978 resultados para 3D point cloud file as 3Ddxf


Relevância:

40.00% 40.00%

Publicador:

Resumo:

We use the point-source method (PSM) to reconstruct a scattered field from its associated far field pattern. The reconstruction scheme is described and numerical results are presented for three-dimensional acoustic and electromagnetic scattering problems. We give new proofs of the algorithms, based on the Green and Stratton-Chu formulae, which are more general than with the former use of the reciprocity relation. This allows us to handle the case of limited aperture data and arbitrary incident fields. Both for 3D acoustics and electromagnetics, numerical reconstructions of the field for different settings and with noisy data are shown. For shape reconstruction in acoustics, we develop an appropriate strategy to identify areas with good reconstruction quality and combine different such regions into one joint function. Then, we show how shapes of unknown sound-soft scatterers are found as level curves of the total reconstructed field.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper describes a new method for reconstructing 3D surface points and a wireframe on the surface of a freeform object using a small number, e.g. 10, of 2D photographic images. The images are taken at different viewing directions by a perspective camera with full prior knowledge of the camera configurations. The reconstructed surface points are frontier points and the wireframe is a network of contour generators. Both of them are reconstructed by pairing apparent contours in the 2D images. Unlike previous works, we empirically demonstrate that if the viewing directions are uniformly distributed around the object's viewing sphere, then the reconstructed 3D points automatically cluster closely on a highly curved part of the surface and are widely spread on smooth or flat parts. The advantage of this property is that the reconstructed points along a surface or a contour generator are not under-sampled or under-represented because surfaces or contours should be sampled or represented with more densely points where their curvatures are high. The more complex the contour's shape, the greater is the number of points required, but the greater the number of points is automatically generated by the proposed method. Given that the viewing directions are uniformly distributed, the number and distribution of the reconstructed points depend on the shape or the curvature of the surface regardless of the size of the surface or the size of the object. The unique pattern of the reconstructed points and contours may be used in 31) object recognition and measurement without computationally intensive full surface reconstruction. The results are obtained from both computer-generated and real objects. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article presents and assesses an algorithm that constructs 3D distributions of cloud from passive satellite imagery and collocated 2D nadir profiles of cloud properties inferred synergistically from lidar, cloud radar and imager data. It effectively widens the active–passive retrieved cross-section (RXS) of cloud properties, thereby enabling computation of radiative fluxes and radiances that can be compared with measured values in an attempt to perform radiative closure experiments that aim to assess the RXS. For this introductory study, A-train data were used to verify the scene-construction algorithm and only 1D radiative transfer calculations were performed. The construction algorithm fills off-RXS recipient pixels by computing sums of squared differences (a cost function F) between their spectral radiances and those of potential donor pixels/columns on the RXS. Of the RXS pixels with F lower than a certain value, the one with the smallest Euclidean distance to the recipient pixel is designated as the donor, and its retrieved cloud properties and other attributes such as 1D radiative heating rates are consigned to the recipient. It is shown that both the RXS itself and Moderate Resolution Imaging Spectroradiometer (MODIS) imagery can be reconstructed extremely well using just visible and thermal infrared channels. Suitable donors usually lie within 10 km of the recipient. RXSs and their associated radiative heating profiles are reconstructed best for extensive planar clouds and less reliably for broken convective clouds. Domain-average 1D broadband radiative fluxes at the top of theatmosphere(TOA)for (21 km)2 domains constructed from MODIS, CloudSat andCloud–Aerosol Lidar and Infrared Pathfinder Satellite Observations (CALIPSO) data agree well with coincidental values derived from Clouds and the Earth’s Radiant Energy System (CERES) radiances: differences betweenmodelled and measured reflected shortwave fluxes are within±10Wm−2 for∼35% of the several hundred domains constructed for eight orbits. Correspondingly, for outgoing longwave radiation∼65% are within ±10Wm−2.