978 resultados para ultrasonography, doppler


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The identification of pre-clinical microvascular damage in hypertension by non-invasive techniques has proved frustrating for clinicians. This proof of concept study investigated whether entropy, a novel summary measure for characterizing blood velocity waveforms, is altered in participants with hypertension and may therefore be useful in risk stratification.

Methods: Doppler ultrasound waveforms were obtained from the carotid and retrobulbar circulation in 42 participants with uncomplicated grade 1 hypertension (mean systolic/diastolic blood pressure (BP) 142/92 mmHg), and 26 healthy controls (mean systolic/diastolic BP 116/69 mmHg). Mean wavelet entropy was derived from flow-velocity data and compared with traditional haemodynamic measures of microvascular function, namely the resistive and pulsatility indices.

Results: Entropy, was significantly higher in control participants in the central retinal artery (CRA) (differential mean 0.11 (standard error 0.05 cms(-1)), CI 0.009 to 0.219, p 0.017) and ophthalmic artery (0.12 (0.05), CI 0.004 to 0.215, p 0.04). In comparison, the resistive index (0.12 (0.05), CI 0.005 to 0.226, p 0.029) and pulsatility index (0.96 (0.38), CI 0.19 to 1.72, p 0.015) showed significant differences between groups in the CRA alone. Regression analysis indicated that entropy was significantly influenced by age and systolic blood pressure (r values 0.4-0.6). None of the measures were significantly altered in the larger conduit vessel.

Conclusion: This is the first application of entropy to human blood velocity waveform analysis and shows that this new technique has the ability to discriminate health from early hypertensive disease, thereby promoting the early identification of cardiovascular disease in a young hypertensive population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A counterintuitive scheme to produce ultracold hydrogen via fragmentation of laser cooled diatomic hydrides is presented where the final atomic H temperature is inversely proportional to the mass of the molecular parent. In addition, the critical density for formation of a Bose-Einstein condensate (BEC) at a fixed temperature is reduced by a factor (mH/mMH)3/2 over directly cooled hydrogen atoms. The narrow Feshbach resonances between a S01 atom and hydrogen are well suited to a tiny center of mass energy release necessary during fragmentation. With the support of ab initio quantum chemistry, it is demonstrated that BaH is an ideal diatomic precursor that can be laser cooled to a Doppler temperature of ∼26μK with just two rovibronic transitions, the simplest molecular cooling scheme identified to date. Preparation of a hydrogen atom gas below the critical BEC temperature Tc is feasible with present cooling technology, with optical pulse control of the condensation process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine whether an elevated fetal umbilical artery Doppler (UAD) pulsatility index (PI) at 28 weeks' gestation, in the absence of fetal growth restriction (FGR) and prematurity, is associated with adverse neurocognitive outcome in children aged 12 years.

METHODS: Prospective cohort study, comparing children with a normal fetal UAD PI (<90th centile) (n=110) and those with an elevated PI (≥90th centile) (n=40). UAD was performed at 28, 32 and 34 weeks gestation. At 12 years of age, all children were assessed under standardised conditions at Queen's University, Belfast, UK to determine cognitive and behavioural outcomes using the British Ability Score-II and Achenbach Child Behavioural Checklist Parent Rated Version under standardised conditions. Regression analysis was performed, controlling for confounders such as gender, socioeconomic status and age at assessment.

RESULTS: The mean age of follow-up was 12.4 years (±0.5 SD) with 44% of children male (n=63). When UAD was assessed at 28 weeks, the elevated fetal UAD group had lower scores in cognitive assessments of information processing and memory. Parameters included (1) recall of objects immediate verbal (p=0.002), (2) delayed verbal (p=0.008) and (3) recall of objects immediate spatial (p=0.0016). There were no significant differences between the Doppler groups at 32 or 34 weeks' gestation.

