976 resultados para volumetric oxygen transfer coefficient
Resumo:
We examined the effects of riparian vegetation removal on algal dynamics and stream nutrient retention efficiency by comparing NH4-N and PO4-P uptake lengths from a logged and an unlogged reach in Riera Major, a forested Mediterranean stream in northeastern Spain. From June to September 1995, we executed 6 short-term additions of N (as NH4Cl) and P (as Na2HPO4) in a 200-m section to measure nutrient uptake lengths. The study site included 2 clearly differentiated reaches in terms of canopy cover by riparian trees: the first 100 m were completely logged (i.e., the logged reach) and the remaining 100 m were left intact (i.e., the shaded reach). Trees were removed from the banks of the logged reach in the winter previous to our sampling. In the shaded reach, riparian vegetation was dominated by alders (Alnus glutinosa). The study was conducted during summer and fall months when differences in light availability between the 2 reaches were greatest because of forest canopy conditions. Algal biomass and % of stream surface covered by algae were higher in the logged than in the shaded reach, indicating that logging had a stimulatory effect on algae in the stream. Overall, nutrient retention efficiency was higher (i.e., shorter uptake lengths) in the logged than in the shaded reach, especially for PO4-P. Despite a greater increase in PO4-P retention efficiency relative to that of NH4-N following logging, retention efficiency for NH4-N was higher than for PO4-P in both study reaches. The PO4-P mass-transfer coefficient was correlated with primary production in both study reaches, indicating that algal activity plays an important role in controlling PO4-P dynamics in this stream. In contrast, the NH4-N mass-transfer coefficient showed a positive relation-ship only with % of algal coverage in the logged reach, and was not correlated with any algal-related parameter in the shaded reach. The lack of correlation with algal production suggests that mechanisms other than algal activity (i.e., microbial heterotrophic processes or abiotic mechanisms) may also influence NH4-N retention in this stream. Overall, this study shows that logging disturbances in small shaded streams may alter in-stream ecological features that lead to changes in stream nutrient retention efficiency. Moreover, it emphasizes that alteration of the tight linkage between the stream channel and the adjacent riparian zone may directly and indirectly impact biogeochemical processes with implications for stream ecosystem functioning.
Resumo:
Työn tavoitteena oli tutkia aaltomaisen profiloinnin vaikutusta suorien jäähdytyskanavien lämmönsiirtoon ja painehäviöön. Erilaisia profiileja oli kymmenen kappaletta ja ne olivat 5mm leveitä ja 30cm pitkiä kukin. Ne laskettiin kolmeulotteisina tapauksina FINFLO-virtausratkaisijalla kolmella eri Reynoldsin luvulla, jotka vastasivat laminaarista, osittain turbulenttista ja lähes kokonaan turbulenttista virtausta. Lämmönsiirtoaine oli kuiva +30°C ilma ja profiloinnin toteutustapa oli toisiaan sivuavat ympyräkaaret kolmella erilaisella säteen arvolla ja kolmella erilaisella aallonpituuden arvolla. Lisäksi laskettiin saman levyisen tasokanavan arvot jokaisella Reynoldsin luvulla kaksiulotteisina tapauksina. Näitä profiloimattomia kanavia pidettiin referenssitapauksina. Tuloksena havaittiin että profiloimalla saadaan yksiselitteisesti suurempi lämpöteho ulos samasta tilavuudesta. Lämmönsiirtokerroin kasvaa profiloinnin avulla parhaimmillaan n. 20% käytetystä turbulenssimallista tai lämmönsiirtokertoimen määritelmästä riippumatta. Painehäviö kasvaa myös aina, mutta kitkakerroin voi hieman pienentyä. Profiilin varsinaisena hyvyyskriteerinä pidettiin lämmönsiirtokertoimen ja kitkakertoimen suhdetta h/f. Se osoittautui riippuvaksi Reynoldsin luvusta ja turbulenssimallista; ASM ja Chien k-έ -mallit ennustavat transitioetäisyyden eri tavalla. Laminaarisilla virtauksilla h/f :n vaihtelu oli vähäistä; suhde vaihteli vain ±5% eri profiilien kesken. ASM-mallilla havaittiin sekundääripyörteilyä, ehkä siksi että se mallintaa anisotrooppisen turbulenssin. Chien k-έ malli ennusti suuremman ja aikaisemmin alkavan turbulenttisuuden kuin ASM. Lisäksi havaittiin mm. että tietyillä profiileilla muodostuu kanavan kapeimpaan kohtaan selvä virtausnopeuden paikallinen minimi seinämän läheisyyden takia.
