Resumo:

OBJECTIVE: This research was aimed to determine the occurrence of Brachyspira (B.) hyodysenteriae in Swiss multiplier pig herds. MATERIALS AND METHODS: In a pilot study a direct real-time polymerase chain reaction (PCR) method for B. hyodysenteriae was compared to culture followed by PCR on 106 samples from three herds. Subsequently 40 multiplier herds were epidemiologically characterized and analysed for the presence of B. hyodysenteriae using direct PCR on 1412 rectal swabs. For external validation 20 swabs obtained from two positive conventional herds were analysed. RESULTS: The comparison of direct PCR with culture followed by PCR resulted in a moderate agreement (kappa index: 0.58). In the two conventional herds, 35% of the samples (7/20) tested positive. Samples from 39 multipliers tested negative. In one multiplier herd, 25% (9/36) of the samples tested PCR positive. Risk factors in the multiplier herd may have been rodents or birds, but not pig purchase. CONCLUSION AND CLINICAL RELEVANCE: B. hyodysenteriae have been detected in a Swiss multiplier herd, which underlines the threat of potential spread by replacement pigs. Consequently, a Brachyspira monitoring programme was established for Swiss multiplier herds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Conventional 2-dimensional radiography uses defined criteria for outcome assessment of apical surgery. However, these radiographic healing criteria are not applicable for 3-dimensional radiography. The present study evaluated the repeatability and reproducibility of new cone-beam computed tomographic (CBCT)-based healing criteria for the judgment of periapical healing 1 year after apical surgery. METHODS CBCT scans taken 1 year after apical surgery (61 roots of 54 teeth in 54 patients, mean age = 54.4 years) were evaluated by 3 blinded and calibrated observers using 4 different indices. Reformatted buccolingual CBCT sections through the longitudinal axis of the treated roots were analyzed. Radiographic healing was assessed at the resection plane (R index), within the apical area (A index), of the cortical plate (C index), and regarding a combined apical-cortical area (B index). All readings were performed twice to calculate the intraobserver agreement (repeatability). Second-time readings were used for analyzing the interobserver agreement (reproducibility). Various statistical tests (Cohen, kappa, Fisher, and Spearman) were performed to measure the intra- and interobserver concurrence, the variability of score ratios, and the correlation of indices. RESULTS For all indices, the rates of identical first- and second-time scores were always higher than 80% (intraobserver Cohen κ values ranging from 0.793 to 0.963). The B index (94.0%) showed the highest intraobserver agreement. Regarding interobserver agreement, the highest rate was found for the B index (72.1%). The Fleiss' κ values for R and B indices exhibited substantial agreement (0.626 and 0.717, respectively), whereas the values for A and C indices showed moderate agreement (0.561 and 0.573, respectively). The Spearman correlation coefficients for R, A, C, and B indices all exhibited a moderate to very strong correlation with the highest correlation found between C and B indices (rs = 0.8069). CONCLUSIONS All indices showed an excellent intraobserver agreement (repeatability). With regard to interobserver agreement (reproducibility), the B index (healing of apical and cortical defects combined) and the R index (healing on the resection plane) showed substantial congruence and thus are to be recommended in future studies when using buccolingual CBCT sections for radiographic outcome assessment of apical surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

During Legs 127 and 128, we found a systematic error in the index property measurements, in that the wet bulk density, grain density, and porosity did not satisfy well-established interrelationships. We have found that an almost constant difference exists between the weight of water lost during drying and the volume of water lost. This discrepancy is independent of volume or water content of the sample. The water losses should be equal because the density of water is close to 1.0 g/cm**3. The pycnometer wet volume measurement has been identified as the source of the systematic error. The wet volume on average is 0.2 cm**3 too low. For the rare cases when the water content is negligible, there is no offset. The source of the wet volume error results from the partial vapor pressure of water in the pycnometer cell. Newly corrected tables of index properties measured during Legs 127 and 128 are included. The corrected index properties are internally consistent. The data are in better agreement with theoretical models that relate the index properties to other physical properties, such as thermal conductivity and acoustic velocity. In future, a standard volume sampler should be used, or the wet volume should be calculated from the dry volume and the water loss by weight.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Postmaster general and National telephone company. Return to an order of the Honourable the House of commons, dated 14 February 1905;--for, copy of memorandum ... setting forth an agreement, dated 2nd February 1905, between the postmaster general and the National telephone company, limited": [v. 1] p. xiii-[xxxviii]