CONCLUSIONS: An elevated UAD PI at 28 weeks' gestation in the absence of FGR or prematurity is associated with lower scores of declarative memory in children aged 12 years. A potential explanation for this is an element of placental insufficiency in the presence of the appropriately grown fetus, which affects the development of the fetal hippocampus and information processing and memory long-term. These findings, however, had no impact on overall academic ability, mental processing and reasoning or overall behavioural function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evaluation of blood-flow Doppler ultrasound spectral content is currently performed on clinical diagnosis. Since mean frequency and bandwidth spectral parameters are determinants on the quantification of stenotic degree, more precise estimators than the conventional Fourier transform should be seek. This paper summarizes studies led by the author in this field, as well as the strategies used to implement the methods in real-time. Regarding stationary and nonstationary characteristics of the blood-flow signal, different models were assessed. When autoregressive and autoregressive moving average models were compared with the traditional Fourier based methods in terms of their statistical performance while estimating both spectral parameters, the Modified Covariance model was identified by the cost/benefit criterion as the estimator presenting better performance. The performance of three time-frequency distributions and the Short Time Fourier Transform was also compared. The Choi-Williams distribution proved to be more accurate than the other methods. The identified spectral estimators were developed and optimized using high performance techniques. Homogeneous and heterogeneous architectures supporting multiple instruction multiple data parallel processing were essayed. Results obtained proved that real-time implementation of the blood-flow estimators is feasible, enhancing the usage of more complex spectral models on other ultrasonic systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work described here is part of a research program aiming to increase the sensitivity to disease detection using Doppler ultrasound by reducing the effects to the measurement procedure on the estimation of blood velocity and detection of flow disturbance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os sinais de fluxo sanguíneo são sinais aleatórios que, além de variarem de individuo para individuo, variam também consoante o ciclo cardíaco em análise. Sendo o diagnóstico de patologias cardiovasculares fortemente baseado em sinais de ultrassom Doppler representados em forma de espectrograma, e tendo em consideração que o ruído do tipo speckle é parte integrante dos sinais ultrassónicos, torna-se vital a pesquisa de métodos de eliminação desse tipo de ruído e de caracterização precisa dos parâmetros desses sinais biomédicos por forma a melhorar a qualidade do diagnóstico clínico. Com esta tese pretende-se desenvolver uma ferramenta computacional que possibilite a extração automática dos parâmetros pico sistólico, fim de diástole e de outros eventos clinicamente relevantes de sinais Doppler de fluxo sanguíneo, com especial atenção ao sinal proveniente da artéria carótida. Esta investigação vem na continuidade de um projeto realizado anteriormente no Grupo de Processamento de Sinal Biomédico da Universidade do Algarve, no qual foi desenvolvido um sistema de redução de ruído de espectrogramas Doppler. Este sistema de remoção de ruído será aqui aplicado e melhorado. Para a deteção e extração automática de parâmetros clínicos, foi desenvolvido um algoritmo que recebe um sinal de Doppler e que tem como saída o espectrograma livre de ruído e os valores dos parâmetros clínicos calculados. O algoritmo desenvolvido está dividido em três partes principais. A primeira, consiste na transformada do sinal para os domínios tempo-frequência para a criação do espectrograma e na aplicação de uma metodologia de remoção do ruído do tipo speckle do espectrograma. A fase seguinte é a criação de um sinal bidimensional a partir do espectrograma, o qual é criado para possibilitar a sua caraterização. Por último, desenvolveu-se uma fase dedicada à caracterização do sinal, tendo como principais funções a deteção dos eventos clínicos de pico sistólico, fim de diástole, índice de pulsação, índice de resistência e ratio sístole-diástole. A refinação de atuação de cada uma das três partes mencionadas pode ser ajustada pelo utilizador, tendo para o efeito sido desenvolvido uma interface gráfica na qual a interação do utilizador com o programa global é facilitada. Versatilidade e eficácia do algoritmo desenvolvido foram demonstradas pelos resultados obtidos com três sinais de Doppler de diferentes origens: um de origem clínica, um sinal de fluxo em artéria carótida simulado experimentalmente recorrendo a phantoms, e um sinal de fluxo simulado computacionalmente. Para cada um destes sinais são apresentados os valores das variáveis considerados preferenciais para o ajuste ao respetivo sinal e os respetivos espetros de ruído reduzido. Os resultados da extração automática dos parâmetros clínicos dos três sinais, comprovou a utilidade clínica do algoritmo desenvolvido.