCAR markers for the verification of cytoplasmic male sterility (Pet1) and fertility. In addition, two objectives were pursued in order to enable a routine application in the industrial field: the development of a suitable protocol for DNA extraction from single seeds and the implementation of a semi-automatic capillary electrophoresis system for the analysis of marker fragments. The development and validation of a new GC/FID analytical method for the determination of fatty acids (FAME) in sunflower achenes to improve the quality and efficiency of the analytical flow in the control of raw and refined materials entering the Agricola Grains S.p.A. production chain. The analytical performances being validated by the newly implemented method are: linearity of response, limit of quantification, specificity, precision, intra-laboratory precision, robustness, BIAS. These parameters are used to compare the newly developed method with the one considered as reference - Commission Regulation No. 2568/91 and Commission Implementing Regulation No. 2015/1833. Using the combination of the analytical methods mentioned above, the documentary traceability of the product can be confirmed experimentally, providing relevant information for subsequent marketing.
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
A method is described for the analysis of deuterated and undeuterated alpha-tocopherol in blood components using liquid chromatography coupled to an orthogonal acceleration time-of-flight (TOF) mass spectrometer. Optimal ionisation conditions for undeuterated (d0) and tri- and hexadeuterated (d3 or d6) alpha-tocopherol standards were found with negative ion mode electrospray ionisation. Each species produced an isotopically resolved single ion of exact mass. Calibration curves of pure standards were linear in the range tested (0-1.5 muM, 0-15 pmol injected). For quantification of d0 and d6 in blood components following a standard solvent extraction, a stable-isotope-labelled internal standard (d3-alpha-tocopherol) was employed. To counter matrix ion suppression effects, standard response curves were generated following identical solvent extraction procedures to those of the samples. Within-day and between-day precision were determined for quantification of d0- and d6-labelled alpha-tocopherol in each blood component and both averaged 3-10%. Accuracy was assessed by comparison with a standard high-performance liquid chromatography (HPLC) method, achieving good correlation (r(2) = 0.94), and by spiking with known concentrations of alpha-tocopherol (98% accuracy). Limits of detection and quantification were determined to be 5 and 50 fmol injected, respectively. The assay was used to measure the appearance and disappearance of deuterium-labelled alpha-tocopherol in human blood components following deuterium-labelled (d6) RRR-alpha-tocopheryl acetate ingestion. The new LC/TOFMS method was found to be sensitive, required small sample volumes, was reproducible and robust, and was capable of high throughput when large numbers of samples were generated. Copyright (C) 2003 John Wiley Sons, Ltd.
Resumo:
Mycolic acids analysis by thin-layer chromatography (TLC) has been employed by several laboratories worldwide as a method for fast identification of mycobacteria. This method was introduced in Brazil by our laboratory in 1992 as a routine identification technique. Up to the present, 861 strains isolated were identified by mycolic acids TLC and by standard biochemical tests; 61% out of these strains came as clinical samples, 4% isolated from frogs and 35% as environmental samples. Mycobacterium tuberculosis strains identified by classical methods were confirmed by their mycolic acids contents (I, III and IV). The method allowed earlier differentiation of M. avium complex - MAC (mycolic acids I, IV and VI) from M. simiae (acids I, II and IV), both with similar biochemical properties. The method also permitted to distinguish M. fortuitum (acids I and V) from M. chelonae (acids I and II) , and to detect mixed mycobacterial infections cases as M. tuberculosis with MAC and M. fortuitum with MAC. Concluding, four years experience shows that mycolic acids TLC is an easy, reliable, fast and inexpensive method, an important tool to put together conventional mycobacteria identification methods.
Resumo:
A total of 2400 samples of commercial Brazilian C gasoline were collected over a 6-month period from different gas stations in the São Paulo state, Brazil, and analysed with respect to 12 physicochemical parameters according to regulation 309 of the Brazilian Government Petroleum, Natural Gas and Biofuels Agency (ANP). The percentages (v/v) of hydrocarbons (olefins, aromatics and saturated) were also determined. Hierarchical cluster analysis (HCA) was employed to select 150 representative samples that exhibited least similarity on the basis of their physicochemical parameters and hydrocarbon compositions. The chromatographic profiles of the selected samples were measured by gas chromatography with flame ionisation detection and analysed using soft independent modelling of class analogy (SIMCA) method in order to create a classification scheme to identify conform gasolines according to ANP 309 regulation. Following the optimisation of the SIMCA algorithm, it was possible to classify correctly 96% of the commercial gasoline samples present in the training set of 100. In order to check the quality of the model, an external group of 50 gasoline samples (the prediction set) were analysed and the developed SIMCA model classified 94% of these correctly. The developed chemometric method is recommended for screening commercial gasoline quality and detection of potential adulteration. (c) 2007 Elsevier B.V. All rights reserved.