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes index.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To establish a simple method to quantify muscle/fat constituents in cervical muscles of asymptomatic women using magnetic resonance imaging (MRI), and to determine whether there is an age effect within a defined age range. MATERIALS AND METHODS: MRI of the upper cervical spine was performed for 42 asymptomatic women aged 18-45 years. The muscle and fat signal intensities on axial spin echo T1-weighted images were quantitatively classified by taking a ratio of the pixel intensity profiles of muscle against those of intermuscular fat for the rectus capitis posterior major and minor and inferior obliquus capitis muscles bilaterally. Inter- and intra-examiner agreement was scrutinized. RESULTS: The average relative values of fat within the upper cervical musculature compared with intermuscular fat indicated that there were only slight variations in indices between the three sets of muscles. There was no significant correlation between age and fat indices. There were significant differences for the relative fat within the muscle compared with intermuscular fat and body mass index for the right rectus capitis posterior major and right and left inferior obliquus capitis muscles (p = 0.032). Intraclass correlation coefficients for intraobserver agreement ranged from 0.94 to 0.98. Inter-rater agreement of the measurements ranged from 0.75 to 0.97. CONCLUSION: A quantitative measure of muscle/fat constituents has been developed, and results of this study indicate that relative fatty infiltration is not a feature of age in the upper cervical extensor muscles of women aged 18-45 years. (C) 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To validate the WOMAC 3.1 in a touch screen computer format, which applies each question as a cartoon in writing and in speech (QUALITOUCH method), and to assess patient acceptance of the computer touch screen version. Methods: The paper and computer formats of WOMAC 3.1 were applied in random order to 53 subjects with hip or knee osteoarthritis. The mean age of the subjects was 64 years ( range 45 to 83), 60% were male, 53% were 65 years or older, and 53% used computers at home or at work. Agreement between formats was assessed by intraclass correlation coefficients (ICCs). Preferences were assessed with a supplementary questionnaire. Results: ICCs between formats were 0.92 (95% confidence interval, 0.87 to 0.96) for pain; 0.94 (0.90 to 0.97) for stiffness, and 0.96 ( 0.94 to 0.98) for function. ICCs were similar in men and women, in subjects with or without previous computer experience, and in subjects below or above age 65. The computer format was found easier to use by 26% of the subjects, the paper format by 8%, and 66% were undecided. Overall, 53% of subjects preferred the computer format, while 9% preferred the paper format, and 38% were undecided. Conclusion: The computer format of the WOMAC 3.1 is a reliable assessment tool. Agreement between computer and paper formats was independent of computer experience, age, or sex. Thus the computer format may help improve patient follow up by meeting patients' preferences and providing immediate results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The low index Magnesium hydride surfaces, MgH2(001) and MgH2(110), have been studied by ab intio Density Functional Theory (DFT) calculations. It was found that the MgH2(110) surface is more stable than MgH2(001) surface, which is in good agreement with the experimental observation. The H-2 desorption barriers vary depending on the crystalline surfaces that are exposed and also the specific H atom sites involved-they are found to be generally high, due to the thermodynamic stability of the MgH2, system, and are larger for the MgH2(001) surface. The pathway for recombinative desorption of one in-plane and one bridging H atom from the MgH2(110) surface was found to be the lowest energy barrier amongst those computed (172 KJ/mol) and is in good agreement with the experimental estimates. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este estudo teve como objetivo avaliar a concordância para determinação dos tipos faciais (braqui , meso e dolico) entre três análises cefalométricas: RICKETTS (Índice VERT), SIRIWAT; JARABAK (Quociente de JARABAK) e JANSON; WOODSIDE; METAXAS, e duas análises do perfil: LEGAN; BURSTONE e ANÁLISE SUBJETIVA. A amostra compôs-se de 60 indivíduos, sendo 24 do sexo masculino e 36 do sexo feminino. Todos brasileiros, leucodermas e portadores de oclusão normal natural, apresentando um mínimo de quatro das seis chaves de oclusão de ANDREWS. Como critério de exclusão, procedeu-se também à avaliação funcional e dinâmica da oclusão. A utilização da posição natural da cabeça (P.N.C.) e da vertical verdadeira (V.V.) no momento da obtenção das telerradiografias e fotografias laterais compuseram a metodologia do trabalho, como requisito indispensável para efeito de comparação. Após o tratamento estatístico (Kappa), os resultados apontaram, dentre as análises cefalométricas, para uma fraca concordância entre as análises de RICKETTS (Índice VERT) e SIRIWAT; JARABAK (Quociente de JARABAK). Entre as análises do perfil não houve concordância; e quando avaliamos as análises cefalométricas com as do perfil, verificamos que houve concordância entre as análises de JANSON; WOODSIDE; METAXAS e LEGAN; BURSTONE, e entre as análises de RICKETTS e SUBJETIVA DO PERFIL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a microchanneled chirped fiber Bragg grating (MCFBG) is proposed and fabricated through the femtosecond laser-assisted chemical etching. The microchannel (~550 µm) gives access to the external index liquid, thus inducing refractive index (RI) sensitivity to the structure. In the experiment, the transmission bands induced by the reduced effective index in the microchannel region were used to sense the surrounding RI and temperature changes. The experimental results show good agreement with the theoretical analysis. The proposed MCFBG offers enhanced RI sensitivity without degrading the robustness of the device showing good application potential as bio-chemical sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A low-cost high-resolution wavelength-division-multiplexing (WDM) interrogation system operating around 800 nm region with operational bandwidth up to 60 nm and resolution of 12.7 pm utilizing a tilted fiber Bragg grating (TFBG) and a CCDarray detector has been implemented. The system has been evaluated for interrogating fiber Bragg grating based strain, temperature sensors, giving sensitivities of 0.59 pm/µe and 5.6 pm/°C, which are in good agreement with previously reported values. Furthermore, the system has been utilized to detect the refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10¯5. In addition, the vectorial expression of phase match condition and fabrication of TFBG have been discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, a microchanneled chirped fiber Bragg grating (MCFBG) is proposed and fabricated through the femtosecond laser-assisted chemical etching. The microchannel (~550 µm) gives access to the external index liquid, thus inducing refractive index (RI) sensitivity to the structure. In the experiment, the transmission bands induced by the reduced effective index in the microchannel region were used to sense the surrounding RI and temperature changes. The experimental results show good agreement with the theoretical analysis. The proposed MCFBG offers enhanced RI sensitivity without degrading the robustness of the device showing good application potential as bio-chemical sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.