961 resultados para stent-grafts


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Nerve transfers or graft repairs in upper brachial plexus palsies are 2 available options for elbow flexion recovery. OBJECTIVE: To assess outcomes of biceps muscle strength when treated either by grafts or nerve transfer. METHODS: A standard supraclavicular approach was performed in all patients. When roots were available, grafts were used directed to proximal targets. Otherwise, a distal ulnar nerve fascicle was transferred to the biceps branch. Elbow flexion strength was measured with a dynamometer, and an index comparing the healthy arm and the operated-on side was developed. Statistical analysis to compare both techniques was performed. RESULTS: Thirty-five patients (34 men) were included in this series. Mean age was 28.7 years (standard deviation, 8.7). Twenty-two patients (62.8%) presented with a C5-C6 injury, whereas 13 patients (37.2%) had a C5-C6-C7 lesion. Seventeen patients received reconstruction with grafts, and 18 patients were treated with a nerve transfer from the ulnar nerve to the biceps. The trauma to surgery interval (mean, 7.6 months in both groups), strength in the healthy arm, and follow-up duration were not statistically different. On the British Medical Research Council muscle strength scale, 8 of 17 (47%) patients with a graft achieved >= M3 biceps flexion postoperatively, vs 16 of 18 (88%) post nerve transfers (P = .024). This difference persisted when a muscle strength index assessing improvement relative to the healthy limb was used (P = .031). CONCLUSION: The results obtained from ulnar nerve fascicle transfer to the biceps branch were superior to those achieved through reconstruction with grafts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The National Institute for Clinical Excellence (NICE) guidelines recommend the use of bare-metal stents (BMS) in non-complex lesions with a low risk of restenosis (diameter a parts per thousand yen3 mm and lesion length a parts per thousand currency sign15 mm) and the use of drug-eluting stents (DES) in more complex lesions with a high risk of restenosis (diameter < 3.0 mm or lesion length > 15 mm). However, the guidelines were created based on studies evaluating BMS and DES only. We performed an analysis of patients undergoing non-urgent percutaneous coronary intervention with the novel endothelial cell capturing stent (ECS). The ECS is coated with CD34(+) antibodies that attract circulating endothelial progenitor cells to the stent surface, thereby accelerating the endothelialization of the stented area. We analyzed all patients enrolled in the worldwide e-HEALING registry that met the NICE criteria for either low-risk or high-risk lesions and were treated with a parts per thousand yen1 ECS. The main study outcome was target vessel failure (TVF) at 12-month follow-up, defined as the composite of cardiac death or MI and target vessel revascularization (TVR). A total of 4,241 patients were assessed in the current analysis. At 12-month follow-up, TVF occurred in 7.0% of the patients with low-risk lesions and in 8.8% of the patients with high-risk lesions (p = 0.045). When evaluating the diabetic patients versus the non-diabetic patients per risk group, no significant differences were found in TVF, MI or TVR in either risk group. The ECS shows good clinical outcomes in lesions carrying either a high or a low risk of restenosis according to the NICE guidelines with comparable rates of cardiac death, myocardial infarction, and stent thrombosis. The TVF rate with ECS was slightly higher in patients with high-risk lesions, driven by higher clinically driven TLR. The risk of restenosis with ECS in patients carrying high-risk lesions needs to be carefully considered relative to other risks associated with DES. Furthermore, the presence of diabetes mellitus did not influence the incidence of TVF in either risk group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Os estudos com stents farmacológicos têm avaliado predominantemente populações masculinas de descendência europeia. O estudo de braço único SPIRIT Women avalia o stent eluidor de everolimus XIENCE TM V em lesões de novo complexas em uma população feminina do mundo real, incluindo pacientes latino-americanas. Esta análise permite compreender como essa população responde ao implante de stent, comparativamente a pacientes não-latino-americanas. MÉTODOS: Das 1.572 pacientes matriculadas em 73 locais fora dos Estados Unidos, 138 (9%) foram recrutadas na Argentina, no Brasil e na Venezuela. RESULTADOS: As lesões-alvo tinham diâmetro de referência do vaso entre 2,25 mm e 4 mm e extensão da lesão ≤ 28 mm. As características basais foram semelhantes entre os grupos, com exceção de maior prevalência de hipertensão arterial, infarto