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper compares a carrier tracking scenario when a received Global Positioning System (GPS) signal has low Doppler frequency. It is shown that if the Numerically Controlled Oscillator (NCO) is quantized to 1 bit, the carrier tracking loop is unable to keep track of the incoming signal which leaves the tracking loop oscillating between the upper and lower bounds of the tracking loop bandwidth. One way of overcoming this problem is presented and compared with another existing solution, found in the literature, providing comparative results from the use of real-recorded off the air GPS L1 signals. Results show that the proposed method performs better tracking performance compared with the existing solution which it requires much less hardware complexity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine the sensitivity of ultrasonography in screening for foetal malformations in the pregnant women of the Swiss Canton of Vaud. STUDY DESIGN: Retrospective study over a period of five years. METHOD: We focused our study on 512 major or minor clinically relevant malformations detectable by ultrasonography. We analysed the global sensitivity of the screening and compared the performance of the tertiary centre with that of practitioners working in private practice or regional hospitals. RESULTS: Among the 512 malformations, 181 (35%) involved the renal and urinary tract system, 137 (27%) the heart, 71 (14%) the central nervous system, 50 (10%) the digestive system, 42 (8%) the face and 31 (6%) the limbs. Global sensitivity was 54.5%. The lowest detection rate was observed for cardiac anomalies, with only 23% correct diagnoses. The tertiary centre achieved a 75% detection rate in its outpatient clinic and 83% in referred patients. Outside the referral centre, the diagnostic rate attained 47%. CONCLUSIONS: Routine foetal examination by ultrasonography in a low-risk population can detect foetal structural abnormalities. Apart from the diagnosis of cardiac abnormalities, the results in the Canton of Vaud are satisfactory and justify routine screening for malformations in a low-risk population. A prerequisite is continuing improvement in the skills of ultrasonographers through medical education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work parameters of Mg-doped GaN samples were studied using positron annihilation spectroscopy and analyzed. It is shown that gallium vacancies exist in an unintentionally doped sample. Next, the sample with higher concentration of Mg and low growth temperature contains vacancy clusters. In case of low concentration of Mg the growth temperature does not affect the formation of defects. Analog electronics can be replaced by a modern digital device. While promising a high quantity of benefits, the performance of these digitizers requires thorough adjustment. A 14-bit two channel digitizer has been tested in order to achieve better performance than the one of a traditional analog setup, and the adjustment process is described. It has been shown that the digital device is unable to achieve better energy resolution, but it is quite close to the corresponding attribute of the available analog system, which had been used for measurements in Mg-doped GaN.