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ability of six scanning cloud radar scan strategies to reconstruct cumulus cloud fields for radiation study is assessed. Utilizing snapshots of clean and polluted cloud fields from large eddy simulations, an analysis is undertaken of error in both the liquid water path and monochromatic downwelling surface irradiance at 870 nm of the reconstructed cloud fields. Error introduced by radar sensitivity, choice of radar scan strategy, retrieval of liquid water content (LWC), and reconstruction scheme is explored. Given an in␣nitely sensitive radar and perfect LWC retrieval, domain average surface irradiance biases are typically less than 3 W m␣2 ␣m␣1, corresponding to 5–10% of the cloud radiative effect (CRE). However, when using a realistic radar sensitivity of ␣37.5 dBZ at 1 km, optically thin areas and edges of clouds are dif␣cult to detect due to their low radar re-ectivity; in clean conditions, overestimates are of order 10 W m␣2 ␣m␣1 (~20% of the CRE), but in polluted conditions, where the droplets are smaller, this increases to 10–26 W m␣2 ␣m␣1 (~40–100% of the CRE). Drizzle drops are also problematic; if treated as cloud droplets, reconstructions are poor, leading to large underestimates of 20–46 W m␣2 ␣m␣1 in domain average surface irradiance (~40–80% of the CRE). Nevertheless, a synergistic retrieval approach combining the detailed cloud structure obtained from scanning radar with the droplet-size information and location of cloud base gained from other instruments would potentially make accurate solar radiative transfer calculations in broken cloud possible for the first time.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Extraction and preconcentration of the model polycyclic aromatic hydrocarbon (PAH), phenanthrene, in aqueous solutions by two different kinds of nonionic ethoxylated alcohols, Tergitol 15-S-7 and Neodol 25-7, as extractants was studied at ambient temperature (22°C). Both surfactants have almost the same numbers of hydrocarbons and ethylene-oxide (EO) units, but differ in the location of the alcohols. Neodol 25-7 is a primary alcohol, while Tergitol 15-S-7 is a secondary one. The extraction process is based on the clouding phenomena of these two nonionic surfactants. Addition of sodium sulfate or sodium phosphate could decrease the cloud point temperatures of the surfactant solutions below the ambient temperatures, so that the cloud-point extraction process could be facilitated. Increasing the salt concentration or decreasing the surfactant concentration could improve the preconcentration factor, which is attributable to the decrease in the volume of surfactant-rich phase. Consequently, the recovery efficiency higher than 96% was achieved for phenanthrene in aqueous solution.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A novel but simple cloud-point extraction (CPE) process is developed to preconcentrate the trace of selected polycyclic aromatic hydrocarbons (PAHs) with the use of the readily biodegradable nonionic surfactant Tergitol 15-S-7 as extractant. The concentrations of PAHs, mixtures of naphthalene and phenanthrene as well as pyrene, in the spiked samples were determined with the new CPE process at ambient temperature (23 °C) followed by high performance liquid chromatography (HPLC) with fluorescence detection. More than 80% of phenanthrene and pyrene, respectively, and 96% of naphthalene initially present in the aqueous solutions with concentrations near or below their aqueous solubilities were recovered using this new CPE process. Importantly Tergitol 15-S-7 does not give any fluorometric signal to interfere with fluorescence detection of PAHs in the UV range. No special washing step is, thus, required to remove surfactant before HPLC analyses. Different experimental conditions were studied. The optimum conditions for the preconcentration and determi nation of these selected PAHs at ambient temperature have been established as the following:  (1) 3 wt % surfactant; (2) addition of 0.5 M Na2SO4; (3) 10 min for equilibration time; and (4) 3000 rpm for centrifugal speed with duration of 10 min.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Triglycerides are reacted in a liquid phase reaction with methanol and a homogeneous basic catalyst. The reaction yields a spatially separated two phase result with an upper located non-polar phase consisting principally of non-polar methyl esters and a lower located phase consisting principally of glycerol and residual methyl esters. The glycerol phase is passed through a strong cationic ion exchanger to remove anions, resulting in a neutral product which is flashed to remove methanol and which is reacted with isobutylene in the presence of a strong acid catalyst to produce glycerol ethers. The glycerol ethers are then added back to the upper located methyl ethyl ester phase to provide an improved biodiesel fuel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cloud point extraction (CPE) was employed for separation and preconcentration prior to the determination of nickel by graphite furnace atomic absorption spectrometry (GFAAS), flame atomic absorption spectrometry (FAAS) or UV-Vis spectrophotometry. Di-2-pyridyl ketone salicyloylhydrazone (DPKSH) was used for the first time as a complexing agent in CPE. The nickel complex was extracted from the aqueous phase using the Triton X-114 surfactant. Under optimized conditions, limits of detection obtained with GFAAS, FAAS and UV-Vis spectrophotometry were 0.14, 0.76 and 1.5 mu g L-1, respectively. The extraction was quantitative and the enrichment factor was estimated to be 27. The method was applied to natural waters, hemodialysis concentrates, urine and honey samples. Accuracy was evaluated by analysis of the NIST 1643e Water standard reference material.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