do miocárdio (IM) de parede anterior e história familiar de doença arterial coronária na coorte latino-americana. As lesões tendiam a ser mais complexas em mulheres latino-americanas, com menor diâmetro de referência do vaso-alvo, maior extensão da lesão, maior excentricidade e angulação e mais lesões tipo B2/C. Os eventos foram adjudicados de acordo com as definições do Academic Research Consortium. Em um ano, o desfecho combinado de morte por todas as causas, IM e revascularização do vaso-alvo (RVA) foi de 12,1% na população não-latino-americana e de 10,1% na população latino-americana (P = 0,58). CONCLUSÕES: Em um ano, os baixos índices de eventos cardíacos adversos, incluindo trombose do stent, falha da lesão-alvo, morte cardíaca, IM e RVA nas mulheres latino-americanas foram comparáveis aos das mulheres não-latino-americanas, apesar da maior complexidade das lesões. Esses resultados demonstram a segurança e a eficácia do stent XIENCE TM V nessa pequena coorte de pacientes latino-americanas, à semelhança do que é observado com populações maiores e mais variadas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUÇÃO: Baseados na hipótese de que a neoíntima encontrada em stents farmacológicos (SFs) com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva e de que a tomografia de coerência óptica (TCO) é um método eficaz para a avaliação sequencial da neoíntima, objetivamos, neste estudo experimental, comparar os achados da TCO aos 28 dias e aos 90 dias em dois tipos de SF com polímeros biodegradáveis: o stent liberador de sirolimus (Inspiron®, Scitech) e o stent liberador de biolimus A9 (Biomatrix®, Biosensors International). MÉTODOS: No total, 6 porcos não-ateroscleróticos foram submetidos a implante de 6 stents Inspiron® e de 6 stents Biomatrix®. Cada porco recebeu os dois tipos de stent, um em cada artéria coronária (descendente anterior e circunflexa) e após 28 dias e 90 dias foram realizadas avaliações qualitativas intrastent a cada milímetro com TCO. RESULTADOS: A avaliação qualitativa, feita por pareamento milímetro a milímetro intrastent, evidenciou neoíntima heterogênea em 39% aos 28 dias e em 0% aos 90 dias, presença de tecido intraluminal em 18% aos 28 dias e em 0% aos 90 dias, irregularidade luminal em 62% aos 28 dias e em 2% aos 90 dias (P < 0,005). Não houve diferença entre os grupos quanto à qualidade da neoíntima ao longo do tempo (P > 0,05). CONCLUSÕES: Os achados à TCO corroboram a hipótese de que a neoíntima encontrada em SFs com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva. A evidência experimental mais significativa é a mudança das características da neoíntima observada à TCO sequencial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Navigation through a previously deployed and deformed stent is a difficult interventional task. Inadvertent navigation through the struts of a stent can potentially lead to incomplete secondary stent extension and vessel occlusion. Better visualisation of the pathway through the stent can reduce the risks of the procedural complications and reduce the reluctance of the interventionalist to navigate through a previously deployed stent. We describe a technique of visualisation of the pathway navigated by a guidewire through a previously deployed deformed and fractured carotid stent by the use of DynaCT. Three-dimensional reconstruction of the stent/microwire allows excellent visualisation of the correct pathway of the microwire within the stent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incomplete endothelialization has been found to be associated with late stent thrombosis, a rare but devastating phenomenon, more frequent after drug-eluting stent implantation. Optical coherence tomography (OCT) has 10 times greater resolution than intravascular ultrasound and thus appears to be a valuable modality for the assessment of stent strut coverage. The LEADERS trial was a multi-centre, randomized comparison of a biolimus-eluting stent (BES) with biodegradable polymer with a sirolimus-eluting stent (SES) using a durable polymer. This study sought to evaluate tissue coverage and apposition of stents using OCT in a group of patients from the randomized LEADERS trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital pseudarthrosis of the tibia (CPT) is caused by an ill-defined, segmental disturbance of periosteal bone formation leading to spontaneous bowing, followed by fracture and subsequent pseudarthrosis in the first 2 years of life. The results of conventional treatment modalities (e.g., bracing, internal and external fixation and bone grafting) are associated with high failure rates in terms of persisting pseudarthrosis, malunion and impaired growth. As a more promising alternative, a more aggressive approach, including wide resection of the affected