Resumo:
Tulisijojen tekniikkaan kohdistuu yhä kovempia vaatimuksia sekä kuluttajien että myös erityisesti viranomaismääräysten suunnalta. Tämän työn tarkoituksena on osaltaan luoda pohjaa näiden vaatimusten täyttämiselle. Työn tavoitteena oli määrittää lämmönsiirtokerroin tyypillisen vuolukivirakenteisen tulisijan poskikanavassa savukaasun ja kanavan seinämän välillä. Työ koostuu mittauslaitteen suunnittelusta, käytännön mittauksista ja mittaustulosten analysoinnista teoriaan verrattuina. Työ pohjautuu käytännön mittauksiin kahdella koeuunilla. Mittaukset kohdistuivat uunien poskikanavissa ja poskikanavan seinämissä tapahtuviin lämpötilamuutoksiin. Toisessa koeuunissa mitattiin myös poskikanavan savukaasun lämpötilajakauma. Mittauksilla saatua sekä teoreettisesti määritettyä lämpötilajakaumaa verrattiin toisiinsa. Lämmönsiirtokertoimet määritettiin lämpötilojen ja savukaasun massavirran perusteella. Tuloksena saatiin paikalliset sekä yleispätevät lämmönsiirtokertoimet savukaasun lämpötilan funktiona.
Resumo:
Soodakattilan sulakeon epästationaarinen käyttäytyminen sekä keon pitkä jäähtymisaika alasajon jälkeen ovat aiheuttaneet ongelmia kattilan taloudellisessa käytettävyydessä. Keon käyttäytymisestä on luotu CFD-malleja, joiden tavoitteena on havainnollistaa keon lämpötilajakaumaa ja rakennetta. Mallien ongelmana on se, että niissä huomioidaan vain keon aktiivinen pintakerros. Keon sisäosan rakennetta ja siinä tapahtuvia prosesseja ei toistaiseksi tunneta kunnolla luotettavan, koko keon kattavan mallin luomiseen. Tässä työssä tutkittiin sulakeon käytön aikana havaittuja muutosilmiöitä, jotka vaikuttavat keon rakenteeseen ja ominaisuuksiin sekä tutkittiin ilmiöiden taustalla olevia tekijöitä. Näitä tekijöitä ovat keon sisässä tapahtuvat kemialliset ja fyysiset prosessit, jotka aiheuttavat muutoksia niin lämpöteknisesti kuin fyysisesti sekä ulkoapäin tulevat tekijät, jotka aiheutuvat ajotilanteiden seurauksena tapahtuvista muutoksista. Työn kokeellisena osana luotiin sulakeon jäähtymismalli käyttäen 1-dimensionaalista ADL-mallia. Mallin pohjana käytettiin StoraEnso Oy:ltä Oulun soodakattilan sulakeosta saatua mittausraporttia. ADL-mallin avulla luotiin keon jäähtymiskäyrät lämpötilan ja syvyyden funktiona. Saadut käyrät täsmäsivät hyvin mittausraportin tuloksiin. Mallin avulla keolle saatiin muodostettua energiatase, jonka tuloksena keosta 12 tunnin aikana poistuva lämpövirta pinnalla oli noin 9.8kW/m2 ja pinnan lämmönsiirtokerroin 58.3W/m²°C. Pohjan poistuvaksi lämpövirraksi saatiin 14.1kW/m2 ja lämmönsiirtokertoimeksi 75.4W/m²°C. Termiseksi diffuusiokertoimeksi saatiin 3.9•10-7m²/s.
