940 resultados para standard lifting


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: When treating peripheral ectatic disease-like pellucid marginal degeneration (PMD), corneal cross-linking with UV-A and riboflavin (CXL) must be applied eccentrically to the periphery of the lower cornea, partly irradiating the corneal limbus. Here, we investigated the effect of standard and double-standard fluence corneal cross-linking with riboflavin and UV-A (CXL) on cornea and corneal limbus in the rabbit eye in vivo. METHODS: Epithelium-off CXL was performed in male New Zealand White rabbits with two irradiation diameters (7 mm central cornea, 13 mm cornea and limbus), using standard fluence (5.4 J/cm(2)) and double-standard fluence (10.8 J/cm(2)) settings. Controls were subjected to epithelial removal and riboflavin instillation, but were not irradiated with UV-A. Following CXL, animals were examined daily until complete closure of the epithelium, and at 7, 14, 21, and 28 days. Animals were killed and a corneoscleral button was excised and processed for light microscopy and immunohistochemistry. RESULTS: For both irradiation diameters and fluences tested, no signs of endothelial damage or limbal vessel thrombosis were observed, and time to re-epithelialization was similar to untreated controls. Histological and immunohistochemical analysis revealed no differences in the p63 putative stem cell marker expression pattern. CONCLUSIONS: Even when using fluence twice as high as the one used in current clinical CXL settings, circumferential UV-A irradiation of the corneal limbus does not alter the regenerative capacity of the limbal epithelial cells, and the expression pattern of the putative stem cell marker p63 remains unchanged. This suggests that eccentric CXL may be performed safely in PMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper introduces the evaluation report after fostering a Standard-based Interoperability Framework (SIF) between the Virgen del Rocío University Hospital (VRUH) Haemodialysis (HD) Unit and 5 outsourced HD centres in order to improve integrated care by automatically sharing patients' Electronic Health Record (EHR) and lab test reports. A pre-post study was conducted during fourteen months. The number of lab test reports of both emergency and routine nature regarding to 379 outpatients was computed before and after the integration of the SIF. Before fostering SIF, 19.38 lab tests per patient were shared between VRUH and HD centres, 5.52 of them were of emergency nature while 13.85 were routine. After integrating SIF, 17.98 lab tests per patient were shared, 3.82 of them were of emergency nature while 14.16 were routine. The inclusion of a SIF in the HD Integrated Care Process has led to an average reduction of 1.39 (p=0.775) lab test requests per patient, including a reduction of 1.70 (p=0.084) in those of emergency nature, whereas an increase of 0.31 (p=0.062) was observed in routine lab tests. Fostering this strategy has led to the reduction in emergency lab test requests, which implies a potential improvement of the integrated care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hepatitis D virus (HDV) is endemic in the Amazon Region and its pathophysiology is the most severe among viral hepatitis. Treatment is performed with pegylated interferon and the immune response appears to be important for infection control. HDV patients were studied: untreated and polymerase chain reaction (PCR) positive (n = 9), anti-HDV positive and PCR negative (n = 8), and responders to treatment (n = 12). The cytokines, interleukin (IL)-2 (p = 0.0008) and IL-12 (p = 0.02) were differentially expressed among the groups and were also correlated (p = 0.0143). Future studies will be conducted with patients at different stages of treatment, associating the viral load with serum cytokines produced, thereby attempting to establish a prognostic indicator of the infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recently released Affymetrix Human Gene 1.0 ST array has two major differences compared with standard 3' based arrays: (i) it interrogates the entire mRNA transcript, and (ii) it uses DNA targets. To assess the impact of these differences on array performance, we performed a series of comparative hybridizations between the Human Gene 1.0 ST and the Affymetrix HG-U133 Plus 2.0 and the Illumina HumanRef-8 BeadChip arrays. Additionally, both RNA and DNA targets were hybridized on HG-U133 Plus 2.0 arrays. The results show that the overall reproducibility of the Gene 1.0 ST array is best. When looking only at the high intensity probes, the reproducibility of the Gene 1.0 ST array and the Illumina BeadChip array is equally good. Concordance of array results was assessed using different inter-platform mappings. Agreements are best between the two labeling protocols using HG-U133 Plus 2.0 array. The Gene 1.0 ST array is most concordant with the HG-U133 array hybridized with cDNA targets. This may reflect the impact of the target type. Overall, the high degree of correspondence provides strong evidence for the reliability of the Gene 1.0 ST array.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiotherapy with concomitant and adjuvant TMZ is the standard of care for newly diagnosed GBM. MGMT methylation status may be an important determinant of treatment response. This trial, conducted by the RTOG, EORTC, and NCCTG, determined if intensified TMZ improves survival (OS) or progression free survival (PFS) in all patients or specific to MGMT status. Eligibility criteria included age . 