956 resultados para ACCURATE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report calculations of the band structures and density of states of the four transition metal monoxides MnO, FeO, CoO and NiO using the hybrid density functional sX-LDA ('screened exchange local density approximation'). Late transition metal oxides are prototypical examples of strongly correlated materials, which pose challenges for electronic structure methods. We compare our results with available experimental data and show that our calculations generally yield accurate predictions for the fundamental band gaps and valence bands, in favourable agreement with previously reported theoretical studies. For MnO, the band gaps are still underestimated, suggesting additional many-body effects that are not captured by our screened hybrid functional approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Eight equations of state (EOS) have been evaluated for the simulation of compressible liquid water properties, based on empirical correlations, the principle of corresponding states and thermodynamic relations. The IAPWS-IF97 EOS for water was employed as the reference case. These EOSs were coupled to a modified AUSM+-up convective flux solver to determine flow profiles for three test cases of differing flow conditions. The impact of the non-viscous interaction term discretisation scheme, interfacial pressure method and selection of low-Mach number diffusion were also compared. It was shown that a consistent discretisation scheme using the AUSM+-up solver for both the convective flux and the non-viscous interfacial term demonstrated both robustness and accuracy whilst facilitating a computationally cheaper solution than discretisation of the interfacial term independently by a central scheme. The simple empirical correlations gave excellent results in comparison to the reference IAPWS-IF97 EOS and were recommended for developmental work involving water as a cheaper and more accurate EOS than the more commonly used stiffened-gas model. The correlations based on the principles of corresponding-states and the modified Peng-Robinson cubic EOS also demonstrated a high degree of accuracy, which is promising for future work with generic fluids. Further work will encompass extension of the solver to multiple dimensions and to account for other source terms such as surface tension, along with the incorporation of phase changes. © 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developing noninvasive and accurate diagnostics that are easily manufactured, robust, and reusable will provide monitoring of high-risk individuals in any clinical or point-of-care environment. We have developed a clinically relevant optical glucose nanosensor that can be reused at least 400 times without a compromise in accuracy. The use of a single 6 ns laser (λ = 532 nm, 200 mJ) pulse rapidly produced off-axis Bragg diffraction gratings consisting of ordered silver nanoparticles embedded within a phenylboronic acid-functionalized hydrogel. This sensor exhibited reversible large wavelength shifts and diffracted the spectrum of narrow-band light over the wavelength range λpeak ≈ 510-1100 nm. The experimental sensitivity of the sensor permits diagnosis of glucosuria in the urine samples of diabetic patients with an improved performance compared to commercial high-throughput urinalysis devices. The sensor response was achieved within 5 min, reset to baseline in ∼10 s. It is anticipated that this sensing platform will have implications for the development of reusable, equipment-free colorimetric point-of-care diagnostic devices for diabetes screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transfer matrix method combined with the effective index method is adopted to model the silica-based channel waveguide patterned by UV writing. The effective indexes of the graded index channel waveguides with different dimension are calculated. The maximal error of the effective index is less than 3 x 10(-5). By this method, the number of the guided mode and the dimension range to guide certain modes can be obtained easily. Finally, the dimension range to guide a single mode is presented. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on the semiconductor laser whose spectral line with width is compressed to be less than 1.2Mhz, a system was designed to measure and improve the amplitude and frequency of the real-time microvibration with sinusoidal modulation. real-time microvibration measurement was executed without alignment problem in the interferometry; and low-frequency disturbance of environment could be eliminated. Suggestions were also given to consummate the system. The system also has resistance against the low frequency disturbance of the environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, a charge-pump based phase-locked loop (CPLL) that can achieve fast locking and tiny deviation is proposed and analyzed. A lock-aid circuit is added to achieve fast locking of the CPLL. Besides, a novel differential charge pump which has good current matching characteristics and a PFD with delay cell has been used in this PLL. The proposed PILL circuit is designed based on the 0.35um 2P4M CMOS process with 3.3V/5V supply voltage. HSPICE simulation shows that the lock time of the proposed CPLL can be reduced by over 72% in comparison to the conventional PILL and its charge pump sink and source current mismatch is only 0.008%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a behavior model for PLL Frequency Synthesizer. All the noise sources are modeled with noise voltages or currents in time-domain. An accurate VCO noise model is introduced, including both thermal noise and 1/f noise. The behavioral model can be co-simulated with transistor level circuits with fast speed and provides more accurate phase noise and spurs prediction. Comparison shows that simulation results match very well with measurement results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An accurate description of a radially polarized fundamental Gaussian beam is presented on the basis of complex-source-point spherical waves (CSPSWs). In contrast to other descriptions based on the perturbative Lax series, the expressions for the electromagnetic field components of this description have explicit and simple mathematical forms. Numerical calculations show that both paraxial and fifth-order corrected beam descriptions have large relative error when the diffraction angle is large, while the accurate description based on the CSPSW approach proposed here can give field expressions which satisfy Maxwell's equations with great accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The resonant Raman behavior of the radial breathing modes are very useful to analyze the electronic property of carbon nanotubes. We investigated the resonant behaviors of Stokes and anti-Stokes radial breathing mode and its overtone of a metallic nanotube, and show how to accurately determine the electronic transition energy of carbon nanotubes from radial breathing modes and their overtones. Based on the present results, the previously reported resonant Raman behavior of the radial breathing modes of SWINT bundles can be interpreted very well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-power, highly linear, multi-standard, active-RC filter with an accurate and novel tuning architec-ture is presented. It exhibits 1EEE 802. 11a/b/g (9.5 MHz) and DVB-H (3 MHz, 4 MHz) application. The filter exploits digitally-controlled polysilicon resistor banks and a phase lock loop type automatic tuning system. The novel and complex automatic frequency calibration scheme provides better than 4 comer frequency accuracy, and it can be powered down after calibration to save power and avoid digital signal interference. The filter achieves OIP3 of 26 dBm and the measured group delay variation of the receiver filter is 50 ns (WLAN mode). Its dissipation is 3.4 mA in RX mode and 2.3 mA (only for one path) in TX mode from a 2.85 V supply. The dissipation of calibration consumes 2 mA. The circuit has been fabricated in a 0.35μm 47 GHz SiGe BiCMOS technology; the receiver and transmitter filter occupy 0.21 mm~2 and 0.11 mm~2 (calibration circuit excluded), respectively.