Resumo:
During the analytical method development for BAY 11-7082 ((E)-3-[4-methylphenylsulfonyl]-2-propenenitrile), using HPLC-MS-MS and HPLC-UV, we observed that the protein removal process (both ultrafiltration and precipitation method using organic solvents) prior to HPLC brought about a significant reduction in the concentration of this compound. The use of a structurally similar internal standard, BAY 11-7085 ((E)-3-[4-t-butylphenylsulfonyl]-2-propenenitrile), was not effective in compensating for the loss of analyte as the extent of reduction was different to that of the analyte. We present here a systematic investigation of this problem and a new validated method for the determination of BAY 11-7082. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Purpose: To develop and validate a simple, efficient and reliable Liquid chromatographic-mass spectrometric (LC-MS/MS) method for the quantitative determination of two dermatological drugs, Lamisil® (terbinafine) and Proscar® (finasteride), in split tablet dosage form. Methods: Thirty tablets each of the 2 studied medications were randomly selected. Tablets were weighed and divided into 3 groups. Ten tablets of each drug were kept intact, another group of 10 tablets were manually split into halves using a tablet cutter and weighed with an analytical balance; a third group were split into quarters and weighed. All intact and split tablets were individually dissolved in a water: methanol mixture (4:1), sonicated, filtered and further diluted with mobile phase. Optimal chromatographic separation and mass spectrometric detection were achieved using an Agilent 1200 HPLC system coupled with an Agilent 6410 triple quadrupole mass spectrometer. Analytes were eluted through an Agilent eclipse plus C8 analytical column (150 mm × 4.6 mm, 5 μm) with a mobile phase composed of solvent A (water) containing 0.1% formic acid and 5mM ammonium formate pH 7.5, and solvent B (acetonitrile mixed with water in a ratio A:B 55:45) at a flow rate of 0.8 mL min-1 with a total run time of 12 min. Mass spectrometric detection was carried out using positive ionization mode with analyte quantitation monitored by multiple reaction monitoring (MRM) mode. Results: The proposed analytical method proved to be specific, robust and adequately sensitive. The results showed a good linear fit over the concentration range of 20 - 100 ng mL-1 for both analytes, with a correlation coefficient (r2) ≥ 0.999 and 0.998 for finasteride and terbinafine, respectively. Following tablet splitting, the drug content of the split tablets fell outside of the proxy USP specification for at least 14 halves (70 %) and 34 quarters (85 %) of FIN, as well as 16 halves (80 %) and 37 quarters (92.5 %) of TBN. Mean weight loss, after splitting, was 0.58 and 2.22 % for FIN half- and quarter tablets, respectively, and 3.96 and 4.09 % for TBN half- and quarter tablets,respectively. Conclusion: The proposed LC-MS/MS method has successfully been used to provide precise drug content uniformity of split tablets of FIN and TBN. Unequal distribution of the drug on the split tablets is indicated by the high standard deviation beyond the accepted value. Hence, it is recommended not to split non-scored tablets especially, for those medications with significant toxicity
Resumo:
The increasing demand for fatty acid-free lecithin required modifications in existing purification methods. In this technical note we describe a purification procedure with the following steps: a) homogenization and extraction of yolks obtained from fresh eggs with acetone, b) solubilization with ethanol and solvent elimination and c) repeated solubilization/precipitation with petroleum ether/acetone. This crude extract was chromatographed on neutral alumina, which was exhaustively washed with chloroform before elution with chloroform:methanol, allowing the sequential separation of fatty acids and lecithin. Chromatographic behavior and mass spectra of the product are presented. This fast procedure yields fatty acid-free lecithin at a competitive cost.
Resumo:
The objective of this work was to develop and validate a rapid Reversed-Phase High-Performance Liquid Chromatography method for the quantification of 3,5,3 '-triiodothyroacetic acid (TRIAC) in nanoparticles delivery system prepared in different polymeric matrices. Special attention was given to developing a reliable reproductive technique for the pretreatment of the samples. Chromatographic runs were performed on an Agilent 1200 Series HPLC with a RP Phenomenex (R) Gemini C18 (150 x 4, 6 mm i.d., 5 mu m) column using acetonitrile and triethylamine buffer 0.1% (TEA) (40 : 60 v/v) as a mobile phase in an isocratic elution, pH 5.6 at a flow rate of 1 ml min(-1). TRIAC was detected at a wavelength of 220 nm. The injection volume was 20 mu l and the column temperature was maintained at 35 degrees C. The validation characteristics included accuracy, precision, specificity, linearity, recovery, and robustness. The standard curve was found to have a linear relationship (r(2) - 0.9996) over the analytical range of 5-100 mu g ml(-1) . The detection and quantitation limits were 1.3 and 3.8 mu g ml(-1), respectively. The recovery and loaded TRIAC in colloidal system delivery was nearly 100% and 98%, respectively. The method was successfully applied in polycaprolactone, polyhydroxybutyrate, and polymethylmethacrylate nanoparticles.