18 yrs, KPS ≥ 60, and existence of a tissue block with . 1cm2 tumor for prospective MGMT and retrospective molecular analysis. Patients were randomized to Arm 1: standard TMZ (150-200 mg/m2 x 5 d) or Arm 2: dd TMZ (75-100 mg/m2 x 21 d) q 4 wks for 6-12 cycles. Symptom burden, quality of life (QOL), and neurocognition were prospectively and longitudinally assessed in a patient subset. 833 patients were randomized (1173 registered). Inadequate tissue (n ¼ 144) was the most frequent reason for nonrandomization.No statistical difference was observed between Arms 1 and 2 for median OS (16.6, 14.9 mo, p ¼ 0.63), median PFS (5.5, 6.7 mo, p ¼ 0.06), or methylation status. MGMT methylation was associated with improved OS (21.2, 14 mo, p , 0.0001), PFS (8.7, 5.7 mo, p , 0.0001), and treatment response (p ¼ 0.012). Cox modeling identifiedMGMT status and RPA class as significant predictors of OS; treatment arm and radiation technique (EORTC vs. RTOG) were not. There was increased grade ≥ 3 toxicity in Arm 2 (19%, 27%, p ¼ 0.008), which was mostly lymphopenia and fatigue. This study did not demonstrate improved efficacy for dd TMZ for newly diagnosed GBM regardless of methylation status. However, it confirmed the prognostic significance of MGMT methylation in GBM, demonstrated the feasibility of tumor tissue collection, molecular stratification, and collection of patient outcomes in a large transatlantic intergroup trial, thereby establishing a viable clinical trial paradigm. Support: NCI U10 CA 21661 and U10 CA37422.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs: Comparer la qualité d'image entre des protocoles dose-standard avec rétroprojection filtrée et basse-dose avec reconstruction itérative en scanner du rachis cervical. Matériels et méthodes: 40 patients ont été investigués par scanner du rachis cervical et prospectivement randomisés en 2 groupes: dose-standard (120kV, 275mAs) avec rétroprojection filtrée, basse-dose (120kV, 150mAs) avec reconstruction itérative. Mesure du bruit, signal-sur-bruit et contraste-sur-bruit. Analyse semi-quantitative (4 points) par 2 observateurs indépendants des disques, foramens, cordon médullaire, ligaments, parties molles et vertèbres, en C3-C4 et C6-C7. Evaluation semi-quantitative (10 points) de la qualité d'image globale. Les paramètres de dose ont été mesurés. Résultats: Il n'y avait aucune différence significative de bruit, signal-sur-bruit ou contraste-sur-bruit entre les 2 protocoles (p≥0.39). En basse-dose avec reconstruction itérative, la visibilité était significativement meilleure pour les disques, foramens et ligaments (p≤0.05), égale pour le cordon médullaire et moins bonne pour les parties molles et vertèbres (p≤0.02). La qualité d'image globale était meilleure, avec une réduction de dose de 41%. Conclusion: Le scanner du rachis cervical basse-dose avec reconstruction itérative fournit des images égales ou meilleures pour les disques, foramens et ligaments, tout en réduisant la dose d'environ 40%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to assess the knowledge and attitude of health care professionals regarding their use of universal precaution measures at a public emergency service. The study also aimed to assess the rates of occupational accidents involving biological substances among those workers. This study was performed with 238 workers, from June to November 2006, using univariate and multivariate analysis. The chance of not adopting precaution measures was 20.7 (95% CI: 5.68 - 75.14) times greater among drivers compared to physicians. No significant association was found between adopting universal precaution measures. The occupational accident rate was 20.6% (40.8% involving sharp-edged objects). The risk of physicians having an occupational accident was 2.7(95% CI: 1.05 - 7.09) times higher than that of drivers. The fact that a staff member had adequate knowledge about universal precaution measures was insufficient to foster compatible attitudes towards reducing the risk of transmitting infectious agents and causing occupational accidents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: The current gold standard in Barrett's esophagus monitoring consists of four-quadrant biopsies every 1-2 cm in accordance with the Seattle protocol. Adding brush cytology processed by digital image cytometry (DICM) may further increase the detection of patients with Barrett's esophagus who are at risk of neoplasia. The aim of the present study was to assess the additional diagnostic value and accuracy of DICM when added to the standard histological analysis in a cross-sectional multicenter study of patients with Barrett's esophagus in Switzerland. METHODS: One hundred sixty-four patients with Barrett's esophagus underwent 239 endoscopies with biopsy and brush cytology. DICM was carried out on 239 cytology specimens. Measures of the test accuracy of DICM (relative risk, sensitivity, specificity, likelihood ratios) were obtained by dichotomizing the histopathology results (high-grade dysplasia or adenocarcinoma vs. all others) and DICM results (aneuploidy/intermediate pattern vs. diploidy). RESULTS: DICM revealed diploidy in 