Resumo:
The objective of the thesis was to examine the possibilities in designing better performing nozzles for the heatset drying oven in Forest Pilot Center. To achieve the objective, two predesigned nozzle types along with the replicas of the current nozzles in the heatset drying oven were tested on a pilot-scale dryer. During the runnability trials, the pilot dryer was installed between the last printing unit and the drying oven. The two sets of predesigned nozzles were consecutively installed in the dryer. Four web tension values and four different impingement air velocities were used and the web behavior during the trial points was evaluated and recorded. The runnability in all trial conditions was adequate or even good. During the heat transfer trials, each nozzle type was tested on at least two different nozzle-to-surface distances and four different impingement air velocities. In a test situation, an aluminum plate fitted with thermocouples was set below a nozzle and the temperature measurement of each block was logged. From the measurements, a heat transfer coefficient profile for the nozzle was calculated. The performance of each nozzle type in tested conditions could now be rated and compared. The results verified that the predesigned simpler nozzles were better than the replicas. For runnability reasons, there were rows of inclined orifices on the leading and trailing edges of the current nozzles. They were believed to deteriorate the overall performance of the nozzle, and trials were conducted to test this hypothesis. The perpendicular orifices and inclined orifices of a replica nozzle were consecutively taped shut and the performance of the modified nozzles was measured as before, and then compared to the performance of the whole nozzle. It was found out, that after a certain nozzle-to-surface distance the jets from the two nozzles would collide, which deteriorates the heat transfer.
Resumo:
In Surface water concentrations of N2O were measured at 37 stations in Guanabara Bay and fluxes estimated across the air-sea interface. Concentrations averaged 8.2 ± 2.2 nmol L-1 and 90% of the stations showed supersaturation averaging 33%. N2O fluxes were estimated using a two-film model which is given by the product of the concentration difference across the film and the gas transfer coefficient (k w). Two parametrizations of k w were used which provided average fluxes of 0.3 and 3.0 µg N m-2 h-1. Flux measurements using floating chambers (not reported here) seem to agree with the upper limit of these estimates.
Resumo:
Electrode kinetics and study of 'transition state' with applied potential in case of [M - antibiotics - cephalothin] system were reported at pH = 7.30 ± 0.01 at suitable supporting electrolyte at 25.0ºC. The M = Co or Ni and antibiotics were doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin and chloramphenicol used as primary ligands and cephalothin as secondary ligand. Kinetic parameters viz. transfer coefficient (a), degree of irreversibility (l), diffusion coefficient (D) and rate constant (k) were determined. The values of a and k varied from 0.41 to 0.59 and 2.60 X 10-3 cm s-1 to 9.67 X 10-3 cm s-1 in case of [Co - antibiotics - cephalothin] system. In case of [Ni - antibiotics - cephalothin], a and k varied from 0.41 to 0.58 and 2.34 X 10-3 cm s-1 to 9.19 X 10-3 cm s-1 respectively confirmed that transition state behaves between oxidant and reductant response to applied potential and it adjusts it self in such a way that the same is located midway between dropping mercury electrode and solution interface. The values of rate constant confirmed the quasireversible nature of electrode processes. The stability constants (logb) of complexes were also determined.
Resumo:
Electrode kinetics and complex formation of Zn(II) using doxycycline, chlortetracycline, oxytetracycline, tetracycline, minocycline, amoxicillin, chloramphenicol and cephaloglycin were reported at pH = 7.30 ± 0.01 in = 1.0 molL-1 NaClO4 used as supporting electrolyte at 25.0°C. Kinetic parameters viz. transfer coefficient (α), degree of irreversibility (λ) and rate constant (k) were determined. The study showed that 'Transition state' behaves between reactant (O) and product (R) response to applied potential. The stability constants varied from 2.14 to 10.31 showing that these drugs or their complexes could be used against Zn toxicity.