L’effetto dell’informatica e dell’automazione sulle procedure medico sanitarie si sta manifestando in maniera sempre più ampia, portando notevoli vantaggi per la salute e il benessere di tutti i pazienti e al tempo stesso ponendo sfide sempre più complesse alle istituzioni sanitarie e ai produttori di dispositivi medico-sanitari. Al di là dei meriti del singolo prodotto o tecnologia, esiste un fattore strategico che dovrebbe essere sempre considerato nel momento di progettare un software o un dispositivo da utilizzare in ambito sanitario (da parte dei produttori) o nel momento di pianificare l’acquisto di sistemi medicali o diagnostici complessi (da parte delle istituzioni sanitarie): l’aspetto dell’Integrazione, ovvero la capacità del sistema di inserirsi in maniera semplice, efficace e poco costosa in un Workflow (flusso di lavoro) completamente integrato. Nel primo capitolo di questo elaborato finale è stato fatto un quadro generale sull’organizzazione del flusso di lavoro in radiologia e sono stati trattati i vari standard di comunicazione e scambio dati in ambito clinico, in primis DICOM, HL7 e IHE. L’oggetto del secondo capitolo è l’organizzazione e gli obbiettivi del Dipartimento di Radiologia attuati dal Gruppo Villa Maria (GVM) e il confronto di questi ultimi con il contenuto del documento: ‘Linee guida per l’assicurazione di qualita` in teleradiologia ‘che è stata redatta dal Istituto Superiore di Sanita` destinata ad apportare, non solo ai medici radiologi ed ai TSRM ma anche agli altri professionisti della sanità coinvolti, gli elementi di informazione e di metodo per l’organizzazione della teleradiologia nel rispetto delle esigenze della deontologia medica, della sicurezza del paziente, compreso il consenso, anche per quanto riguarda la radioprotezione, la privacy e la qualità. Nel terzo capitolo sono elencati gli strumenti con cui il Dipartimento di radiologia intende perseguire i suoi obbiettivi. Il quarto capitolo tratta la mia esperienza presso una clinica esterna al GVM, in particolare la clinica Santo Stefano, di Porto Potenza Picena, dove sono stati fatti dei test volti a valutare i tempi di caricamento di esami di TAC e RMN sul cloud di GVM.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a kernel density correlation based nonrigid point set matching method and shows its application in statistical model based 2D/3D reconstruction of a scaled, patient-specific model from an un-calibrated x-ray radiograph. In this method, both the reference point set and the floating point set are first represented using kernel density estimates. A correlation measure between these two kernel density estimates is then optimized to find a displacement field such that the floating point set is moved to the reference point set. Regularizations based on the overall deformation energy and the motion smoothness energy are used to constraint the displacement field for a robust point set matching. Incorporating this non-rigid point set matching method into a statistical model based 2D/3D reconstruction framework, we can reconstruct a scaled, patient-specific model from noisy edge points that are extracted directly from the x-ray radiograph by an edge detector. Our experiment conducted on datasets of two patients and six cadavers demonstrates a mean reconstruction error of 1.9 mm

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Part 5: Service Orientation in Collaborative Networks