Resumo |
We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5. |
Formato |
application/pdf |
Identificador |
Suo, Rui; Chen, Xianfeng F.; Zhou, Kaiming; Zhang, Lin; Bennion, Ian and Liu, Bo (2008). Tilted fibre Bragg grating based 800nm WDM interrogation system for strain, temperature and refractive index sensing. IN: Third European Workshop on Optical Fibre Sensors. Cutolo, Antonello; Culshaw, Brian and López-Higuera, José Miguel (eds) SPIE proceedings, 6619 . SPIE. |