Resumo:
Prosessiteollisuudessa tarvitaan usein erilaisia apujärjestelmiä pääprosessin tueksi. Tyypillisiä tällaisia järjestelmiä ovat jäähdytys-, höyry- ja ilmajärjestelmät. Hyödykejärjestelmien kehitys jää helposti pääprosessin varjoon, joka usein johtaa tarpeettoman suuriin hyödykekustannuksiin ja järjestelmien teknisen tilan laskuun. Työn kirjallisuusosassa käsitellään Roal Oy:n fermentointiprosessin kannalta olennaisimpia hyödykevaatimuksia, niiden laskennallista ilmaisua ja vuorovaikutuksia sekä PINCH-menetelmää lämpöenergian hyötykäyttöön. Jäähdytysjärjestelmän osalta käydään läpi merkittävimmät laitetekniset ratkaisut, jäähdytystorni ja lämpöpumppu, toimintaperiaatteineen sekä luonnonvesien käyttö jäähdytykseen. Työn soveltavassa osassa seurattiin Aspergillus, Trichoderma ja Bacillus fermentointeja, joiden pohjalta luotiin kasvatuskohtainen empiirinen malli jäähdytystarpeen arviointiin perustuen sekoitustehoon, kasvatuksen hiilidioksidituottoon ja haihtumisen vaikutukseen. Kasvatuksien aikana seurattiin myös tilavuusperusteista lämmönsiirtokerrointa. Mitattujen lämmönsiirtokertoimien perustella laskettiin ominaislämmöntuottoon perustuva maksimilämpötila käytettävälle jäähdytysvedelle ja fermentorien maksimitilavuudet tunnetuilla kasvatusparametreilla eri lämpöisille jäähdytysvesille. Soveltavassa osassa käydään myös läpi Roalin höyry- ja kuumavesikulutukset ja tärkeimmät käyttökohteet. Mittaustulosten ja mallien perusteella on tehtiin kehitysehdotukset hyödykejärjestelmän optimoimiseksi.
Resumo:
Microreactors have proven to be versatile tools for process intensification. Over recent decades, they have increasingly been used for product and process development in chemical industries. Enhanced heat and mass transfer in the reactors due to the extremely high surfacearea- to-volume ratio and interfacial area allow chemical processes to be operated at extreme conditions. Safety is improved by the small holdup volume of the reactors and effective control of pressure and temperature. Hydrogen peroxide is a powerful green oxidant that is used in a wide range of industries. Reduction and auto-oxidation of anthraquinones is currently the main process for hydrogen peroxide production. Direct synthesis is a green alternative and has potential for on-site production. However, there are two limitations: safety concerns because of the explosive gas mixture produced and low selectivity of the process. The aim of this thesis was to develop a process for direct synthesis of hydrogen peroxide utilizing microreactor technology. Experimental and numerical approaches were applied for development of the microreactor. Development of a novel microreactor was commenced by studying the hydrodynamics and mass transfer in prototype microreactor plates. The prototypes were designed and fabricated with the assistance of CFD modeling to optimize the shape and size of the microstructure. Empirical correlations for the mass transfer coefficient were derived. The pressure drop in micro T-mixers was investigated experimentally and numerically. Correlations describing the friction factor for different flow regimes were developed and predicted values were in good agreement with experimental results. Experimental studies were conducted to develop a highly active and selective catalyst with a proper form for the microreactor. Pd catalysts supported on activated carbon cloths were prepared by different treatments during the catalyst preparation. A variety of characterization methods were used for catalyst investigation. The surface chemistry of the support and the oxidation state of the metallic phase in the catalyst play important roles in catalyst activity and selectivity for the direct synthesis. The direct synthesis of hydrogen peroxide was investigated in a bench-scale continuous process using the novel microreactor developed. The microreactor was fabricated based on the hydrodynamic and mass transfer studies and provided a high interfacial area and high mass transfer coefficient. The catalysts were prepared under optimum treatment conditions. The direct synthesis was conducted at various conditions. The thesis represents a step towards a commercially viable direct synthesis. The focus is on the two main challenges: mitigating the safety problem by utilization of microprocess technology and improving the selectivity by catalyst development.