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examined factors contributing to the differences in left ventricular mass as measured by Doppler echocardiography in children. Fourteen boys (10.3 ± 0.3 years of age) and 1 1 girls (10.5 ± 0.4 years of age) participated in the study. Height and weight were measured, and relative body fat was determined from the measurement of skinfold thickness according to Slaughter et al. (1988). Lean Body Mass was then calculated by subtracting the fat mass from the total body mass. Sexual maturation was self-assessed using the stages of sexual maturation by Tanner (1962). Both pubic hair development and genital (penis or breast for boys and girls respectively) development were used to determine sexual maturation. Carotid Pulse pressure was assessed by applanation tomometry in the left carotid artery. Cardiac mass was measured by Doppler Echocardiography. Images of cardiac structures were taken using B-Mode and were then translated to M- Mode. The dimensions at the end diastole were obtained at the onset of the QRS complex of the electrocardiogram in a plane through a standard position. Measurements included: (a) the diameter of the left ventricle at the end diastole was measured from the septum edge to the endocardium mean border, (b) the posterior wall was measured as the distance from to anterior wall to the epicardium surface, and (c) the interventricular septum was quantified as the distance from the surface of the left ventricle border to the right ventricle septum surface. Systolic time measurements were taken at the peak of the T-wave of the electrocardiogram. Each measurement was taken three to five times before averaging. Average values were used to calculate cardiac mass using the following equation (Deveraux et al. 1986). Weekly physical activity metabolic equivalent was calculated using a standardize activity questionnaire (Godin and Shepard, 1985) and peakV02 was measured on a cycloergometer. There were no significant differences in cardiovascular mesurements between boys and girls. Left ventricular mass was correlated (p<0.05) with size, maturation, peakV02 and physical activity metabolic equivalent. In boys, lean body mass alone explained 36% of the variance in left ventricular mass while weight was the single strongest predictor of left ventricular mass (R =0.80) in girls. Lean body mass, genital developemnt and physical activity metabolic equivalent together explained 46% and 81% in boys and girls, respectively. However, the combination of lean body mass, genital development and peakV02 (ml kgLBM^ min"') explained up to 84% of the variance in left ventricular mass in girls, but added nothing in boys. It is concluded that left ventricular mass was not statistically different between pre-adolescent boys and girls suggesting that hormonal, and therefore, body size changes in adolescence have a main effect on cardiac development and its final outcome. Although body size parameters were the strongest correlates of left ventricular mass in this pre-adolescent group of children, to our knowledge, this is the first study to report that sexual maturation, as well as physical activity and fitness, are also strong associated with left ventricular mass in pre-adolescents, especially young females. Arterial variables, such as systolic blood pressure and carotid pulse pressure, are not strong determinants of left ventricular mass in this pre-adolescent group. In general, these data suggest that although there is no gender differences in the absolute values of left ventricular mass, as children grow, the factors that determine cardiac mass differ between the genders, even in the same pre-adolescent age.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nous avons mené une étude prospective randomisée dans le but de comparer l'effet de l'irrigation du cathéter de type PICC avec deux types d'anticoagulants: Héparine standard et Tinzaparine, une héparine de faible poids moléculaire. Notre étude s'adresse aux patients de la clinique externe d'oncologie de l'hôpital Maisonneuve-Rosemont. Entre début Mai 2005 et Mars 2008, nous avons recruté 131 patients dont 70 ont été randomisés. Parmi les 61 patients exclus, 23 n'ont pas rencontré les critères d'inclusion, 30 ont refusé de participer et 8 ne sont pas inclus pour d'autres raisons. Sur les 70, 36 sujets sont randomisés dans le groupe Héparine standard et 34 dans le groupe Tinzaparine. La population en intention de traiter comprend 65 sujets dont 32 dans le groupe Héparine standard et 33 dans le groupe Tinzaparine. Le médicament a été administré pendant un mombre maximal de 30 jours et les sujets ont été suivis pendant 90 jours. La thrombose veineuse associée au cathéter (TVAC) a été objectivée par une phlébographie ou une échographie-Doppler à la fin de la période de 30 jours suivant l'installation du cathéter. L'incidence de la TVAC sur 30 jours est de 14,39 par 1000 cathéter-jours (IC à 95%:[9,0;19,79]/1000 cathéter-jours ou 41,5% (27/65). L'incidence de la thrombose veineuse profonde (TVP) symptômatique du membre supérieur sur la période de suivi de 90 jours est de 0,41 par 1000 cathéter-jours (IC à 95%:[0,08;0,81]/1000 cathéter-jours ou 3% (2/65). Nous n'avons observé aucune différence entre les deux groupes par rapport à la fréquence