83% of 239 endoscopies, an intermediate pattern in 8.8%, and aneuploidy in 8.4%. An intermediate DICM result carried a relative risk (RR) of 12 and aneuploidy a RR of 27 for high-grade dysplasia/adenocarcinoma. Adding DICM to the standard biopsy protocol, a pathological cytometry result (aneuploid or intermediate) was found in 25 of 239 endoscopies (11%; 18 patients) with low-risk histology (no high-grade dysplasia or adenocarcinoma). During follow-up of 14 of these 18 patients, histological deterioration was seen in 3 (21%). CONCLUSION: DICM from brush cytology may add important information to a standard biopsy protocol by identifying a subgroup of BE-patients with high-risk cellular abnormalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rising renal cell carcinoma incidence is in relationship with early diagnosis during radiological exams. Radical nephrectomy was the gold standard treatment for 30 years. Partial nephrectomy is nowadays a validated therapeutic option for renal cell carcinoma up to 7 cm with comparable oncological results associated with better life quality and survival. Partial nephrectomy is tricky and laparoscopic approach remains reserved for expert centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

NovoTTF-100A (TTF) is a portable device delivering low-intensity, intermediate-frequency, alternating electric fields using noninvasive, disposable scalp electrodes. TTF interferes with tumor cell division, and it has been approved by the US Food and Drug Administration (FDA) for the treatment of recurrent glioblastoma (rGBM) based on data from a phase III trial. This presentation describes the updated survival data 2 years after completing recruitment. Adults with rGBM (KPS ≥ 70) were randomized (stratified by surgery and center) to either continuous TTF (20-24 h/day, 7 days/week) or efficacious chemotherapy based on best physician choice (BPC). The primary endpoint was overall survival (OS), and secondary endpoints were PFS6, 1-year survival, and QOL. Patients were randomized (28 US and European centers) to either TTF alone (n ¼ 120) or BPC (n ¼ 117). Patient characteristics were balanced, median age was 54 years (range, 23-80 years), and median KPS was 80 (range, 50-100). One quarter of the patients had debulking surgery, and over half of the patients were at their second or later recurrence. OS in the intent-to-treat (ITT) population was equivalent in TTF versus BPC patients (median OS, 6.6vs. 6.0 months; n ¼ 237; p ¼ 0.26; HR ¼ 0.86). With a median follow-up of 33.6 months, long-term survival in the TTF group was higher than that in the BPC group at 2, 3, and 4 years of follow-up (9.3% vs. 6.6%; 8.4% vs. 1.4%; 8.4% vs. 0.0%, respectively). Analysis of patients who received at least one treatment course demonstrated a survival benefit for TTF patients compared to BPC patients (median OS, 7.8 vs. 6.0 months; n ¼ 93 vs. n ¼ 117; p ¼ 0.012; HR ¼ 0.69). In this group, 1-year survival was 28% vs. 20%, and PFS6 was 26.2% vs. 15.2% (p ¼ 0.034). TTF, a noninvasive, novel cancer treatment modality shows significant therapeutic efficacy with promising long-term survival results. The impact of TTF was more pronounced when comparing only patients who received the minimal treatment course. A large-scale phase III trial in newly diagnosed GBM is ongoing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Head and neck squamous cell carcinomas are frequently diagnosed at an advanced stage. Their treatment remains controversial, and has to be multidisciplinary. External beam radiotherapy is a recognized treatment option after radical curative surgery in order to improve local control. Different adjuvant treatment options have been studied in order to improve the outcome of these patients. We review in this paper the different prognostic factors indicating an adjuvant treatment and the interest of treatment intensification in bad prognostic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper revisits the issue of the regulatory choice between a mandatory label and a minimum-quality standard. When the cost of regulation is relatively low, we show that the socially optimal choice depends on the producers’ cost structure for complying with regulation and improving quality. Under a marginal cost for improving quality, the mandatory labeling is sufficient for reaching the socially optimal level of quality. Under a fixed cost for improving quality, we show that each instrument or the combination of both instruments may emerge at the equilibrium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigates the syntactic, semantic, and pragmatic properties of nominal Split Topicalization (ST) constructions in Standard and non-Standard German. The topic phrase denotes a property, and the MF phrase either modifies this property or picks out a specific entity. Semantically, the topic phrase will be analysed as a property-denoting expression which restricts the denotation of the verbal predicate, while the MF phrase is composed either via specify or restrict (cf. Chung and Ladusaw, 2003). Syntactically, the base position of the topic phrase is the (incorporating) verb, and the MF phrase is generated independently as the complement of the verb containing an empty pronoun. Since predicates introduce abstract discourse referents, the topic phrase can be resumed via "pro" in the MF phrase.