Resumo:
This study combines several projects related to the flows in vessels with complex shapes representing different chemical apparata. Three major cases were studied. The first one is a two-phase plate reactor with a complex structure of intersecting micro channels engraved on one plate which is covered by another plain plate. The second case is a tubular microreactor, consisting of two subcases. The first subcase is a multi-channel two-component commercial micromixer (slit interdigital) used to mix two liquid reagents before they enter the reactor. The second subcase is a micro-tube, where the distribution of the heat generated by the reaction was studied. The third case is a conventionally packed column. However, flow, reactions or mass transfer were not modeled. Instead, the research focused on how to describe mathematically the realistic geometry of the column packing, which is rather random and can not be created using conventional computeraided design or engineering (CAD/CAE) methods. Several modeling approaches were used to describe the performance of the processes in the considered vessels. Computational fluid dynamics (CFD) was used to describe the details of the flow in the plate microreactor and micromixer. A space-averaged mass transfer model based on Fick’s law was used to describe the exchange of the species through the gas-liquid interface in the microreactor. This model utilized data, namely the values of the interfacial area, obtained by the corresponding CFD model. A common heat transfer model was used to find the heat distribution in the micro-tube. To generate the column packing, an additional multibody dynamic model was implemented. Auxiliary simulation was carried out to determine the position and orientation of every packing element in the column. This data was then exported into a CAD system to generate desirable geometry, which could further be used for CFD simulations. The results demonstrated that the CFD model of the microreactor could predict the flow pattern well enough and agreed with experiments. The mass transfer model allowed to estimate the mass transfer coefficient. Modeling for the second case showed that the flow in the micromixer and the heat transfer in the tube could be excluded from the larger model which describes the chemical kinetics in the reactor. Results of the third case demonstrated that the auxiliary simulation could successfully generate complex random packing not only for the column but also for other similar cases.
Resumo:
Two-photon excited (TPE) side illumination fluorescence studies in a Rh6G-RhB dye mixture doped polymer optical fiber (POF) and the effect of energy transfer on the attenuation coefficient is reported. The dye doped POF is pumped sideways using 800 nm, 70 fs laser pulses from a Ti:sapphire laser, and the TPE fluorescence emission is collected from the end of the fiber for different propagation distances. The fluorescence intensity of RhB doped POF is enhanced in the presence of Rh6G as a result of energy transfer from Rh6G to RhB. Because of the reabsorption and reemission process in dye molecules, an effective energy transfer is observed from the shorter wavelength part of the fluorescence spectrum to the longer wavelength part as the propagation distance is increased in dye doped POF. An energy transfer coefficient is found to be higher at shorter propagation distances compared to longer distances. A TPE fluorescence signal is used to characterize the optical attenuation coefficient in dye doped POF. The attenuation coefficient decreases at longer propagation distances due to the reabsorption and reemission process taking place within the dye doped fiber as the propagation distance is increased.