bone, reconstruction with free vascularised fibula grafts from the healthy contralateral leg and stable external fixation at a very early stage has been suggested. Between 1995 and 2007, 10 children (age 12-31 months, median 20 months) suffering from CPT were treated at our institutions according to this principle. Two patients were treated before a fracture had occurred. The length of the fibula graft was 7-9cm. End-to-end anastomoses were performed at the level of the distal tibia stump. The follow-up was 80 months (median, range 12 months to 12 years). Radiologic examination at 6 weeks postoperatively showed normal bone density and structure of the transplanted fibula in all cases and osseous consolidation at 19 of the 20 graft/tibia junctions. One nonunion was sucessfully treated with bone grafting and plate osteosynthesis. Pin-tract infection occurred in three patients. Five children sustained graft fractures that were successfully treated with internal or external fixation. Two patients developed diminished growth of the affected limb or foot; all others had equal limb length and shoe size. At long-term follow-up, tibialisation of the transplant had occurred, and normal gait and physical activities were possible in all children. We conclude that in spite of a relatively high complication rate and the reluctance to perform free flap surgery in infants at this young age, the present concept may successfully prevent the imminent severe sequelae associated with CPT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives We compared the angiographic and long-term clinical outcomes of patients with and without overlap of drug-eluting stents (DES). Background DES overlap has been associated with delayed healing and increased inflammation in experimental studies, but its impact on clinical outcome is not well established. Methods We analyzed the angiographic and clinical outcomes of 1,012 patients treated with DES in the SIRTAX (Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization) trial according to the presence or absence of stent overlap and the number of stents per vessel: 134 (13.2%) patients with multiple DES in a vessel with overlap, 199 (19.7%) patients with multiple DES in a vessel without overlap, and 679 (67.1%) patients with 1 DES per vessel. Results Angiographic follow-up at 8 months showed an increased late loss in DES overlap patients (0.33 ± 0.61 mm) compared with the other groups (0.18 ± 0.43 mm and 0.15 ± 0.38 mm, p < 0.01). The smallest minimal lumen diameter was located at the zone of stent overlap in 17 (68%) of 25 patients with stent overlap who underwent target lesion revascularization. Major adverse cardiac events were more common in patients with DES overlap (34 events, 25.4%) than in the other groups (42 events, 21.1% and 95 events, 14.0%) at 3 years (p < 0.01). Both the risk of target lesion revascularization (20.2% vs. 16.1% vs. 9.7%, p < 0.01) and the composite of death or myocardial infarction (17.2% vs. 14.1% vs. 9.1%, p = 0.01) were increased in patients with DES overlap compared with the other groups. Conclusions DES overlap occurs in >10% of patients undergoing percutaneous coronary intervention in routine clinical practice and is associated with impaired angiographic and long-term clinical outcome, including death or myocardial infarction. (Sirolimus-Eluting Versus Paclitaxel-Eluting Stents for Coronary Revascularization; NCT00297661).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports the 12-month clinical outcomes of the LEADERS clinical trial which compared a biolimus eluting stent with a biodegradable polymer (BES) to a sirolimus eluting stent with a durable polymer (SES).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The closing sounds of mechanical heart valves can be disturbing for patients and their closest relatives. Although some investigations into mechanical heart valve sounds have been performed, the particularities of the valve sound when it is attached to a vascular prosthesis to replace the aortic root and the ascending aorta has not been studied to date. The study aim was to compare the closing sounds of three various mechanical composite graft prostheses, and to analyze the impact of such sounds on the patients' quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impaired response to antiplatelet therapy with acetylsalicylic acid (ASA) and clopidogrel (CLO) has been associated with an increased risk of stent thrombosis and ischemic events after coronary stent implantation. We sought to investigate whether patients with a low response (LR) to ASA or CLO are at increased risk for periprocedural and short-term ischemic events after coronary stent implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore8 and 16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).