de la TVAC ni de la TVP. Nous ne pouvons conclure à une différence dans l'efficacité de la Tinzaparine par rapport à l'Héparine standard dans la prévention de la TVAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectif: Évaluer l'efficacité du dépistage de l’hypertension gestationnelle par les caractéristiques démographiques maternelles, les biomarqueurs sériques et le Doppler de l'artère utérine au premier et au deuxième trimestre de grossesse. Élaborer des modèles prédictifs de l’hypertension gestationnelle fondées sur ces paramètres. Methods: Il s'agit d'une étude prospective de cohorte incluant 598 femmes nullipares. Le Doppler utérin a été étudié par échographie transabdominale entre 11 +0 à 13 +6 semaines (1er trimestre) et entre 17 +0 à 21 +6 semaines (2e trimestre). Tous les échantillons de sérum pour la mesure de plusieurs biomarqueurs placentaires ont été recueillis au 1er trimestre. Les caractéristiques démographiques maternelles ont été enregistrées en même temps. Des courbes ROC et les valeurs prédictives ont été utilisés pour analyser la puissance prédictive des paramètres ci-dessus. Différentes combinaisons et leurs modèles de régression logistique ont été également analysés. Résultats: Parmi 598 femmes, on a observé 20 pré-éclampsies (3,3%), 7 pré-éclampsies précoces (1,2%), 52 cas d’hypertension gestationnelle (8,7%) , 10 cas d’hypertension gestationnelle avant 37 semaines (1,7%). L’index de pulsatilité des artères utérines au 2e trimestre est le meilleur prédicteur. En analyse de régression logistique multivariée, la meilleure valeur prédictive au 1er et au 2e trimestre a été obtenue pour la prévision de la pré-éclampsie précoce. Le dépistage combiné a montré des résultats nettement meilleurs comparés avec les paramètres maternels ou Doppler seuls. Conclusion: Comme seul marqueur, le Doppler utérin du deuxième trimestre a la meilleure prédictive pour l'hypertension, la naissance prématurée et la restriction de croissance. La combinaison des caractéristiques démographiques maternelles, des biomarqueurs sériques maternels et du Doppler utérin améliore l'efficacité du dépistage, en particulier pour la pré-éclampsie nécessitant un accouchement prématuré.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La débitmétrie au laser à effet Doppler (LDF) constitue une méthode prometteuse et non-invasive pour l'étude du débit sanguin local dans l'œil. Cette technique est basée sur un changement de fréquence subi par la lumière lors du mouvement des globules rouges dans les vaisseaux. Une nouvelle sonde LDF a été testée pour sa sensibilité à évaluer la circulation rétinienne/choroïdienne sous des conditions hypercapniques et en présence de diverses substances vasoactives ou suivant la photocoagulation des artères rétiniennes chez le rat. Après dilatation pupillaire, la sonde LDF a été placée en contact avec la cornée de rats anesthésiés et parallèle à l'axe optique. L'hypercapnie a été provoquée par inhalation de CO2 (8% dans de l'air médical), alors que les agents pharmacologiques ont été injectés de façon intravitréenne. La contribution relative à la circulation choroïdienne a été évaluée à la suite de la photocoagulation des artères rétiniennes. Le débit sanguin s'est trouvé significativement augmenté à la suite de l'hypercanie (19%), de l'adénosine (14%) ou du nitroprusside de sodium (16%) comparativement au niveau de base, alors que l'endothéline-1 a provoqué une baisse du débit sanguin (11%). La photocoagulation des artères rétiniennes a significativement diminué le débit sanguin (33%). Des mesures en conditions pathologiques ont ensuite été obtenues après l'injection intravitréenne d'un agoniste sélectif du récepteur B1 (RB1). Ce récepteur des kinines est surexprimé dans la rétine des rats rendus diabétiques avec la streptozotocine (STZ) en réponse à l'hyperglycémie et au stress oxydatif. Les résultats ont montré que le RB1 est surexprimé dans la rétine chez les rats diabétiques-STZ à 4 jours et 6 semaines. À ces moments, le débit sanguin rétinien/choroïdien a été significativement augmenté (15 et 18 %) après l'injection de l'agoniste, suggérant un effet vasodilatateur des RB1 dans l'œil diabétique. Bien que la circulation choroïdienne contribue probablement au signal LDF, les résultats démontrent que le LDF représente une technique efficace et non-invasive pour l'étude de la microcirculation rétinienne in-vivo en continu. Cette méthode peut donc être utilisée pour évaluer de façon répétée les réponses du débit sanguin pendant des modifications métaboliques ou pharmacologiques dans des modèles animaux de maladies oculaires.