Resumo:
Dins dels processos de recuperació de metalls de dissolucions diluïdes s'ha realitzat un estudi del procés d'extracció d'or i de zinc mitjançant resines amberlite XAD-2 impregnades amb sulfur de triisobutil fosfina (TIBPS) i àcid di-(2-etilhexil) fosfòric (DEHPA) respectivament. S'ha realitzat un estudi de l'equilibri de l'adsorció d'espècies metàl·liques d'aquests metalls amb les resines indicades anteriorment. Amb la metodologia emprada per a la determinació dels punts d'equilibri dels experiments en batch i en columna, s'ha vist que una única isoterma no podia descriure el fenomen global d'equilibri i que en funció de la metodologia emprada s'obtenien isotermes diferents. Es va introduir una nova variable per poder explicar el fenomen observat, i per tant, amb aquesta nova variable l'equació de la isoterma es converteix amb l'equació d'una supèrfície que s'ha definit com a Superfície d'Equilibri. S'han determinat les equacions de les Suprfícies d'Equilibri dels sistemes d'adsorció estudiats (Au(III) TIBPS/XAD-2 i Zn(II) DEHPA/XAD-2) observan una bona coincidència de tots els punts d'equilibri obtinguts sobre la superfície, així com, un bon ajust de totes les isotermes obtingudes en funció de les diferents metodologies emprades sobre les respectives superfícies d'equilibri. Aquest nou concepte generalitza el concepte d'isoterma d'un procés d'adsorció. Fimalment, s'ha plantejat un model matemàtic d'adsorció per a determinar el coeficient efectiu de difusió (De) i el coeficient de transferància de matèria (kf) per ambdós sistemes d'adsorció estudiats mitjançant l'aplicació del model de difusió de sòlid homogeni (HSDM), utilitzant com a condició de contorn en el model la isoterma de Langmuir obtinguda mitjançant els experiments en columna de llit fix i emprant també l'equació obtinguda mitjançant el nou concepte de Superfície d'Equilibri. Els resultats obtinguts són molt satisfactoris, per tant, es pot concloure que la Superfície d'Equilibri és una bona eina per a descriure l'equilibri en els processos d'adsorció d'or i zinc amb les resines amberlite XAD-2 impregnades amb TIBPS i DEHPA respectivament.
Resumo:
We investigate the question of how many facets are needed to represent the energy balance of an urban area by developing simplified 3-, 2- and 1-facet versions of a 4-facet energy balance model of two-dimensional streets and buildings. The 3-facet model simplifies the 4-facet model by averaging over the canyon orientation, which results in similar net shortwave and longwave balances for both wall facets, but maintains the asymmetry in the heat fluxes within the street canyon. For the 2-facet model, on the assumption that the wall and road temperatures are equal, the road and wall facets can be combined mathematically into a single street-canyon facet with effective values of the heat transfer coefficient, albedo, emissivity and thermodynamic properties, without further approximation. The 1-facet model requires the additional assumption that the roof temperature is also equal to the road and wall temperatures. Idealised simulations show that the geometry and material properties of the walls and road lead to a large heat capacity of the combined street canyon, whereas the roof behaves like a flat surface with low heat capacity. This means that the magnitude of the diurnal temperature variation of the street-canyon facets are broadly similar and much smaller than the diurnal temperature variation of the roof facets. Consequently, the approximation that the street-canyon facets have similar temperatures is sound, and the road and walls can be combined into a single facet. The roof behaves very differently and a separate roof facet is required. Consequently, the 2-facet model performs similarly to the 4-facet model, while the 1-facet model does not. The models are compared with previously published observations collected in Mexico City. Although the 3- and 2-facet models perform better than the 1-facet model, the present models are unable to represent the phase of the sensible heat flux. This result is consistent with previous model comparisons, and we argue that this feature of the data cannot be produced by a single column model. We conclude that a 2-facet model is necessary, and for numerical weather prediction sufficient, to model an urban surface, and that this conclusion is robust and therefore applicable to more general geometries.
Resumo:
The high thermal storage capacity of phase change material (PCM) can reduce energy consumption in buildings through energy storage and release when combined with renewable energy sources, night cooling, etc. PCM boards can be used to absorb heat gains during daytime and release heat at night. In this paper, the thermal performance of an environmental chamber fitted with phase change material boards has been investigated. During a full-cycle experiment, i.e. charging–releasing cycle, the PCM boards on a wall can reduce the interior wall surface temperature during the charging process, whereas the PCM wall surface temperature is higher than that of the other walls during the heat releasing process. It is found that the heat flux density of the PCM wall in the melting zone is almost twice as large as that of ordinary wall. Also, the heat-insulation performance of a PCM wall is better than that of an ordinary wall during the charging process, while during the heat discharging process, the PCM wall releases more heat energy. The convective heat transfer coefficient of PCM wall surface calculated using equations for a normal wall material produces an underestimation of this coefficient. The high convective heat transfer coefficient for a PCM wall is due to the increased energy exchange between the wall and indoor air.